THE BASEMENT WATCHDOG CITE-33 1/3 HP Combination Primary and Backup Sump Pump System Instruction Manual

CITE-33 1/3 HP Combination Primary and Backup Sump Pump System

Combination Primary and Backup Sump Pump System

Instruction Manual & Safety WarningsVoir instructions en français à la page 15

Table of Contents

Important Safety Warnings and

Instructions

Electrical precautions

1

Battery preparation

1

Battery precautions

1

Introduction

Items included in system

2

Additional items needed

2

System specifications

2

Installing the Pipe and Pump 3

Preparing the Battery

4,5

Battery Instructions

4,5

Battery Maintenance

5

System Connections

Mounting the backup control unit 5

Connecting the backup pump

5

Installing the battery fluid sensor 5

Connecting the battery

6

Connecting the charger

6

Connecting the primary pump

6

Product Operation

6

Understanding the Warning

Lights and Alarms

Silencing the alarm during

an emergency

6

Power alarm

7

Water alarm

7

Backup pump alarm

7

Replacing the backup pump

8

Replacing the primary pump

8

System

9

Battery alarm

9

Cleaning battery terminals

10

Replacing the battery

10

Testing the System

Testing the pump

11

Testing the float switch

11

Maintenance Check List

11

Parts & Service Information

Technical support

12

Replacement Parts Diagram & List 12

Troubleshooting Guide

13

Warranty

14

IMPORTANT: Even if you have the Basement Watchdog sump pump system installed by someone else, you must read and follow the safety information contained in this manual. Failure to do so could result in property damage, serious injury, or death.

Important Safety Warnings & InstructionsSAVE THESE INSTRUCTIONS. This manual contains important SAFETY WARNINGS and OPERATING INSTRUCTIONS for the Basement Watchdog combination sump pump system. You will need to refer to it before attempting any installation or maintenance. ALWAYS keep these instructions with the unit so that they will be easily accessible.Failure to read and follow these warnings and instructions could result in property damage, serious injury, or death. It is important to read this manual, even if you did not install the Basement Watchdog combination sump pump, since this manual contains safety information regarding the use and maintenance of this product. DO NOT DISCARD THIS MANUAL.ELECTRICAL PRECAUTIONS! WARNINGThis installation must be in accordance with the National Electric Code and all applicable local codes and ordinances.! DANGERRisk of electrical shock and fire hazard. May result in death serious injury, shock or burns. To help reduce these risks, observe the following precautions:· DO NOT walk on wet areas of the basement until all power has been turned off. If the main power supply is in a wet basement, call an electrician.· ALWAYS disconnect the pump from the power source before servicing or making adjustments.· ALWAYS unplug the control unit and disconnect the cables from the battery before attempting any maintenance or cleaning.· NEVER handle the pump or motor with wet hands or when standing on a wet or damp surface while the pump is plugged into the power source.· MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This pump is wired with a 3-prong grounded plug. To reduce the risk of electric shock, be certain that it is only connected to a properly grounded 3-prong receptacle. If you have a 2prong receptacle, have a licensed electricianPage 1

replace it with a 3-prong receptacle according to local codes and ordinances. · NEVER bypass grounding wires or remove the ground prong from the plug. · DO NOT use an extension cord. The electrical outlet should be within the length of the pump’s power cord, and at least 4 feet above the floor level to minimize potential hazards from flood conditions. · DO NOT use an attachment not recommended or sold by the manufacturer. It may result in a risk of fire or injury from an electrical shock. · DO protect the electrical cord from sharp objects, hot surfaces, oil and chemicals. Avoid kinking the cord. · MAKE SURE the supply circuit has a dedicated fuse or circuit breaker rated to handle the power requirements noted on the nameplate of the pump.

CAUTION

To reduce the risk of hazards that can cause injury or property damage, observe the following precautions:

· DO NOT use the power cord or strain relief to

carry the pumps. Use the handle.

· DO NOT pull on the cord to disconnect the

system or the pump. Pull the plug.

· DO NOT expose the control units to moisture,

water, rain or snow. DO NOT place control

units on the floor.

· DO NOT operate the pumps or control units if

they have been damaged in any way.

· DO NOT use pumps in pits handling raw

sewage, salt water, or hazardous liquids. This

product is rated for ground water use only.

· DO NOT disassemble the pumps or control

units. When service is required, contact

Glentronics’ technical support at 800-991-

0466, option 3. Return the product to the

manufacturer for any repairs at the following

address:

Glentronics, Inc.

645 Heathrow Drive, Lincolnshire, IL 60069

BATTERY PREPARATION! WARNING / POISONSulfuric acid can cause blindness or severe burns. Avoid contact with skin, eyes or clothing. In the event of accident, flush with water and call a physician immediately. KEEP OUT OF REACH OF CHILDREN.

To help reduce these risks, observe the following precautions: · Someone should be within range of your voiceor close enough to come to your aid when you work near a lead-acid battery. · Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing or eyes. · Wear eye and clothing protection and avoid touching your eyes while working with battery acid or working near the battery. · If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, immediately flood eye with running cold water for at least 15 minutes and get medical attention.! WARNING: Battery posts and terminals contain lead, lead compounds or chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. Wash hands after handling. See https://www.p65warnings.ca.gov/ for more information.! WARNING: Battery fluid can expose you to chemicals including strong inorganic acid mists containing sulfuric acid, which is known to the State of California to cause cancer. For more information go to www.P65warnings.ca.gov.BATTERY PRECAUTIONS! DANGERExplosive gases could cause serious injury or death. Cigarettes, flames or sparks could cause battery to explode in enclosed spaces. Charge in well-ventilated area. Always shield eyes and face from battery. Keep vent caps tight and level.To help reduce these risks, observe the following precautions: · NEVER smoke or allow a spark or flame in thevicinity of the battery. · Use the Basement Watchdog control unit forcharging a LEAD-ACID battery only. DO NOT use the control unit for charging dry-cell batteries that are most commonly used with home appliances. · Be sure the area around the battery is wellventilated. · When cleaning or adding water to the battery, first fan the top of the battery with a piece of cardboard or another non-metallic material to

blow away any hydrogen or oxygen gas that may have been emitted from the battery. · DO NOT drop a metal tool onto the battery. It might spark or short-circuit the battery and cause an explosion. · Remove personal metal items such as rings, bracelets, watches, etc. when working with a lead-acid battery. A short circuit through one of these items can melt it causing a severe burn. · ALWAYS remove the charger from the electrical outlet before connecting or disconnecting the battery cables. Never allow the rings to touch each other. · Check the polarity of the battery posts. The POSITIVE (+) battery post usually has a larger diameter than the NEGATIVE (-) post.

POSITIVE POST HAS LARGER DIAMETER

NEGATIVE POST HAS SMALLER DIAMETER

· When connecting the battery cables, first connect the small ring on the end of the WHITE wire to the NEGATIVE (-) post of the battery, and then connect the large ring on end of the BLACK wire to the POSITIVE (+) post of the battery.

POSITIVE POST

NEGATIVE POST

· ALWAYS keep the cover secured on the battery box by slipping the tabs through the fittings on the front and back of the box.

! DANGERDo not use system to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc.

IntroductionThe Basement Watchdog combination sump pump system is designed to provide both primary and backup pumping capabilities. The primary pump will operate as long as it is receiving AC power. If the power is interrupted, or more water is coming into the sump than the AC pump can handle, the backup sump pump will begin pumping automatically. The backup system has unique monitoring features that diagnose a problem and sound an alarm. A light on the display panel of the control unit will indicate the cause of the alarm and the corrective action. The two systems have been preassembled for easy installation.The Basement Watchdog Sump Pump System includes:· A 1/3 HP primary pump with a caged dual float switch, and a blue piggyback controller that plugs into the wall outlet· A backup pump supported by a bracket · A control unit for the backup pump with abattery fluid sensor, a dual float switch, and battery cables · A cable tie to attach the backup control unit to the discharge pipe · Two cable ties to secure the other wires to the discharge pipe · A battery cap with a hole to accommodate the fluid sensor · A battery charger · A rubber unionYou will also need to supply:· A Basement Watchdog Emergency Standby Battery, Basement Watchdog Big Standby Battery or Basement Watchdog Maintenance Free (AGM) Standby Battery.* DO NOT use an automotive battery with this system· Six quarts of 1.265 specific gravity battery acid (if using a wet cell standby battery)· A battery box with a cover*The internal construction of some wet cell batteries may not be compatible with this system. Glentronics can not guarantee the compatibility of other brands of batteries. The use of a Basement Watchdog battery is HIGHLY recommended.

Backup PumpBackup Pump Controller Battery Charger

Backup Pump Float SwitchPrimary Pump Float Switch Primary PumpRubber Union

Battery Cables

Fluid Sensor Battery Cap

Cable Ties

Primary Pump Controller

For some installations you may also need additional items:· 1-1/2″ rigid PVC pipe· A 1-1/2″ PVC pipe connector or a 1-1/2″ rubber union· PVC pipe cleaner and cement

System SpecificationsPower supply requirements . . . 115 volts, 60 Hz AC pump pumping capacity. . . 3100 GPH @ 10′ DC pump pumping capacity. . . 1000 GPH @ 10′ Overall dimensions . . . . . . 10″W x 17-3/4″ H Pump housings & strainers . . . . . . . . . . . . . . Primary – Cast iron housing with non-corrosive strainer Backup – Non-corrosive housing and strainerPage 2

Installing the Pipe and Pump

sump pit is not clean, remove as much of the debris as possible. You should place a pump

move smoothly without hitting the pump or the wall

The Basement Watchdog combination system is compact and will fit in a sump pit as small as

stand or bricks on the floor of the sump pit to raise the pump above the debris.

of the sump pit. 11. Position the top of the pump

10″ wide and 14″ high (the size of a 5 gallon

If you are replacing an old sump pump, unplug

system pipe so it is directly

bucket). It measures 173/4″ inches from the

the pump from the outlet.

below the discharge pipe.

bottom of the pump to the top of the Y-

1. Remove the check valve or rubber union. If the

Slide the rubber union down

connector where it will be attached to the

existing system is installed without a check

until half of the rubber union

discharge pipe.

valve or rubber union, saw the pipe apart

is covering the pump pipe,

Use a pit that conforms to all local codes, and check the code to see if a gate

above the sump pit per #3 below. Discard the check valve. The Basement Watchdog system contains built-in check valves, so the old check valve will not be needed.

and the other half is covering the bottom of the discharge pipe. Tighten the hose clamp 1a screws securely.

2

valve or ball valve is required.

173/4″ 2. Remove the old pump from the pit, and

unscrew the pipe and pipe adapter from the

BOUT DU

The path of the

pump.

TUYAU

vertical discharge

3. Measure the distance from the bottom of the

pipe to an exterior

sump pit (or from the top of the bricks in the

wall should have the

sump pit) to the end of the discharge pipe.

shortest path with the fewest turns. The more turns will reduce the pumping capacity.The

Subtract 18-3/4 inches (the height of the pump system + 1 inch). Cut a piece of 1-1/2″

MESURER LA DISTANCE

TUYAU DE DRAIN

discharge pipe must be positioned in a

rigid PVC pipe to that length.

downward slope so any remaining water will

drain away. Failure to do this will prevent water

4. (a) Connect this piece to the discharge pipe

from exiting the pit and damage the pump if the line freezes. (see Diagram A)

by cementing the two pieces together with a 1-1/2″ PVC pipe connector. (Follow the

3

4a

4b

The system should be placed on a flat surface free from dirt and debris. If the bottom of the

instructions on the PVC pipe cleaner and cement.) or, (b) connect the two pieces of pipe together with a rubber union.

Diagram APUSH to Test or Reset

5. Remove the assembled pump system from the shipping carton by lifting the strap at the bottom of the unit and supporting the top of the unit with your hand. Stand the unit on the ground near the sump pit. Visually inspect your pump. Products may be damaged during shipping. If the product has been damaged, contact your place of purchase or Glentronics before installation.

6. Slip the lifting strap off of the pump.

5

7

7. Remove the attached cords and controllersfrom the carton and place them next to the pump system. BE SURE THE CORDS AND CONTROLLERS DO NOT FALL INTO THE SUMP PIT DURING THE INSTALLATION.

8. Loosen the hose clamps on the enclosed rubber union, and slide the union up on the discharge pipe until it is even with the bottom of the pipe.

9. Lift the combination system by the handle on the primary pump and lower it into the sump pit. Make sure it is level.

10. Inspect the two float switches. They should

8

both be vertical and positioned so that they

9&10

11

Page 3

Preparing the BatteryThe Basement Watchdog Emergency Standby Battery has been designed to run this system for 50 hours, based on a 10% duty cycle. However, most of the time the pump will turn on and off, and the battery will run the pump intermittently for days. In addition the unique materials in the battery enable it to last longer in standby service.To extend the run time of the pump, use the Basement Watchdog Big Standby Battery. It will run this pump for 100 hours, based on a 10% duty cycle. Why will it run longer? Because the Big battery is rated for other Basement Watchdog pumps that draw more power (amps). The emergency pump puts less drain on the battery, so the battery lasts longer.NOTE: The battery will not run the primary pump.CAUTION· The use of automotive batteries is NOT recommended. Automotive batteries are not designed for this application. They will only run the pump for a short time and will have a shorter life than a standby battery.· The battery fluid sensor and cap are designed to fit the Basement Watchdog batteries. Measuring the battery fluid is one of the most important features of the system; since about 80% of backup sump pump failures are the result of a battery that has dried out.· The internal construction of some wet cell batteries may not be compatible with this system. Glentronics can not guarantee the compatibility of other brands of batteries. The use of a Basement Watchdog battery is HIGHLY recommended.! DANGERDO NOT insert the fluid sensor into any battery except a Basement Watchdog battery. DO NOT use the enclosed battery cap on any battery except a Basement Watchdog battery. DO NOT drill a hole in the cap or the top of another brand of battery to accommodate the fluid sensor. Batteries emit explosive gases, which can cause serious injury or death.PREPARING THE BASEMENT WATCHDOG STANDBY BATTERYThe Basement Watchdog batteries are shipped dry (without acid) so they never lose power

before you take them home. A battery is activated when the acid is added, and then it slowly begins to deteriorate as it ages. By adding the acid just before use, the battery will always be fresh. Use 1.265 specific gravity battery acid to fill the battery. It is available where you purchased the battery.NOTE: Basement Watchdog batteries now come in two configurations. The tops of the batteries look different, and the directions for filling the batteries and connecting the fluid sensor will vary slightly. Instructions for both batteries follow. If the top of your battery looks like photo A, follow the instructions on this page. If the top of your battery looks like photo B on page 5, follow the instructions on page 5.! DANGER/POISONContains sulfuric acid. Wear eye and clothing protection. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eyes, flush with water for 10 minutes and get medical attention. Review the safety instructions on page 1.1. If you have not purchased a battery box, place a plastic garbage bag on the floor with some paper towels or newspaper on top of it while you are filling the battery. Place the dry (unfilled) battery on top of the paper. After you have purchased a battery box, place it directly on the floor and place the battery in it. ALWAYS keep the cover secured on the battery box.2. Remove the foil seal on the top of the battery.3. (a) Carefully push in the perforated tab at the top of the acid pack. Lift up the large tab and pull out the dispensing hose. Hold the hose upright above the pack and squeeze the hose forcing all the acid back into the pack. (b) Position the acid pack and battery as shown at the right. Pinch the end of the hose together and cut off the tip. Insert the end of the hose into each cell. Control the flow by pinching the hose with thumb and forefinger. Fill each cell of the battery to a level just covering the battery plates, and then go back and top off each cell equally. It is important to have the cells filled equally or the battery will not operate properly. The acid should reach a level about 3/16″ below the cap rings. (Diagram B)A newly filled battery will sometimes require additional acid after about ten minutes. Reexamine the fill level and add additional acid, if

BATTERY A

2

1

3a

necessary. The battery acid may bubble at this time and give off a sulfur-like smell, but this is normal. After the battery has been filled, screw the caps on the top of the battery.

