UBIQUITI EdgePower DC Power Supply with UPS and PoE User Guide

UBIQUITI EdgePower DC Power Supply with UPS and PoE

Introduction

Thank you for purchasing the Ubiquiti Networks® EdgePower™. This Quick Start Guide is designed to guide you through installation and also includes warranty terms.

Package Contents

Installation Requirements

For wall-mounting:

  • Drill with 6 mm drill bit
  • Phillips screwdriver

WARNING: To reduce the risk of fire or electric shock, do not expose the EdgePower to rain or moisture.Note: Although the cabling can be located outdoors, the EdgePower itself should be housed inside.

Hardware Overview

Front Panel Ports

Interface                      Description

RJ45 1-2                        RJ45 switch ports support 10/100 Ethernet connections and 54V Passive Power over Ethernet (PoE) output.

DC Out                        Connect the Power Cable with DC Jack to this terminal block for 54V, 1.3A output.

Battery In                    Optional: Connect the Power Cable with Ring Terminals to a 12V lead acid battery (not included).

Power                          Connect the included Power Cord.

Note: The external battery may be used as a hot backup. It will provide continuous power in the event of an interruption or loss of power on the Power port.

Front Panel Button

Button              Description

Reset                To reset to factory defaults:1. Disconnect power from the EdgePower.2. Reconnect power while holding the Reset button. The port LEDs will repeatedly light up in sequential order (this takes approximately 5 seconds).3. When both port LEDs flash twice at the same time, release the Reset button.

Front Panel LEDs

System LED

State                                                                Status

Flashing White                                                Bootup in progress.White                                                              Ready for use, not connected to Ubiquiti® Network Management System (UNMS™).Blue                                                                Ready for use, connected to UNMS.Steady Blue with Occasional Flashing            Ready for use, unable to connect to UNMS, check connection to UNMS server.Quickly Flashing Blue                                    Used to locate a device in UNMSAlternating Blue/White                                Firmware upgrade in progress

You can use the EdgePower Configuration Interface or UNMS to manage your device. UNMS lets you configure, monitor, upgrade, and back up your devices using a single application. Get started at www.unms.com

RJ45 LEDs

LED                      State                                Status

PoE                      Off                                    No Power over EthernetAmber                              54V Power over EthernetOff                                  No Link

Link/ Activity        Amber                            Link Established at 10/100 MbpsAmber Flashing              Link Activity at 10/100 Mbps

Hardware Installation

The EdgePower can be mounted on a horizontal surface, mounted on a vertical surface, or mounted in a rack (rackmount accessory not included).

WARNING: The EdgePower must not be stacked. Do not place it on top of another device. Do not place anything on top of the EdgePower.WARNING: FAILURE TO PROVIDE PROPER VENTILATION MAY CAUSE FIRE HAZARD. KEEP AT LEAST 20 MM OF CLEARANCE NEXT TO THE VENTILATION HOLES FOR ADEQUATE AIRFLOW.

Connecting PowerUse the included Power Cord to power the EdgePower. You can also use the Battery Input option as a hot backup.

Using the Power Cord

1. Connect the Power Cord to the Power port.2. Connect the other end of the Power Cord to a power outlet.

Using the Battery Input (Optional)

For redundant power backup, connect an external battery (not included) to the EdgePower.

Note: Only one power source can be used at any one time. With both power sources connected, the AC input will be used; the battery input defaults to backup.

  1. Connect the 3-pin terminal block connector of the Power Cable with Ring Terminals to the Battery In port
  2. Wire the other end of the DC/DC power cable to an external 12VDC battery.
Connecting Ethernet
  1. Connect an Ethernet cable from your 54V PoE device(s) to ports 1-2 on the EdgePowerWARNING: Before enabling PoE out in the EdgePower Configuration Interface, ensure that the connected PoE device supports 54V Passive PoE
Connecting DC Output
  1. Connect the 3-pin terminal block connector of the Power Cable with DC Jack to the DC Out port.
  2. Connect the other end of the DC/DC power cable to a device with a DC jack.

Accessing the Configuration Interface

Access the EdgePower Configuration Interface to monitor status and power consumption, or to configure 54V Passive PoE and network settings.

Note: The EdgePower is set to DHCP by default with a fallback IP address of 192.168.1.20

  1. Launch your web browser. Type the appropriate IP address in the address field. Press enter (PC) or return (Mac).
  2. The login screen will appear. Enter ubnt in the Username and Password fields. Click Login.

