DEHUMIDIFIEROPERATING INSTRUCTIONS FOR: MRD20GW/MRD25GWVisit woods.se for more information and updated instruction manuals.For an extended warranty register your product at warranty-woods.com
Operating Instructions
RE Declaration of Conformity (DoC)
Unique identification of this DoC: Woods Production Sweden ABWe, Wood’s declare under our sole responsibility that the product:Product name: MRD20GW, MRD25GWTrade name: Wood’sType or model: MRD20GW, MRD25GWRelevant supplementary information: N.A.
To which this declaration relates is in conformity with the essential requirements and other relevant requirements of the RE Directive (2014/53/EU.)
The product is in conformity with the following CE standards and/or other normative documents:
CE LVD:EN 60335-2-40: 2003 + All: 2004 + Al2: 2005 + Al: 2006 + A 2: 2009 + Al3: 2012, EN 60335-1: 2012 All: 2014 + A13: 2017, EN 62233: 2008
CE EMC:EN 55014-1:2017, EN 61000-3-2:2019, EN 61000-3-3:2013+Al:2019, EN 55014-2:2015
REDEN 55014-1:2017, EN 55014-2:2015, EN IEC 61000-3-2:2019, EN 61000-3-3:2013+Al:2019, EN 301 489-1 V2.2.3, Draft EN 301 489-17V3.2.2
EN 300 328 V2.2.2, EN 62311:2008Limitation of validity (if any): N.A.Supplementary information: N.A.Notified body involved: N.A.The technical file held by: XXXXPlace and date of issue (of this DoC): XXXXSigned by or for the manufacturer
WOOD’S ONE OF THE WORLD’S LEADING DEHUMIDIFIERS
Wood’s dehumidifier has been known as the market leader for many years. Their dehumidifiers are suitable for use in the most demanding climates, where dehumidifying capacity is good even at different temperatures and humidity levels. They are used with good results in premises that become damp such as cellars, garages, or summer houses. They are also excellent for drying washing, attics, pool rooms, and laundry. Being efficient and low on energy consumption. Do not wear out clothes.
The amount of humidity that the dehumidifier removes depends on the temperature, humidity level, and placement. External weather conditions may also affect the performance of the dehumidifier. Wood’s dehumidifiers are safe in operation and intended for use over many years.
EXCESSIVE AIR HUMIDITY – A DANGER
Condensation occurs when water vapor in the air comes into contact with a cold surface such as a cold window or wall. When water vapor is cooled down, condensation occurs and water drops are formed. In high air humidity, the air may get musty and mold might get formed, causing damage to a house and its furnishings. This environment may even cause illness for the residents. Mites and spiders also thrive in damp environments. A dehumidifier with high performance creates a good, healthy humidity level. For the greatest efficiency, the doors and windows of rooms that are being dehumidified should be kept closed. Removes odors, dries wood, and removes moisture from outdoorsequipment.
SECURITY WARNINGS
Flammable material. This appliance contains R290/ Propane is a flammable refrigerant.
Refer to this manual for safety information.
Read technical manual
Read operators manual.
SAFETY INFORMATION
Before the installation and use of the appliance, carefully read the supplied instructions. The manufacturer is not responsible if an incorrect installation and uses cause injuries and damages. Always keep the instructions with the appliance for future reference. Children and vulnerable people safety
WARNING Risk of injury or permanent disability.This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.Do not let children play with the appliance.Children of less than 3 years should be kept away unless continuously supervised.Keep all packaging away from children.Cleaning and user maintenance shall not be made by children without supervision.
General SafetyThis appliance is intended to be used in households and similar applications such as – basements, crawl spaces; staff kitchen areas in shops, offices, and other working environments. The rating plate is located at the back or the side of the dehumidifier.
Keep ventilation openings clear of obstruction.
Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
The appliance shall not be stored in a room with operating ignition sources (for example; open flames, an operating gas appliance or an operating electric heater. Do not pierce or burn.