Within 15-30 minutes of adding acid, the battery will be 70-80% charged. The system will then finish charging the battery. During this trime, the alarm may sound. This is normal.

Remove the paper and plastic bag from beneath

3b

the battery. Roll it up with the plastic on the

outside and place it in the trash.

BATTERY TERMINALS BATTERY CAP RINGS

Diagram B

2nd LEVEL 1st LEVELPLATES CELL WALL

1. Fill to 1st level, cover the plates2. Then fill to 2nd level, just below the bottom of the cap rings

CROSS SECTION OF BATTERY

Do not throw an old battery in the trash. Take it to a service station or recycling center.

Page 4

BATTERY BIf your battery looks like the battery above, follow these directions. 1. If you have not purchased a battery box,place a plastic garbage bag on the floor with some paper towels or newspaper on top of it while you are filling the battery. Place the dry (unfilled) battery on top of the paper. After you have purchased a battery box, place it directly on the floor and place the battery in it. ALWAYS keep the cover secured on the battery box. 2. Remove the two battery caps by carefully prying them up with a screwdriver. Place the screwdriver in the groove in the middle of the cap on the top of the battery. DO NOT lift the cap by prying up it from the groove on the side of the battery. It may damage the vent. 3. (a) Carefully push in the perforated tab at the top of the acid pack. Lift up the large tab and pull out the dispensing hose. Hold the hose upright above the pack and squeeze the hose forcing all the acid back into the pack.1

(b) Position the acid pack and battery as shown below. Pinch the end of the hose together and cut off the tip. Insert the end of the hose into each cell. Control the flow by pinching the hose with thumb and forefinger. Fill each cell of the battery to a level just covering the battery plates, and then go back and top off each cell equally. It is important to have the cells filled equally or the battery will not operate properly. The acid should reach a level about 3/16″ below the cap rings. (Diagram B) A newly filled battery will sometimes require additional acid after about ten minutes. Reexamine the fill level and add additional acid, if necessary. The battery acid may bubble at this time and give off a sulfur-like smell, but this is normal. After the battery has been filled, press the two caps on the top of the battery. Within 15-30 minutes of adding acid, the battery will be 70-80% charged. The system will then finish charging the battery. During this trime, the alarm may sound. This is normal. Remove the paper and plastic bag from beneath the battery. Roll it up with the plastic on the outside and place it in the trash.CAUTION When you fill the battery for the FIRST time, it will be the ONLY time you add acid to the battery. In the future, when the fluid level is low, add distilled water to the cells. Never add more acid.3a

Battery MaintenanceMeasuring the battery fluid level is one of the most important features of the system. It is important to check the battery fluid levels at least once every 4-6 months. Detailed instructions on adding distilled water to the battery can be found within the Understanding the Warnings & Alarms section of this manual(page 11, 2 Water). If you are not using aBasement Watchdog standby battery, you cannot use the battery fluid sensor. You will need to attach the fluid sensor to the POSITIVE (+) post of the battery or the alarm will sound continuously. The system will NOT warn you if the fluid level is low in this configuration. You will need to check your battery every couple of months to see if it needs water. If the battery dries out, the system will not work. If you are using a maintenance free battery or sealed AGM battery you will also need to attach the fluid sensor to the POSITIVE (+) post of the battery or the alarm will sound continuously.System Connections! DANGERRisk of electrical shock or battery explosion, which can cause serious injury or death. Unplug the main AC pump to avoid electrical shock. Wear eye protection. Work in a wellventilated area. Do not smoke or allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery. If battery acid contacts eyes, flush with water for 15 minutes and get prompt medical attention. Review the safety instructions on page 1.MOUNTING THE CONTROLLERWhen you position the backup system control

Diagram CPUSH to Test or Resetunit on the discharge pipe, be sure the charger cord will reach the AC power outlet and the pump cable and the float switch will reach the bottom of the sump. Position the unit in a wellventilated area. Do not place anything on top of the battery. (Diagram C) 1. Mounting the backup control unit: (a)Thread one plastic cable tie through the two mounting brackets on the back of the control unit. (b) Secure the controller to the discharge pipe by wrapping the tie around the pipe and pulling it tight.-2. Connecting the backup pump: Remove the security tag from the pump and plug the pump wires into the pump connector on the back of the control unit.

2

3b

Page 5

1a

1b

2

3. Installing the battery fluid sensor: Remove the cover and fan the area around the top of the battery with a piece of cardboard (or another non-metallic material) to remove any hydrogen or oxygen gas that may have been emitted from the battery. (a) If you have battery A, replace the battery cap that is 2nd from the POSITIVE (+) post of the battery with the battery cap that is provided in the Basement Watchdog package. An arrow on the top of the battery marks this position. There are two holes in the battery cap. Insert the fluid sensor in the hole that is off-center on the top of the cap. Do not glue the sensor into the cap. (b) If you have battery B, a hole has been molded into the top of the battery to accept the fluid sensor rod. The sensor hole is marked by the label on top of the battery. Hold the sensor straight and press it firmly into the hole all the way up to the connector. Do not bend the sensor rod.3a

3b

POSITIVE 4 POST

NEGATIVE POST

If you are not using the Basement Watchdog battery, you cannot use the battery fluid sensor. However, you must attach the sensor to the POSITIVE (+) post of the battery or the alarm will sound continuously. The Basement Watchdog sump pump system will not warn you if the fluid level is low in this configuration. You will need to check your battery every couple of months to see if it needs water. If the battery dries out, the system will not work. If you are using a maintenance free battery or sealed AGM battery you will also need to attach the fluid sensor to the POSITIVE (+) post of the battery or the or the alarm will sound continuously.4. Connecting the battery: Remove the wing nuts from the battery terminals. Remove the security tag from the battery cables. Attach the battery cables to the battery…the WHITE wire to the NEGATIVE (-) post, and then the BLACK wire to the POSITIVE (+) post. Replace the wing nuts and tighten. Note: Connecting the cables to the wrong posts will damage the controller.5. Connecting the charger: Immediately plug the charger into the charger jack on the back of the control unit, then into an AC outlet on the wall.6. If the pump alarm is sounding, press the RED button to silence the alarm.7. Replace the battery box cover.8. Connecting the primary pump: Plug the piggyback controller into a properly grounded 3-prong outlet. Then plug the

5a

5b

6

8

9

primary pump into the receptacle on the controller.9. For a neater installation, secure the cables from the controllers to the discharge pipe in a couple places with the additional cable ties. Make sure the wires are not touching each other or overlapping each other.10. After the initial installation, be sure to check the pump operation by filling the sump with water and observing the pump through several full cycles. The primary pump should run for 10 seconds after the lower float drops.11. After the initial installation, be sure to check each pump for proper operation. To check the primary pump, fill the sump with water and observe the pump through several full cycles. The primary pump should run for 10 seconds after the lower float drops. To check the operation of the backup pump, manually raise the backup float and let it go. The backup pump will run for approximately 45 seconds. After the backup pump has stopped, push the RED button.Product OperationThe dual float switch on the primary pump contains two large floating rings enclosed within a protective cage. Water will lift the bottom float by 1/4″, which will activate the pump. If for any reason the lower float does not activate the pump, the water will rise to the second float, and it will activate the pump. As the pump evacuates the water from the pit, the floats will drop. The pump will run for an additional 10 seconds to extend the cycle after the lower float drops. The blue controller for the primary pump powers this switch. During a power outage, or if more water is entering the sump than the primary pump can handle, the backup pump will automatically begin pumping. It also has a dual float switch,

so if one float fails to activate the pump, the second float will activate the pump as soon as the water reaches that level. As the water recedes below the float switch, a timer in the control unit will run the pump an additional 25 seconds to evacuate the pit. The backup float switch wire includes a connector that can be separated from the controller when the wire needs to be threaded through small openings such as a sump pit cover. Be sure the float switch wire connection is secure before final installation. While the pumps are active, water will come out of the 1/8″ hole that is located on the top of the main pump and the 3/16″ hole located in the elbow of the backup pump. This is normal. The holes are needed to prevent an air lock within the system. DO NOT obstruct the holes or an air lock may prevent the system from activating. Batteries and sump pumps need maintenance. The control unit on the backup system monitors the battery and power conditions, and sounds an alarm when maintenance is required. Below is an explanation of the warnings and alarms.Understanding the Warnings & AlarmsThe Basement Watchdog backup control unit features a series of warning lights that pinpoint potential problems. In addition, an alarm sounds to alert you to the problem. In some cases the lights and alarm will go off automatically when the problem has been solved. In others, the RED button must be pushed to silence the alarm. Refer to the table on page 7 for a quick review of the features and their corresponding alarm status.Page 6

Warning POWER WATER PUMPSYSTEM BATTERY

Alarm can be Alarm shuts off

silenced before automatically

problem is when the problem

corrected

is corrected

Yes

Yes

No

Yes

Yes

No, push

RED button

No Alarm

No Alarm

No

Yes

SILENCING THE ALARM DURING AN EMERGENCYThe Basement Watchdog backup sump pump system is equipped with a switch that will silence the audible alarm during an extended emergency. The POWER and PUMP alarms can be silenced during a power outage or during heavy rains when the pump is activated repeatedly.To silence the POWER and PUMP alarms, slide the audible alarm switch to OFF. The POWER and/or the PUMP light will remain on, but the audible alarm will not sound.When the emergency has ended, slide the switch to the ON position to resume the full monitoring capability, or you will not be warned the next time an emergency occurs.

· 1 · 2 · 3 · 4 ·5Page 7

The WATER and BATTERY alarms cannot be silenced. Both require immediate attention.1 PowerThere are several causes for power failure. The most common is a power outage by your electric company. During this emergency, the Basement Watchdog system will automatically switch to battery power and protect your basement from flooding. You can silence the POWER alarm by sliding the audible alarm switch to OFF. The alarm will be silenced, but the light will stay on. The system will continue to operate while the power alarm is silenced. Be sure to slide the switch to the ON position when power is restored to resume full monitoring capability.1. If the power is on in the rest of the house, check the outlet, the home circuit breaker or the fuse box for failure, and correct the problem.2. Check the charger. Make sure it is securely plugged into the wall outlet. Make sure the power outlet is working.3. Check the charger plug that fits into the rear panel of the control unit. Make sure it is securely plugged into the control unit.

2

3

The control unit must receive 115 volts AC +/5% from the AC outlet. Any voltage lower than 110 volts will activate the POWER alarm. Lower voltages can be caused by utility brown outs or a heavy power draw from other appliances on the same circuit.If all the connections are secure and the wall outlet is operating, but the POWER warning light is still on, replace the charger unit. Contact Glentronics, Inc. at 800-991-0466, option 3.2 Water! DANGERRisk of electrical shock or battery explosion, which can cause serious injury or death.

Wear eye protection. Work in a wellventilated area. Do not smoke or allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery. If battery acid contacts eyes, flush with water for 15 minutes and get prompt medical attention. Review the safety instructions on page 1.If this warning light and alarm are on, you need to add distilled water to the battery. (This alarm cannot be silenced. When the battery is refilled and the sensor is replaced, the alarm will go off automatically.) To refill the battery:1. Unplug the charger and the blue AC pump controller from the wall outlet.2. Remove the cover of the battery box and fan the area around the top of the battery with a piece of cardboard (or another nonmetallic material) to remove any hydrogen or oxygen gas that may have been emitted from the battery.3. Then unscrew the wing nuts and remove the battery cables and the fluid sensor from the battery.4. Remove the battery caps. Add distilled water to each cell. If distilled water is not available, tap water with a low mineral content may be used. Well water is not recommended. NEVER ADD MORE ACID. Fill the battery to level 2 as shown in Diagram B on page 4. (The Basement Watchdog battery filler will automatically fill the level to the correct height. See enclosed order form.)

2

3

REMOVE

4555. Using a paper towel, clean the underneath portion of the battery cap that contains the fluid sensor. Replace the battery caps and the fluid sensor. Be sure the fluid sensor is positioned in the 2nd cell from the positive post. Depending on which battery you own, the sensor will fit in the top of the battery cap or in the molded hole on the top of the battery. The location is marked with an arrow on the top of the battery. The warning light and alarm will turn off automatically when the battery is refilled and the sensor is replaced.6. Replace the battery cables, the WHITE to the NEGATIVE (-) post, and the BLACK to the POSITIVE (+) post. Replace the wing nuts and tighten.7. Replace the battery box cover. 8. Plug the charger and the blue AC controllerback into the outlet.3 PumpWhen the water rises in the sump pit and lifts the float switch, the pump will begin pumping, and the PUMP light and alarm will turn on. The pump warning stays on to alert you to the fact

that the standby system was used to empty the water from the sump. Try to determine what caused the system to activate. · Check the main pump for failure. It may notbe working, the float switch may be stuck, or the pump may be too small to handle the inflow of water. · Make sure the check valves are working and installed correctly. They may need to be replaced. (See page 12 for check valve locations). · Make sure the discharge pipe is not clogged or frozen.· If the power was out, and the backup pump was activated, you need to push the RED button to silence the alarm.During a power outage or times when the pump is activated repeatedly, you can temporarily silence the alarm by sliding the Audible Alarm switch to OFF. When the primary pump has resumed normal operation and the backup pump is no longer activating repeatedly, slide the switch to the ON position to resume the full monitoring capability. The alarm and pump light will still be on. Push the RED button to silence the alarm.REPLACING THE BACKUP PUMPBefore you begin this process you will need a new backup pump. You may also want to change

YOU WILL BE DISCONNECTING ALL THE WIRES. BE SURE THEY DO NOT FALL INTO THE SUMP PIT. SEE DIAGRAM ON PAGE 12 FOR PARTS DESCRIPTION.the check valves at this time. The backup pump uses a 1-1/4″ check valve, the primary pump uses a 1-1/2″ check valve. (See parts list on page 12.)! DANGERRisk of electrical shock or battery explosion, which can cause serious injury or death. Wear eye protection. Work in a wellventilated area. Do not smoke or allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery. Review the safety instructions on page 1.1. Unplug the primary pump from the blue controller.2. Remove the charger plug from the back of the backup controller.3. Unplug the backup pump from the back of the backup controller.4. Remove the cover of the battery box by pushing in the tabs on the front and back, then lifting up. Fan the area around the top of the battery with a piece of cardboard (or another non-metallic material) to remove any hydrogen or oxygen gas that may have been emitted from the battery.5. Remove the sensor from the battery.6. Remove the battery wires from the battery terminals. Be sure they do not touch each other while one is connected to the battery.7. Slowly loosen the rubber union on the top of the combination pump assembly to separate the pipes. The water trapped in the pipe will pour out into the sump as the rubber union is loosened.8. Separate the pump assembly from the rubber union and lift it out of the sump by the handle on the primary pump.9. Turn the assembly up side down over the sump pit to allow the remaining water in the system to drain.10. Loosen the screws on the no-hub connector on the elbow of the backup pump.11. Unscrew the screw on the bottom of the pump

1

2,3

7

8

10

11

bracket with a Phillips head screwdriver, and lift the pump off of the bracket. Then pull the pump down out of the no-hub connector.12. Unscrew the check valve on the elbow of the backup pump. Now reverse the process.13. Screw the check valve on to the new pump. (You can use the existing check valve, or preferably replace it with a new one.)14. You must drill a 3/16″ hole in the elbow of the new pump to prevent an air lock in the system. An air lock will prevent the pump from operating. Drill the hole on a downward slope below the check valve on the elbow.15. Push the pump and check valve back up into the no-hub connector, and place the pump on the pump bracket.16. Screw the pump onto the bracket.

