Dear UsersThank you for purchasing the new infrared thermometer. In order to use this product safely and correctly, please read this manual thoroughly, especially the Precautions part.After reading this manual, it is recommended to keep the manual at an easily accessible place, preferably close to the device, for future reference.
Limited Warranty and Liability
Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date. This warranty does not apply to damage caused by accident, negligence, misuse, modification, contamination, or improper handling. The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly.Uni-Trend will not be responsible for any special, indirect, incidental, or subsequent damage or loss caused by using this device.
Introduction
The UT305R infrared thermometer (hereinafter referred to as the thermometer) can quickly and accurately determine the surface temperature by measuring the infrared energy radiated from the target surface. It is suitable for non-contact temperature measurement.
Precautions
To ensure proper use of the thermometer, please read this manual carefully before use.
To ensure safety and accuracy of the thermometer, it should only be repaired by a qualified professional using original replacement parts.
If the battery symbol on the LCD flashes, please replace the battery immediately to prevent inaccurate measurement.
Inspect the case before using the thermometer. Do not use the thermometer if it appears damaged. Look for cracks or missing plastic.
Avoid keeping the thermometer near high-temperature environments for long periods.
To ensure measurement accuracy, please use the thermometer in the operating environment [15°C~30°C, <85% RH (non-condensing)].
Please use the thermometer indoors.
The ambient temperature of the measured object must be stable, and it should not be measured in places with large airflow such as fans and air outlets.
When changing to a new environment, please leave the thermometer for 30 minutes before use.
When the measured object comes from a place with a large temperature dif ference from the measurement environment, keep it in the measurement environment for 10 to 30 minutes before measuring.
Do not use the thermometer in places with strong sunlight or electromagnetic interference.
After measuring extremely high or low-temperature objects, please leave the thermometer for 10 minutes before next use.
It is recommended to measure three times at a time, whichever is the most displayed set of data.
Make the sensor window directly face the measured object during measurement, otherwise it will cause the measured temperature to be different from the actual temperature.
Specifications
Model
UT305R
Measuring range
32°C~42.9°C (89.6°F~109.2°F)
LCD size
30mm*30mm
LCD display
TN LCD
Accuracy
±0.3°C (±0.6°F)
Optimal measuring distance
5cm~10cm
Repeatability
0.3°C (0.6°F)
Response time
≤250ms (95% of reading)
Spectral response
8μm~14μm
Auto power off
15s
Low battery indication
High temperature LED alarm
>37.2°C: orange light alarm (≤37.2°C: green light)
High-temperature audible alarm
>37.2°C: audible alarm
Data hold
Unit conversion (°C/°F)
Operating environment
15°C~30°C (59°F~86°F), <85% RH
Transportation/Storage environment
-20°C~60°C (-4°F~140°F), <85% RH
Battery type
9V battery (6F22)
Battery life
Continuous temperature measurement: ≥9 hours forthe alkaline battery; ≥4 hours for the carbon battery
Accessories
Battery, user manual
Product Features
Bright, easy-to-read, and high-contrast displayWith two-color (orange and green) LED and buzzer alarm functionsWith tripod mounting hole (¼ inch)
External Structure
1
Infrared sensor window
2
Trigger
3
Battery cover
4
Tripod mounting hole
5
LCD display
6
Buttons
LCD Description
Buzzer indicator
HI OK LO
Temperature measurement alarm indicator
Low battery indicator
SCAN
Temperature measurement indicator
HOLD
Temperature hold indicator
C F
Temperature unit indicator
8888
Display of the measured temperature
Operating Instructions
Power OnIn the off state, short press the trigger to turn on the thermometer.Power OffIn the HOLD mode, if there is no operation for 15s, the thermometer will automatically power off.Manual Measurement
Pull and hold the trigger after aiming at the measured object. The SCAN icon will be flashing indicating that the target temperature is being measured. The measurement result will be updated on the LCD.
Release the trigger, the SCAN icon disappears, and the HOLD icon appears, indicating that the measurement has been stopped and the last measured value is held.
When the measured temperature exceeds 37.2°C, the HI icon is displayed and the orange light gives an alarm.
Temperature Unit SettingIn the HOLD interface, short press the SET button to enter the temperature unit setting interface, and switch between °C and °F by pressing the button or button.
Audible Alarm SettingIn the HOLD interface, short press the SET button twice to enter the audible alarm setting interface, and turn on/off the audible alarm by pressing the button or button.
Maintenance
General MaintenanceAs the thermometer is reusable apparatus, please pay attention to cleaning and maintenance before use. If it is not in use for a long time, please keep its lens clean and dust-free.1. Clean the case: Wipe dirt with a clean soft cloth or cotton swab dipped in medical alcohol or water.2. Clean the lens: Use clean compressed air to blow off loose particles. Carefully wipe the surface with a cotton swab dipped in medical alcohol or water.
Battery Replacement
If the thermometer is not in use for a long time, please remove the battery to prevent battery leakage. Dispose of used batteries properly in accordance with local regulations.
To replace the battery:1. Open the battery cover.2. Replace with a 9V battery (6F22), noting the polarity.3. Close the battery cover.
Troubleshooting
Symptom
Cause
Action
HI appears
Measured value is greaterthan the maximum range
Stop measuring
LO appears
Measured value is lessthan the minimum range
Stop measuring
Err appears at booting
Exceeding the minimum ormaximum operating temperature
Place the thermometer in a0°C~50°C (32°F~122°F)environment for 30 minutes
Battery symbol flashes
Low battery
Replace the battery