SUNCO Utility Shop Light Installation Guide

SUNCO Utility Shop Light Installation Guide

UTILITY SHOP LIGHT Install Guide and Manual

Required Tools: Drill, Ladder, Hammer, Pliers, Tape Measure, Pencil.

COMPONENTS

EASY INSTALLATION Suspension Install

  1. Turn off circuit breaker that provides power to the light switch for the recessed lights.
  2. Mounting surface must be able to support the weight of the fixture.• Plaster board – #8 eye hook screw with plastic anchors, or expansion bolts (not included);• Plaster board thickness should be 3/8 inch.
  3. Attach two anchors to ceiling. Spacing between hooks should be 46.83 inches apart, then screw in the screw eye hooks into the anchors.
  4. Depending on your lighting plan, space the anchors accordingly.• Link up to 4
  5. Install one S hook into each end of the chain, then crimp the end attached to the chain with pliers. Leaving the other side open.• Repeat with second chain
  6. Insert the included 48” power cord into the end cap.
  7. Secure the flat power cord to the chain using the provided zip tie prior to hanging.
  8. Hang the lose end of the S hook chain onscrew eye hook in ceiling. Repeat with second chain.
  9. Plug in power cord to electrical outlet.
  10. Turn on circuit breaker and test light.

SPECIFICATIONS

Voltage                                                                  120VWattage                                                                 40WSuitable for Locations Ingress                              DampHousing                                                                Steel + PCWeight                                                                  1.47lbsWarranty                                                              7 years

WARNING

All electrical connections must be in accordance with local and National Electric Code (N.E.C.) standards. Consult a qualified electrician if you are unfamiliar with proper electricalwiring connections. Please review instructions carefully before proceeding.

WARNING: Risk of fire or electric shock. Do not alter, relocate or remove wiring (plug) during installation. This fixture complies with Part 15 of the FCC rules. Operation is subject to the followingtwo conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: When using the wall switch, make sure the pull chain is on. Not for use with dimmers. Do not install directly over a heat source. Do not use the plug on the side of the LED Shop Light as an outlet for appliances, vacuums, power tools, extension cables, etc. This was designed for daisy chain use only. Using it for other purposes will void your warranty

 

 