Uni-Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase date. This warranty does not apply to damage caused by accident, negligence, misuse, modification, contamination or improper handling. The dealer shall not be entitled to give any other warranty on behalf of Uni-Trend. If you need warranty service within the warranty period, please contact your seller directly.

Uni-Trend will not be responsible for any special, indirect, incidental or subsequent damage or loss caused by using this device.

Safety Instructions

To ensure proper use of this product, please read the instructions carefully before using.
  • To ensure measurement accuracy, please use the product in an operating environment of 0°C~50°C, <85% RH (non-condensing).
  • When changing to a new environment, please turn on the product and leave it for 10 to 15 minutes before measuring.
  • The ambient temperature for measuring must be stable. Do not measure in places with large airflow such as fans and air outlets.
  • When the measured object comes from a place with a large temperature difference from the measurement environment, keep it in the measurement environment for 10 to 30 minutes before measuring.
  • The product tests the surface temperature of the object. If temperature compensation is needed, please adjust in the Settings menu.
  • The product has a self-calibration function. If the reading jumps quickly, please read the temperature after it gets steady.
  • After measuring extremely high or low temperature objects, please leave the product for 10 minutes before next use.
  • Do not use the product in places with strong sunlight or electromagnetic interference.
  • Please do not use this product in flammable, explosive, steamy, wet or corrosive environments.
  • Please stop using the product if it is damaged or modified to avoid inaccurate measurement results.
  • Please use the correct emissivity to obtain accurate temperature readouts. To ensure accuracy of the product, please warm it up for 10 minutes before measuring if it has not been used for a long time.
  • When being charged, the internal temperature of the product rises, which will lead to inaccurate temperature measurement. So, it is not recommended to take measurements during or right after charging the product.
  • The inherent temperature drift of the sensor will occasionally cause inaccurate measurement. In this case, press the down button under the temperature measurement interface to bring out “Calibrating” and automatically calibrate the temperature.

Structure

Item

Description Item

Description

1

Micro SD card slot

10

Tripod mounting hole

2

Type-C USB interface

11

Flashlight button

3

Interface cover

12

Left button

4

LED light

13

Down button

5

Infrared camera lens cover

14

Right button

6

Trigger

15

Back button

7

Infrared camera lens

16

Replay button

8

LCD

17

Up button

9

Power button

18

SET button

Display

  • Display size: 2.8″
  • Display resolution: 320 (vertical) x 240 (horizontal) pixels

Item

Description Item

Description

1

Temperature unit option

8

Maximum temperature point

2

Cursor option

9

Center point

3

Color palette option

10

Center point temperature

4

High/Low temperature alarm option

11

Maximum temperature

5

Settings option

12

Date & time

6

Temperature bar lower value

13

Battery status

7

Temperature bar upper value

14

ROI

Power On/Off

Press the power button for 3s to power on, and press the power button for 1s to power off.

Menu Introduction

Operating Instructions

Temperature Unit Selection

  1. Press the SET button to open the main menu.
  2. Press the left/right button to select the option.
  3. Press the SET button to enter the temperature unit.
  4. Press the up/down button to select °C or °F.
  5. Press the back button to exit the current menu.
Center Point, High Temperature Tracking and ROI

To track center point temperature:
  1. Press the SET button to open the main menu.
  2. Press the left/right button to select the option.
  3. Press the SET button to enter the cursor.
  4. Press the up/down button to select the desired option.
  5. Press the SET button to confirm.
  6. Press the back button to exit the current menu.
Color Palette Selection

  1. Press the SET button to open the main menu.
  2. Press the left/right button to select the option.
  3. Press the SET button to enter the color palette.
  4. Press the up/down button to select the desired color from Iron Red, Rainbow, White Hot, Red Hot, and Ice Blue.
  5. Press the back button to exit the current menu.
High/Low Temperature Alarm

To enable high/low temperature alarm:
  1. Press the SET button to open the main menu.
  2. Press the left/right button to select the option.
  3. Press the SET button to enter the high/low temperature alarm.
  4. Press the up/down button to select HI (High) or LO (Low).
  5. Press the SET button to confirm.
  6. Press the back button to exit the current menu.

Note: High temperature alarm and low temperature alarm can be enabled simultaneously or separately.

Settings

To enter Settings menu:
  1. Press the SET button to open the main menu.
  2. Press the left/right button to select the option.
  3. Press the SET button to confirm.

Language

To Set Language:

  1. Press the up/down button to select the Language option in the Settings menu.
  2. Press the SET button to enter the Language submenu.
  3. Press the up/down button to select the desired language.
  4. Press the SET button to confirm.
  5. Press the back button to exit the current menu.

Date & Time

To Set Date & Time:

  1. Press the up/down button to select the Date & Time option in the settings menu.
  2. Press the SET button to enter the Date & Time sub menu.
  3. Press the left/right button to select the parameter to be adjusted.
  4. Press the SET button to enter the parameter adjustment state.
  5. Press the up/down button to increase or decrease the value.
  6. Press the SET button to save the settings and return to set other parameters.
  7. Press the back button to exit the current menu.

Emissivity/Temperature Compensation

To set emissivity/temperature compensation:
  1. Press the up/down button to select the Emissivity option in the Settings menu.
  2. Press the SET button to enter the Emissivity submenu.
  3. Press the up/down button to select emissivity or temperature compensation.
  4. Press the SET button to enter the parameter adjustment state.
  5. Press the up/down button to increase or decrease the value.
  6. Press the SET button to save the settings.
  7. Press the back button to exit the current menu.

