ULINE Service Kit For Impulse Sealer Instruction Manual

SERVICE KIT FOR IMPULSE SEALER

TAPE AND HEATING ELEMENT REPLACEMENT INSTRUCTIONSCAUTION! Unplug the sealer from the socket before proceeding.

  1. Remove screws along with the cover plates (A) and top Teflon cover (B). Remove element (C) from terminal posts. (See Figure 1)
  2. If bottom adhesive Teflon tape (D) is worn, burned, or ripped, it needs to be changed.Teflon tape keeps the element insulated from the sealer housing to ensure proper sealer operation. (See Figure 1) If this tape is not worn, go to step 5.
  3.  After removal of metal cover plates, Teflon tapes,, and elements, clean sealing surface (E) with cleaner until free of glue and debris.Adhesive remover is recommended. (See Figure 2)
  4. Peel off the backing of adhesive Teflon tape.Apply evenly onto the sealer.Excess tape should extend all the way to the terminal posts (F).If the element touches any metal, the sealer will short out. (See Figure 2)
  5. Attach a new heating element.
  6. Reassemble in reverse of step 1.The Teflon cover must be flush against the sealer before replacing cover plates.

REPLACEMENT PARTS

MODEL H-161 H-163 H-190 H-293 H-306 H-458 H-963 H-1029 H-1252
REPAIR KIT H-495 H-164 H-191 H-294 H-307 H-471 H-964 H-1042 H-1253

1-800-295-5510uline.com