GARDENA 9000CLEAR Submarine Pump Owner’s Manual

GARDENA 9000CLEAR Submarine Pump Owner’s Manual

This product may be used under supervision, or if instruction regarding the safe use of the product has been provided and the resulting dangers have been understood, by children aged 8 and above, as well as by persons with physical, sensory or mental disabilities or a lack of experience and knowledge. Children must not be allowed to play with the product. Cleaning and user maintenance must not be performed by children without supervision. The use of this product by young people under the age of 16 is not recommended.

Intended use: 

The GARDENA Submersible Pump is intended for drainage purposes if flooding occurs but also for transferring water to and from tanks and pumping them out, for drawing water from wells and shafts, for draining boats and yachts and for aerating and circulating water for limited periods and for pumping water containing chlorine and detergents in private domestic gardens and allotments.

Liquids to be pumped: 

The GARDENA Submersible Pump must only be used to pump water.

The pump is fully submersible (water-tight encapsulation) and is submerged in water (for max. submersion depth see 7. TECHNICAL DATA).

The product is suitable for pumping the following liquids:

  • Clear Water Submersible Pump: clean to slightly dirty water with a max. particle size of 5 mm.
  • Dirty Water Submersible Pump: dirty water with a max. particle size of:
    Dirty Water Submersible Pump Max. particle size
    9000DIRT 25 mm
    16000DIRT 35 mm
    25000DIRT 38 mm

The product is not intended for long term use (continuous circulation operation).

DANGER! Risk of injury!The pump should not be used for the delivery of salt water, corrosive, easily inflammable or explosive liquids (e.g. petrol, paraffin, thinners), oil, heating oil or foodstuffs.

SAFETY

IMPORTANT! Read the operator’s manual carefully before use and keep for future reference.

Symbols on the product: 

Read operator’s manual.

General safety warnings

Electrical safety 

DANGER! Electric shock! Risk of injury due to electric shock.

  • The product must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA.
  • Contact GARDENA Service if the Residual Current Device (RCD) has triggered.

DANGER! Risk of physical injury! Risk of injury due to electric current.

  • Disconnect the product from the mains before you maintain or replace parts. Thereby the disconnected socket must be in the visual range.

Safe operating practices 

The water temperature should not exceed 35 °C. The pump must not be used when people are in the water.

Pollution of the liquid could occur due to leakage of lubricants.

Keep bystanders away from the water. Operate the pump only with the elbow connector.

The hose end should be lower than the maximum delivery head.

Circuit breakers 

Thermal protection switch: 

In the event of an overload, the pump is switched off by the built-in thermal motor protection. After sufficient cooling of the motor, the pump is operational again.

Automatic venting: 

This pump is equipped with a vent valve which eliminates any air pockets in the pump. Depending on the function, a small amount of water can escape from the side of the housing.

Additional safety warnings

Electrical safety 

DANGER! Cardiac arrest!This product makes an electromagnetic field while it operates. This field may under some conditions interfere with active or passive medical implants. To decrease the risk of conditions that can possibly injure or kill, we recommend persons with medical implants to speak with their physician and the medical implant manufacturer before you operate the product.

CablesIf extension cables are used, these must comply with the minimum cross-sections in the table below:

Voltage Cable length Cross section
230 – 240 V/50 Hz Up to 20 m 1.5 mm2
230 – 240 V/50 Hz 20 – 50 m 2.5 mm2

DANGER! Electric shock!With a cut off mains plug, moisture can get into electrical parts via the mains cable and cause a short circuit.

  • Never cut the mains plug off (e.g. to feed through wall).
  • Don’t use the power cable for plugging off.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

Mains plug and extension connections must be protected from water splashes.

Ensure that the electrical connections for plugs and sockets are made in areas safe from flooding.

Protect the mains plug and the mains power cable from heat, oil and sharp edges.

Observe the mains voltage. The information on the nameplate must be in agreement with the data for the mains power grid.

The pump’s mains plug must be disconnected before anybody enters the swimming pool or touching the surface of the water.

The mains power cable must not be used for fastening or transporting the pump.

For submerging or lifting/ securing the pump, please use a fastening rope

Please regularly check the connecting line.

Before using, always subject the pump (especially the power cables and the power connections) to a visual inspection.

A pump which is damaged should not be used. In the event of damage, have the pump checked by GARDENA Service.

Assembly instructions: Retighten all screws by hand.

Before use after maintenance, make sure that all parts are screwed together.

When using our pumps with a generator, the warnings of the generator manufacturer must be observed.

