Event Lighting reserves the right to revise the manual at any time. Information and specifications within this manual are subject to change without notice. Event Lighting assumes no liability or responsibility for any errors or omissions. Please consult Event Lighting for any clarification or information regarding this item.Version 1.1 – 23/10/2019 (revised 05/11/2020)

Safety Instructions

Warning

  • Do not open this device, there are no user-serviceable parts inside. Risk of electric shock.
  • Do not look directly at the light source from close range.
  • Avoid contact with the unit during operation, as the housing may become hot. Allow the fixture to cool for at least 15 minutes after turning off before touching.
  • Install this device in a location with adequate ventilation, at least 50cm from adjacent surfaces.
  • Do not operate this device, or connect this device to power, within 50cm of any flammable material.
  • Use a safety chain when mounting this device overhead.
  • Do not operate this device outdoors where excessive dust, heat, water, or humidity may affect it.
  • Do not operate this device if the housing, lenses, or cables appear damaged.
  • Do not connect this device to a dimmer or rheostat.
  • Do not operate this device at temperatures higher than 40°C (104°F).
  • Only connect this device to a grounded and protected circuit.
  • Only use the hanging bracket to carry this device.
  • Stop using this device immediately if a serious operating problem becomes apparent.

Fuse Replacement

If the fine-wire fuse of the device fuses, replace the fuse with one of the same types of ratings.Before replacing the fuse, unplug the device from the power source.Fuse Replacement Steps

  1. Unscrew the fuse holder located on the rear panel from the housing.
  2. Remove the old fuse from the holder.
  3. Install the new fuse into the holder.
  4. Place the fuse holder back into the housing and secure it tightly.

Product Installation

PAR12X8L can be mounted in many orientations, provided each individual device is secured by the use of the correct mounting bracket. Use a safety chain when mounting  PAR9X15O overhead.

Dimensions

Lux Chart

Lux chart @ 40° ( PAR12X9L)

1m

2m 3m 4m

5m

00.73

01.46 02.18 02.91 03.64
R 3,300 850 370 230

140

G

3,700 1,055 480 290 180
B 5,500 1,626 705 415

260

W

4,200 1,256 570 335 222
FULL 13,800 4,950 1,960 850

700

Control Board Operation

Menu Map

Static Colour Mode

Value  Function 
C1 Red
C2 Green
C3 Blue
C4 White
C5 Red+White
C6 Green+White
C7 Blue+White
C8 Green+Blue
C9 Red+Blue
C10 Red+Green
C11 Red+Green+Blue
C12 Green+Blue+White
C13 Red+Blue+White
C14 Red+Green+White
C15 Red+Green+Blue+White

DMX Chart

4 Channel Mode

Channel  Value  Function 
1 000-255 Red: 0% ~ 100%
2 000-255 Green: 0% ~ 100%
3 000-255 Blue: 0% ~ 100%
4 000-255 White: 0% ~ 100%

9 Channel Mode

Channel

Value Function

Note

1 000-255 Master DIMMER 0% ~ 100%
2 000-255 Red: 0% ~ 100%
3 000-255 Green: 0% ~ 100%
4 000-255 Blue: 0% ~ 100%
5 000-255 White: 0% ~ 100%
6 000-012 Strobe OFF
013-255 Strobe (slow-fast)
 

 

 

 

 

 

 

 

 

 

7

000-009 No Function
010-019 Program 1
020-029 Program 2
030-039 Program 3
040-049 Program 4
050-059 Program 5
060-069 Program 6
070-079 Program 7
080-089 Program 8
090-099 Program 9
100-109 Program 10
110-119 Program 11
120-129 Program 12
130-139 Program 13
140-255 Sound active mode
8 000-255 Speed of auto programs (slow ~ fast) Ch7 must be set between 10-139
9 000-255 Colour fade time (jump ~ fade) The mode must be set to “nod0”

IR Remote

In order to use the IR Remote, PAR12X8L must be in DMX mode without an active DMX connection. If a DMX signal is received, PAR12X8L will prioritize the DMX signal and ignore the IR Remote.

Use On/Off to turn PAR12X8L on or off. The current IR settings will be saved automatically when PAR12X8L is powered off and reloaded when it is turned on again. To reset to the factory default Blackout mode, long press Off.

Press R/G/B/W to light up the LEDs in red, green, blue, white, amber, or UV respectively. There is also a selection of pre-set colors underneath the R/G/B/W buttons,  known as the D Area. Press a button in the D Area to select that color.Press X to increase the intensity of the selected color and Y to decrease the intensity of the selected color.Press Auto/Sound/Strobe to switch on or off Auto mode, Sound Active Mode, and Strobe mode, respectively.Press Blackout to clear all the remote settings and blackout PAR12X8L.

Technical Specifications

Photometric

  • Light Source: 12x 8W RGBW 4-in-1 LEDs
  • Beam Angle: 40°
  • PWM: 20,000Hz
  • LED Lifespan: 50,000hours

Effects

  • Dimming: 0~100%
  • Strobe: 1 – 20 Hz

Power

  • Input Voltage: 100~240V AC, 50/60Hz
  • Power Consumption: 60W
  • Connection: IEC in/out

Control

  • Operation Modes: DMX, manual, auto, sound active, IR remote, master/slave
  • DMX channels: 4/9

Housing

  • Cooling: Fanless Cooling
  • Net weight: 1.85kg

Warranty

Please refer to your local dealer or contact Event Lighting.