ACURITE 00986 Digital Refrigerator/Freezer Thermometer Instruction Manual

Instruction ManualDigital Refrigerator/Freezer Thermometermodel 00986

Questions? Contact Customer Support at(877) 221-1252 or visit www.AcuRite.com.

SAVE THIS MANUAL FOR FUTURE REFERENCE.

Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.

Unpacking Instructions

Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel it off to remove it.

Package Contents

  1.  Display unit
  2. . 2 Wireless sensors
  3. Instruction manual

Features & Benefits: Sensors

  1. Sensor #1 For refrigerator (default) or freezer use.
  2. Wireless Signal IndicatorFlashes when data is being sent to the display unit.
  3. Battery Compartment
  4.  Sensor #2For freezer (default) or refrigerator use.
  5. Suction Cup / Shelf Clip(on back)For versatile mounting options.

Features & Benefits

Display Unit

  1. Sensor #1 ALARM ON/OFF Button
  2.  Sensor #2 ALARM ON/OFF Button
  3. Sensor #2 Current Temperature
  4.  Sensor #2 Low Battery Indicator
  5.  Sensor #2 Alarm ON Indicator
  6. Sensor #2 Low-Temperature Lowest temperature recorded.
  7. Sensor #2 High-TemperatureThe highest temperature recorded.
  8. CLR ButtonPress to reset High/Low records.
  9. – ButtonFor alarm setup preferences.
  10.  + ButtonFor alarm setup preferences.
  11. Sensor #1 Low-TemperatureThe lowest temperature was recorded.
  12. Sensor #1 High-TemperatureThe highest temperature was recorded.
  13. Sensor #1 Alarm ON Indicator
  14. Sensor #1 Low Battery Indicator
  15. Sensor #1 Current Temperature
  16. Magnet Mount
  17.  ºC/ºF SwitchSelect between degrees Celsius or Fahrenheit.
  18.  Integrated Hang HoleFor easy wall mounting.
  19. RESET ButtonFull reset to factory defaults.
  20. Battery Compartment

SETUP

Install or Replace Batteries

AcuRite recommends high-quality alkaline batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended.The freezer sensor requires lithium batteries for low-temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the freezer sensor for temperatures below -4ºF / -20ºC.

Thermometer Display

  1. Lift up the battery door and slide off the battery compartment cover.
  2.  Insert 2 x AAA batteries into the battery compartment. Follow the polarity (+/-) diagram in the battery compartment.
  3.  Replace the battery cover.

Sensors

  1.  Slide off the battery compartment covers, located on the front of the units.
  2.  Insert 2 x AA batteries into the battery compartment. Follow the polarity (+/-) diagram in the battery compartment.
  3. Replace the battery cover.

Select Degrees Fahrenheit or CelsiusTo select between degrees Fahrenheit (ºF) or Celsius (ºC) temperature units, slide the “ºC/ºF” switch, located on the back of the thermometer display.PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment that is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.

Display Unit PlacementPlace the display unit in a dry area free of dirt and dust. The display is magnet mountable. For wall mounting, hang using the keyhole located on the back of the unit.

Sensor PlacementSensor #1 should be placed in the REFRIGERATOR. Sensor #2 should be placed in the FREEZER. Note: Both sensors will work in either location, however, the default alerts are based on the placement mentioned above.Each sensor is equipped with a spring-action clip with a rubber grip to securely attached to the edge of a glass or wire shelf (A).Each sensor also includes a detachable suction cup that can be used to attach the sensor to the interior surface of the refrigerator (B). Please note: suction cups do not adhere well to freezing surfaces.Display unit and sensors must be located within 75 ft (23 m) of each other.

OPERATION

Using the Thermometer

High & Low RecordsThe thermometer records high and low-temperature records for each sensor. These readings reflect the highest and lowest temperatures recorded since the batteries were inserted or since the CLR button was last pressed.To reset the High/Low records, press and release the “CLR” button once. This clears the records from both sensors.

Programmable AlarmsProgrammable alarms notify you audibly and visually when temperatures exceed your preset minimum / maximum temperature range. An alert is triggered when a temperature is out of range for longer than 15 minutes. This prevents false alarms due to the fridge/freezer door being held open while new items are being loaded/unloaded.

