resideo Braukmann UMV500 Series Universal Under Sink Thermostatic Mixing Valve Installation Guide

resideo Braukmann UMV500 Series Universal Under Sink Thermostatic Mixing Valve

GENERAL

The UMV500-LF/U UMV Series Universal Under Sink Thermostatic Mixing Valve is intended for use in under counter and under sink applications. The UMV500 Universal Model is designed to be used as a three port design (touchless sink) or a four port design (two handle sink) with the addition of the 4 port adaptor (supplied with UMV500-LF/U).The UMV500-LF/U is used to prevent accidental scalding. The outlet water temperature must be properly adjusted by the installer using a thermometer to measure the outlet temperature at the faucet. A maximum outlet temperature of 110° F (43° C) is recommended.

FEATURES

  • Universal design allows flexibility in adapting to three port or four port applications.
  • Shipped with four port adapter.
  • Shipped with standoffs for easy mounting.
  • Integral check valves in hot and cold inlets.
  • Lockable hand wheel for tamper resistant temperature setting.
  • Lead Free (0.25% max. weighted average lead content)

UMV500-LF/U with 4 port adaptor

SPECIFICATIONS

  • Model: UMV500-LF/U Under Sink Mixing Valve.
  • Construction Materials:
    • Forged brass body and EPDM seals.
    • Stainless steel spring.
  • Working Pressure:
    • Minimum: 20 psi (138 kPa).
    • Maximum: 125 psi (861 kPa). Pressure difference between Hot and Cold inlets shall be less than 20%.
    • Connections: 3/8 in. (9.5 mm) compression-type fittings on end connections.
  • Valves: Integral check valves in both Hot and Cold ports.
  • Flow: Maximum flow: 4.3 Gpm (16.5 l/min) (Cv= 0.36)
  • Minimum flow: 0.25 Gpm (0.95 l/min)
  • Cold inlet temperature: 39°F – 80°F (4°C – 27°C)
  • Hot inlet temperature: 120°F – 180°F (49°C – 82°C)
  • Valve inlet temperature operating parameters:
    • The hot inlet temperature must be at least 18°F (10°C) higher than the mixed outlet temperature.
    • The cold inlet temperature must be at least 18°F (10°C) lower than the mixed outlet temperature.
  • Mixed Outlet Temperature: 80° – 120°F (27° – 49°C).
  • Approvals:
    • ASSE 1070 Listed
    • CSA Certified/Listed
    • IAPMO/UPC Listed
    • NSF61/372 Compliant

INSTALLATION AND TEMPERATURE ADJUSTMENT

Figure below shows a typical installation for the under sink mixing valve.

Typical Installation

The handwheel of the under sink mixing valve can be used as a tool to adjust the temperature setting as follows.

  1. The valve must be adjusted when installed. Turn on the hot and cold supply, then open the hot faucet served by the valve. Let the water run for several minutes to ensure maximum hot inlet temperature is reached.
  2. Remove the cap by pulling it off.Remove the Handwheel
  3. Use the cap upside down to adjust the outlet temperature with a thermometer under the faucet. Turn the hand wheel clockwise for cooler temperatures and counterclockwise for warmer temperatures.
    • Turn clockwise to decrease the temperature down to 80°F;
    • Turn counter-clockwise to increase the temperature up to 120°F.
  4. Replace the cap after adjustment to lock the setting.

Place handwheel on adjustment rod

Adjust temperature

Lock the Setting

MAINTENANCE

Test the valve annually to make sure that the internal parts operate properly.

  1. Turn on the hot faucet and run water for a few minutes, until the hot inlet temperature is at its maximum.
  2. Remove the cap by pulling it off.
  3. Use the cap upside down to adjust the outlet temperature with a thermometer under the faucet. Turn the hand wheel one-half turn clockwise for cooler temperatures and counterclockwise for warmer temperatures.
  4. Check the outlet water temperature with a thermometer to make sure that the temperature changed and the hand wheel turned without binding.
  5. When the correct outlet temperature has been reached, replace the cap to lock the setting.

Resideo Technologies, Inc.1985 Douglas Drive North, Golden Valley, MN 554221-800-468-1502

 

[xyz-ips snippet=”download-snippet”]