REMOVE 5,6912 17. Tighten the hose clamp on the no-hubconnector. 18. Lower the pump system back into the sump pit. 19. Connect the top of the system to the rubberunion and tighten the hose clamp. 20. Connect the battery cables to the batteryterminals, WHITE to the NEGATIVE (-) post, and BLACK to the POSITIVE (+) post. 21. Insert the fluid sensor into the top of the battery and replace the cover of the battery box. 22. Plug the backup pump into the back of the backup controller. 23. Plug the charger into the back of the backup controller. 24. Plug the primary pump into the blue controller.Page 8

REPLACING THE PRIMARY PUMPBefore you begin this process you will need a new AC pump. You may also want to change the check valves at this time. The backup pump uses a 1-1/4″ check valve, the primary pump uses a 1-1/2″ check valve. (See parts list on page 12.)! DANGERRisk of electrical shock or battery explosion, which can cause serious injury or death. Wear eye protection. Work in a wellventilated area. Do not smoke of allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery. Review the safety instructions on page 1.REFER TO THE PHOTOS AT RIGHTYOU WILL BE DISCONNECTING ALL THE WIRES. BE SURE THEY DO NOT FALL INTO THE SUMP PIT. SEE DIAGRAM ON PAGE 12 FOR PARTS DESCRIPTION.1. Unplug the primary pump from the blue controller.2. Remove the charger plug from the back of the backup controller.3. Unplug the backup pump from the back of the backup controller.4. Remove the cover of the battery box by pushing in the tabs on the front and back, then lifting up. Fan the area around the top of the battery with a piece of cardboard (or another non-metallic material) to remove any hydrogen or oxygen gas that may have been emitted from the battery.5. Remove the sensor from the battery.6. Remove the battery wires from the battery terminals. Be sure they do not touch each other while one is connected to the battery.7. Slowly loosen the rubber union on the top of the combination pump assembly to separate the pipes. The water trapped in the pipe will pour out into the sump as the rubber union is loosened.8. Separate the pump assembly from the rubber union and lift it out of the sump by the handle on the primary pump.Page 9

1

2,3

REMOVE 5,6

7

8

9

10,11 SLIDE OUT

12,13

15

9. Turn the assembly up side down over the sump pit to allow the remaining water in the system to drain.10. Loosen the hose clamp on the caged float switch and remove the float switch.11. Cut the cable ties on the backup float switch and remove it.12. Loosen the hose clamp on the top of the nohub connector on the primary pump.13. Loosen the hose clamp on the top of the nohub connector on the backup pump.14. Remove the Y-connector.15. Unscrew the primary pump check valve.16. Carefully slide the backup pump and bracket

16out of the handle of the primary pump. Now reverse the process.17. Carefully slide the backup pump and bracket into the handle of the new primary pump.18. Screw in the check valve on the top of the primary pump. (You can use the existing check valve, or preferably replace it with a new one.)19. Connect the Y-connector to the top of the check valve with the no-hub connector and tighten the hose clamp.20. Connect the backup pump to the other side of the Y-connector with the other no-hub connector.21. Replace the caged float switch by tightening it with its hose clamp.

22. Replace the backup pump float switch using 2 new cable ties. Make sure the float moves easily, and will not get hung up on the pump.23. Lower the pump back into the pit by the handle of the primary pump.24. Connect the top of the system to the rubber union and tighten the hose clamp.25. Connect the battery cables to the battery terminals, WHITE to the NEGATIVE (-) post, and BLACK to the POSITIVE (+) post.26. Insert the fluid sensor into the top of the battery and replace the cover of the battery box.27. Plug the backup pump into the back of the backup controller.28. Plug the charger into the back of the backup controller.29. Plug the primary pump into the blue controller.4 SystemThis green light should always be flashing. It indicates that the system is operating, and the battery is connected. If this light is off: · Check the charger. Make sure it is securelyplugged into the wall outlet.· Check the charger plug that fits into the rear panel of the control unit. Make sure it is securely plugged into the control unit.· If all connections are secure and the wall outlet is operating, but the POWER warning light is flashing, replace the charger. Call Glentronics parts department at 800-9910466, option 3.

5 BatteryThis light and alarm will go on when the control unit senses that the battery has approximately 1/2 hour of continuous pumping energy left. This alarm cannot be silenced. It indicates that your battery is discharged or defective and immediate action needs to be taken to replace the battery or clean the terminals. This alarm will sound when: · Corrosion on battery terminals and/or cablerings is preventing the battery from charging properly · The battery is getting old and should be replaced · The pump has been running for many hours and the battery is dischargedCheck the battery cables and the battery terminals for corrosion. Clean and tighten them as needed. The procedure is described on the following page.If the battery alarm goes on while the pump is running and the power is out, you will have a minimum of 1/2 hour of pumping time to replace the battery. (In most cases, the pump does not run continuously, and therefore, you actually have a longer time to replace it.) You will not be able to silence the alarm. Left unattended, the basement will flood. In a severe emergency, if a replacement battery is not available, you could temporarily use your car battery. Once the AC power is restored, the battery will recharge automatically, unless it is old or damaged. The alarm will go off when the AC power is restored and the pumping energy reaches 1/2 hour or more. In the event that your Basement Watchdog backup sump pump has pumped for an extended period of time, the battery may be very depleted. In this condition, when the AC power is returned to the unit, a battery alarm will continue to sound. The battery may need a longer period to recharge.2

For a faster recharge, an automotive or marine battery charger can be used to recharge the battery. Follow the manufacturer’s instruction and safety information included with the charger. Make sure the backup control unit is disconnected from the battery. If the battery is relatively new and the battery alarm is activated, before you replace the battery, call the Glentronics service department. The phone number is 800-991-0466, option 3.TO CLEAN THE BATTERY TERMINALS AND CABLES! DANGER Risk of electrical shock or battery explosion, which can cause serious injury of death. Wear3

4

REMOVE

5 6

7

8

9

eye protection. Work in a well-ventilated area. Do not smoke or allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery. If battery acid contacts eyes, flush with water for 15 minutes and get prompt medical attention. Review the safety instructions on page 1.1. Unplug the charger and blue AC controller from the wall outlet.2. Remove the cover of the battery box by pushing in the tabs on the front and back, then lifting up.3. Fan the area around the top of the battery with a piece of cardboard (or another nonmetallic material) to remove any hydrogen or oxygen gas that may have been emitted from the battery.4. Remove the fluid sensor from the battery. Unscrew the wing nuts. Remove the battery cables.5. Clean the battery posts with a battery terminal cleaner or a wire brush.6. Clean any corrosion off of the ring connectors on the ends of the battery wires. Us a stiff brush or sandpaper. DO NOT apply corrosion resisting sprays or pads to the terminal rings or posts after you have cleaned them, since this could prevent the system from charging properly.7. Replace the fluid sensor in the top of the battery. Then replace the battery cables, WHITE to the NEGATIVE (-) post and BLACK to

the POSITIVE (+) post. Tighten the wing nuts and replace the cover of the battery box. 8. Plug the charger and the blue AC pump controller back into the wall outlet. 9. You may have to press the RED button to silence the PUMP alarm.REPLACING THE BATTERY! DANGER Risk of electric shock or battery explosion, which can cause serious injury or death. Wear eye protection. Work in a wellventilated area. Do not smoke or allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery. If battery acid contacts eyes, flush with water for 15 minutes and get prompt medical attention. Review the safety instructions on page 1. REFER TO THE PHOTOS BELOW AND ON PAGE 11 Basement Watchdog batteries come in two configurations. (A) One has six battery caps that screw into the top of the battery, and the fluid sensor fits in the cap with the two holes. (B) The other battery has two large caps that each snap over 3 holes. The sensor hole in this battery is molded in the top of the battery.AB1. Unplug the charger and blue AC controller from the wall outlet.2. Remove the cover of the battery box by pushing in the tabs on the front and back, then lifting up. Fan the area around the topPage 10

of the battery with a piece of cardboard (or another non-metallic material) to remove any hydrogen or oxygen gas that may have been emitted from the battery.3. Remove the fluid sensor from the top of the battery. If the sensor was in the cap of the battery, remove the battery cap and save it for use in a new battery.4. Unscrew the wing nuts and remove the battery cables.5. Remove the old battery. Fill the battery following the instructions on page 4.6. Clean any corrosion off of the wire ring connectors on the end of the battery cables.

2

3,4

REMOVE

5

6 Page 11

POSITIVE 7 POST

NEGATIVE POST

8a

8b

9

10

Use a wire brush or sandpaper. DO NOT apply corrosion resisting sprays or pads to the terminal rings or posts after you have cleaned them, since this could prevent the battery from charging properly.7. Replace the battery cables, WHITE to the NEGATIVE (-) post and BLACK to the POSITIVE (+) post.8. (a) If the new battery has six caps, rinse and dry the cap with the extra hole from the old battery to remove any residue. Replace the battery cap that is 2nd from the POSITIVE post with the cap from the old battery. Insert the fluid sensor in the cap and put the cap

you removed from the new battery on the old battery. (b) If the new battery has the sensor hole molded in the top you will not need to save the cap from the old battery, press the sensor firmly into the hole. Do not bend the sensor rod.9. Plug the charger and the blue AC controller into the wall outlet. Replace the cover of the battery box.10. You may have to press the RED button to silence the PUMP alarm.

TEST BUTTON

The TEST button may be used to check the backup pump and system. Push the TEST button. This will activate the pump for as long as youhold the button.

TESTING THE BACKUP FLOAT SWITCHIt is important to manually test the float switch periodically or after any maintenance.

Lift the float up

and let go. This

will activate the

pump.The control

unit will run the

pump

for

approximately 45

LIFT FLOAT

seconds so it can

empty all the

water in the

sump pit. If

there is no water in the pit, the pump can run

dry for this amount of time. The alarm will

sound and the PUMP light will go on. After the

pump has stopped, push the RED button to

silence the alarm. If the RED button is pressed

before the pump has stopped, the alarm will go

off temporarily. Wait for the pump to stop

pumping, and then push the RED button to

completely silence the alarm.

TESTING THE PRIMARY PUMP FLOAT SWITCHLift the float within the cage with a pencil or other non-metallic item and let it drop. The pump will run for an additional 10 seconds after the float returns to the original position. It will not damage the pump to run it for this short time if the sump pit is dry. However, DO NOT

LIFT FLOAThold the float up for an extended time without water in the sump. While the pumps are active, water will come out of the 1/8″ hole located on the top of the main pump and the 3/16″ hole located in the elbow of the backup pump. This is normal. The holes are needed to prevent an air lock within the system. DO NOT obstruct the holes or an air lock may prevent the system from activating.MAINTENANCE CHECK LISTMaintenance should be performed 1-2 times per year. 1. Lift the float switches on both pumps asdescribed above. 2. Remove all debris from the bottom of the pitand the pump strainers. 3. Remove all debris floating in the water. 4. Remove all debris from the float switch cage. 5. Fill the pit with water. Make sure the pumpsturn on at the intended levels. 6. While the pump is running, make sure thepump is evacuating water at a good pace and water is coming out of the 1/8″ air vent on the top of the pump and the 3/16″ air bleed hole in the elbow of the backup pump. Make sure the air vent and air bleed hole are clear of debris. 7. Remove the fluid sensor and cap from the battery and rinse any black buildup from the cap. Replace the cap and fluid sensor. 8. Check and clean battery terminals. 9. Check battery fluid levels once every four to six months.

PARTS & SERVICE INFORMATIONYou can receive technical support, parts or service information by calling Glentronics, Inc. at 800-991-0466, option 3, or by visiting the website at www.basementwatchdog.com. Send your unit to the following address for repairs:Glentronics, Inc. 645 Heathrow Drive, Lincolnshire, IL 60069

Replacement Parts List

Description

Part No.

PUSH to Test or Reset

1/3 HP AC sump pump

SIT-33NS

Caged dual float switch with piggyback controller BWC2

Emergency backup pump

1011004

Emergency control unit

BWE-CONT

“Y” PVC pipe fitting

1120007

Support bracket for backup pump

1121003

Battery cap with hole for the fluid sensor

1125000

Charger for backup pump

1015003

Backup dual float switch

1020009

Backup pump locking screw (#12 x 1/2″ pan head)* 1100018

1-1/4″ check valve for backup pump*

1141000

1-1/2″ check valve for primary pump*

1141001

No-hub stainless steel connectors*

1142000

1-1/2″ rubber union*

1142001

2″ hose clamp*

1122002

Cable tie*

1122000

*Stock items available in plumbing department

Call 800-991-0466, option 3 to order parts.

BOTTOM VIEW

SIDE VIEW

Page 12

Primary Pump Troubleshooting Guide! DANGER Read safety warnings & instructions before attempting any repairs or maintenance.

Potential Cause

THE PUMP WILL NOT START OR RUN

Solutions

Pump is not plugged in . . . . . . . . . . . . . . . . . . . . Plug pump in properly (see instructions)

No AC power . . . . . . . . . . . . . . . . . . . . . . . . . . . . Check circuit breaker or fuse

Poor power source . . . . . . . . . . . . . . . . . . . . . . . . Check circuit line wires, cable and outlet

Locked impeller . . . . . . . . . . . . . . . . . . . . . . . . . Remove strainer and clear obstruction

Defective float switch . . . . . . . . . . . . . . . . . . . . . Replace float switch with new float switch

Defective pump . . . . . . . . . . . . . . . . . . . . . . . . . Replace pump with new pump

Potential Cause THERMAL PROTECTOR TRIPPING OR NOT FUNCTIONING

Solutions

Locked impeller . . . . . . . . . . . . . . . . . . . . . . . . . Remove strainer and clear obstruction Incorrect power supply . . . . . . . . . . . . . . . . . . . . Check power supply source and voltage Pump running continuously with no water present . . Check float switch

Potential Cause

PUMP STARTS AND STOPS TOO FREQUENTLY

Solutions

Float switches mounted too low . . . . . . . . . . . . . . Raise both float switches Water back flowing from pipe . . . . . . . . . . . . . . . . Install or replace check valve Malfunctioning float switch . . . . . . . . . . . . . . . . . Replace float switch with new float switch

Potential Cause

PUMP WILL NOT SHUT OFF

Solutions

Clogged or frozen discharge . . . . . . . . . . . . . . . . . Blocked intake strainer . . . . . . . . . . . . . . . . . . . . One or both of the floats is obstructed and cannot drop down . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Defective float switch . . . . . . . . . . . . . . . . . . . . . Check valve is stuck . . . . . . . . . . . . . . . . . . . . . .

Clear blockage or thaw frozen line Clear debris from intake strainerClear debris from inside the float cage (Loosen nut on top of float, then remove c-clip on bottom of float. Remove debris. Tighten nut on top of float, then replace c-clip on bottom of float.) When reassembling the float, the magnetic strip on the inside of the float should be facing down. Replace float switch with new float switch Replace check valve

Potential Cause

INSUFFICIENT OR NO WATER VOLUME

Solutions

Check valve on secondary pump will not close and water re-circulates within the system . . . . . . . . . . . Partially blocked impeller . . . . . . . . . . . . . . . . . . . Clogged or frozen discharge pipe . . . . . . . . . . . . . . Broken or leaking pipe . . . . . . . . . . . . . . . . . . . . . Low power voltage . . . . . . . . . . . . . . . . . . . . . . . Check valve is stuck . . . . . . . . . . . . . . . . . . . . . .There is an air lock within the system . . . . . . . . . .