Personal safety

DANGER! Risk of suffocation!Small parts can be easily swallowed. There is also a risk that the polybag can suffocate toddlers. Keep toddlers away when you assemble the product

Observe the minimum water level in accordance with the characteristics given for the pump.

Allow the pump to run no longer than 10 minutes against a closed pressure side.

Sand and other abrasive substances cause increased wear and reduce the pump’s output. The float switch may only be operated outside the water. The hose must not be disconnected during operation. Allow the pump to cool down before troubleshooting.

ASSEMBLY

DANGER! Risk of injury! Injury when the product starts accidentally.

Disconnect the product from the mains before you assemble the product.

Connection possibilities of the connection nipple [Fig. A1]:

The hose can be connected via the connection nipple (4) with different hose diameters or the GARDENA Connection System.

  • Large hose diameter: Detach nipple at (a) [ Fig. A2 ]
  • GARDENA Connection System/ Art. 9046: Medium hose diameter:  Detach nipple at (b) [ Fig. A3 ]
  • Small hose diameter: Do not detach nipple [ Fig. A4 ]

When using the largest hose diameter, the pump has the maximum delivery capacity.

Pump Art. 9030 Art. 9042 Art. 9046
Art. 9032    
Art. 9040
Small hose diameter 25 mm (1″) 25 mm (1″) 32 mm (1 1/4″)
Art. GARDENA Hose Clamp Art. 7193 Art. 7193 Art. 7194
Medium hose diamete GARDENA Connection System G 1″ GARDENA Connection System G 1″ 38 mm (1 1/2″)
Art. GARDENA Hose Clamp   32 mm (1 1/4″)* Art. 7194 Art. 7195
Large hose diameter 38 mm (1 1/2″) 38 mm (1 1/2″) 51 mm (2″)
Art. GARDENA Hose Clamp Art. 7195 Art. 7195 Art. 7196

When using the 38 mm (1 1/2″) hose, we recommend the GARDENA Flat Hose Set Art. 5005 with 10 m hose and hose clamp

For Art. 9042 an additional connection nipple ß4a for 1 1/4″ hoses is supplied.

To connect the hose via the connection nipple: 

  1. When using the large diameter hose, cut off the connection nipple (4) at (a).
  2. Only for Art. 9046: When using the medium hose diameter, cut off the connection nipple (4) at (b).
  3. Push the hose onto the connection nipple (4).
  4. Fix the hose to the connection nipple (4) e.g. with a GARDENA Hose Clamp

Connect hose via the GARDENA Connection System: 

With 25000DIRT (Art. 9046) the hose cannot be connected via the connection nipple (4) with the GARDENA Connection System. 19 mm (3/4″)/15 mm (5/8″) and 13 mm (1/2″) hoses can be connected via the GARDENA Connection System. We do not recommend hose diameters smaller than 25 mm (1″), otherwise there will be a significant reduction in the output of the delivery rate.

Hose diameter Pump connection
13 mm (1/2″) GARDENA Pump Connection Set Art. 1750
15 mm (5/8″) GARDENA Pump Connection Set Art. 1750
19 mm (3/4″) GARDENA Pump Connection Set Art. 1752

Cut off the connection nipple (4) at (

Connect the hose to the connection nipple (4) via the appropriate GARDENA Connection System.

To assemble the pump connection [Fig. A5]: 

DANGER! Risk of injury! Cut injury by the impeller.

Operate the pump only with the elbow connector.

The hose can be easily connected and disconnected using the locking devices (2) on the elbow connector (1).

  1. Screw the elbow connector (1) clockwise into the pump until it stops. (If the hose is to be installed horizontally, the elbow connector (1) can be screwed out again up to half a turn.)
  2. Only for Art. 9042/9046: Screw the connection piece (3) into the connection nipple (4).
  3. Push the connection nipple (4) of the hose into the elbow connector (1) until it stops and it engages audibly and visibly. The hose is securely connected to the pump

OPERATION

DANGER! Risk of injury! Injury when the product starts accidentally.

Disconnect the product from the mains before you connect, adjust or transport the product.

To pump water:If the pump cannot be immersed via the handle, the pump must always be immersed via a rope. Attach the rope by pulling it through the eyelets provided and knotting it. Minimum immersion depth during initial operation see 7. TECHNICAL DATA.

Take care that the pump is located where the inlet openings at the suction base are not obstructed neither completely nor partly

Stand the pump on a brick if using in a pond.

If the suction process is close to the minimum water level at start-up, the suction process may take longer.

  1. Immerse the pump.
  2. Connect the pump to the mains. Attention! The pump can start immediately depending on the float switch setting

Automatic mode with float switch [Fig. O1]:

By adjusting the float switch (5) you have the possibility to determine the switching heights. For safe operation, the float switch must be able to move freely around the pump.

