ECOFLOW 50024071 RIVER 600 Max Portable Power Station User Guide

User Guide

EcoFlow RIVER

WARNING

  1. Keep EcoFlow RIVER MAX 600 (hereinafter referred to as RIVER MAX) and the accessories dry. DO NOT expose the product and accessories to high heat.
  2. Never disassemble, puncture, shock, damage, or incinerate the product.
  3. Recycle and dispose of RIVER MAX in accordance with local laws and regulations.
  4. Pay attention to safety when handling the RIVER MAX.
  5. People living with disabilities or children should use the product under the protection of a supervisor. under the protection of the supervisor.

Glossary

The following terms are used in this document to indicate various levels of potential harm that may be caused by improper operation.NOTICEThe instructions, if not properly followed, may result in property damage and minor physical damage.CAUTIONThe instructions, if not properly followed, may result in property damage and serious physical damage.WARNINGThe instructions, if not properly followed, may result in property damage, major accident, and serious injury.

WARNINGRead the ENTIRE user manual to be familiar with the features of this product before operating. Failure to operate the product correctly may result in damage to the product or personal property and cause serious injury. EcoFlow will not assume any legal responsibility. DO NOT use the product with incompatible components or alter the product in any way without following the instructions provided by EcoFlow. Failure to follow these instructions will render EcoFlow after-sales services and the productwarranty void. These Safety Guidelines include instructions for safety, operation, and maintenance. It is important to read and follow all the instructions and warnings in the user manual before assembly, setup, or product use.

Product Safety Guidelines

WARNINGImproper use may result in fire, property damage, or personal injury. Make sure to use the product ac- cording to the following safety rules and guidelines.

Product Use:

  1. DO NOT expose the product to any liquids. Do not immerse the product in water. DO NOT leave the batteries out in the rain or near a source of moisture. Moisture in the device could cause short circuits, component failure, fires or even an explosion.
  2.  Never use non-EcoFlow parts. Go to http://www.EcoFlow.com to purchase new parts. EcoFlow takes no responsibilityfor any damage caused by the use of non-EcoFlow parts.
  3. Never install or remove other modules from the RIVER MAX when it is turned on. DO NOT plug or unplug other modules when the power of the product is turned on, otherwise, the power interface may be damaged.
  4.  The product should be used in temperatures between -4ºF and 140ºF (-20°C and 60°C). The use of the product in environments above 140ºF (60°C) may cause fires or explosions. The use of the product below -4ºF (-20°C) will severely affect the performance of the product. Allow the product to return to a normal operating temperature before using it.
  5. DO NOT use the batteries in strong electrostatic or electromagnetic environments. Otherwise, the battery control board may malfunction and cause a serious accident during use.
  6. Never disassemble or pierce the product in any way. Otherwise, it may leak, catch on fire, or explode.
  7. DO NOT use the product if it was involved in a crash, accident, or heavy fall.
  8. If the product falls into the water during use, take the product out immediately and put it in a safe and open area. Keep a safe distance from it until it is completely dry. Never use it again and dispose of it properly as described in the Battery Disposal section below. If the product catches fire, it is recommended to use fire extinguishing equipment in the following order: water or water mist, sand, fire blanket, dry powder fire extinguisher, and a carbon dioxide fire extinguisher.
  9. DO NOT put the device in a microwave oven or in a pressurized container.
  10. DO NOT allow pins, wires, or other metal pieces to enter the device case, outlets, or controls. Metal pieces may short circuit the product.
  11. Avoid collisions. DO NOT place heavy objects on the device.
  12. If there is dirt on any plug or outlet surface, use a dry cloth to clean it. Otherwise, it will cause abrasion and result in energy loss or the inability to charge the device.

Product Charging:

  1. Always use EcoFlow approved charging cables. EcoFlow does not take any responsibility for any damages caused by using non-EcoFlow charging cables.
  2. When charging, please place the product on the ground with no flammable or combustible materials aroundit. To prevent accidents, never leave the device unattended during charging.
  3. DO NOT charge the device immediately after a long heavy load, because the device temperature may get too high. DO NOT charge the device until it cools down to room temperature. The device may be unable to charge when it is out of the temperature range: 32ºF to 104ºF (0 to 40°C ). The ideal charging temperature range is 71ºF to 82ºF (22°C to 28°C ).