Replace the check valve on the secondary pump Remove strainer and clear obstruction Clear blockage or thaw frozen line Repair pipe Check power voltage, wires and cable condition Replace check valve Make sure the air relief valve located on the top of the primary pump is clear of debris

Potential Cause

ABNORMAL SOUND OR VIBRATION

Check valve is broken . . . . . . . . . . . . . . . . . . . . . Replace the check valve Blocked intake screen . . . . . . . . . . . . . . . . . . . . . Clear debris from intake screen Defective pump . . . . . . . . . . . . . . . . . . . . . . . . . Replace pump

Solutions

If the above solutions do not resolve the problem, follow the instructions within this manual to disconnect the system from the outlet and battery terminals, then reconnect the system and push the reset button. If the problem continues, contact customer service.Page 13

Backup Pump Troubleshooting Guide! DANGER Read safety warnings & instructions before attempting any repairs or maintenance.

Potential Cause

BATTERY FLUID LOW

Solutions

The battery fluid is low . . . . . . . . . . . . . . . . . . . . . . Add distilled water to each cell of the battery The fluid sensor is installed improperly . . . . . . . . . . . The fluid sensor should be inserted into the designatedhole on the top of the battery and pushed down Not using a Basement Watchdog battery . . . . . . . . . . This feature cannot be used. Attach the fluid sensor tothe positive post of the battery

Potential Cause

BATTERY PROBLEM

Solutions

Terminals are corroded . . . . . . . . . . . . . . . . . . . . . . Clean terminals and cables Cables are loose . . . . . . . . . . . . . . . . . . . . . . . . . . . Tighten wing nuts Battery is discharged below 25% . . . . . . . . . . . . . . . Replace battery if power is out. There is only 1 hour ofcontinuous pumping power left. Battery will recharge when power is restored Battery is old or damaged . . . . . . . . . . . . . . . . . . . . Replace battery

Potential Cause

POWER FAILURE

Solutions

Power outage . . . . . . . . . . . . . . . . . . . . . . . . . . . . None. The backup pump will run off of the battery. Flip the alarm switch to the off position to silence the alarm. Be sure to flip it back to on when the power is restored.An outlet, fuse, or circuit breaker has failed . . . . . . . Try another outlet, replace the fuse, or reset the circuit breakerThe charger is unplugged from the wall or the back of the controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . Make sure the power cord is plugged in securely The control unit is receiving less than 110 volts from the outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . None, if the utility company has instigated brown outs.Otherwise, reduce the number of other appliances on the circuit

Potential Cause

PUMP WILL NOT SHUT OFF

Solutions

Backup pump is unplugged . . . . . . . . . . . . . . . . . . . Make sure the pump is securely plugged into the back of the control unitBackup pump is clogged . . . . . . . . . . . . . . . . . . . . . Remove strainer from pump and clean out any debris Backup pump is broken . . . . . . . . . . . . . . . . . . . . . . Replace the pump

Potential Cause

INSUFFICIENT OR NO WATER VOLUME

Solutions

The main AC pump failed because of a power outage . . None. The backup pump was activated when needed The water was coming into the sump faster than the main pump could evacuate it . . . . . . . . . . . . . . . . . . None. The backup pump was activated when needed The float switch on the main AC pump is stuck or defective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Free the float switch on the main pump or replace it The main AC pump is broken . . . . . . . . . . . . . . . . . . Replace the main AC pump The main AC pump could not keep up with the inflow of water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . None. The backup pump was activated as needed. If this is arecurring problem, install a higher capacity main pump The check valve is stuck and the water cannot pass through it . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Replace the check valve The discharge pipe is clogged or frozen and the water cannot pass through it . . . . . . . . . . . . . . . . . . . . . . Thaw, cleanout the blockage, or replace the discharge pipe There is a slight chance of false activation if the float switch cord is wrapped around the AC power cord . . . . Move the float switch cord away from the AC power cord The float switch is not connected to the controller . . . Check connection of the float switch to the controller There is an air lock within the system . . . . . . . . . . . . Make sure the 3/16″ weep hole is drilled in the elbow ofthe backup pump. Make sure it is clear of debris

Potential Cause

ABNORMAL SOUND OR VIBRATION

Solutions

Check valve is broken . . . . . . . . . . . . . . . . . . . . . . . Make sure check valve is functioning, or replace it Discharge pipe is clogged or frozen . . . . . . . . . . . . . Clear the discharge pipe

Limited WarrantyBy opening this package and using this GLENTRONICS, INC. product, you are agreeing to be bound by the terms of the GLENTRONICS, INC. limited warranty (“warranty”) as set out below. Do not use your product until you have read the terms of the warranty. If you do not agree to the terms of the warranty, do not use the product and return it within the return period stated on your purchase receipt from the retail store or authorized distributor where you purchased it for a refund.To the extent permitted by law, this warranty and the remedies set forth are exclusive and in lieu of all other warranties, remedies and conditions, whether oral, written, statutory, express or implied. GLENTRONICS, INC. disclaims all statutory and implied warranties, including without limitation, warranties of merchantability and fitness for a particular purpose and warranties against hidden or latent defects, to the extent permitted by law. GLENTRONICS, INC. will not be liable for any incidental, special or consequential damages for breach of any express or implied warranties on this product. In so far as such warranties cannot be disclaimed, GLENTRONICS, INC. limits the duration and remedies of such warranties to the duration of this express warranty and, AT GLENTRONICS, INC.’s option, the repair or replacement services described below. Some states (countries and provinces) do not allow limitations on how long an implied warranty (or condition) may last, so the limitation described above may not apply to you.Any and all causes of action arising from, filed as a result of or in reference to, this warranty or the products described under this warranty shall be governed by and construed under the laws of the State of Illinois. Any cause of action arising from, filed as a result of or in reference to, this warranty or the products described under this warranty shall be filed only in the Circuit Court of the 18th Judicial District, Lake County, Waukegan, Illinois, or in the Northern District of Illinois if filed in Federal Court. The maximum liability for any product described in this warranty shall be the cost of product replacement only.If any term is held to be illegal or unenforceable, the legality or enforceability of the remaining terms shall not be affected or impaired.What is Covered by this Warranty?GLENTRONICS, INC. warrants to the end purchaser that its pumps, switch and control unit products are free from defective materials and workmanship for the periods indicated below:All parts and labor (excluding installation) for a period of:· 2 years from the date of purchase, when used intermittently as a sump pumpThe defective product must be returned directly to the factory, postage prepaid with the original bill of sale or receipt to the address listed below. GLENTRONICS, INC., at its option, will either repair or replace the product and return it postage prepaid.What is NOT Covered by this Warranty?This warranty does not cover the cost or value of damaged property, including expressly any property that has been affected by water overflow, seepage or flooding. If GLENTRONICS, INC. determines that a product is deemed defective under this warranty agreement, it will repair or replace the PRODUCT ONLY. GLENTRONICS, INC. will not cover the cost to reinstall the product, nor will GLENTRONICS, INC. pay the cost of having a plumber or contractor repair or replace the product.GLENTRONICS, INC. will not repair or replace a product that was installed incorrectly. A product shall be considered “installed incorrectly” when it deviates in any way from the instructions described in this manual.This warranty does not cover product problems resulting from handling liquids hotter than 104 degrees Fahrenheit, handling inflammable liquids, solvents, strong chemicals or severe abrasive solutions; user abuse; misuse, neglect, improper maintenance, commercial or industrial use; improper connection or installation, damages caused by lightning strikes; excessive surges in AC line voltage; water damage to the controller; other acts of nature, or failure to operate in accordance with the enclosed written instructions.How to Obtain Warranty ServiceWithin thirty (30) days of the product’s defective performance, the unit must be shipped, freight prepaid, or delivered to GLENTRONICS, INC. to provide the services described hereunder in either its original carton and inserts, or a similar package affording an equal degree of protection. Products not received by GLENTRONICS, INC. at the address indicated below within thirty (30) days of the product’s defective performance will not be considered for warranty service. Products received after two (2) years from the date of purchase, fall outside of the timeframe for warranty service and will not be eligible for warranty service. The product must be returned to GLENTRONICS, INC. for inspection in order to be considered for warranty service. If the product is not returned to GLENTRONICS, INC. or the product is inspected by any person, plumber, contractor or business other than GLENTRONICS, INC., this warranty shall no longer be valid. Prior to defective operation, the unit must not have been previously altered, repaired or serviced by anyone other than GLENTRONICS, INC., or its agent; the serial number on the unit must not have been altered or removed; the unit must not have been subject to accident, misuse, abuse or operated contrary to the instructions contained in the accompanying manual. The dealer’s dated bill of sale, or installer’s invoice must be retained as evidence of the date of purchase and to establish warranty eligibility.Where are Products Sent for Warranty Service?Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069How Can I Obtain More Information?By calling 800-991-0466.Page 14

Système combiné de pompes de puisard principale et de secours

Mode d’emploi et consignes de sécurité

Table des matières

Consignes de sécurité et

instructions importantes

Précautions en matière électrique

16

Préparation de la batterie

16

Précautions à prendre vis-à-vis de la

batterie

16

Préambule

Composants fournis

17

Pièces nécessaires non fournies

17

Caractéristiques du système

17

Installation de la pompe et des

canalisations

18

Préparation de la batterie

19,20

Mode d’emploi de la batterie

20

Entretien de la batterie

20

Raccordements du système

Montage du régulateur de secours 20

Raccordement de la pompe de secours 20

Installation du capteur de niveau

de fluide de la batterie

20

Raccordement de la batterie

21

Raccordement du chargeur

21

Raccordement de la pompe principale 21

Page 15

Fonctionnement du produit

21

Explication des consignes de

sécurité et des alarmes

Arrêt de l’alarme pendant une alerte 22

Power (alimentation)

22

Water (eau)

22

Back up pump (pompe de secours) 23

Remplacement de la pompe de secours 23

Remplacement de la pompe principale 24

Système

25

Battery (batterie)

25

Nettoyage des bornes de la batterie 25

Remplacement de la batterie

26

Test du système

Test de la pompe

26

Test de l’interrupteur à flotteurs

26

Aide-mémoire d’entretien

26

Pièces de rechange et réparation

Aide technique

27

Liste des pièces détachées

et schéma

28

Guide de dépannage

29

Garantie

30

IMPORTANT : Même si votre système de pompe de puisard Basement Watchdog a été installé par quelqu’un d’autre, la lecture des consignes de sécurité figurant au présent manuel est obligatoire. Le non-respect de ces instructions risque de causer des dégâts matériels, une blessure grave ou la mort.

Consignes de sécurité et instructions importantesCONSERVER CES INSTRUCTIONS. Ce manuel contient des CONSIGNES DE SÉCURITÉ ainsi qu’un MODE D’EMPLOI importants pour le système de pompes de puisard principale et de secours Basement Watchdog. Vous aurez besoin de le consulter avant l’installation ou une intervention d’entretien. TOUJOURS conserver le présent mode d’emploi avec la pompe, de sorte qu’il soit à portée de la main.Le non-respect de ces consignes et du mode d’emploi risque d’entraîner des dégâts matériels, des blessures corporelles ou même la mort. Même si vous n’avez pas installé personnellement votre système de pompes de puisard principale et de secours Basement Watchdog, la lecture du présent manuel est obligatoire, car il contient les consignes de sécurité relatives à l’emploi et à l’entretien du système. NE PAS JETER CE MANUEL.PRÉCAUTIONS EN MATIÈRE ÉLECTRIQUE! AVERTISSEMENTRisque de danger électrique et d’incendie. Danger de mort, de blessure grave, d’électrocution ou de brûlures. Pour réduire ces risques, respecter les précautions ci-dessous :! ATTENTION DANGERRisque de danger électrique et d’incendie. Danger de mort, de blessure grave, d’électrocution ou de brûlures. Pour réduire ces risques, respecter les précautions ci-dessous :· NE PAS MARCHER sur des zones mouillées du sous-sol sans que le courant n’ait été coupé. Si le panneau électrique principal se trouve dans un sous-sol mouillé, faire appel à un électricien.· DÉBRANCHER SYSTÉMATIQUEMENT la pompe de la prise de courant avant toute intervention ou réglage.· TOUJOURS DÉBRANCHER le boîtier régulateur et débrancher les câbles de la batterie avant une intervention d’entretien ou un nettoyage· NE JAMAIS TOUCHER la pompe ou le moteur avec des mains mouillées ou en se tenant sur une surface mouillée lorsque la pompe est branchée sur la source de courant.· S’ASSURER QU’UNE PRISE DE COURANT CORRECTEMENT MISE À LA TERRE EST DISPONIBLE. La pompe dispose d’une fiche à 3 broches avec mise à la terre. Pour réduire le risque d’électrocution, s’assurer qu’elle n’est branchée qu’à une prise à 3 trous correctement mise à la terre. Si vous ne disposez que d’une prise à 2 trous, la faire remplacer, par un électricien agréé, par une prise à 3 trous conforme à la réglementation en vigueur.

· NE JAMAIS neutraliser les fils de mise à la terre ni retirer de la fiche la broche de mise à la terre.· NE PAS utiliser de rallonge. La prise de courant devrait être de la même longueur que le cordon d’alimentation de la pompe et se trouver à au moins 1,20 m (4 pi) au-dessus du sol afin d’éviter tout risque en cas d’inondations.· N’UTILISEZ PAS une pièce d’accessoire non recommandée par le fabricant. Cela pourrait provoquer un risque d’incendie ou des blessures causées par une décharge électrique.· PROTÉGER le cordon d’alimentation contre les objets acérés, les surfaces chaudes, l’huile et les produits chimiques. Éviter d’emmêler le cordon.· S’ASSURER que le circuit d’alimentation est équipé d’un fusible ou d’un disjoncteur spécifique ayant une capacité suffisante pour la consommation indiquée sur la plaquette signalétique de la pompe.ATTENTIONPour réduire le risque de dangers susceptibles de causer des blessures ou des dégâts matériels, respecter les précautions ci-dessous :· NE PAS TRANSPORTER les pompes à l’aide de son cordon d’alimentation ou du serre-câble. Les porter avec la poignée.· NE PAS TIRER sur le cordon d’alimentation pour débrancher le système ou la pompe. Tirer sur la fiche.· NE PAS EXPOSER les régulateurs à l’eau, à la pluie ou à la neige. NE PLACEZ PAS les unités de commande sur le sol.· NE PAS FAIRE FONCTIONNER les pompes ou les régulateurs s’ils ont été endommagés de quelque manière que ce soit.· NE PAS UTILISER LES POMPES dans des fosses contenant des eaux usées, de l’eau salée ou des liquides dangereux. Ce produit est réservé à l’utilisation avec des eaux souterraines.· NE PAS DÉMONTER les pompes ni les régulateurs. En cas de nécessité d’une intervention, prendre contact avec le service technique de Glentronics au 800-991-0466 (option 3). Pour toute réparation, envoyer l’article au fabricant, à l’adresse ci-dessous : Glentronics, Inc. 645 Heathrow Drive, Lincolnshire, IL 60069PRÉPARATION DE LA BATTERIE! AVERTISSEMENT / POISONL’acide sulfurique contenu dans les batteries peut causer la cécité ou des brûlures graves. Éviter tout contact avec les yeux, la peau ou les vêtements. En cas d’accident, rincer à l’eau et appeler immédiatement un médecin. TENIR HORS DE PORTÉE DES ENFANTS.