Be aware that refrigerants may not contain an odour. Do not use water spray and steam to clean the appliance. Clean the appliance with a moist soft cloth. Only use neutraldetergents. Do not use abrasive products, abrasive cleaning pads, solvents or metal objects. If the supply cord is damaged, it must be replaced by the manufacturer, its Authorised Service Centre or similarly qualified persons in order to avoid a hazard.
SAFETY INSTRUCTIONS
Installation
WARNING
Always be careful when you move the appliance because it is heavy. Always wear safety gloves. Make sure the air can circulate around the appliance.
Wait at least 4 hours before connecting the appliance to the power supply. This is to allow the oil to flow back in the compressor. Do not install the appliance close to radiators or other heat sources. Do not install the appliance where there is direct sunlight.
Electrical connection
WARNING
Use
WARNING
Disposal
WARNING
SET UP DEHUMIDIFIER FOR INSTALLATION IMPORTANT:
Installation
BEFORE FIRST USELet the machine stand for 4 hours before useSelecting a Location
Important
- Dehumidifiers must be operated in an enclosed area to be most effective. Close all doors, windows, and other openings to the room. The effectiveness of the dehumidifierdepends on the rate at which new moisture-laden air enters the room.
- Place a dehumidifier in a location that does not restrict airflow through the front of the unit.
- A dehumidifier operating in a room will have little or no effect in drying an adjacent enclosed storage area, such as a closet unless there is adequate circulation of air in and out of the area. lt may be necessary to install a second dehumidifier in the enclosed area for satisfactory drying.
- Ensure that the unit is placed on a stable and flat surface. If the surface is not stable there is a risk that the unit may be unstable and cause excessive vibration and that waterwill be released.
- The dehumidifier must have at least 20 cm free space around the entire dehumidifier.
PRODUCT DESCRIPTION
Product description
A
- Handle
- Control panel
- Top lid
- Swing function
- Front case
B
- Air plate
- Continuous drain pipe
- Power cord
- Back casing
- Water tank
C Control Panel
- Display function
D Picture D (Picture of symbols on the control panel)
- Power button: This button can control the machine on/off.
- Mode button: This button can set the machine to work under dry mode or dehumidification mode.(during dry mode, it dehumidifiers continuously under the highest speed)
- Humidity button: During the dehumidification mode, this button can set different desired humidity and the range is 50-55-60-65-70-Co-40-45-50-55-60-6570%RH.
- Timer button: During operation, if you press this button for <0.5 seconds it can set a timer off function 0H/1H/2H/3H/4H/5H/6H/7H/8H to operate a countdown.
- Fan speed button: This button can set the machine to work at low speed or high speed.
- Swing button: This button can set the machine to swing or not swing automatically.
- Defrost active
- Water bucket full
- Child lock: If press the timer button for 3 seconds it can set the child lock function on or off. During the child lock function, only timer and on/off buttons can be set. Just press this button for 3 seconds again to switch off the child lock function.
E
TOP AND BUTTON
- Sketch on the top and underneath themachine
F
- The dehumidifier must have at least 20 cm free space around the entire dehumidifier.
F
- The dehumidifier must have at least 20 cm free space around the entire dehumidifier.
G
- Based on combining the same model with or without WIFI, the unit’s humidity settings and display are Co, 40%,45%,50%,55%,60%,65%, and 70% RH, while the apps settings and display are 35%, 40%, 45%, 50%, 55%, 60%, 65%, and 70% RH. Also note, the unit’s display shows humidity from LO, 30, 31, 32…79,80, and HIGH, but the app just can
- During “dry mode”, both the product and app can not set the fan speed, as it works only on the highest fan setting.
PLACEMENT OF DEHUMIDIFIER
– The dehumidifier should not be placed near radiators or other heat sources or exposed to direct sunlight, as it will reduce performance.– Ideal is to put it in the center of the room/area.
NOTE: When placed in a shower room or bathing area, the dehumidifier should be fixed in place. It is compulsory to check and respect your local bathroom electrical regulations before use.
USING THE DEHUMIDIFIERIf the dehumidifier is transportedhorizontally, let the dehumidifier standfor a 4 hours before being used. It is veryimportant that the oil runs back into thecompressor, otherwise the dehumidifiermay be seriously damaged.