Product Storage and Transportation:

  1. Keep the product out of the reach of children. If any child accidentally swallows any parts, please go to a doctorimmediately.
  2. If a low-battery warning appears, charge the battery before storing it. Otherwise, long-term storage may cause damage to the battery. Batteries in the product will enter hibernation mode if they are depleted and stored for a long time. Recharging the product can bring the battery out of hibernation.
  3. DO NOT place the product near a  heat source, such as a car in direct sunlight, a fire source, or a heating stove.
  4.  Store the product in dry environments. Please keep the device away from water.
  5. Make sure no small metal objects can fall on or around the product while it’s being stored.
  6. Never ship a product with a battery power level higher than 30%.

Product Battery Disposal:

  1. Dispose of the product in specific recycling boxes only after a complete discharge. Batteries are hazardous chemicals. Please strictly follow your local regulations regarding battery disposal and recycling.
  2. Dispose of the product immediately if it cannot be powered on after over-discharging.Travel Notice:It is forbidden to carry lithium batteries above a specific capacity on airplanes due to flight regulations. Please check local flight laws and regulations. Do not bring this product on flights.

RIVER MAX Usage and Safety Guide

NOTICETo turn RIVER MAX on or off, you need to PRESS and HOLD the ON/OFF System Power Button. To turn on the AC power outlet, you need to PRESS and HOLD the AC Button after turning on RIVER MAX. The ACButton can be used to save power. Please follow this step-by-step introduction to understand RIVER MAX’s buttons, display screen, and more.Please fully charge (100%) RIVER MAX before using it.

FCC Statement:

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference that may cause undesired operation.

WARNINGChanges or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

NOTICEThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  1. Orient or relocate the receiving antenna.
  2. Increase the separation between the equipment and receiver.
  3. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  4. Consult the dealer or an experienced radio/TV technician for help.

FCC Radiation Exposure Statement:

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator & your body.

EcoFlow App Guide

  1. EcoFlow App Download GuideSearch for “EcoFlow” in Google Play Store or App Store to download the app. You can also scan this QR code with your phone, or you can enter the download link in your browser: https://ecoflow.com/pages/ecoflow-app
  2. For more information, please follow the instructions in the app or on our official website www.ecoflow.com.https://ecoflow.com/pages/r600-app-download

Features of the RIVER MAX

220-240V region*Dedicated AC Output*EcoFlow has designed different AC output sockets following the local regulations of different countries.

  1. LCD Display
  2. USB-A Output Ports
  3. ON/OFF Button of LED Light
  4. IOT Reset Button (PRESS & HOLD 3s to reset WiFi)
  5. USB-C 100W Output Port
  6. Power Button & LCD Display Screen
  7. DC Output ON/OFF Button (CarOutlet, 2 DC 5521 Output Ports) & DCOutput Indicator
  8. Fast Charge USB-A Output Port
  9. AC Power Button (PRESS for ON/OFF) AC Output Indicator
  10.  3 AC Output Sockets (100-120V version)2 AC Output Sockets (220-240V version)
  11.  Ventilation Fan
  12. X-STREAM Charging Input Port
  13. Overload Protection Switch
  14. Solar Charge/Car Charge Input Port
  15. Power Earth Screw
  16. *Ambient Light

Ambient Light

  1. Status Signals
    Powering up: The blue light will move from the middle to the sides of the panel.
    Powering down: The blue light will move from the sides to the middle of the panel.
    Charging: The blue light will move from left to right of the panel, repeatedly.
  2. Customizing the Ambient LightEnter Module Settings on the EcoFlow app to access ambient light features.• The ambient light can be turned on / off, kept on, or put on a standby mode.• Select the ambient light color.• Adjust the brightness of the light.• Select the lighting mode. (There are five unique lighting modes to choose from).