Pour réduire ces risques, appliquer les précautions ci-dessous : · Lors d’une intervention à proximité d’unebatterie plomb-acide, quelqu’un doit être à portée de voix, ou suffisamment près pour se porter à votre aide. · Prévoir une grande quantité d’eau et du savon à proximité, au cas où de l’acide de la batterie entrerait en contact avec la peau, les vêtements ou les yeux. · Porter des lunettes et des vêtements protecteurs, et éviter de se toucher les yeux lors d’une intervention sur l’acide d’une batterie ou à proximité d’une batterie. · En cas de contact de la peau ou des vêtements avec l’acide de la batterie, laver immédiatement à l’eau et au savon. Si de l’acide pénètre dans l’oeil, rincer immédiatement celui-ci à grande eau pendant au moins 15 minutes, et consulter un médecin le plus rapidement possible.! AVERTISSEMENTS : Les bornes et les cosses de la batterie contiennent du plomb, seul ou en alliage, ou d’autres substances chimiques reconnus par l’État de la Californie comme étant cancérigènes et entraînant des anomalies congénitales ou d’autres effets nocifs sur l’appareil reproducteur. Se laver les mains après utilisation.Voir https://www.p65warnings.ca.gov/ pour plus d’information.! AVERTISSEMENTS : Le liquide de la batterie peut vous exposer à des produits chimiques, notamment à de fortes vapeurs d’acide non organique contenant de l’acide sulfurique, connu pour causer des cancers dans l’État de Californie. Pour toute information complémentaire, visitez la page www.P65warnings.ca.gov.PRÉCAUTIONS À PRENDRE VIS-À-VIS DE LA BATTERIE! ATTENTION DANGERLes gaz explosifs qu’elle émet risquent d’entraîner des blessures graves ou la mort. Dans un espace confiné, les cigarettes, les flammes ou les étincelles sont susceptibles de causer l’explosion d’une batterie. Ne charger la batterie que dans un local bien aéré. Toujours se protéger les yeux et le visage par rapport à une batterie. Maintenir les bouchons de mise à l’air libre bien serrés et horizontaux.Pour réduire ces risques, appliquer les précautions ci-dessous :· NE JAMAIS FUMER ni laisser une étincelle ou une flamme approcher de la batterie.· N’utiliser le régulateur Basement Watchdog que pour charger une batterie PLOMB-ACIDE. NE PAS RECHARGER à l’aide du régulateur des piles sèches comme celles qui se trouvent

couramment dans les appareils domestiques.· Veiller à la bonne aération de la zone dans laquelle se trouve la batterie.· Avant de nettoyer la batterie, ou d’y ajouter de l’eau, agiter au-dessus d’elle un morceau de carton ou de matériau non métallique pour éliminer l’hydrogène ou l’oxygène qui en émanerait.· NE PAS FAIRE TOMBER d’outils métalliques sur la batterie. Ceci risquerait de causer des étincelles, ou de mettre la batterie en courtcircuit, et de causer une explosion.· Retirer tous les objets personnels en métal (bagues, bracelets, montres, etc.) avant d’intervenir sur une batterie plomb-acide. Un court-circuit passant par un de ces objets risquerait de le faire fondre, causant ainsi une brûlure grave.· TOUJOURS DÉBRANCHER le chargeur de la prise de courant avant de brancher ou de débrancher les câbles de la batterie. Ne jamais laisser les cosses se toucher.· Vérifier la polarité des bornes de la batterie. La borne POSITIVE (+) est en général plus grosse que la borne NÉGATIVE (-).

La BORNE POSITIVE (+) a La BORNE NÉGATIVE (-) un diamètre plus grand a un diamètre plus petit· Lors du raccordement des câbles à la batterie, raccorder en premier la petite cosse (fil BLANC) à la borne NÉGATIVE (-) de la batterie, puis raccorder la grande cosse (fil NOIR) à la borne POSITIVE de la batterie.

BORNE POSITIVE(+)

BORNE NÉGATIVE(-)

· TOUJOURS fixer le couvercle du boîtier de batterie en enfonçant ses languettes dans leurslogements à l’avant et à l’arrière du boîtier.

! ATTENTION DANGERNe pas utiliser ce système pour le pompage de fluides inflammables ou explosifs (essence, mazout, kérosène, etc.)Page 16

PréambuleLe système combiné de pompes de puisard principale et de secours Basement Watchdog est conçu pour fonctionner comme pompe principale et de secours. La pompe principale fonctionne tant qu’elle est alimentée en courant de ligne. En cas de coupure de courant, ou d’arrivée dans le puisard d’eau en trop grande quantité pour la pompe principale, la pompe de secours se met en marche automatiquement. Le système de secours est muni d’un dispositif de surveillance exclusif qui diagnostique les problèmes et déclenche une alarme sonore. Un voyant situé sur la face avant du régulateur indiquera la cause de l’alarme et la mesure corrective à prendre. Les deux systèmes sont pré-assemblés, pour faciliter l’installation.Le système de pompes de puisard Basement Watchdog se compose de :· Une pompe principale de 1/3 HP déclenchée par un interrupteur à deux flotteurs et gérée par un régulateur bleu alimenté par une prise de courant· Une pompe de secours fixée sur un support · Un régulateur pour la pompe de secours,avec un capteur de niveau de fluide, un interrupteur à deux flotteurs et les câbles de la batterie · Une attache-câbles destinée à la fixation du régulateur jaune sur le tuyau d’évacuation · Deux attache-câbles destinées à la fixation des autres fils sur le tuyau d’évacuation · Un bouchon de batterie percé pour le passage du capteur de niveau de fluide · Un chargeur · Un raccord union en caoutchoucVous devrez également vous procurer :· Une batterie de secours Basement Watchdog « Standby », une batterie de secours Basement Watchdog « Big Standby » ou une batterie de secours Basement Watchdog « Standby » sans entretien (AGM). NE PAS UTILISER une batterie automobile avec ce système.· Six pintes d’acide pour batterie ayant une densité de 1,265 (dans le cas d’une batterie de secours plomb-acide « ouverte »)· Un boîtier de batterie avec un couvercle*La réalisation interne de certaines batteries à éléments humides risque de ne pas être compatible avec ce système. Glentronics ne peut pas garantir la compatibilité de batteries d’autres marques. L’emploi d’une batterie Basement Watchdog est FORTEMENT recommandé.Page 17

Pompe desecoursRégulateur de pompe de secoursChargeur de batterie

Interrupteur à flotteurs de pompede secours Interrupteur à flotteurs de pompe principale Pompe principaleRaccord union en caoutchouc

Câble de batterie

Capteur de niveau defluide

Bouchon de Batterie

Attache-câbles

Régulateur de pompe principale

Matériel éventuellement nécessaire : · Tube en PVC rigide de 1,5 po · Un raccord de tuyaux en PVC de 1,5 po ouun raccord union en caoutchouc de 1,5 po · Produit de nettoyage et de la colle pourtuyaux en PVC

Caractéristiques du systèmeAlimentation . . . . . . . . . . . .115 volts, 60 Hz Capacité de pompage CA . . . . . . . .11,735 l/h(3100 gal. US/h) à 2,7 m (10 pi) Capacité de pompage CC . . . . . . . . . .3800 l/h(1000 gal. US/h) à 2,7 m (10 pi) Overall dimensions . .254 mm (l) x 450 mm (h) Carter de pompe et crépine . . . . . . . . . . . . . . Primaire – Boîtier en fonte avec crépine non corrosive De secours – Boîtier et crépine non corrosifs

Installation de la canalisation

et de la pompe

Le système combiné de

pompes de puisard

principale et de secours

Basement Watchdog est

45 cm

compact; il tient dans un

puisard de 25 cm (10 po) de

diamètre et de 35 cm (14

po) de haut, soit la taille

d’un seau de 20 litres (5

gallons US). Il mesure 0,45 m (17,75 po) du bas de la

pompe au haut du raccord en Y au niveau duquel

s’effectue le raccordement au tuyau d’évacuation.

Se servir d’un puisard conforme à tous les codes locaux,

et vérifier dans le code l’éventuelle exigence d’un

robinet vanne ou à tournant sphérique.

Le cheminement du tuyau d’évacuation vertical vers un

mur extérieur doit être le plus court avec le moins de

coudes possible. Plus il y a de coudes, moins

l’évacuation est efficace.Le tuyau d’évacuation doit être

en pente vers le bas, de manière à ce que l’eau qui

pourrait y rester puisse s’écouler par gravité. À défaut,

l’eau qui aurait gelé dans la canalisation obturerait la

sortie de la pompe, ce qui l’endommagerait (voir le

schéma A).

SOLIVE

Schéma A

INCLINER LE TUYAU VERS LE BAS

RÉGULATEUR DE POMPE PRINCIPALE

RÉGULATEUR DE LA

PUSH

to Test

or Reset

POMPE DE SECOURS

PRISE DE COURANT CHARGEUR DE LA POMPE DE SECOURSFIL DE L’INTERRUPTEURÀ FLOTTEURS DE LA POMPE PRINCIPALEFIL DE LA POMPE PRINCIPALEATTACHE DE CÂBLES

FIL DE LA POMPE DE SECOURSFIL DE L’INTERRUPTEUR À FLOTTEURS DE LA POMPE DE SECOURS

RACCORD OU RACCORD UNION

CÂBLES DE LA BATTERIE

CAPTEUR DE NIVEAU DE FLUIDE

ATTACHE DE CÂBLES COUVERCLE DU PUISARDPOMPE DE SECOURS SUPPORT DE POMPEOU BRIQUES

BATTERIETUYAU DE DRAINAGE INTERRUPTEUR À FLOTTEURS DE POMPE DE SECOURS INTERRUPTEUR À FLOTTEURS DE POMPE PRINCIPALE POMPE PRINCIPALE

Le système doit être mis sur une surface plane exempte de saletés et de débris. Si le fond du puisard n’est pas propre, éliminer autant le maximum de débris possible. On pourra poser sur le fond du puisard un support ou des briques pour surélever la pompe au-dessus des débris.En cas de remplacement d’une pompe de puisard existante, débrancher celle-ci de la prise de courant.1. Retirer le clapet anti-retour ou le raccord union en caoutchouc. Si le système existant n’est pas équipé d’un clapet anti-retour ou d’un raccord union, découper le tuyau au-dessus du puisard comme l’indique l’étape 3 ci-dessous. Mettre au rebut le clapet anti-retour. Le système Basement Watchdog étant équipé de clapets anti-retour incorporés, l’ancien n’est pas nécessaire.2. Extraire la pompe à remplacer du puisard, et dévisser le tuyau (avec son adaptateur) de celle-ci.3. Mesurer la distance entre le fond du puisard ou le dessus des briques qui y sont posées et l’extrémité du tuyau d’évacuation. Soustraire 475 mm (18,75 po), soit la hauteur du système de pompes + 2,5 cm (1 po). Couper dans du tuyau en PVC rigide de 1,5 po un morceau de cette longueur.4. (a) Coller le morceau ainsi obtenu au tuyau d’évacuation avec un raccord en Y en PVC de 1,5 po. (Respecter le mode d’emploi du produit de nettoyage et de la colle pour PVC.) ou (b) Raccorder les deux tuyaux au moyen d’un raccord union en caoutchouc.5. Extraire l’ensemble des pompes pré-assemblées de son carton d’emballage à l’aide de la sangle située sur le dessous tout en soutenant le dessus de l’autre main. Mettre l’ensemble en position verticale sur le sol près du puisard. Inspecter visuellement la pompe. Les produits peuvent en effet avoir été endommagés pendant le transport. Si le produit a été endommagé, prendre contact avec le revendeur ou Glentronics avant l’installation.6. Retirer la sangle de la pompe.7. Extraire du carton les cordons et les régulateurs, et les poser à côté de l’ensemble de pompes. VEILLER À CE QUE NI LES CORDONS D’ALIMENTATION NI LES RÉGULATEURS NE TOMBENT DANS LE PUISARD PENDANT L’INSTALLATION.8. Desserrer les colliers du raccord union livré avec le système, et enfoncer celui-ci sur le tuyau d’évacuation jusqu’à ce qu’il soit au niveau du bas du tuyau.9. Soulever l’ensemble des pompes à l’aide de la poignée de la pompe principale, et mettre l’ensemble

dans le puisard. S’assurer qu’il est horizontal.10. Inspecter les deux interrupteurs à flotteurs. Ils doivent être verticaux, et placés de manière à se déplacer sans à-coup sans toucher ni les pompes ni la paroi du puisard.11. Mettre le haut du tuyau de l’ensemble de pompes directement en-dessous du tuyau d’évacuation. Faire descendre le raccord union jusqu’à ce qu’il couvre à moitié le tuyau venant de la pompe et à moitié le bas du tuyau d’évacuation. Bien serrer les vis des colliers.BOUT DU TUYAU

MESURER LA DISTANCE

TUYAU DE DRAINAGE

2

3

4a

5

7

8

9&10

1 4b11

Page 18

Préparation de la batterieLa batterie de secours « Emergency Standby » de Basement Watchdog a été conçue pour faire fonctionner ce système pendant 50 heures, sur la base d’un cycle de travail de 10 %. Toutefois, en général, la pompe ne fonctionne que par intermittence; dans ces conditions, la batterie peut l’alimenter pendant plusieurs jours. De plus, la composition interne de cette batterie lui procure une longévité supérieure en mode secours.Pour prolonger la durée de fonctionnement de la pompe, utilisez la batterie Big Standby de Basement Watchdog. Elle fera fonctionner cette pompe durant 100 heures, sur la base d’un cycle de travail de 10 %. Pourquoi fonctionnera-t-elle plus longtemps ? Parce que la batterie Big est accréditée pour d’autres pompes de Basement Watchdog demandant plus de puissance (amps). La pompe de secours consomme moins, et dure donc plus longtemps.NOTA : La batterie ne fait pas fonctionner lapompe principale.ATTENTION· L’emploi d’une batterie automobile est DÉCONSEILLÉ. Les batteries pour automobiles ne sont pas étudiées pour cette application. Elles ne permettent de faire fonctionner la pompe que moins longtemps, et ont une longévité inférieure à celle d’une batterie de secours.· Le capteur de niveau est conçu spécialement pour les batteries Basement Watchdog. La mesure du niveau du fluide de la batterie est l’une des caractéristiques les plus importantes du système; en effet, environ 80 % des défaillances de pompes de puisard de secours sont dues à l’asséchement de la batterie.· La réalisation interne de certaines batteries à éléments humides risque de ne pas être compatible avec ce système. L’emploi d’une batterie Basement Watchdog est FORTEMENT recommandé.! ATTENTION DANGERNE PAS mettre le capteur de niveau de fluide dans une batterie qui ne serait pas une batterie Basement Watchdog. NE PAS percer de trou dans une batterie d’une autre marque pour permettre le passage du capteur de niveau. NE PAS mettre le bouchon livré avec la batterie sur une autre batterie, sauf une batterie Basement Watchdog. NE PAS percer de trou dans un bouchon d’une batterie d’unePage 19

autre marque pour permettre le passage du capteur de niveau. Les batteries émettent des gaz explosifs, qui risquent de causer une blessure grave ou la mort.PRÉPARATION DE LA BATTERIE DE SECOURS BASEMENT WATCHDOGLes batteries Basement Watchdog sont livrées sèches (sans acide); elles ne perdent jamais de puissance avant d’être chez vous. Une batterie est activée au moment où on y verse de l’acide; à partir de ce moment, elle se détériore lentement avec l’âge. Le fait d’ajouter l’acide juste avant l’emploi assure une batterie fraîche. La batterie doit être remplie avec de l’acide pour batterie ayant une densité de 1,265. Elle est disponible là où vous avez acheté la batterie.NOTA : Deux modèles de batteries Basement Watchdog sont maintenant disponibles. Les dessus des batteries sont différents, et leur remplissage ainsi que le raccordement du capteur de niveau présentent quelques différences. Si le dessus de votre batterie ressemble à la photo A, suivre les instructions figurant sur cette page. Si le dessus de votre batterie ressemble à la photo B, page 9, suivre les instructions figurant page 5.! ATTENTION DANGER / POISONContient de l’acide sulfurique. Porter des lunettes et des vêtements de protection. En cas de contact de la peau ou des vêtements avec l’acide de la batterie, laver immédiatement à l’eau et au savon. Si de l’acide pénètre dans l’oeil, rincer immédiatement celui-ci à grande eau pendant 10 minutes, et consulter un médecin le plus rapidement possible. Consulter les instructions de sécurité page 1.1. Si vous n’avez pas acheté de boîtier pour la batterie, mettre un sac-poubelle en matière plastique, recouvert de serviettes en papier ou de papier-journal, sur le sol, pendant le remplissage de la batterie. Mettre la batterie sèche (non remplie d’acide) sur le papier. Après avoir acheté un boîtier de batterie, posez-le directement sur le sol et placez la batterie dedans. Gardez TOUJOURS le couvercle fixé sur le boîtier de batterie.2. Enlever la membrane fermant le dessus de la batterie.3. (a) Enfoncer avec précaution la languette perforée sur le dessus du récipient d’acide. Soulever la grande languette et extraire le tube verseur. Tout en maintenant le tube vertical au-dessus du récipient, appuyer sur le tube pour faire retomber l’acide dans le