The EdgePower Configuration Interface will appear. Customize additional settings as needed. For 54V Passive PoE configuration, refer to the Configuring PoE Settings section.You can also manage your device using UNMS, which lets you configure, monitor, upgrade, and back up your devices using a single application. Get started at www.unms.com

Configuring PoE Settings

The PoE setting for ports 1-2 is set to Off by default.

WARNING: Before activating PoE, ensure that the connected device supports passive PoE and the supplied voltage.

  1. In the EdgePower Configuration Interface, click the Power tab.
  2. For the appropriate port, click to enable 54V Passive PoE.
  3. Click Save Changes.

Specifications

EP-54V-72W
Dimensions 115 x 192 x 43.7 mm

(4.53 x 7.56 x 1.72″)

Weight 650 g (1.43 lb)
Interfaces

Networking Management

 

(2) 10/100 Mbps RJ45 Ports

Ethernet In-Band

PoE Output (2) 54VDC Passive PoE (Pins 4, 5+; 7,
DC Output 54V, 1.3A
Power Method AC Input Battery Input  

100-240VAC, 50-60 Hz, Universal Input

DC Terminal Block

Power Supply AC Input

Battery Input

 

AC/DC 72W

12VDC Lead Acid Battery*

Max. Power Consumption System

Output

 

2W

72W

LEDs

System

RJ45 Data Ports

 

Status PoE; Link/Activity

ESD/EMP Protection Air: ± 12 kV, Contact: ± 12 kV
Operating  Temperature 0 to 40° C (32 to 104° F)
Operating Humidity 10 to 90% Noncondensing
Certifications CE, FCC, IC

Safety Notices

  1. Read, follow, and keep these instructions.
  2. Heed all warnings.
  3. Only use attachments/accessories specified by the manufacturer.

WARNING: Failure to provide proper ventilation may cause fire hazard. Keep at least 20 mm of clearance next to the ventilation holes for adequate airflow.WARNING: To reduce the risk of fire or electric shock, do not expose this product to rain or moisture.WARNING: Do not use this product in location that can be submerged by water.WARNING: Avoid using this product during an electrical storm. There may be a remote risk of electric shock from lightning.

Electrical Safety Information
  1. Compliance is required with respect to voltage, frequency, and current requirements indicated on the manufacturer’s label. Connection to a different power source than those specified may result in improper operation, damage to the equipment or pose a fire hazard if the limitations are not followed.
  2. There are no operator serviceable parts inside this equipment. Service should be provided only by a qualified service technician.
  3. This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet.
    • Do not substitute the power cord with one that is not the provided approved type. Never use an adapter plug to connect to a 2-wire outlet as this will defeat the continuity of the grounding wire.
    • The equipment requires the use of the ground wire as a part of the safety certification, modification or misuse can provide a shock hazard that can result in serious injury or death.
    • Contact a qualified electrician or the manufacturer if there are questions about the installation prior to connecting the equipment.
    • Protective earthing is provided by Listed AC adapter. Building installation shall provide appropriate short-circuit backup protection.
    • Protective bonding must be installed in accordance with local national wiring rules and regulations.

Limited Warrantywww.ubnt.com/support/warranty/The limited warranty requires the use of arbitration to resolve disputes on an individual basis, and, where applicable, specify arbitration instead of jury trials or class actions.

Compliance

FCCChanges or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

ISED Canada

CAN ICES-3(A)/NMB-3(A)This Class A digital apparatus complies with Canadian CAN ICES-003.

Australia and New ZealandWarning: Operation of this equipment in a residential environment could cause radio interference.

CE MarkingCE marking on this product represents the product is in compliance with all directives that are applicable to it.

RoHS/WEEE Compliance Statement

European Directive 2012/19/EU requires that the equipment bearing this symbol on the product and/or its packaging must not be disposed of with unsorted municipal waste. The symbol indicates that this product should be disposed of separately from regular household waste streams. It is your responsibility to dispose of this and other electric and electronic equipment via designated collection facilities appointed by the government or local authorities. Correct disposal and recycling will help prevent potential negative consequences to the environment and human health. For more detailed information about the disposal of your old equipment, please contact your local authorities, waste disposal service, or the shop where you purchased the product.

Declaration of Conformity

Hereby, UBIQUITI NETWORKS, declares that this EP-54V-72W device, is in compliance with the essential requirements and other relevant provisions of Directives 2014/30/EU, 2014/35/EU. The full text of the EU declaration of conformity is available at the following internet address: www.ubnt.com/compliance

Online ResourcesSupport help.ubnt.comCommunity: community.ubnt.comDownloads downloads.ubnt.com

References

[xyz-ips snippet=”download-snippet”]