To adjust the Cut-in and Cut-out Height [Fig. O1]: 

The maximum cut-in height and minimum cut-out height (see 7. TECHNICAL DATA) can be adjusted by pushing the float switch wire into the float switch lock.

  • The higher the cable is clamped, the higher the cut-in and cut-out height.
  • The shorter the length of cable between the float switch (5) and the float switch lock (A), the lower the cut-in height and the higher the cut-out height.

Push the cable of the float switch (11) into one of the openings of the float switch lock (A).

Check that the pump switches off automatically

CAUTION!

In order to ensure that the float switch is able to switch on and off, the cable length between the float switch and the float switch lock must be at least 10 cm.

Manual operation [Fig. O2]: 

The pump remains permanently in operation because the float switch is bypassed.

  1. Slide the float switch (5) with the cable downwards onto the float switch locking device (A).
  2. Place the pump on a firm surface.
  3. Connect the pump to the mains.Attention! The pump begins operating immediately

The pump runs permanently without dry-running protection due to the bypassed float switch. To avoid damage due to dry running, only operate under supervision.

The minimum residual water depth (see 7. TECHNICAL DATA) is only achieved in manual mode because the float switch already switches off the pump before this when in automatic mode.

MAINTENANCE

DANGER! Risk of injury! Injury when the product starts accidentally.

Disconnect the product from the mains before you maintain the product.

To clean the pump:

DANGER! Risk of injury! Risk of injury and risk of damage to the product.

  • Do not clean the product with a water jet (in particular high-pressure water jet).
  • Do not clean with chemicals including petrol or solvents. Some can destroy critical plastic parts.
  • Clean the surface of the pump with a damp cloth.

To flush the pump: 

After pumping water containing chlorine, detergents or heavily soiled water, the pump must be flushed.

  1. Pump lukewarm water (max. 35 °C), possibly adding a mild cleaning agent (e.g. detergent) until the pumped water runs clear.
  2. Remove residuals according to the waste disposal laws applicable in your area.

STORAGE

To put into storage:

The pump is not frost-proof! 

The product must be stored away from children.

  1. Disconnect the pump from the mains.
  2. Turn the pump upside down until no more water runs out.
  3. Clean the pump (see 4. MAINTENANCE).
  4. Store the pump in a dry, enclosed and frost-free place

Disposal

(in accordance with RL2012/19/EC)

The product must not be disposed of to normal household waste. It must be disposed of in line with local environmental regulations.

IMPORTANT! 

Dispose of the product through or via your municipal recycling collection centre.

TROUBLESHOOTING

DANGER! Risk of injury!Injury when the product starts accidentally. Disconnect the product from the mains before you troubleshoot the product.

To clean the suction base and the impeller [Fig. T1]: 

  1. Only for Art. 9046: Unscrew the 5 Phillips screws (9) and remove the cover (10).
  2. Unscrew the 4 Phillips screws (6).
  3. Pull the suction base (7) off the pump.
  4. Clean suction base (7) and impeller (8) (the warranty does not become void as a result of this maintenance work).
  5. Clean the sealing surfaces carefully to avoid damage and leakage.
  6. Reassemble the suction base (7) in reverse order

A damaged seal must be replaced. 

For safety reasons a damaged impeller can only be exchanged by the GARDENA Service Centre.

Problem Possible Cause Remedy
Pump is running, but doesn’t deliver water Air cannot escape, because the pressure line is closed. (Possible kink in the pressure hose.)  Open the pressure line (e.g. shut-off valve, delivery units).
Air in suction foot. Wait for about 60 seconds until the pump has vented; if necessary, turn off and then on again.
Suction opening is clogged. Clean the suction opening with a water jet.
Hose is clogged. Remove the clog from the hose
Impeller is blocked. Clean the impeller.
Water level below minimum water level when put into operation Submerge the pump deeper.
Pump does not start or stops suddenly during operation Thermal switch has turned the pump off because of overheating Clean the suction opening. Observe the max. media temperature (35 °C).
Pumping without electricity Check fuses and electrical plug connections
Check fuses and electrical plug connections Disconnect the pump and contact the GARDENA Service
Pump is running but the delivery drops suddenly Suction opening is clogged. Clean the suction opening with a water jet
Hose is clogged. Remove the clog from the hose.

NOTE: For any other malfunctions please contact the GARDENA service department. Repairs must only be done by GARDENA service departments or specialist dealers approved by GARDENA.