BATTERIE Arécipient. (b) Disposer le récipient d’acide et la batterie comme indiqué ci-contre. Tout en pinçant le tube, couper son extrémité. Mettre l’extrémité du tube dans chaque élément. Le débit se gère en pinçant le tube avec le pouce et l’index. Remplir tous les éléments de la batterie de manière à recouvrir tout juste les plaques, puis faire l’appoint de chaque élément au niveau correct. Il est important que les éléments soient remplis de manière égale, faute de quoi la batterie ne fonctionnerait pas correctement. Le niveau d’acide doit être d’environ 4 mm (3/16 po) sous les bagues des bouchons (voir schéma B). Après le remplissage initial d’une batterie, un complément d’acide pourra être nécessaire après une dizaine de minutes. Revérifier le niveau, et rajouter de l’acide si nécessaire. S’il arrive que l’acide dans la batterie bouillonne avec une odeur soufré, c’est normal. Une fois la batterie remplie, visser fermement les bouchons des éléments. Entre 15 et 30 minutes après avoir été remplie d’acide, la batterie aura atteint 70 à 80 % de sa charge. Le système finira de la charger. Pendant ce temps, il se peut que l’alarme retentisse. C’est normal.BOBRANTETSERDYE LTAERBMATINTEARLISEBBAGATUTEEDREYSCBAOPURCHINOGNSSSECTIONCTRRAONSSVSERSSEACLETIDOE NLAOBFATBTAERTITE ERY

123a3b Schéma B22endNILVEEVAEUL N1IsVtELAEUVEDLE REMPLISSAGE PPLLAAQTEUSES PLC’AÉERLLÉOLMIWEDNAETLL

1. Premier niveau de remplissage : recouvrir les plaques.2. Ensuite, ajouter de l’acide pour atteindre le 2e niveau, juste endessous des bagues des bouchons.Ne pas mettre une batterie usagée à la poubelle. L’apporter à une station-service ou à un centre de recyclage.

Retirer le papier et le sac-poubelle de sous la batterie. L’enrouler avec le plastique à l’extérieur et le rebuter.BATTERIE BSi votre batterie ressemble à celle représentée ci-dessus, suivre ces instructions : 1. Si vous n’avez pas acheté de boîtier pour labatterie, mettre un sac-poubelle en matière plastique, recouvert de serviettes en papier ou de papier-journal, sur le sol, pendant le remplissage de la batterie. Mettre la batterie sèche (non remplie d’acide) sur le papier. Après avoir acheté un boîtier de batterie, posez-le directement sur le sol et placez la batterie dedans. Gardez TOUJOURS le couvercle fixé sur le boîtier de batterie. 2. Retirer les deux bouchons en faisant levier (avec précaution) à l’aide d’un tournevis. Mettre le tournevis dans la rainure au milieu du bouchon sur le dessus de la batterie. NE PAS SOULEVER le bouchon en faisant levier sous la rainure du côté de la batterie. Ceci risquerait d’endommager la mise à l’air libre. 3. (a) Enfoncer avec précaution la languette perforée sur le dessus du récipient d’acide. Soulever la grande languette et extraire le tube verseur. Tout en maintenant le tube1

vertical au-dessus du récipient, appuyer sur le tube pour faire retomber l’acide dans le récipient. (b) Disposer le récipient d’acide et la batterie comme indiqué ci-dessous. Tout en pinçant le tube, couper son extrémité. Mettre l’extrémité du tube dans chaque élément. Le débit se gère en pinçant le tube avec le pouce et l’index. Remplir tous les éléments de la batterie de manière à recouvrir tout juste les plaques, puis faire l’appoint de chaque élément au niveau correct. Il est important que les éléments soient remplis de manière égale, faute de quoi la batterie ne fonctionnerait pas correctement. Le niveau d’acide doit être d’environ 6 mm (0,25 po) sous les bagues des bouchons (voir schéma B). Après le remplissage initial d’une batterie, un complément d’acide pourra être nécessaire après une dizaine de minutes. Revérifier le niveau, et rajouter de l’acide si nécessaire. S’il arrive que l’acide dans la batterie bouillonne avec une odeur soufré, c’est normal. Une fois la batterie remplie, enfoncer fermement les deux bouchons sur le dessus de la batterie. Entre 15 et 30 minutes après avoir été remplie d’acide, la batterie aura atteint 70 à 80% de sa charge. Le système finira de la charger. Pendant ce temps, il se peut que l’alarme retentisse. C’est normal. Retirer le papier et le sac-poubelle de sous la batterie. L’enrouler avec le plastique à l’extérieur et le rebuter.ATTENTIONLe REMPLISSAGE INITIAL de la batterie est le SEUL à l’occasion duquel on y met de l’acide. Par la suite, pour rétablir le niveau, il faut ajouter de l’eau distillée. NE JAMAIS RAJOUTER d’acide.3a

Entretien de la batterieLa mesure du niveau du fluide de la batterie est l’une des caractéristiques les plus importantes du système. Il est important de vérifier le niveau du liquide dans la batterie au minimum tous les 4-6 mois. On trouvera des instructions détaillées expliquant comment faire l’appoint en eau distillée dans la batterie au chapitre Explication des consignes de sécurité et des alarmes (page 22,2 Water (eau). Si la batterie utilisée n’est pasune batterie de secours Basement Watchdog, le capteur de niveau est inutilisable. Le capteur doit être raccordé à la borne POSITIVE (+) de la batterie, faute de quoi l’alarme retentirait en permanence. L’alarme de niveau insuffisant de fluide NE FONCTIONNE PAS dans cette configuration. Il sera nécessaire de vérifier la batterie tous les deux mois pour voir s’il est nécessaire d’y ajouter de l’eau. Si la batterie s’assèche, le système ne fonctionnera pas. Dans le cas d’une batterie sans entretien ou d’une batterie étanche de type « AGM », le capteur doit être raccordé à la borne POSITIVE (+) de la batterie, faute de quoi l’alarme retentirait en permanence.Raccordements du système! ATTENTION DANGERRisque d’électrocution ou d’explosion de la batterie, pouvant causer une blessure grave ou la mort. Débrancher la pompe principale pour éviter une électrocution. Porter des lunettes protectrices. Ne travailler que dans un local bien aéré. Ne pas fumer ni laisser une étincelle ou une flamme approcher de la batterie. Éviter de laisser tomber des outils en métal sur la batterie. Si de l’acide de la batterie pénètre dans l’oeil, rincer immédiatement celui-ci à grande eau pendant 15 minutes, et consulter un médecin le plus rapidement possible. Consulter les instructions de sécurité page 1.

Schéma C

PRISE DE COURANT

SOLIVE RÉGULATEUR DE POMPE PRINCIPALEPUSH to Test or Reset

INCLINER LE TUYAU VERS LE BASRÉGULATEUR DE LA POMPE DE SECOURS

CHARGEUR DE LA POMPE DE SECOURSFIL DE L’INTERRUPTEURÀ FLOTTEURS DE LA POMPE PRINCIPALEFIL DE LA POMPE PRINCIPALEATTACHE DE CÂBLES

FIL DE LA POMPE DE SECOURSFIL DE L’INTERRUPTEUR À FLOTTEURS DE LA POMPE DE SECOURS

CÂBLES DE LA BATTERIE

CAPTEUR DE NIVEAU DE FLUIDE

ATTACHE DE CÂBLES COUVERCLE DU PUISARD

BATTERIE

POMPE DE SECOURS SUPPORT DE POMPE OU BRIQUES

TUYAU DE DRAINAGEINTERRUPTEUR À FLOTTEURS DE POMPE DE SECOURS INTERRUPTEUR À FLOTTEURS DE POMPE PRINCIPALE POMPE PRINCIPALE

MONTAGE DU RÉGULATEURLors de la mise en place du régulateur de la pompe de secours sur le tuyau d’évacuation, veiller à ce que le cordon du chargeur atteigne la prise de courant, et à ce que le câble de la pompe et l’interrupteur à flotteurs atteignent le fond du puisard. Mettre la pompe dans une zone bien aérée. Ne rien mettre sur la batterie (schéma C).1. Montage du régulateur de secours : (a) Passer une attache-câbles dans les deux supports à l’arrière du régulateur. (b) Fixer le régulateur au tuyau de refoulement de la pompe en serrant bien l’attache en plastique sur le tuyau.

2

3b

1a

1b

2

Page 20

2. Raccordement de la pompe de secours : Retirer le bouchon de sécurité de la pompe et brancher les fils dans le connecteur de pompe à l’arrière du régulateur.3. Installation du capteur de niveau de fluide de la batterie : Retirer le couvercle du boîtier de batterie et agiter un morceau de carton (ou d’un matériau non métallique) au-dessus de la batterie pour éliminer hydrogène ou l’oxygène qui en émanerait. (a) Si vous avez une batterie de type « A », remplacer le 2e bouchon à partir de la borne POSITIVE (+) par celui livré avec le système Basement Watchdog. Cet emplacement est repéré par une flèche sur le dessus de la batterie. Le bouchon est muni de 2 trous. Enfoncer le capteur de niveau dans le trou excentré du bouchon. Ne pas coller le capteur dans le bouchon. (b) Si votre batterie est du type « B », son dessus dispose d’un trou prévu pour la tige du capteur de niveau. Le trou pour le capteur est repéré par un marquage sur le dessus de la batterie. Enfoncer fermement le capteur dans le trou en le tenant bien vertical, jusqu’à la base du connecteur. Ne pas tordre la tige du capteur.Si la batterie utilisée n’est pas une batterie de secours Basement Watchdog, le capteur de3a

3b

POSITIVE 4 POSTPage 21

NEGATIVE POST

niveau est inutilisable. En tout état de cause, il faut obligatoirement raccorder le capteur à la borne POSITIVE (+) de la batterie, faute de quoi l’alarme retentirait en permanence. L’alarme de niveau de fluide insuffisant du système de pompe de puisard Basement Watchdog ne fonctionne pas dans cette configuration. Il sera nécessaire de vérifier la batterie tous les deux mois pour voir s’il est nécessaire d’y ajouter de l’eau. Si la batterie s’assèche, le système ne fonctionnera pas. Si vous utilisez une batterie sans entretien ou une batterie hermétique AGM, vous devrez aussi fixer le capteur de fluide à la borne POSITIVE (+) de la batterie, sinon l’alerte retentira de manière continue. 4. Raccordement de la batterie : Enlever lesécrous papillons des bornes. Enleverl’étiquette de sécurité des câbles de labatterie. Fixer les câbles à la batterie : leBLANC se branche sur la borne NÉGATIVE (-) etle NOIR sur la borne POSITIVE (+). Remettreles écrous papillons et les serrer. Nota : Si lescâbles sont branchés sur les mauvaisesbornes, ceci endommagera le régulateur. 5. Raccordement du chargeur : Brancherimmédiatement le chargeur dans sonconnecteur à l’arrière du régulateur et dansune prise de courant.6. Si l’alarme de la pompe retentit, appuyer surle bouton ROUGE pour l’arrêter.7. Remettre le couvercle du boîtier de batterieen place. 8. Raccordement de la pompe principale :Brancher le régulateur dans une prise decourant à 3 trous correctement mise à la terre.Ensuite, brancher la pompe principale dans laprise du régulateur.9. Pour une installation encore plus soignée,fixer les câbles allant aux régulateurs sur letuyau d’évacuation à deux points avec lesattache-câbles supplémentaires. S’assurerque les fils ne se touchent pas ou ne sechevauchent pas.10. Après la première installation, assurez-vousde vérifier le fonctionnement de la pompe enremplissant le puisard avec de l’eau et enobservant plusieurs cycles de la pompe.Quand l’interrupteur à deux flotteurs estbranché, la pompe principale doitnormalement continuer à fonctionner

5a

5b

6

8

9

pendant 10 secondes après que le flotteur inférieur soit redescendu. 11. Après la première installation, assurez-vous de vérifier le bon fonctionnement de chaque pompe. Pour vérifier la pompe primaire, remplissez le puisard d’eau et faites passer la pompe par plusieurs cycles complets. Elle doit fonctionner pendant 10 secondes après que le flotteur inférieur soit tombé. Pour vérifier le fonctionnement de la pompe de secours, levez manuellement le flotteur de secours, puis laissez-le descendre. La pompe de secours fonctionnera pendant environ 45 secondes. Une fois la pompe de secours arrêtée, appuyez sur le bouton ROUGE.FonctionnementL’interrupteur à deux flotteurs de la pompe principale contient deux grosses bagues flottantes protégées par une cage. Il faut que l’eau soulève le flotteur inférieur de 6 mm (¼ po) pour déclencher la pompe. Si, pour quelque raison que ce soit, le flotteur du bas ne déclenche pas la pompe, la montée de l’eau actionne l’autre interrupteur qui déclenche le fonctionnement de la pompe. Au fur et à mesure que la pompe évacue l’eau de la fosse, les

flotteurs redescendent. La pompe continue de fonctionner pendant 10 secondes après que le flotteur du bas soit redescendu. C’est le régulateur bleu de la pompe principale qui alimente cet interrupteur.Pendant une coupure de courant, ou si l’eau pénètre trop vite dans le puisard pour pouvoir être évacué par la pompe, la pompe de secours se met en marche automatiquement. Elle est également munie d’un interrupteur à deux flotteurs, dont l’un déclenche le fonctionnement de la pompe quand l’eau atteint ce niveau si l’autre flotteur ne le fait pas. Quand le niveau de l’eau redescend en-dessous du flotteur, un minuterie intégrée au régulateur maintient la pompe en fonctionnement pendant 25 secondes supplémentaires pour vider le puisard. Le câble de l’interrupteur à flotteur de secours comporte un connecteur qui peut être détaché du contrôleur lorsque le câble doit être introduit dans de petites ouvertures, comme un couvercle de puisard. Assurez-vous que le raccordement du câble de l’interrupteur à flotteur est solidement fixé avant l’installation finale. Pendant que les pompes fonctionnent, l’eau sortira par le trou de 1/8 po (3,1 mm) situé sur le dessus de la pompe principale, et par le trou de 3/16 po (4,7 mm) situé dans le coude de la pompe de secours. C’est normal. Ces trous sont destinés à empêcher une poche d’air dans le circuit. Ces trous NE DOIVENT PAS ÊTRE OBSTRUÉS, ce qui causerait alors une poche d’air empêchant le fonctionnement du circuit.Tant les batteries que les pompes nécessitent un entretien. Le régulateur du système de secours surveille la batterie et l’état de l’alimentation; il déclenche une alarme sonore quand une intervention est nécessaire. On trouvera ci-dessous une explication des alertes et des alarmes.

