MW 15W Ultra Slim Step Shape DIN Rail Instructions

15WUltra Slim Step Shape DIN-RailHDR-15 series

Features

  • Ultra slim design with 17.5mm (1SU) width
  • Universal input 85~264VAC (277VAC operational)
  • No load power consumption<0.3W
  • Isolation class II
  • Pass LPS (Limited power source)
  • DC output voltage adjustable
  • Protections: Short circuit/Overload/Over voltage
  • Cooling by free air convection (working temperature: -30~+70°C)
  • DIN rail TS-35/7.5 or 15 mountable
  • Overvoltage category III
  • LED indicator for power on
  • 3 years warranty

Applications

  • Household control system
  • Building automation
  • Industrial control system
  • Factory automation
  • Electro-mechanical apparatus

Description

HDR-15 is one economical ultra-slim 15W DIN rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 17.5mm(1SU) in width, which allows space-saving inside the cabinets. The entire series adopts the full range AC input from 85VAC to 264VAC (277VAC operational) and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current.HDR-15 is designed with plastic housing that can effectively prevent a user from electric hazards. With a working efficiency of up to 87%, the entire series can operate at the ambient temperature between -30°C and air convection. The complete protection functions and relevant certificates for home automation and industrial 70°C under control apparatus (IEC60950-1, UL508, UL60950-1, EN61558-2-16) make HDR-65 a very competitive power supply solution for household and industrial applications.

Model Encoding

SPECIFICATION

MODEL HDR-15-5 HDR-15-12 HDR.45-15 HDR-15-24 HDR-15-411
OUTPUT DC VOLTAGE 5V 12V 15V 24V 48V
RATED CURRENT 2.4A 125A 1A 0.63A 0.32A
CURRENT RANGE 0-2.4A 0 – 1.25A 0-IA 0 – 0.63A 0 -0.32A
RATED POWER 12W 15W 15W 15.2W 15.4W
RIPPLE 8 NOISE (max.) Natal 80mVp-p 120mVp-p 120mVp-p 150mVp-p 240mVp-p
VOLTAGE ADJ. RANGE 4.5 – 5.5V 10.8 – 13.8V 135 – 18V 21.6 – 29V 43.2 – 55.2V
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0% ±1.0% ±1.0%
LINE REGULATION ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
LOAD REGULATION ±1.0% ±1.0% ±1.0% ±1.0% ±1.0%
SETUP, RISE TIME 2000ms. 80ms(230VAC, 2000ms. 80ms/115VAC at fel load
HOLD UP TIME (Typ.) 30ms230VAC, 12ms/115VAC at ful load
INPUT VOLTAGE RANGE 85 – 264VAC (277VAC opesaticnal ) , 120- 370VDC (390NDC operational )
FREQUENCY RANGE 47 -63Hz
EFFICIENCY (Typ.) BO% ,  185%  ,185.5%, 186%, 187%
AC CURRENT (Typ.) 0.5A/115VAC, 0.25A230VAC
INRUSH CURRENT (Typ.) COLD START 25A/115VAC ,  45N230VAC
PROTECTION OVERLOAD 110 – 145% rated output power
Hiccup mode Wien output voltage <50%. recovers automatically after fault condition is removed

Constant current Laing within 50% -100% rated output voltage, recovers automatically after faun ooncteon is removed

OVER VOLTAGE 5.75 – 6.75V 14.2- 16.2V                        1 18.8 – 22.5V 30′- 36V 56 5 – 64.6V
Protection type : Shut off o/p voltage, Swale by zener diode
EIPPROMIERT WORKING TEMP. -30 – +70t (Refer Tel:/eating Curve)
WORKING HUMIDITY 20 – 90% RH non-condensing
STORAGE TEMP., HUMIDITY -40-485’C, 10- 95% RH non-condensitg
TEMP. COEFFICIENT -±0.03%R.: (0 – 50.C) RH non-condensing
VIBRATION 10- 500Hz. 2G 10min./Icycle. period fa 60min. each along X. Y. Z axes: Mounting: Compliance to IEC60068-2-6
OPERATING ALTITUDE 2000 meters
OVER VOLTAGE CATEGORY ill : According to EN61558, EN50178,EN60664-1, EN62477-1 : altitude up to 2000 meters
SAFETY &

EMC (Nets 4)

SAFETY STANDARDS UL60950-1, UL508, TUV EN61558-2-16.IEC60950-1, EAC TP TC 004, BSMI CNS14336-1 approved: Design refer to TUV EN60950-1
WITHSTAND VOLTAGE 1/P-01P:4KVAC
ISOLATION RESISTANCE UP-OIP:100M Ohms! 500VDC / 25C/ 70% RH
EMC EMISSION Parameter Standard Test Level / Note
Conducted EN55032(CISPR32), CNS13438 Class B
Radiated EN55032(CISPR32). CN$13438 Class 8
Harmonic Current EN61000-3-2 Class A
Voltage Facies EN61000-3-3
EMC IMMUNITY EN55024, EN55035. EN61000-6-2. EN61204-3
Parameter Standard Test Level /Note
ESD EN61000-4-2 Level 3. BKV air: Level 2, 4XV contact. °mem A
Radiated Susceptibility EN61000-4-3 Leve13. aiteria A
EFT/Burest EN61000-4-4 Leve13. crrteria A
Surge EN61000-4-5 Leve14,2KV/L-N, aiteria A
Conducted EN61000-4-6 Level 3. criteria A
Magnetic Field EN61000-4-8 Level 4. aiteda A
Voltage Dips and interruptions EN810004-11 >95% dip 0.5 periods. 30% dip 25 periods. >95% interruptions 250 periods
OTHERS MTBF 1166K hrs mil.  MIL-HDBK-217F (25t)
DIMENSION 17.5’90’54.5mm (WI-I’D)
PACKING 78g:160pcs/13.5149/1.19CUFT

NOTE

  1.  All parameters NOT specially mentioned are measured at 230VAC input, rated load, and 25°C of ambient temperature.
  2.  Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1μf & 47μf  parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation, and load regulation.
  4. The power supply is considered as an independent unit, but the final equipment still needs to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
  5. The ambient temperature derating of 3.5/1000m with fanless models and of 5/1000m with fan models for operating altitude higher than 2000m(6500ft).

Block Diagram

Derating CurveOutput Derating VS Input Voltage

Mechanical Specification

( Unit: mm , tolerance ± 0.5mm)

 

Installation Manual

Please refer to : http://www.meanwell.com/manual.html

References

[xyz-ips snippet=”download-snippet”]


Posted