- Check that the water reservoir is correctly placed.
- Connect the dehumidifier to a grounded power source.
- Set the desired humidity level by means of the humidity control. See the section on humidity control.
NOTE: The ambient relative humidity can be simply measured with the dehumidifier.
OPERATION MANUAL
- Power Button: This button can control the machine on and off.
- Humidity button: To set the desired humidity. press the Humidity button for 5s, it shows ambient temperature (0~40°C) for 5s; if you press and hold the Humidity button, it shows ambient temperature all the time. If you don´t press again it automatically shows the NTC sensor temperature for 5 seconds then, shows ambient humidity.
- Humidity Settings: Open the air outlet set humidity between 40%, 50%, 60%, or continuous mode.
- Timer: When the appliance is on, press the Timer 2H/4H/6H to operate a countdown.
- during operation, it shows ambient humidity from 30,31,32···79,80. If it is <. 30%RH, it shows LO; if it is >80%RH,
- In dehumidification mode, you can set humidity level and fan speed 2 levels
MEMORY FUNCTION
- Press the on/off button (plugged into a power socket) and then press the on/ off button again, it works following the previous setting, but the timer and child lock function has no memory.
- No power when operation equals to plug off all of a sudden the machine works automatically when there is power and it memories previous setting, but child lock function has no memory.
- The unit will automatically turn on and operate in the last setting after power returns. It works under the initial default setting during dehumidification mode and works under humidity setting by 50%RH on high speed.
COMPRESSOR PROTECTION FUNCTIONThe unit is equipped with a compressor protection function—that is, the compressor has five minutes period between starts operation and shut down.
WATER DRAINAGEWhen the water reservoir is full, the dehumidifier is shut off automatically. Once the water reservoir is emptied the unit will automatically restart.
- Disconnect the dehumidifier from the power source.
- Empty the water reservoir.
- Put the empty water reservoir back and check that the float moves freely.
- Connect the dehumidifier to the power source.
Direct water drainageConnect a water hose to the pipe on the back of the dehumidifier. Lead the other end to a drain. Make sure that the water can be drained downwards.
AIR FILTER The air filter prevents dust and dirt from entering the machine, prolonging its life expectancy. It is important the filter is cleaned regularly.
Filter cleaning:
- Remove the filter.
- Wash it with warm water and a mild cleansing agent. Alternatively, the filter may be vacuum cleaned.
- Let the filter dry and put it back.
DEFROSTING OPERATION
During the defrosting operation, the dehumidification function may intermit.Please don’t turn off the switch or pull out the power plug of the dehumidifier during the defrosting operation. This dehumidifier can’t be applicable to keep extremely low temperatures.The purpose of this dehumidifier is to pump off the unpleasant high humidity in daily life and dry the wet things. But it can’t be used to keep extremely low temperatures.The room temperature increases during the operation.This dehumidifier doesn’t have a colling function.It will produce heat during the operation and increase the room temperature to 1 to 4°C. In addition, the door and windows are closed and other appliances in the room can give out heat as well as the radiation of the sun can raise the room temperature.
MAINTENANCE AND CLEANING
For its casing is made of plastic, do not place it in direct sunlight. Remove the water tank with care. If not using the unit for a long time. Please Switch off and unplug the unit,empty the water reservoir, keep it in a dry and ventilated place. Only use a soft clean cloth for all cleaning purposes. Do not use gasoline, paint thinner or other chemicals to clean the unit. Cleaning mesh filter: Remove the filter using a vacuum cleaner or water to clean, then put it in ventilated place until it’s dry.
SERVICE
If the dehumidifier requires servicing, you must first contact your local retai- ler. Proof of purchase is required for all warranty claims.
STORAGE
Before storage of the unit, please follow these steps:
- Make sure the water tank is empty.When the unit is switched on, make sure the unit work at Ventilation mode for at least 30 minutes to remove the water inside the unit.
- Collect and bundle the power cord.
- Clean the filter.
- Store in a clean, dry environment.Proof of purchase is required for all warranty claims.