Explication des consignes de sécurité et des alarmesLe régulateur Basement Watchdog est équipé de voyants destinés à indiquer les problèmes. En plus, une alarme retentit pour vous prévenir du problème. Dans certains cas, les voyants et l’alarme s’arrêtent automatiquement quand le problème est réglé. Dans d’autres cas, il faut appuyer sur le bouton ROUGE pour arrêter l’alarme. Le tableau de la page 7 indique les différentes fonctions et le statut de l’alarme correspondante.

· 1 · 2 · 3 · 4 ·5

Voyant

Il est possible L’alarme s’arrête

d’arrêter automatiquement

l’alarme avant quand le

de corriger le problème est

problème

corrigé

Power

Oui

(alimentation)

Water

Non

(eau)

Pump

Yes

(pompe)

System Pas d’alarme (système)

Battery

Non

(batterie)

OuiOuiNon, appuyer sur le bouton ROUGEPas d’alarmeOui

ARRÊT DE L’ALARME PENDANT UNE ALERTE

Le système de pompes de puisard de secours Basement Watchdog est équipé d’un interrupteur destiné à arrêter une

alarme sonore pendant une alerte prolongée. Il est possible d’arrêter les alarmes « POWER » (alimentation) et « PUMP » (pompe) en cas de panne de courant, ou de fortes pluies qui déclencheraient des fonctionnements à répétition de la pompe.Pour arrêter les alarmes « POWER » et « PUMP », mettre l’interrupteur « Audible Alarm » sur la position « OFF » (arrêt). Les voyants «POWER» et «PUMP» restent allumés, mais l’alarme cesse de retentir.Une fois l’urgence terminée, remettre l’interrupteur sur la position « ON » (marche) pour rétablir la surveillance, à défaut de quoi vous ne seriez pas prévenu de l’urgence suivanteIl n’est pas possible d’arrêter les alarmes « WATER » (eau) et « BATTERY » (batterie). Ces deux alarmes nécessitent une intervention immédiate.1 Power (alimentation)Une absence de courant peut avoir plusieurs causes. La plus courante est une panne de courant au niveau de votre fournisseur d’électricité. Dans ce type d’urgence, le système Basement Watchdog bascule automatiquement sur l’alimentation par batterie pour protéger votre sous-sol de l’inondation. On peut arrêter l’alarme « Power » en mettant l’interrupteur « Audible Alarm » sur « OFF » (arrêt). L’alarme s’arrête, mais le voyant reste allumé. Le système continue de fonctionner avec l’alarme arrêtée. Veiller à remettre l’interrupteur sur la position « ON » (marche) au retour du courant pour rétablir la surveillance. 1. S’il y a du courant dans le reste du bâtiment,vérifier le disjoncteur ou la boîte à fusibles du bâtiment, et corriger le problème.2. Vérifier le chargeur. S’assurer qu’il est bien branché dans la prise de courant. S’assurer que la prise fonctionne correctement.3. Vérifier la fiche du chargeur qui se branche à

2

3

l’arrière du régulateur. S’assurer qu’elle est bien branchée dans le régulateur.Le régulateur doit obligatoirement être alimenté par une prise de courant 115 V CA +/- 5%. Une tension inférieure à 110 V déclenche l`alarme « POWER ». Une sous-tension peut être causée par une baisse de tension au niveau de la compagnie d’électricité, ou par une forte consommation d’autres appareils branchés sur le même circuit. Diminuer le nombre d’appareils branchés sur le circuit.Si toutes les connexions sont bonnes, ainsi que la prise de courant, et que le voyant « POWER » reste allumé, remplacer le chargeur par la référence 1015003 de Basement Watchdog. Communiquer avec Glentronics au 800-9910466, option 3.2 Water (eau)! ATTENTION DANGERRisque d’électrocution ou d’explosion de la batterie, pouvant causer une blessure grave ou la mort. Porter des lunettes protectrices. Ne travailler que dans un local bien aéré. Ne pas fumer ni laisser une étincelle ou une flamme approcher de la batterie. Éviter de laisser tomber des outils en métal sur la batterie. Si de l’acide de la batterie pénètre dans l’oeil, rincer immédiatement celui-ci à grande eau pendant 15 minutes, et consulter un médecin le plus rapidement possible. Consulter les instructions de sécurité page 1.Si ce voyant est allumé et que l’alarme retentit, il faut ajouter de l’eau distillée à la batterie (il n’est pas possible d’arrêter cette alarme; une fois le niveau de la batterie rétabli et le capteur remis en place, l’alarme s’arrête toute seule). Pour remplir la batterie :1. Débrancher le chargeur et le régulateur bleu de la pompe principale de la prise de courant.2. Retirez le couvercle du boîtier de la batterie et ventilez la zone autour du haut de la batterie avec un morceau de carton (ou d’un matériau non métallique) au-dessus de la batterie pour éliminer hydrogène ou l’oxygène qui en émanerait.3. Desserrer les écrous papillons et débrancher de la batterie les câbles et le capteur de niveau.4. Enlever les bouchons de la batterie. Ajouter de l’eau distillée dans chaque élément. À défaut d’eau distillée, de l’eau du robinet ayant une faible teneur en minéraux pourra

2

3

Retirer

4être utilisée. Il est déconseillé d’utiliser de l’eau provenant d’un puits. NE JAMAIS AJOUTER D’ACIDE. Remplir la batterie au niveau 2 indiqué par le schéma B de la page 4 (un dispositif de remplissage Basement Watchdog rétablit le niveau à sa hauteur correcte; voir le formulaire de commande ci-après).5. À l’aide d’un papier absorbant, nettoyer l’intérieur du bouchon de la batterie dans lequel se trouve le capteur de niveau. Remettre en place les bouchons de la batterie et le capteur de niveau. Veiller à ce que le capteur de fluide soit bien mis dans le 2e élément à partir de la borne positive. Selon le type de votre batterie, le capteur se met soit dans un bouchon ou dans le trou venu de moulage du dessus de la batterie. L’emplacement est repéré par une flèche sur le dessus de la batterie. Une fois le niveau de la batterie rétabli et le capteur remis en place, le voyant et l’alarme s’arrêtent automatiquement.6. Remettre les câbles de la batterie : le BLANC se branche sur la borne NÉGATIVE (-) et lePage 22

55NOIR sur la borne POSITIVE (+). Remettre les écrous papillons et les serrer. 7. Remettre le couvercle du boîtier de batterie en place. 8. Rebrancher le chargeur et le régulateu bleu dans la prise de courant.3 Pump (pompe)En cas de montée de l’eau dans le puisard, celleci déclenche l’interrupteur à flotteurs, ce qui met la pompe en marche, allume le voyant « PUMP » et déclenche l’alarme. L’alarme retentit pour indiquer que le système de secours a été déclenché afin d’évacuer de l’eau du puisard. Essayer de déterminer ce qui a causé la mise en fonctionnement du système. · Vérifier que la pompe principale n’est pas enpanne. Il se peut qu’elle ne fonctionne pas, que son interrupteur à flotteur soit bloqué, ou que sa capacité soit insuffisante. · S’assurer du bon fonctionnement et de la bonne installation des clapets anti-retour. Il est possible qu’il soit nécessaire de les remplacer (voir l’emplacement des clapets anti-retour page 12). · S’assurer que le tuyau de refoulement n’est ni obstrué ni gelé. · En cas de panne de courant, la pompe de secours se met en marche automatiquement. Il faut appuyer sur le bouton ROUGE du panneau de commande pour réarmer l’alarme. Pendant une panne de courant, ou quand la pompe se déclenche fréquemment, on peutPage 23

arrêter l’alarme provisoirement en mettant l’interrupteur « Audible Alarm » sur « OFF ». Après le retour en service de la pompe principale, et la fin des déclenchements à répétition de la pompe de secours, remettre l’interrupteur sur la position « ON » pour rétablir la surveillance. Le voyant d’alarme et le voyant « PUMP » restent allumés. Appuyer sur le bouton ROUGE du panneau de commande pour arrêter l’alarme.REMPLACEMENT DE LA POMPE DE SECOURSAvant d’entreprendre ce remplacement, une pompe de secours neuve est nécessaire. Il peut également être prudent de profiter de l’opération pour remplacer les clapets anti-retour. La pompe de secours fait appel à un clapet anti-retour de 1,25 po, alors que la pompe principale fait appel à un clapet anti-retour de 1,5 po. (voir la liste des pièces détachées page 28).! ATTENTION DANGER Risque d’électrocution ou d’explosion de la batterie, pouvant causer une blessure grave ou la mort. Porter des lunettes protectrices. Ne travailler que dans un local bien aéré. Ne pas fumer ni laisser une étincelle ou une flamme approcher de la batterie. Éviter de laisser tomber des outils en métal sur la batterie. Consulter les instructions de sécurité page 15.

IL FAUT DÉBRANCHER TOUS LES FILS. VEILLER À CE QU’ILS NE TOMBENT PAS DANS LE PUISARD. VOIR LES DESCRIPTIONS DES PIÈCES SUR LE SCHÉMA PAGE 12.1. Débrancher la pompe principale du régulateur bleu.2. Débrancher la fiche du chargeur de l’arrière du régulateur de secours.3. Débrancher la pompe de secours de l’arrière du régulateur de secours.4. Retirer le couvercle du boîtier de batterie en le soulevant après avoir appuyé sur les languettes situées à l’avant et à l’arrière. Agiter un morceau de carton (ou d’un matériau non métallique) au-dessus de la batterie pour éliminer hydrogène ou l’oxygène

1

2,3

7

8

10

11

qui en émanerait. 5. Retirer le capteur de la batterie. 6. Débrancher les câbles des bornes de labatterie. Veiller à ce qu’ils ne se touchent pas pendant que l’un d’entre eux est encore branché à une borne. 7. Desserrer lentement le raccord union en haut de l’ensemble de pompes pour séparer les tuyaux. L’eau restant dans le tuyau va couler dans le puisard quand le raccord sera desserré. 8. Séparer l’ensemble pompes du raccord union, et l’extraire du puisard à l’aide de la poignée de la pompe principale. 9. Retourner l’ensemble au-dessus du puisard pour y vidanger l’eau restant dans le système. 10. Desserrer les vis du manchon flexible sur leRetirer 5,6912

coude de la pompe de secours.11. Dévisser à l’aide d’un tournevis Phillips la vis en bas du support de pompe, et extraire la pompe de celui-ci. Ensuite, tirer la pompe vers le bas pour la désolidariser du manchon flexible.12. Dévisser le clapet anti-retour du coude de la pompe de secours. Ensuite, procéder en sens inverse.13. Visser le clapet anti-retour sur la pompe neuve (on peut prendre le clapet existant ou, de préférence, le remplacer par un neuf).14. Il faut impérativement percer un trou de 3/16 po (4,7 mm) dans le coude de la pompe neuve pour empêcher une poche d’air. Une poche d’air désamorcerait le circuit, empêchant son fonctionnement. Percer le trou, axé vers le bas, en-dessous du clapet anti-retour sur le coude.15. Remettre la pompe et le clapet anti-retour dans le manchon flexible, et remettre la pompe sur son support.16. Visser la pompe au support.17. Serrer le collier du manchon flexible.18. Remettre l’ensemble pompes dans le puisard.19. Raccorder le tuyau de sortie de l’ensemble au raccord union et serrer le collier.20. Brancher les câbles aux bornes de la batterie : le BLANC se branche sur la borne NÉGATIVE (-) et le NOIR sur la borne POSITIVE (+).21. Remettre en place le capteur de niveau du fluide dans le dessus de la batterie et remettre le couvercle du boîtier de batterie en place.22. Brancher la pompe de secours à l’arrière du régulateur de secours.23. Brancher la fiche du chargeur à l’arrière du régulateur de secours.24. Brancher la pompe principale dans le régulateur bleu.REMPLACEMENT DE LA POMPE PRINCIPALEAvant d’entreprendre ce remplacement, une pompe C.A. neuve est nécessaire. Il peut également être prudent de profiter de l’opération

pour remplacer les clapets anti-retour. La pompe de secours fait appel à un clapet anti-retour de 1,25 po, alors que la pompe principale fait appel à un clapet anti-retour de 1,5 po. (voir la liste des pièces détachées page 28).! ATTENTION DANGERRisque d’électrocution ou d’explosion de la batterie, pouvant causer une blessure grave ou la mort. Porter des lunettes protectrices. Ne travailler que dans un local bien aéré. Ne pas fumer ni laisser une étincelle ou une flamme approcher de la batterie. Éviter de laisser tomber des outils en métal sur la batterie. Consulter les instructions de sécurité page 1.IL FAUT DÉBRANCHER TOUS LES FILS. VEILLER À CE QU’ILS NE TOMBENT PAS DANS LE PUISARD. VOIR LES DESCRIPTIONS DES PIÈCES SUR LE SCHÉMA PAGE 12.1. Débrancher la pompe principale du régulateur bleu.2. Débrancher la fiche du chargeur de l’arrière du régulateur de secours.3. Débrancher la pompe de secours de l’arrière du régulateur de secours.4. Retirer le couvercle du boîtier de batterie en le soulevant après avoir appuyé sur les languettes situées à l’avant et à l’arrière. Agiter un morceau de carton (ou d’un matériau non métallique) au-dessus de la batterie pour éliminer hydrogène ou l’oxygène qui en émanerait.5. Retirer le capteur de la batterie.6. Débrancher les câbles des bornes de la batterie. Veiller à ce qu’ils ne se touchent pas pendant que l’un d’entre eux est encore branché à une borne.7. Desserrer lentement le raccord union en haut de l’ensemble de pompes pour séparer les tuyaux. L’eau restant dans le tuyau va couler dans le puisard quand le raccord sera desserré.8. Séparer l’ensemble pompes du raccord union, et l’extraire du puisard à l’aide de la poignée de la pompe principale.9. Retourner l’ensemble au-dessus du puisard pour y vidanger l’eau restant dans le système.10. Desserrer le collier de l’interrupteur à flotteurs, et le retirer.11. Couper les attache-câbles de l’interrupteur à

flotteurs de la pompe de secours, et le retirer.12. Desserrer le collier supérieur du manchon flexible monté sur la pompe principale.13. Desserrer le collier supérieur du manchon flexible monté sur la pompe de secours.14. Retirer le raccord en Y.15. Dévisser le clapet anti-retour de la pompe principale.16. Extraire avec précaution la pompe de secours et son support de la poignée de la pompe principale. Ensuite, procéder en sens inverse.17. Mettre avec précaution la pompe de secours et son support sur la poignée de la pompe principale neuve.18. Visser le clapet anti-retour en haut de la pompe principale. (On peut prendre le clapet existant ou, de préférence, le remplacer par

un neuf.)19. Raccorder le raccord en Y en haut du clapet anti-retour à l’aide du manchon flexible, et serrer le collier.20. Raccorder la pompe de secours à l’autre branche du raccord en Y au moyen de l’autre manchon flexible.21. Remettre l’interrupteur à flotteurs en place et serrer son collier.22. Remettre l’interrupteur à flotteurs de la pompe de secours en place et le fixer à l’aide de 2 attache-câbles neuves. S’assurer que les flotteurs se déplacement facilement et ne risquent pas d’être coincés contre la pompe.23. Remettre l’ensemble pompes dans le puisard en le tenant par la poignée de la pompe principale.