User Interface

a. Remaining Charge/Discharge TimeThis number indicates the remaining charge/discharge time (mins) for RIVER MAX.b. Battery Level IndicatorShows the remaining power. The icon rotates while charging.c. Battery Level PercentageShows the remaining power (%). If the display shows 0%, please charge RIVER MAX immediately.d. High-Temperature IndicatorWhen the temperature of the RIVER MAX is too high, a high-temperature warning icon appears on the screen. Please cool down the product before use.e. Low-Temperature IndicatorWhen the temperature of the RIVER MAX is too low, a low-temperature warning icon appears on the screen.Please warm up the product properly before use.f. Fan IndicatorShows the fan speed, which is controlled by RIVER MAX automatically.g. Current InputShows the current input power of RIVE in watts.h. Current OutputShows the current output power of RIVER MAX in watts.i. Overload WarningShows an overload icon when the unit is overloaded and indicates which module of the unit is overloaded.j. Port Usage IndicatorsIndicates the usage status of each port.

Protection and Error Information

The RIVER MAX display screen showcases different icons to indicate errors or prompts to help you protect your device. Read the information below to understand the icons and what to do when they appear.

 

OVERLOAD

 

 

USB-A Overload Protection

Icon(s): USB-A and OVERLOAD icons flash together. What to do: Disconnect all electrical appliances and wait 10 seconds before connecting each appliance again.

 

USB-C High-Temperature Protection Icon(s): USB-C and High-Temperature icons flash together. What to do: Let RIVER MAX 600 cool down before connecting the appliances.
OVERLOAD USB-C Overload Protection Icon(s): The USB-C icon and the OVERLOAD icon flash together.

What to do: Unplug the appliances, the unit will auto- matically resume operation after 10 seconds.

RECHARGING TIME

 

 

High-Temperature Recharging Protection Icon(s): Recharging Time, Battery Exclamation, and High-Temperature icons flash together.What to do: This happens when you charge your device immediately after using the unit heavily. Let RIVER MAX 600 cool down before recharging.

High-Temperature Discharging Protection Icon(s): Battery Exclamation and High-Temperature icons flash together.What to do: The power supply can be resumed after the battery is cooled down.

RECHARGING TIME

Low-Temperature Recharging Protection Icon(s): Recharging Time, Battery Exclamation, and Low-Temperature icons flash together.What to do: Place RIVER MAX in a warmer place before recharging.

 

Low-Temperature Discharging Protection Icons(s): Battery Exclamation and Low-Temperature icons flash together.What to do: Place RIVER MAX in a warmer place before turning the power back on.
RECHARGING TIME OVERLOAD

OverloadRecharging-protection Icon(s): Recharging Time, Battery Exclamation, and OVERLOAD icons flash together.What to do: Unplug the charging cables, restart the RIVER MAX 600, and plug back the charging cables back in. If the light keeps flashing contact customer service
OVERLOAD Overload Discharging Protection Icon(s): Battery Exclamation and OVERLOAD icons flash together.What to do: Disconnect all appliances, restart the RIV- ER MAX, and connect each of your appliances back in. Note: electrical appliances can only be operated within the specified power range.

—–

Communication Failure between the Main Board and BMS Icon(s): Exclamation icon flashes. What to do: Restart the RIVER MAX. If the icon keeps flashing, contact customer service. customer service
Light stays on Icon(s): Exclamation icon flashes.What to do: Restart the device. If the light stays on, contact customer service.
Communication Failure between the Main Board and AC Icon(s): AC icon flashes.What to do: Restart the RIVER MAX 600. If the icon keeps flashing, contact customer service.

OVERLOAD

Inverter Output Overload Icon(s): AC and OVERLOAD icons flash together. What to do: Wait 10 seconds, turn the AC power off. Please note that all electrical appliances must be operated within the specified power range. (For more information about specific appliance use and the X-Boost function, go to page 12).
 

 

Inverter High-Temperature Protection Icon(s): AC and High-Temperature icons flash together.What to do: Let RIVER MAX cool down. Turn the AC Power off; the unit will automatically recover.
Inverter Low-Temperature Protection Icon(s): The AC and Low-Temperature icons flash together.What to do: Move RIVER MAX to a warmer place and wait for the inverter to warm up. Turn the AC Power off; the unit will automatically recover. If it doesn’t, contact customer service.
Fan Blockage Icon(s): Fan icon flashes.What to do: Turn the RIVER MAX off, carefully clean the unit, and vacuum around the fan vents on both ends of the product. Turn the unit on, if the Fan Blockage icon keeps flashing, contact customer service
 

OVERLOAD

 

Car Charger Overload Icon(s): Car and OVERLOAD icons flash together. What to do: Restart RIVER MAX, make sure all electrical appliances are used within the specified power range.
Car Charger High-Temperature Protection Icon(s): Car and High-Temperature icons flash together.What to do: Turn off the unit and wait for RIVER MAX to cool down. The unit will automatically recover.

