CO2 is a naturally occurring gas that emitted at great levels by human activity and it is one of several greenhouse gases in our atmosphere. CO2 only accounts for 0.03% of the fresh air. If you breathe high concentration COC , you may be at risk of carbon dioxide intoxication. Symptoms of carbon dioxide toxicity include headache, irregular heartbeat, nausea, unconsciousness, or even death.
A37 is a COz Monitor that measures COC concentration, temperature and humidity. This monitor is widely used in homes, shopping malls, offices, vehicles, stations etc.
Please read carefully and follow all warnings and precautions before using the device.
Open box inspection
Open the box and take out the device. Please check whether the following items are deficient or damaged and contact your supplier immediately if they are
A37 CO2 monitor: 1
Protective case: 1
User manual: 1
USB cable: 1
Safety information
Check the device and its accessories for any damage or anomaly before Do not use the device if the cover is damaged, or has any other malfunctions.
Please follow the operation
Please do not open the device case and modify the internal
Do not store or use this device in high temperature, high humidity, flammable, explosive and strong electromagnetic
Charge the monitor when m symbol is
Regularly use soft cloth and mild detergent to clean the case. Do not use abradant or
A37 complies with CE
This monitor has ABC (Automatic Baseline Correction) Do not use this monitor in closed environment where COz concentration remains relatively high.
Use specified adapter to charge the device. The adapter should comply with UL/FCC safety
Structure
Case 2: LCD screen Os: USB port @: Functional buttons
Symbols
No
Indication
No
Indication
1
Audio alarm ON/OFF
7
COC concentration
2
STEL/TWA/MAX
/MIN/AVG modes
8
COz concentration grading emoticon
3
COC calibration
9
Relative humidity
4
Timing shutdown
10
Date/time
5
Battery status
11
Temperature
6
Exit calibration
12
Data hold
Operation instructions
Functional buttons
The following table shows the buttons functions in different modes.
Modes
Functions
Buttons
OFF
Long press: turn on/off the monitor
Long press: enter calibration mode
Measure
Short press: turn on/off the backlight
Short press to switch temperature unit ”C/”F
Long press to turn on/off audio alarm
Short press: cycle switch between HOLD/MAX/MIN/AVG/TWA/STEL
Long press: reset to zero
Long press: calibrate the CO2 concentration
(outdoor fresh air)
Calibration
Short press: increase the value
(double press to enter date/time calibration)
Long press: save
Short press: decrease the value
Short press: previous parameter
Long press: exit calibration
Operations
COz measurement
Long press @ to turn on the monitor. It takes 120s to stabilize COz concentration. CO2 concentration, ambient temperature, relative humidity will be displayed on the screen. COz concentration value is refreshed every 3 seconds.
Note: if CO2>1000ppm, buzzer goes off with red backlight flashing. The audio alarm’s default setting is OFF, long press @ to turn on the audio alarm.
Concentration grading emoticons
400ppm – 450ppn;
450ppm – 700ppn;
700ppm – 1000ppm ;
1000ppo – 2000pp«i;
2000ppm – 5000ppm ;
> 5000ppm
Data: Short press MODE to cycle switch between HOLD/MAX/MIN/AVG/TWA/STEL values.
Symbol
Indication
Hold
Data hold
MAX
Maximum value
MIN
Minimum value
AVG
Average value
TWA
Time weighted average
STEL
Short-term exposure limit
TWA: The average exposure within the workplace to any hazardous contaminant or agent using the baseline of an 8 hour day or 40 hours week work schedule.
STEL: The acceptable exposure limit to a toxic or irritant substance over a short period of time (time-weighted average), usually 15 minutes.
Auto shutdown: The monitor will automatically shut down if there is no operation for 2 hours.
Backlight: Please refer to Operation Instructions-Functional Buttons
Audio alarm: Please refer to Operation Instructions-Functional Buttons
Temperature unit: Please refer to Operation Instructions-Functional Buttons
Battery: Charge the battery when is displayed on the screen. It takes 2-3 hours to fully charge the battery.
Calibration
Date/Time
In shutdown state, long press and press twice. Increment and decrement are done throught the buttons and .
Long press the @ button to confirm. Long press @ + @ to exit setting mode.
COz
Note: COC function has been calibrated before delivery. If the value is greatly deviated from the standard, you can calibrate it by either methods below:
Automatic calibrationA37 has the built-in self-correcting ABC (Automatic Baseline Correction) algorithm to automatically adjust the base value.
Turn on the monitor and leave A37 at a place where there is flowing fresh air for 3 days (powered by the adaptor)
ABC function will automatically adjust and correct the CO2 standard value.Warnings: ABC function is always on, do not use this monitor in closed environment where COC concentration remains relatively
Manual calibration
Turn on the monitor, leave it outdoor for 20 minutes
Long press until appears on the screen. Calibration takes 10 symbol disappears when calibration is done.symbol disappears when calibration is done.
Note: It is suggested to calibrate the monitor in outdoor environments where there is air flow. Keep device away from animals, plants and human.
Specifications
Technical specification
Function
Range
Resolution
Accuracy
COC
400-5000 ppm
1ppm
+(5% of rdg+50ppm) from 400-2000ppm *1
Temperature
-1o.o“c-50.0”C
0.1”C
+1”C *2
Humidity
o-99%RH
1%RH
(10%RH 90%RH)
+5%RH @25”C
Measure environment: 1atm, ambient temperature and humidity “
It may be influenced by heat emitted by the adaptor.
General specification
Specifications
Descriptions
Sensor
NDIR principle
ABC
Automatic baseline correction
Audio alarm
Buzzer
Visual alarm
Red backlight
Display
LcD screen
Low battery indication
Auto power off
Backlight
Operating environment
0’C-50‘C, 0%RH-85%RH
Storage environment
-20”C-60”C, 0%RH-95%RH
Power supply
Built-in 3.7V DC rechargeable battery
Weight
195g
Dimension
75mm x 55mm x 130mm
CO2 concentration and effects (only for reference)
Concentration
Effect
350-450ppm
Fresh air
350-1000ppm
Normal
1000-2000ppm
Turbid air, sleepy
2000-5000ppm
Headache, irregular heartbeat, nausea
>5000ppm
Unconsciousness or even death
Maintenance
a.The maintenance and service of the device must be implemented by qualified professionals or the designated departments.
b.Regularly use dry cloth to clean the cover. Do not use the detergent containing solvent composition
c.To conserve battery, please turn off the device if do not being used for a long time.
UNI-Trend TECHNOLOGY (CHINA) CO., LTD.
No6, Gong Ye Bei 1sr RoadSongshan Lake NAtional High- Tech Industrial Development Zone, Dongguan City, Guangdond Province, China