1

2,3

Retirer 5,6

7

8

9

10,11 Faire glisservers l’extérieur

12,13

15

16 Page 24

24. Raccorder le tuyau de sortie de l’ensemble au raccord union et serrer le collier.25. Brancher les câbles aux bornes de la batterie : le BLANC se branche sur la borne NÉGATIVE (-) et le NOIR sur la borne POSITIVE (+).26. Remettre en place le capteur de niveau du fluide dans le dessus de la batterie et remettre le couvercle du boîtier de batterie en place.27. Brancher la pompe de secours à l’arrière du régulateur de secours.28. Brancher la fiche du chargeur à l’arrière du régulateur de secours.29. Brancher la pompe principale dans le régulateur bleu.4 System (système)Ce voyant vert doit clignoter en permanence. Il indique que le système est en fonctionnement et que la batterie est branchée. Si ce voyant est éteint : · Vérifier le chargeur. S’assurer qu’il est bienbranché dans la prise de courant. · Vérifier la fiche du chargeur qui se branche àl’arrière du régulateur. S’assurer qu’elle est bien branchée dans le régulateur. · Si toutes les connexions sont bonnes et que la prise de courant est en ordre de marche, mais que le voyant « POWER » clignote, remplacer le chargeur. Téléphoner au service pièces de rechange de Glentronics au 800-991-0466 (option 3).5 Battery (batterie)Ce voyant s’allume et l’alarme retentit quand le régulateur détecte qu’il ne reste de courant que pour 1/2 heure de fonctionnement dans laPage 25

batterie. Il n’est pas possible d’arrêter cette alarme. Elle indique que la batterie est déchargée, ou défectueuses, et qu’une action immédiate est nécessaire pour la remplacer ou nettoyer ses bornes. L’alarme retentit quand : · De la corrosion sur les bornes de la batterie et(ou) des cosses des câbles gêne la charge de la batterie. · La batterie a vieilli et doit être remplacée. · La pompe a fonctionné pendant plusieurs heures, et la batterie est déchargée.Vérifier l’absence de corrosion au niveau des câbles et des bornes de la batterie. Les nettoyer et les serrer, le cas échéant. La marche à suivre est décrite page suivante.Si l’alarme de batterie retentit pendant que la pompe est en fonctionnement et qu’il n’y a pas de courant, il reste au minimum 1/2 heure de durée de pompage pour remplacer la batterie. (Dans la plupart des cas, la pompe ne fonctionne pas de manière ininterrompue et, en pratique, on a davantage de temps pour la remplacer.) Il n’est pas possible d’arrêter cette alarme. À défaut d’intervention, le sous-sol sera inondé. En cas d’urgence grave, si aucune batterie de rechange n’est disponible, on pourra se servir provisoirement d’une batterie de voiture.Une fois le courant rétabli, la batterie se rechargera automatiquement, sauf si elle est trop vieille ou en mauvais état. L’alarme s’arrête au retour du courant et quand l’énergie disponible dans la batterie atteint ou dépasse 1/2 heure.S’il arrivait que votre pompe de puisard de secours Basement Watchdog fonctionne pendant une durée prolongée, la batterie pourra être très déchargée. Dans ce cas, au retour du courant de ligne, l’alarme de batterie continuera de retentir. La recharge de la batterie pourra nécessiter davantage de temps.Pour accélérer la recharge, un chargeur pour automobile ou pour bateau pourra servir à recharger la batterie. Respecter les instructions du fabricant et les consignes de sécurité du chargeur. Assurez-vous que l’unité de commande de sauvegarde est déconnectée de la batterie.Si la batterie est relativement neuve et que l’alarme de batterie retentit, téléphoner au service entretien de Glentronics avant de remplacer la batterie. Numéro de téléphone : 800-991-0466 (option 3).

NETTOYAGE DES BORNES DE LA BATTERIE! ATTENTION DANGERRisque d’électrocution ou d’explosion de la batterie, pouvant causer une blessure grave ou la mort. Porter des lunettes protectrices. Ne travailler que dans un local bien aéré. Ne pas fumer ni laisser une étincelle ou une flamme approcher de la batterie. Éviter de laisser tomber des outils en métal sur la batterie. Si de l’acide de la batterie pénètre dans l’oeil, rincer immédiatement celui-ci à grande eau pendant 15 minutes, et consulter un médecin le plus rapidement possible. Consulter les instructions de sécurité page 1.1. Débrancher de la prise de courant le chargeur et le régulateur bleu.2. Retirer le couvercle du boîtier de batterie en le soulevant après avoir appuyé sur les languettes situées à l’avant et à l’arrière.3. Agiter un morceau de carton (ou d’un matériau non métallique) au-dessus de la batterie pour éliminer hydrogène ou l’oxygène qui en émanerait.4. Retirer le capteur de niveau de fluide de la

2

3

4

Retirer

5 6

7

8

9

batterie. Desserrer les écrous papillons. Enlever les câbles de la batterie.5. Nettoyer les bornes avec un outil de nettoyage de bornes ou une brosse métallique.6. Éliminer la corrosion éventuelle des cosses rondes aux extrémités des câbles de la batterie. Les nettoyer avec une brosse dure ou du papier abrasif. NE PAS pulvériser de produit ni mettre de rondelles anticorrosion sur les cosses ou les borne après les avoir nettoyées, ceci risquant d’empêcher la charge correcte de la batterie.7. Remettre le capteur de niveau du fluide de la batterie. Remettre les câbles de la batterie : le BLANC se branche sur la borne NÉGATIVE (-) et le NOIR sur la borne POSITIVE (+). Serrer les

écrous papillons et remettre le couvercle du boîtier de la batterie en place. 8. Brancher le chargeur et le régulateur bleu de la pompe C.A. dans la prise de courant. 9. Il pourra être nécessaire d’appuyer sur le bouton ROUGE pour arrêter l’alarme « PUMP ».REMPLACEMENT DE LA BATTERIE! ATTENTION DANGER Risque d’électrocution ou d’explosion de la batterie, pouvant causer une blessure grave ou la mort. Porter des lunettes protectrices. Ne travailler que dans un local bien aéré. Ne pas fumer ni laisser une étincelle ou une flamme approcher de la batterie. Éviter de laisser tomber des outils en métal sur la batterie. Si de l’acide de la batterie pénètre dans l’oeil, rincer immédiatement celui-ci à grande eau pendant 15 minutes, et consulter un médecin le plus rapidement possible. Consulter les instructions de sécurité page 1. Deux modèles de batteries Basement Watchdog sont disponibles. (a) Un modèle est équipé de six bouchons qui se vissent dans le dessus de laAB2

batterie; le capteur de niveau de fluide se met dans le bouchon percé de deux trous. (b) L’autre batterie est équipée de deux grands bouchons qui obturent chacun 3 trous. Dans ce type de batterie, le trou destiné au capteur vient de moulage dans le dessus de la batterie.1. Débrancher de la prise de courant le chargeur et le régulateur bleu.2. Retirer le couvercle du boîtier de batterie en le soulevant après avoir appuyé sur les languettes situées à l’avant et à l’arrière. Agiter un morceau de carton (ou d’un matériau non métallique) au-dessus de la batterie pour éliminer hydrogène ou l’oxygène qui en émanerait.3. Retirer le capteur de niveau de fluide de la batterie. Si le capteur se trouvait dans le bouchon de la batterie, retirer le bouchon de la batterie et le garder afin de l’utiliser avec une nouvelle batterie.4. Desserrer les écrous papillons et retirer les câbles de la batterie.

3,4

Retirer

5 6

5. Extraire la vieille batterie de son boîtier, et y mettre la batterie neuve. Remplir la batterie conformément aux instructions page 4.6. Éliminer toute corrosion éventuelle des cosses aux extrémités des câbles de batterie. Nettoyer avec une brosse dure ou du papier abrasif. NE PAS pulvériser de produit ni mettre de rondelles anticorrosion sur les cosses ou les borne après les avoir nettoyées, ceci risquant d’empêcher la charge correcte de la batterie.7. Remettre les câbles de la batterie : le BLANC se branche sur la borne NÉGATIVE (-) et le NOIR sur la borne POSITIVE (+).

BORNE

POSITIVE

7

(+)

BORNE NÉGATIVE(-)

8a

8b

9

10

8. (a) Si la batterie a 6 bouchons, rincer et sécher le bouchon ayant un trou supplémentaire provenant de l’ancienne pour en éliminer les résidus éventuels. Remplacer le bouchon du 2e élément à partir de la borne POSITIVE par le bouchon prélevé sur l’ancienne batterie. Enfoncer le capteur de niveau dans le bouchon. (b) Si le trou destiné au capteur de la batterie neuve est dans le dessus de celle-ci, il n’est pas nécessaire de récupérer le bouchon de l’ancienne batterie; Enfoncer le capteur fermement dans le trou. Ne pas tordre la tige du capteur.9. Brancher le chargeur et le régulateur bleu dans la prise de courant. Remettre le couvercle du boîtier de la batterie en place.10. Il pourra être nécessaire d’appuyer sur le bouton ROUGE pour arrêter l’alarme « PUMP ».

BOUTON TEST BUTTONLe bouton « TEST » peut servir à vérifier la pompe et le système. Appuyer sur le bouton TEST. La pompe se met en fonctionnement pendant l’appui. Elle s’arrête au relâchement du bouton.

TEST DE L’INTERRUPTEUR À FLOTTEURS

Il est important de tester manuellement l’interrupteur à flotteurs périodiquement ainsi qu’après chaque intervention.

Soulever

le

flotteur et le

lâcher. Ceci met

la pompe en

fonctionnement.

Le régulateur fait fonctionner la pompe pendant

SOULEVER LEFLOTTEUR

45 secondes

environ, de

manière à ce

qu’elle puisse

évacuer l’eau contenue dans le puisard. Même

s’il n’y a pas d’eau dans le puisard, la pompe

peut fonctionner à sec pendant cette durée.

L’alarme retentit et le voyant « PUMP » s’allume.

Après l’arrêt de la pompe, appuyer sur le bouton

ROUGE pour arrêter l’alarme. En cas d’appui sur

le bouton ROUGE avant l’arrêt de la pompe,

l’alarme retentit temporairement. Attendre

l’arrêt de la pompe avant d’appuyer sur le bouton

ROUGE pour arrêter complètement l’alarme.

Page 26

SOULEVER LE FLOTTEURESSAI DE L’INTERRUPTEUR À FLOTTEURS DE LA POMPE PRINCIPALESoulever le flotteur dans sa cage à l’aide d’un crayon ou d’un autre objet non métallique, et le laisser retomber. La pompe continue de fonctionner pendant 10 secondes après le retour du flotteur à sa position originale. La pompe n’est pas endommagée par ce bref fonctionnement s’il n’y a pas d’eau dans le puisard. Toutefois, NE PAS SOULEVER le flotteur pendant une durée prolongée s’il n’y a pas d’eau dans le puisard.

Pendant que les pompes fonctionnent, l’eau sortira par le trou de 1/8 po (3,1 mm) situé sur le dessus de la pompe principale, et par le trou de 3/16 po (4,7 mm) situé dans le coude de la pompe de secours. C’est normal. Ces trous sont destinés à empêcher une poche d’air dans le circuit. Ces trous NE DOIVENT PAS ÊTRE OBSTRUÉS, ce qui causerait alors une poche d’air empêchant le fonctionnement du circuit.

AIDE-MÉMOIRE D’ENTRETIENL’entretien doit être effectué 1-2 fois par an.1. Soulever les interrupteurs à flotteurs des deux pompes, comme décrit ci-dessus.2. Éliminer tous les débris du fond du puisard et des crépines des pompes.3. Éliminer tous les débris flottant dans l’eau.4. Éliminer tous les débris éventuels se trouvant dans la cage des flotteurs.5. Remplir le puisard d’eau. S’assurer que les pompes démarrent aux niveaux prévus.6. Pendant que la pompe fonctionne, assurez-vous que la pompe évacue l’eau à un bon rythme et que l’eau sort de l’ouverture d’aération de 1/8 po (3,1 mm) sur le dessus de la pompe et du trou de purge d’air de 3/16 po (4,7 mm) dans le coude de la pompe de secours. Assurez-vous que l’évent et l’orifice de purge d’air ne contiennent pas de débris.7. Retirer de la batterie le capteur de niveau et le bouchon, et rincer ce dernier pour en éliminer toute accumulation noirâtre éventuelle. Remettre le bouchon et le capteur en place.8. Vérifiez et nettoyez les bornes de la batterie.9. Vérifiez les niveaux de liquide de la batterie tous les quatre à six mois.

PIÈCES DE RECHANGE ET RÉPARATIONPour recevoir une aide technique, ou commander des pièces de rechange, téléphoner à GLENTRONICS, INC. au 800-991-0466, option 3, ou consulter le site internet de Basement Watchdog : www.basementwatchdog.com. Pour toute réparation, envoyer votre appareil à l’adresse suivante :Glentronics, Inc. 645 Heathrow Drive, Lincolnshire, IL 60069

Page 27

Liste des pièces détachées

Description

Réf.

Pompe de puisard C.A. de 1/3 HP Interrupteur à deux flotteurs sous cage avec régulateur incorporé Pompe de secours Régulateur de secours Raccord en Y pour tube en PVC Support de pompe de secours Bouchon de batterie percé pour capteur de niveau de fluide Chargeur de pompe de secours Interrupteur à flotteurs de pompe de secours Vis de blocage à tête bombée (N° 12 x 0,5 po) pour pompe de secours* Clapet anti-retour de 1,25 po pour pompe de secours* Clapet anti-retour de 1,5 po pour pompe principale* Manchon en inox* Raccord union en caoutchouc de 1,5 po* Collier, 5 cm (2 po)* Attache-câbles en plastique*

SIT-33NSBWC2 1011004 BWE-CONT 1120007 11210031125000 1015003 1020009110001811410001141001 1142000 1142001 1122002 1122000

*Articles disponibles dans les rayons plomberieTéléphoner au 800-991-0466 (option 3) pour commander des pièces.

N°1100018 VIS DE BLOCAGE POUR POMPE DE SECOURS(DESSOUS DU SUPPORT DE LA POMPE)

VUE DE DESSOUS

N°1020009 INTERRUPTEUR À FLOTTEURSDE POMPE DE SECOURS

N°BWC2

INTERRUPTEUR

PUSH to Test

À DEUX FLOTTEURS

or Reset

SOUS CAGE AVEC

RÉGULATEUR INCORPORÉ

N°BWE-CONT RÉGULATEUR DE SECOURS

N°1142001 RACCORD UNIONN°112007 RACCORD EN Y

N°1122002 COLLIER DE 5 CM (2 PO) DE FIXATION POUR INTERRUPTEUR À FLOTTEURS GRAND MODÈLE

N°1122000 ATTACHE PLASTIQUEPOUR RACCORD

N°1142000 MANCHON FLEXIBLEN°1141000 (SPC-125)CLAPET ANITRETOUR DE 1,25 PO

N°1142000 MANCHON FLEXIBLE

N°1011004 POMPE DE

[xyz-ips snippet=”download-snippet”]