Connecting the Solar Panels

The RIVER MAX can support a 10-25V DC input. When the input exceeds 25V, the RIVER MAX overvoltage protection will be activated. Overvoltage may damage the product. Users should read these instructions carefully because any incorrect use of solar panels that leads to product damage will void the EcoFlow warranty.How to Recharge the RIVER MAX Using Solar PanelsFor full step-by-step instructions about how to connect RIVER MAX with solar panels, please refer to the Solar Panel User Guide.

1. Recommend Charging Method

Users can connect a solar panel as shown in Example 1. DO NOT attempt to connect more than one solar panel in a series.

  1. Connect to EF MC4 to XT60 solar charge cable. Connect the XT60 connector to the RIVER MAX’s XT60 input port to charge the device. Users can connect up to 2 sets of solar panels in parallel to the MC4 port as shown in Example below.
  2. If you want to connect 2 pieces of solar panels, connect them with our solar MC4 parallel connection cable.Con- nect the XT60 connector to the RIVER MAX’s XT60 input to charge the device. The parallel connection cable is an optional accessory that is purchased separately.Note: The EcoFlow Solar MC4 Parallel The connection cable is an optional accessory that needs to be purchased separately. The charging methods below are with respect to using the EcoFlow 110W Solar Panel.

Charging Method 1

Charging Method 2: (Parallel Connection Only)

SOLAR PANEL-21.6V X2

2. Connecting Third-Party Solar Panels to RIVER MAX

Users can buy their own third-party solar panels to power RIVER MAX, provided that the solar panels have a standard MC4 connection and the voltage and current (10-25V DC, 12A Max) comply with the specifications of RIVER MAX. The third-party solar panels will be able to recharge RIVER MAX through the MC4 to XT60 cable. EcoFlow does not provide free repair services for any damage to the power station caused by third-party products.

Entry-Level UPS

RIVER MAX Entry-level UPS Use Reminder

RIVER MAX’s X-Stream system supports an entry-level UPS function. You can use the RIVER MAX AC socket whilethe device is connected to a wall socket with an AC power supply (the AC power comes from the grid, not the battery). In the event of a loss of grid power, the RIVER MAX battery power will be activated automatically in <30ms to ensure a continuous flow of power. This is an entry-level grade UPS function that does not support 0ms switching.

Do not connect devices that have uninterrupted power supply requirements. Please perform multiple tests with data servers and workstations when connecting them to RIVER MAX. EcoFlow will not be responsible for any

Entry-Level UPS User Guide

Users can connect the AC charging cable of RIVER MAX to grid power, connect a device to RIVER MAX, and turn on the AC switch to automatically enter the entry-level UPS mode. When the external power is cut off, power will be supplied from the battery of RIVER MAX immediately to power your device (as shown below).*

UPS is only applicable to electrical appliances below 600W. Please do not use other equipment at the same time to avoid overloading the power station. EcoFlow is not responsible for any detrimental operations or data loss caused by careless use. Only one RIVER MAX can conduct the UPS function; the UPS function is not available when more than one RIVER MAX is connected together. Please follow the connection instructions below: AC X-Boost ModeThe EcoFlow X-Boost featured is recommended for use when powering devices between 600W-1200W. As a result, there is no need to buy additional devices in order to power different products. Traditional inverters will overload when one electrical appliance with a higher rated power is connected. Please take note of the following when using X-Boost:

  1. The X-Boost mode is enabled by default. You can use the EcoFlow app to turn this function on/off. Please do not connect the AC output to grid power when the X-Boost mode is on, doing so will activate the low-voltage protection of the power station;
  2. The X-Boost mode is not available when using a parallel connection or when charging;
  3. When using appliances with a rated power of 600W-1200W, please connect only one appliance. When connecting more than one electrical device, the change of voltage may affect the usage of other electrical devices.** The X-Boost mode is not applicable for all electrical devices. Some devices with a rated power of 600W-1200W that have strict voltage requirements are still not compatible. Please conduct a full test to confirm before usage. X-Boost is recommended for electrical equipment with heating elements and a rated power between 600-1200W, such as hair dryers, kitchen appliances, or tools.

