TOOL & HARDWARE

Required Installation Hardware

1/2” Type B Screw 2
1/4” Type B Screw 2
Main Bracket 1
Right Extension Arm(For 26”-36” windows) 1
Right Extension Arm – Short(For 22”-26” windows) 1
Main Support Pin 2
Cotter Pin 2
1/2” Type A Screw 3
Open Window Bracket – RH 1
Open Window Bracket – LH 1
Side Arm Foam 2

Optional Installation Hardware

Window Sash Lock 1
Thick Window Sash Seal Foam 1
Thin Window Sash Seal Foam 1
Miscellaneous Sealing Foam 1
Additional Side Arm Foam 2
1” Type A Screw 2

WARNINGDo not use any devices or materials for installation that are not recommended in this manual.

WINDOW REQUIREMENTS

INSTALL THE SUPPORT BRACKET

WARNING• Bracket should only be used for its intended purpose. If not, the warranty will be voided.• You must follow the detailed installation instructions in the user manual.

INSTALL THE SUPPORT BRACKET (cont.)

1.3 Secure the bracket to the window with a screw at the end of each extension arm as shown. Holes at the end or bottom of the Extension Arms can be used to secure the Support Bracket to the window.

SECURE THE UNIT ON THE BRACKET

2.1 Set the air conditioner on the support bracket and fold down the sidearm hinges. WARNINGDo not leave the unit unattended during installation.

2.2 You must install the Open Window Brackets. WARNINGFailing to do this could cause injury or property damage.

SEAL AND CLOSE THE WINDOW

3.1 Measure, cut and install the side arm foam. WARNINGDo not leave the unit unattended during installation.

3.2 Secure the anti-tip brackets into the window track and then close the window.

WARNINGYou must extend the Anti-Tip Brackets into the Window Track Opening. Failure to follow this warning may cause serious injury.

3.3 Use the included foam to seal any gaps between the window and the air conditioner.3.4 Extend both window locks located in the window slot. For additional security, install the window sash lock.FAQ Why does the air conditioner not start?

  • Wall plug disconnected. Push plug firmly into a wall outlet.
  • House fuse has blown or circuit breaker tripped. Replace the fuse with time delay type or reset circuit breaker.
  • Check if the light on the plug is on. If it is off, press the RESET button.
  • Power is OFF. Turn power ON.

FAQ Why is there noise during cooling?

  • It is normal to hear airflow, set to a slower fan setting if too loud.
  • Window vibration – poor installation. Refer to installation instructions or check with the installer.

FAQ Unit will not connect to Wifi or App does not work?For additional support and troubleshooting tips, follow the link in this QR code.