HINTS
When the dehumidifier is used in extremely damp environments or when the temperature is below +5˚C, the dehumidifier may stop working. A large amount of ice builds up on the cooling coil. Turn off the dehumidifier and place it a little above floor level so that the ice will melt away.
Sometimes it may be useful to use a frost guard or heater fan to make sure that the temperature does not fall below +10˚C. Even if the MRD20/25 work down to temperatures as low as +5°C, its capacity will increase at higher temperatures as warm air carries more water.
The hydrostat has a margin of error of approx. +/- 5-10%. At lower temperatures, the margin of error might increase further. For maximum dehumidifying power in a room, it is recommended that the air supply from outside and from adjoining rooms is minimized – close doors and ventilators.
Expect higher dehumidification capacity during Autumn / Summer because the outside air is warmer and more humid.
IMPORTANT! – Wood’s dehumidifier must be connected to a grounded power source. The power source should be 220V-240V 50Hz
PROBLEM | CAUSE | REMEDY |
The dehumidifier does not work | The power is not connected |
Check that dehumidifier is connected to electricity and that fuse has not gone. Check that the water reservoir is empty and correctly placed in the dehumidifier. |
Does not dehumidify | The water container is full.
The water container has not been replaced correctly. The air filter is clogged. The temperature or relative humidity in the room where the device is operating is too low. |
Remove the water from the container. Place the water container in the correct position. Clean the air filter. Check that air can flow freely through the dehumidifier. The front grid and air filter should be clean and the dehumidifier should stand 20cm from the wall. |
The dehumidifier works but reduces the relative humidity insufficiently. | The room is too large.
There are too many sources of humidity. There is too much ventilation |
We recommend using a dehumidifier with a larger capacity. We recommend using a dehumidifier with a larger capacity. Reduce ventilation(e.g close windows and shut doors) |
If you are having trouble with your dehumidifier please refer to the troubleshooting. If none of these works, please contact your retailer for servicing of your dehumidifier. |
Guarantees
2 years consumer warranty against production faults. Please note that the warranty is only valid upon the production of the receipt. The warranty is only valid if the product is used in accordance with the instructions and security warnings expressed in this manual. The warranty does not cover any damages caused by improper handling of the product.
NOTE: The 2 years warranty only applies to consumers and not for commercial use of the unit.
TECHNICAL DATA
MRD20 | |
Max. working area | 70m2 |
Airflow | 175m7h±10% |
Dehumidifying at 30°C and 80% r.h. | 201/24h |
Power at 30’C and 80% r.h. | 280 W±10% |
Tank volume | 3,8 liters |
Refrigerant | R290 |
Charge R290 | 60 g |
Voltage | 220-240V |
The noise level in decibels | 48dB |
Weight | 15,5 kg |
Dimensions in mm, L x Bx H | 355x252x567 |
MRD25 | |
Max. working area | 120m2 |
Airflow | 180m3/h±10910 |
Dehumidifying at 30°C and 80% r.h. | 251/24h |
Power at 30°C and 80% r.h. | 380 W±10% |
Tank volume | 3,8 liters |
Refrigerant | R290 |
Charge R290 | 85 g |
Voltage | 220-240V |
The noise level in decibels | 48dB |
Weight | 16kg |
Dimensions in mm, L x Bx H | 355x252x567 |
NOTE!Register at www.warranty-woods.com and read about how to get an extended warranty. Please visit www.woods.se for more information.Recommended limits for use Temp. +5˚C to +35˚C Relative humidity: 30% to 90% Recommended humidity level: appr. 50% RH
*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as temperature, ventilation, and humidity.
Wood’s is marketed and distributed by:Woods Production Sweden AB.Maskingatan 2-4441 27, AlingsåsSweden.woods.se[email protected]+46 317613610
Visit our website to:Get usage advice, updated brochures, troubleshooter andservice information.Register your product for additional services:www.warranty-woods.com
CUSTOMER CARE AND SERVICE
Always use original spare parts.When contacting our Authorised Service Centre, ensure that you have the following data available: Model number, receipt and serial number.
Warning / Caution-Safety information.General information and tips.Environmental information.Subject to change without notice.
References