Technical Specifications

General Specs

Net Weight 17 lbs (7.7kg)
Dimensions 11.3 x 7.3 x 9.96in (28.8 x 18.5 x 25.3cm)
Capacity 576Wh (28.8V)
Testing and certification UL Standard, CE, FCC, RoHS

Outputs

AC Output (x3) / (x2 International Version) Full Sine Wave 600W (Surge 1200W) total, 120Vac (50Hz/60Hz) / 230Vac (50Hz/60Hz)
USB-A Output (x2) 5V DC, 2.4A, 12W Max, per port
USB-A Fast Charge (x1) 5V DC, 9V DC, 12V DC, 2.4A, 28W Max
USB-C Output (x1) 5V DC, 9V DC, 12V DC, 15V DC, 20V DC, 5A, 100W Max
Car Power Output (x1) 136W, 13.6V DC, 10A Max
DC5521 Output (x2) 13.6V DC, 3A Max(per port)

Input

AC Charge Input Voltage 100-120Vac (50Hz/60Hz) International Version 220-240Vac (50Hz/60Hz)
AC Charge Input Power (Example 1)* X-Stream Charge 250W Max /500W Max (With Extra Battery
Solar Charge Input 200W, 10-25V DC, 12A max
Car Charger (Example 2) 12V/24V DC 10A max

Battery

Cell Chemistry Lithium-ion
Discharge Temperature* -4°F to 140°F (±5°F), -20°C to 60°C (±3°C)
Charge Temperature* 32°F to 113°F (±5°F), 0 to 45°C (±3°C)
Shelf Life 1 Year (after fully charging the device)500 Cycles
Cycle Life 500 Cycles (>80%)

* Please Note: The following information has been obtained under supervised test conditions.

How to Recharge RIVER MAX

RIVER MAX has an AC charging port and an XT60 charging port located on the side of the device. RIVER MAX can be charged with a 12V car charger, solar panels, or with AC power.<2 hrs0-80% charged in 1 hour0-100% charged in 1.6 hour(AC charging cable included)

Example 2:

<3 hrs0-100% < 3 hours(Car charge cable included)

Can RIVER MAX Power Devices and Charge at the Same Time?Yes, RIVER MAX can power devices at the same time as charging.

RIVER MAX FAQ

How to Clean RIVER MAXRIVER MAX is a versatile, durable power station that can be used in many types of applications. You can clean RIVER MAX using a dry, non-abrasive cloth. Use a phone or screen cleaning spray if you need to clean RIVER MAX more thoroughly. DO NOT expose RIVER MAX to excessive amounts of liquid, as doing so can damage the product or result in injury.

How to Store RIVER MAX?

  1. Store RIVER MAX in a dry and cool environment, away from any abrasive objects. Never store RIVER MAX in environments below -4°F (-20°C) or above 140°F (60°C). DO NOT store or place RIVER MAX near water;
  2. If RIVER MAX is not used for a long period of time, the battery life may be impacted. Discharging RIVER MAX to 30%, then charging to 85% every 3 months can help prolong the battery life;
  3. After being fully charged, RIVER MAX has a shelf life of over a year under room temperature and humidity provided that the power station isn’t used to charge or discharge during storage.How to Use RIVER MAX Safely?Please use RIVER MAX in its recommended operating temperature range. Using RIVER MAX out of the optimal operating temperature range may cause the power station to exceed safety limits. Incorrect product usage and failure to adhere to operating recommendations will void the product warranty.If RIVER MAX is used to power electrical devices with heating elements for over 30 minutes, such as a hairdryer, the power station will enter a temperature protection mode. In this case, please wait for around an hour before charging, powering devices, or using the power station again.

How to Upgrade RIVER MAX Firmware?

RIVER MAX firmware can be upgraded using the EcoFlow app. It is recommended that RIVER MAX is plugged into an AC power source, or it has 50% power and the system power is ON when upgrading. For more details, please refer to the “How to upgrade firmware” FAQ in the EcoFlow app.

What’s in the Box

report this ad

References

[xyz-ips snippet=”download-snippet”]


Posted

in

by