Features

  • Universal AC input / Full range.
  • Protections: Short circuit / Overload / Over voltage / Over temperature.
  • Cooling by free air convection.
  • Can be installed on DIN rail TS-35/7.5 or 15.
  • UL 508 (industrial control equipment) approved.
  • EN61000-6-2(EN50082-2) industrial immunity level.
  • 100% full load burn-in test.
  • 3 years warranty

Description

NDR-120 is one economical slim 120W DIN rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 40mm in width, which allows space saving inside the cabinets. The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to EN61000-3-2, the norm the European Union regulates for harmonic current.NDR-120 is designed with metal housing that enhances the unit’s power dissipation. With working efficiency up to 89%, the entire series can operate at the ambient temperature between -20°C and 70°C under air convection. It is equipped with constant current mode for over-load protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control apparatus (UL508, TUV EN62368-1, and etc.) make NDR-120 a very competitive power supply solution for industrial applications.

Model Encoding

Applications

  • Industrial control system.
  • Semiconductor fabrication equipment.
  • Factory automation.
  • Electro-mechanical apparatus

SPECIFICATION

MODEL

NDR-120-12

NDR-120-24

NDR-120-48

OUTPUT

DC VOLTAGE

12V 24V 48V

RATED CURRENT

10A

5V

2.5V

CURRENT RANGE

0 ~ 10A 0 ~ 5A

0 ~ 2.5A

RATED POWER

120W

120W

120W

RIPPLE & NOISE (max.) Note.2

100mVp-p

120mVp-p

150mVp-p

VOLTAGE ADJ. RANGE

12 ~ 14V

24 ~ 28V

48 ~ 55V

VOLTAGE TOLERANCE Note.3

±2.0% ±1.0% ±1.0%

LINE REGULATION

±0.5%

±0.5%

±0.5%

LOAD REGULATION

±1.0%

±1.0%

±1.0%

SETUP, RISE TIME

1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load

HOLD UP TIME (Typ.)

16ms/230VAC 10ms/115VAC at full load
INPUT VOLTAGE RANGE Note.6 90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]
FREQUENCY RANGE 47 ~ 63Hz

EFFICIENCY (Typ.)

85.5%

88%

89%

AC CURRENT (Typ.)

2.25A/115VAC 1.3A/230VAC

INRUSH CURRENT (Typ.)

20A/115VAC 35A/230VAC

LEAKAGE CURRENT

<1mA / 240VAC
PROTECTION

OVERLOAD

105 ~ 130% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed

OVER VOLTAGE

14 ~ 17V

29 ~ 33V

56 ~ 65V

Protection type : Shut down o/p voltage, re-power on to recover

OVER TEMPERATURE

Shut down o/p voltage, re-power on to recover
ENVIRONMENT

WORKING TEMP.

-20 ~ +70 (Refer to “Derating Curve”) ℃

WORKING HUMIDITY

20 ~ 95% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85 , 10 ~ 95% RH ℃

TEMP. COEFFICIENT

±℃ ℃ 0.03%/ (0 ~ 50 )

VIBRATION

Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC (Note 4)

SAFETY STANDARDS

UL508, TUV EN62368-1, approved;(meet EN60204-1) EAC TP TC 004

WITHSTAND VOLTAGE

I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC

ISOLATION RESISTANCE

I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25 / 70% RH ℃

EMC EMISSION

Compliance to EN55032 (CISPR32), EN61204-3 Class B, EN61000-3-2,-3, EAC TP TC 020

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2 (EN50082-2), EN61204-3, heavy industry level, criteria A, EAC TP TC 020
OTHERS

MTBF

456.3K hrs min. MIL-HDBK-217F (25 ) ℃

DIMENSION

40*125.2*113.5mm (W*H*D)

PACKING

0.6Kg; 20pcs/13Kg/1.16CUFT
NOTE
  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25t of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12″ twisted pair-wire terminated with a 0.1 of & 47uf parallel capacitor.
  3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
  5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
  6. Derating may be needed under low input voltage. Please check the derating curve for more details.
  7. The ambient temperature derating of 3.5t/1000m with fanless models and of 5t/1000m with fan models for operating altitude higher than 2000m(6500ft).
Block Diagram

Derating Curve

AMBIENT TEMPERATURE ( )

Static Characteristics

INPUT VOLTAGE (V) 60Hz

Mechanical Specification
  • Case No.992D Unit:mmTop View
  • Side View
  • Front View
  • Side View
  • Bottom ViewTerminal Pin No. Assignment (TB1)

    Pin No.

    Assignment

    1

    FG

    2

    AC/N or DC –

    3

    AC/L or DC +

    Terminal Pin No. Assignment (TB2)

    Part No.

    Assignment

    1

    DC OUTPUT -V

    2

    DC OUTPUT+V

Installation Instruction

Back ViewADMISSIBLE DIN-RAIL:TS35/7.5 OR TS35/15.(For reference only. Not included with unit.)

This series fits DIN rail TS35/7.5 or TS35/15.For installation details, please refer to the Instruction manual.

Installation Manual

Please refer to : http://www.meanwell.com/manual.html

 

References

[xyz-ips snippet=”download-snippet”]