Introducing – Infrared Thermometer Check temperature maintaining safe distancing with the contactless thermometer.
MODEL: DN -998
BeSafeMedikit+91 9811609355https://www.besafemedikit.com
Non- ContactInfrared Thermometer
Product Life: 2 Year
Note: To ensure the correct use of this infrared thermometer, please read this manual carefully.
Product Description
This product is a non-contact medical infrared forehead thermometer for the professional measurement of human body temperature.
Fundamental
Anything above absolute zero radiates a certain amount of infrared ray energy, the infrared energy value radiated by different kinds of objects is different, but the infrared energy and wavelength can be used to judge the surface temperature value of the object. According to this principle, the temperature of the forehead can be accurately measured due to its constant temperature. And since the infrared intensity radiated from the forehead at the same temperature is different from that of other objects, such as water, there are at least two temperature models (body temperature and body temperature).
Product Features
- Ergonomic design, simple & generous appearance.
- Non-contact high precision, clean & sanitary measurement.
- Excellent adaptability to environmental, change & can be used in complex environments.
- One-click temperature switching, convenient & practical.
- Double 32 groups of memory storage, one-click query, simple & practical.
- Adjustment of temperature deviation to facilitate different user habits.
- Automatic shutdown function, no automatic shutdown operation within 20 seconds.
- Measuring method: Non-contact type
- Effective Distance: 3cm – 15cm
- Measuring Range: Human Model 32.0C – 42.9C (85.9F – 109.F)
- Display: Trichrome backlight
- Temperature unit: Celsius / Fahrenheit
- Auto power off: Within 20 seconds.
Advice For The 1st Use
In order to obtain stable and reliable measurement data, when the temperature changes greatly, the infrared measuring instrument of the human body should be placed indoors for15-20 minutes before use.According to the skin color, thickness, and human body parts, the measured temperature will be different, which is normal. The more exposed the human body part is, the greater the impact of environmental temperature is Do not expose the product to the sun or touch the water One-minute interval after two consecutive measurements.
The normal temperature range at different measuring positions
Measuring temperature |
NormMtempemtum°C |
MnomMtemperaWWF |
Anus | 36.6–38 | 97.8-100.4 |
oral cavity | 35.5-37.5 | 95.9-99.5 |
Armpit | 34.7-37.3 | 94.4-99.1 |
Ear | 35.8–38 | 96.4–100.4 |
People’s body temperature changes at different times of the day, but is also affected by another external environment, such as age, character,skin color and thickness, etc.
The normal temperature range at different ages |
||
Age | Normal temperature*C | At normal temperature |
0-2yemsold | 36.4-38.0 | 97.5 100.4 |
340yeamold | 36.1–37.8 | 97.0–100.0 |
11-65yearsold | 35.9–37.6 | 96.6 99.7 |
>65yearsold | 36.8-37.5 | 96.4–99.5 |
Technical Parameters
Measurement Methods |
Non-Contact |
|
Effective Distance | 3cm— 5cm | |
Measurement Range | Human Body Model | 32.0″C —42. 91C (85.9°F —109.2°F |
Object Mode | Or .– t–100
(32’F-212°F) |
|
Measurement Precision | Body Temperature | ±0. 2*C10. 4°F |
Object Temperature | ± 3.0°C/37.4°F | |
Resolution | 0.1°C/°F | |
Operating Conditions | 10t —40°C (50°F —104°F ) Rh‘.80% Non condensing | |
Storage Condition | -25r-55t (-13°F-131°F) RH-90°A Non-condensing | |
Power | AAA Dry Battery | |
Power Consumption | Off ModeClOuW | |
Working Mode-.530mW | ||
Low Power Instructions | VoltageS.2.5V | |
Memory | Double 32 Groups(Body Temperature, Object Temperature) | |
Display | Three Colors Backlighting | |
Temperature Unit | Celsius, Fahrenheit | |
Auto Power Shut Off | 20 Seconds | |
Dimension | 138x95x45mm | |
Net Weight | 86g | |
Meet Standard | EN60601-1, EN 12470-5 , ASTM 1965-98 |
Product Illustration
1. Display | 1. Setting key |
2. Handheld position | 2. Temperature unit |
3. Infrared sensor | 3. Measuring button |
4. Choice mode | 4. Battery Installation |
LCD Indicator
Function definition |
Icon |
Detailed description |
|
Battery level indication | Light | The battery needs to be replaced due to insufficient power | |
Twinkle | Low power, the battery needs to be replaced | ||
Disappear | Enough electricity, everything is normal | ||
Measurement mode | Temperature | body temperature model | |