Note: For emissivity values of common materials, please refer to the Common Emissivity.

Auto Power Off

To set auto power off:
  1. Press the up/down button to select the Auto Power Off option in the settings menu.
  2. Press the SET button to enter the Auto Power Off submenu.
  3. Press the up/down button to select the desired option from 5 Min, 10 Min, 30 Min, and Off.
  4. Press the SET button to confirm.
  5. Press the back button to exit the current menu.

Display Brightness

To set display brightness:
  1. Press the up/down button to select the Brightness option in the settings menu.
  2. Press the SET button to enter the Brightness submenu.
  3. Press the up/down button to select the desired option from Low, Middle, and High.
  4. Press the SET button to confirm.
  5. Press the back button to exit the current menu.

Temperature Bar

To turn on/off temperature bar:
  1. Press the up/down button to select the Temp Bar option in the settings menu.
  2. Press the SET button to enter the Temp Bar submenu.
  3. Press the up/down button to select On or Off.
  4. Press the SET button to confirm.
  5. Press the back button to exit the current menu.

Alarm Temperatures

To set alarm temperatures:
  1. Press the up/down button to select the HI/LO Alert option in the settings menu.
  2. Press the SET button to enter the HI/LO Alert submenu.
  3. Press the up/down button to select the desired option from HI Alert and LO Alert.
  4. Press the SET button to enter the temperature adjustment state.
  5. Press the up/down button to adjust the temperature.
  6. Press the SET button to save the settings and return to set another temperature.
  7. Press the back button to exit the current menu.

Device Information

To view the device information:
  1. Press the up/down button to select the Device Info option in the settings menu.
  2. Press the SET button to view the detail information of the device.
  3. Press the back button to exit the current menu.

Factory Reset

To restore settings:
  1. Press the up/down button to select the Factory Reset option in the settings mneu.
  2. Press the SET button to enter the Factory Reset submenu.
  3. Press the up/down button to select Yes.
  4. Press the SET button to confirm.
  5. Press the back button to exit the current menu.

Format SD Card

To format SD card:
  1. Press the up/down button to select the Format SD option in the settings menu.
  2. Press the SET button to enter the Format SD submenu.
  3. Press the up/down button to select Yes.
  4. Press the SET button to confirm.
  5. Press the back button to exit the current menu.

Auto Save

To turn on/off auto save:
  1. Press the up/down button to select the Auto Save option in the settings menu.
  2. Press the SET button to enter the Auto Save submenu.
  3. Press the up/down button to select On or Off.
  4. Press the SET button to confirm.
  5. Press the back button to exit the current menu.

Note: Do not remove or insert the SD card in saving or viewing pictures. If the SD card is replaced during use, restart the device after the replacement to take and save pictures.

USB Mode

  1. Download and install the PC software (refer to UNI-T Documents Download Operation Guide).
  2. Connect the USB cable to the PC.
  3. Set to USB disk mode to browse pictures and analyze data through the PC software.
  4. Set to USB camera mode to realize real-time image transmission through the PC software.

Note: Do not unplug the USB cable while the software is loading pictures.

Specifications

Sensor

UFPA
Temperature range

-10°C~400°C

Measurement resolution

0.1°C
Accuracy

For temperatures ≥0°C,accuracy: ±2°C or ±2%(Whichever is greater)

Response time

≤500ms
IR resolution

4800 pixels (80 × 60)

Pixel size

17μm
Color palette

Iron Red, Rainbow, White Hot, Red Hot, Ice Blue

Infrared spectral band

8μm~14μm
Field of view (FOV)

51° (H) × 38° (V)

Spatial resolution (IFOV)

11mrad
Thermal sensitivity (NETD)

≤150mK

Frame rate

≤9Hz
Image format

BMP

Certifications

-CE (EN 61326-1:2013, EN 61326-2-2:2013, EN 61326-2-3) -RoHS

General Parameters

Audio alarm

Yes
PC software

Yes

Data transmission

Type-C USB interface
Real time image transmission

Yes

Product size (L x W x H)

236mm x 75.5mm x 86mm
Display type

2.8″ TFT LCD

Display resolution

320 × 240 pixels
Battery

3.6V/5000mAh rechargeable Li-ion battery

Auto power off

5 minutes, 10 minutes, 30 minutes, off (default: 30 minutes)
Battery life

≥6 hours

Charging time

4 hours
Charging voltage/current

5V/2A

IP Rating

IP65
Drop test

2m

Image storage

Micro SD card
Transportation/storage environment

-20°C~60°C (-4°F~140°F),<85% RH (non-condensing)

Operating environment

0°C~50°C (32°F~122°F),<85% RH (non-condensing)
Operating altitude

≤2000m

Standard accessories

User manual, USB cable, 16GB Micro SD card

Maintenance

Use a wet cloth or weak soap solution to clean the outer shell of the device. Do not use abrasives, isopropyl alcohol or solvents to clean the outer shell, lens or window.

Common Emissivity

Material

Emissivity Material

Emissivity

Wood

0.85

Black paper

0.86

Water

0.96

Polycarbonate

0.8

Brick

0.75

Concrete

0.97

Stainless steel

0.14

Copper oxide

0.78

Tape

0.96

Cast iron

0.81

Aluminum plate

0.09

Rust

0.8

Copper plate

0.06

Gypsum

0.75

Black aluminum

0.95

Paint

0.9

Human skin

0.98

Rubber

0.95

Asphalt

0.96

Soil

0.93

PVC

0.93

   

Note: This manual can be downloaded from the official website of Uni-Trend (refer to UNI-T Documents Download Operation Guide).