The default temperature alarm settings for Sensor #1 (refrigerator thermometer) are minimum 33ºF / maximum 40ºF. The default temperature alarm settings for Sensor #2 (freezer thermometer) are minimum -22ºF / maximum 0ºF.

To customize temperature alarms:

  1. Press and HOLD the ” ” button until the current temperature disappears and the maximum temperature alarm setting is shown in its place.
  2. Press the ” + ” or ” -­ ” buttons to increase or decrease the maximum temperature alarm setting.
  3. Press the ” ” button to confirm the maximum temperature alarm setting. The unit will beep and the minimum temperature alarm setting will be shown.
  4. Press the ” + ” or ” ­- ” buttons to increase or decrease the minimum temperature alarm setting.
  5. Press the ” ” button to confirm the minimum temperature alarm setting.
  6. Press the ” ” button to turn ON/OFF the alarm. The “” display indicates that the alarm is ON.

For Alarm #2, repeat steps 1 through 5 using the ” ” button.

NOTE: When the thermometer is in normal operating mode (not in alarm setup mode), the High/Low readings display the highest/lowest temperature recordings.

Troubleshooting

Temperature is showing “E”or dashes  • Relocate the display and/or the sensors.The units must be within 75 ft (23 m) of each other.• Flashing of the temperature is generally an indicationof wireless interference. Perform a hard reset to gaina strong connection between the units:1. Bring all 3 units together, side-by-side.2. Remove all batteries from all 3 units.3. Reinstall batteries in the thermometer display unit first.4. Reinstall batteries into sensor #1.5. Reinstall batteries into sensor #2.6. The display unit should read temperatures fromboth sensors almost instantly.
Inaccurate temperature  • Use standard alkaline batteries (or lithium batteries inthe sensor when the temperature is below -4ºF/-20ºC). Do notuse heavy-duty or rechargeable batteries.
Display screen not working • Check that the batteries are installed correctly.Batteries may need to be replaced.• Reset the display by pressing the RESET button, locatedon the back of the display unit.
Current Temperature reads “-H-” or “-L-” • Verify you’re within the measurable temperaturerange (-40ºF to 100ºF; -40ºC to 37ºC).

If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call(877) 221-1252 for assistance. 

Care & Maintenance

Clean with a soft damp cloth. Do not use caustic cleaners or abr

Specifications

TEMPERATURE RANGE -40°F to 100°F; -40°C to 37°C
WIRELESS RANGE 75 ft / 23 m(signal range is impacted by sensor location and may vary)
WIRELESS FREQUENCY 433 MHz
POWER Display Unit: 2 x AAA alkaline batteries Sensor #1: 2 x AA alkaline or lithium batteries Sensor #2: 2 x AA alkaline or lithium batteries
DATA REPORTING 90 second updates

FCC Information

This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:

  1. This device may NOT cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, There is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  •  Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
  1. This device may not cause interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation of the device.

Customer Support

AcuRite customer support is committed to providing you with best-inclass service. For assistance, please have the model number of this product available and contact us in any of the following ways:

(877) 221-1252

[email protected]24/7 support at www.AcuRite.com

  • Installation Videos
  • Instruction Manuals
  • Replacement Parts
  • Register your  Product
  • Support User Forum
  • Submit Feedback & Ideas

Limited One Year Warranty

At AcuRite, we proudly uphold our commitment to quality technology. Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase.We recommend that you visit us at www.AcuRite.com for the fastest way to register your product. However, product registration does not eliminate the need to retain your original proof of purchase in order to obtain warranty benefits.Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney. Transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which have received normal wear and tear, been damaged (including by acts of nature), tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose. Chaney expressly disclaims all liability for special, consequential or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Chaney further disclaims all liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of Chaney’s products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm or corporation is authorized to assume for Chaney any other liability in connection with the sale of its products. Furthermore, no person, firm or corporation is authorized to modify or waive the terms of this paragraph, and the preceding paragraph, unless done in writing and signed by a duly authorized agent of Chaney. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.For in-warranty claims: Chaney Instrument Co.965 Wells St., Lake Geneva, WI 53147

It’s more than accurate, it’s

AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on toPlan your day with confidenceTM.

www.AcuRite.com

©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.

Printed in China 00986A2 INST 102815

References

[xyz-ips snippet=”download-snippet”]


Posted

in

by