TECHNICAL DATA

Submersible Pump Unit Value

(Art. 9030)

Value

(Art. 9032)

Value

(Art. 9040)

Value

(Art. 9042)

Value

(Art. 9046)

Rated power W 300 450 300 450 1100
Mains voltage V (AC) 230 230 230 230 230
Mains frequency Hz 50 50 50 50 50
Max. delivery capacity I/h 9000 11000 9000 16000 25000
Max. pressure/ bar/ 0.6/ 0.7/ 0.6/ 0.7/ 1.1/
Max. delivery head m 6.0 7.0 6.0 7.0 11.0
Max. submersion depth m 7 7 7 7 7
Min./max. cut-in height mm 250 / 390

 

230 / 400 230 / 400 260 / 420 300 / 600
Min./max. cut-out height mm 45 / 90 50 / 90 50 / 90 50 / 90 120 / 200
Residual water level mm 2 2 25 35 38
Dirty water with max. particle diameter mm 5 5 25 35 38
Minimum water depth for operation (approx.) mm 10 10 30 45 45
Power cable m 10 (H05RN-F) 10 (H05RN-F) 10 (H05RN-F) 10 (H05RN-F) 10 (H07RN-F)
Weight without cable (approx.) kg 4.1

 

 

4.6 4.2

 

 

4.7 7.1
Connection thread water outlet Inch G 1 1/4″ G 1 1/4″ G 1 1/2″ G 1 1/2″ G 1 1/2″
Connection options Inch 1″ / 1 1/2″ / G 1″ 1″ / 1 1/2″ / G 1 1″ / 1 1/2″ / G 1″ 1″ / 1 1/4″ / 1 1/2″ / G 1″ 1 1/4″ / 1 1/2″ / 2″
Max. media temperature °C 35 35 35 35 35

Note: The switch on/ switch-off heights and the minimum water level on start up were calculated without the height differences to be negotiated. Pump heads of approx. 1 m or more may result in longer suction times of up to 1 minute, or higher minimum water levels of up to +5 cm.

ACCESSORIES

GARDENA Flat Hose Set 10 m 38 mm (1/2″) hose with hose clamp. Art. 5005
GARDENA Hose Clamp For 25 mm (1″) hoses via the connection nipple. Art. 7193
GARDENA Hose Clamp For 32 mm (1 1/4″) hoses via the connection nipple. Art. 7194
GARDENA Hose Clamp For 38 mm (1 1/2″) hoses via the connection nipple. Art. 7195
GARDENA Hose Clamp For 51 mm (2″) hoses via the connection nipple. Art. 7196
GARDENA Pump Connection Set For 19 mm (3/4″) hoses via the GARDENA Connection System. Art. 1752

SERVICE/WARRANTY

Service

Please contact the address on the back page.

Warranty statement:In the event of a warranty claim, no charge is levied to you for the services provided.

GARDENA Manufacturing GmbH grants a warranty for all original GARDENA new products for two years from the date of original purchase from the retailer, provided that the devices have been for private use only. This manufacturer’s warranty does not apply to products acquired second hand. This warranty includes all significant defects of the product that can be proved to be material or manufacturing faults. This warranty is fulfilled by supplying a fully functional replacement product or by repairing the faulty product sent to us free of charge; we reserve the right to choose between these options. This service is subject to the following provisions:

  • The product has been used for its intended purpose as per the recommendations in the operating instructions.
  • Neither the purchaser nor a third party has attempted to open or repair the product.
  • Only Original GARDENA replacement parts and wear parts have been used for operation.
  • Presentation of the receipt.

Normal wear and tear of parts and components (such as blades, blade fixing parts, turbines, light bulbs, V-belts / toothed belts, impellers, air filters, spark plugs), visual changes, wear parts and consumables are excluded from the warranty.

This manufacturer’s warranty is limited to replacement and repair of products in accordance with the abovementioned conditions. The manufacturer’s warranty does not constitute an entitlement to lodge other claims against us as a manufacturer, such as for damages. This manufacturer’s warranty does not, of course, affect statutory and contractual warranty claims against the dealer/retailer. The manufacturer’s warranty is governed by the law of the Federal Republic of Germany.

In case of a warranty claim, please return the faulty product, together with a copy of the receipt and a description of the fault, with postage paid to the service address.

Consumables: 

The impeller is a consumable and is not included in the warranty

Product liability

report this ad

In accordance with the German Product Liability Act, we hereby expressly declare that we accept no liability for damage incurred from our products where said products have not been properly repaired by a GARDENA-approved service partner or where original GARDENA parts or parts authorised by GARDENA were not used.

 

References