Recommended Bulb

3 x 5 Watt G9 energy efficient LED

Specification

Max power: 5WVoltage: 220~240V, 50/60HzIP44 Weight 1.9 KgPlease retain these instructions for future reference.

This symbol indicates that this product should not be treated as normal household waste and it should be recycled. John Lewis does not operate in store take back, but as members of the Distributer Take Back scheme have funded the development and upgrade of recycling facilities across the UK. Please take it to your nearest collection facility or for further details contact your local council or visit www.recycle-more.co.uk. We have taken great care to ensure that this product reaches you in perfect condition. However, should any parts be damaged or missing please e-mail

Trouble Shooting:

Why is the light not working when switched on?Check your power supply is switched on Turn off light and check that the bulb is inserted correctly Check the bulb is still in working order.

John Lewis partnership 171 Victoria Street London SW1E 5NN Johnlewis.com

Thank you for purchasing this White Marble wall light. Please read the instructions carefully before use to ensure safe and satisfactory operations of this product. Please keep this instruction for future reference.

Warnings!

For your safety, this product must be installed in accordance with local Building Regulations. If in any doubt, or where required by the law, consult a competent person who is registered with an electrical self-certification scheme. Further information is available online or phone your Local Authority. To prevent electric shock, switch off the mains supply before installing or maintaining this product. Ensure other persons cannot restore the electricity supply without your knowledge. Always use the correct bulb type with the correct wattage as indicated in the specification table. This product is Class and should be fitted to a lighting Supply (with earth) protected by a 5 amp fuse or equivalent circuit breaker. When changing the bulb, always switch off at the mains and allow the old bulb to cool down before handling. Dispose of used bulbs carefully. This fitting is rated IP44 making it suitable for use in Zones 1 & 2 of a bathroom when fitted in accordance with IEE wiring regulations (see diagram overleaf). Fitting must be connected to a supply protected by a 30mA RCD in Zone 1.Caution! The bulb and surrounding parts can become hot during use.For indoor use only.

Care Instructions

We recommend cleaning with a soft dry cloth. Do not use abrasive materials as these will damage the finish. Replace bulbs from John Lewis or established brand of the same type and compatibility.

Parts List

Part List

Qty

A.

1

B.

1

C.

2

D.

4

E.

3

F.

3

Assembly

Never install your appliance on a wet, freshly painted or plastered surface. Ensure the house electricity supply is switched off at the fuse box. If removing an existing fitting, note down all wiring connections. Check the fixings will not touch any existing wiring before drilling and attaching the light to the wall. Ensure you thread the wall wires through the black insulating tube fixed to the appliance.

Step 1:Remove mounting bracket from fitting by removing the retaining screws and washers, retain for later. Using the mounting bracket as a template, mark and then drill the fixing holes in the wall (ensure the screws are firmly fixed into a solid or other suitable mounting and not just the plasterboard.). Take care not to damage wiring. Attach mounting bracket to the mounting surface using Step 1 suitable fixings. Do not attach fitting to mounting bracket at this stage. Make sure no wires are trapped in the process.Step 2:Ensuring that the power has been isolated, Lever open the terminal block box cover with a screwdriver, pierce a hole in the black rubber end cap of the terminal block then feed supply cable through. Make electrical connections as follows:

  • Connect supply live to fitting live (marked “L”) on the terminal block.
  • Connect supply neutral to fitting neutral (marked “N”) on the terminal block.
  • Connect the supply earth to the earth (marked ) on the terminal block.

NOTE: Ensure electrical connections are tight and no loose strands of wire are left out of the connector block. Excess cable must be carefully located inside ceiling cup or within the ceiling void. Excess cable must be carefully located inside the wall plate or within the wall cavity itself. Carefully offer fitting over mounting bracket then secure in place with the screws and washers removed earlier.Step 3:Fit the bulb, type and wattage as indicated on the fitting (bulb not supplied). The wattage indicated must not be exceeded. Step 3 Place a silicone washer over each of the lamp holders.Fit the shade: Offer the shade glass over the lamp holder section, align the treads and carefully screw into place. If cross-threading occurs, undo and start again. Take care not to overtighten as this may cause damage to the fitting.Once installation is complete, the house electricity may be restored at the fuse box.

References