Object temperature | Material temperature model | ||
Temperature unit | °C | Centigrade | |
°F | Fahrenheit degree | ||
Temperatur value | Measured temperature value | ||
OPEN |
No. |
Name of Button |
Description |
1 | Temperature Unit | Switch between Celsius and Fahrenheit |
2 | Memory Button | View recently saved measurement data |
3 | Body Tmemperartautruerte/Object temperature | Temperature/temperature switch |
Instructions
Temperature modePress the measurement key to start the machine, and the machine will self-check. Normally, all symbols will be displayed. Figure 1O-1) at this time, the machine will automatically measure the ambient temperature and display the ambient temperature (10-2). Make sure that the machine can be tested once in the temperature mode At this time, the measurement is completed and the results are displayed as shown In Figure 10.4). At this time, you can read the data according to the displayed results to determine whether the temperature is abnormal lithe machine is not operated within 15 seconds after measurement, it will automatically shut down
Note:
- Keep the head of the sensor clean and do not cover the front with anything
- In order to ensure the accuracy of measurement, it is recommended that when you enter a new environment where the temperature changes greatly, wait for ten minutes before measuring
- When the temperature of a very high or very low object is measured, wait for ten minutes before measuring the temperature
Sweat and stains on the forehead will affect the accuracy of measurement. Do not measure the body temperature within 30 minutes after eating, bathing, and exercise
Battery Replacement
When the battery symbol is displayed on the screen, please replace the battery, otherwise, the measurement result will be affected. Open the battery cover, take out the exhausted battery, put 2 AA dry batteries, please pay attention to the battery polarity, do not put reversely.
AS Notes:
- Please take out the battery when not used for a long time;
- Please do not throw exhausted batteries into the fire;
- Dispose of used batteries in accordance with local laws and regulations.
Usage Tips
- Please read this instruction carefully before use;
- The ambient temperature of this product is 10°C-40°C, and the best temperature is 25°C;
- Please do not use this product in an environment higher than 40°C or lower than 0°C;
- Please keep the product away from electrified objects to avoid electric shock; -Please do not use the product in an environment where the relative temperature is greater than 80%;
- Please do not put this product too close to the electromagnetic range (such as radio, mobile phone, etc.);
- Please do not expose the product to the sun or near the stove, and do not touch the water; -Please do not shoot down or drop this product. If it is damaged, please do not use it;
- Hair on the forehead, sweat, a hat, or scarf can affect the accuracy of the measurements; -Please make sure the measuring distance is not greater than 15cm;
- In order to obtain accurate, stable and reliable measurement data, when the room temperature changes greatly, the thermometer should be placed in the room for ten minutes after use;
- When the forehead is sweating or other reason causes forehead temperature to be unable to reflect body temperature normally, can measure from earlobe hind; -When cleaning, please wipe the surface of the device with alcohol. In the event of a problem with the product, contact the distributor and do not attempt to repair it yoursiglim:Please keep this product out of the reach of children.
Q&A
Description |
Solution |
LCD display “LO” or HI” | 1. Wind, water vapor, sweat, Cosmetic may affect measurement results2. Set the temperature deviation value3. Large changes in ambient temperature4. The measurement distance is too far |
The measurement key is not responding | 1. Reinstall the battery
2. Whether the machine is under measurement |
No display or error | 1. Reinstall the battery |
No sound | 1. Make sure the sound switch is On |
Shut down after measurement | 1. Check if the battery level is sufficient |
Sign Description
Rated voltage 3.0V
Contact Us
Whether you’re interested in bulk purchase, or in manufacturing your own private label, you’re in the right place.For Bulk/OEM/Retail Enquiries, Contact Us: BeSafeMedikitWhatsapp: +91 9811609355,Email: [email protected]Website: https://www.besafemedikit.com
[xyz-ips snippet=”download-snippet”]