Homedics HUM-PED1 Ultrasonic Cool Mist Humidifier with Built-In SoundSpa Instruction Manual and Warranty Information
Table of Contents
Ultrasonic Cool Mist Humidifier with Built-In SoundSpa
Instruction Manual and Warranty Information
HUM-PED1
Designed with Baby in Mind
Thank you for purchasing the HoMedics® Ultrasonic Cool Mist Humidifier with Built-In SoundSpa. This humidifier combines the soothing comfort of cool mist with 4 rhythmic sounds to create the perfect, calming environment to lull your baby or toddler to sleep.
IMPORTANT SAFETY INSTRUCTIONS:
WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING
DANGER – TO REDUCE THE RISK OF ELECTRIC SHOCK:
Always place humidifier on a firm, flat, level surface. A waterproof mat or pad is recommended for use under the humidifier. Never place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture.
Always unplug the appliance from the electrical outlet immediately after using and before cleaning.
DO NOT reach for an appliance that has fallen into water. Unplug it immediately.
DO NOT use while bathing or in shower.
DO NOT place or store appliance where it can fall or be pulled into a tub or sink.
DO NOT place in or drop into water or other liquid.
NEVER use pins or other metallic fasteners with this appliance.
DO NOT use water above 86˚ Fahrenheit.
WARNING – TO REDUCE THE RISK OF BURNS, FiRE, ELECTRIC SHOCK OR INJURY TO PERSONS:
An appliance should never be left unattended when plugged in.
Close supervision is necessary when this appliance is used by or near children, invalids or disabled persons.
Use this appliance only for its intended use as described in this manual. Do not use attachments not recommended by HoMedics; specifically any attachments not provided with the unit.
NEVER drop or insert any object into any opening.
DO NOT operate where aerosol (spray) products are being used or where oxygen is being administered.
Please hold the water tank firmly with both hands when carrying a full tank of water.
NEVER use humidifier in an environment where explosive gases are present.
DO NOT place the humidifier near heat sources, such as a stove and do not expose the humidifier to direct sunlight.
DO NOT carry this appliance by the power cord or use cord as handle.
To disconnect, turn all controls to the “OFF” position, then remove plug from outlet.
This appliance is designed for personal, non-professional use only.
DO NOT use outdoors. For indoor use only.
SAVE THESE INSTRUCTIONS
CAUTION – PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATION.
Never cover the appliance when it is in operation.
Always keep the cord away from high temperature and fire.
If the cord sustains damage, you must stop using this product immediately and contact HoMedics Consumer Relations. (See the warranty section for HoMedics Consumer Relations address.)
Perform regular maintenance of the Ultrasonic Nebulizer.
Avoid contact with detergent to your mouth and eyes. If contact occurs, use clean water to wash immediately. If serious, contact poison control or seek medical treatment.
Never use detergent to clean the Ultrasonic Nebulizer that is not recommended by the manufacturer.
Never scrape the Ultrasonic Nebulizer with a hard object to clean.
Operation and Maintenance
Do not repair or adjust the unit. Servicing must be performed by professional or qualified personnel.
Stop use if there is an unusual noise or smell. Servicing should be performed by qualified personnel only.
Humidifier should be unplugged when not in use for a long period of time.
Do not touch the water in the main unit or the parts in the water when the unit is on.
Never operate unit without water in the tank. Only use water in the tanks.
Never add any additive to the water that is not produced or under the supervision of the manufacturer.
Do not wash, adjust or move the humidifier without first unplugging the unit from its electrical outlet.
Keep the appliance out of reach from children. Do not allow children to use the appliance without supervision.
Unique Features and Specifications
Ultrasonic Technology
This humidifier uses ultrasonic high frequency technology to convert the water into 1-5 million super particles that are dispersed into the air evenly, moistening the air.
SoundSpa
Plays 4 soothing, rhythmic sounds with adjustable volume and 30 minute auto shut-off to help calm and lull baby to sleep.
Night Light
A useful night light feature is included for your convenience.
Auto Shutoff Protection
When the tank is empty the unit will shut off automatically
Ultrasonic Nebulizer
The humidifier utilizes special spray techniques and the ultrasonic nebulizer is easy to clean for lifetime use.
Voltage
110–120V/60Hz
Watts
25
Tank Capacity
1 gallon – 3.78 liter
Ultrasonic Cool Mist Humidifier With Built-In SoundSpa
How To Use
Power Knob
Plug unit into a 120 volt AC electrical outlet. Turn the POWER /MIST ( ) knob clockwise to turn it on.
ATTENTION: When the water in the tank is almost empty, the humidifying function will power off to indicate to the user to refill water.
Mist Adjustment Setting
Mist adjusts from MINIMUM ( ) mist to MAXIMUM ( ) mist. To increase the mist output, turn the MIST knob clockwise.To decrease mist output, turn the MIST knob counter-clockwise.
Night Light
Press the NIGHT LIGHT ( ) button to turn on the night light. The light ring around the Mist Adjustment and SoundSpa knob control will glow with a soft, illuminating, light.
SoundSpa
NOTE: The SoundSpa feature operates independently of the humidifier. It will continue to operate even if the humidifying function is not operating.
There are 4 soothing, rhythmic sounds included with the SoundSpa feature: Summer Night, Heartbeat, White Noise and Lullaby.
To turn the SoundSpa on, turn the SOUNDSPA POWER/ VOLUME ( ) knob clockwise. The default sound, Summer Night, will begin to play.
To adjust the volume, turn the SOUNDSPA POWER/ VOLUME ( ) knob clockwise to increase the volume and counter-clockwise to decrease the volume.
Choose any one of the 4 sounds by pressing the appropriate sound button.
To turn the SoundSpa off, turn the SOUNDSPA POWER/ VOLUME ( ) knob counter-clockwise until a click is heard and the sound stops.
Sleep Mode
This humidifier includes a Sleep Mode feature. The Sleep Mode will allow the SoundSpa to operate for 30 minutes, then shut off automatically.
To turn the Sleep Mode function on, first press the desired Sound Selection button.
Once the Sound Selection has been made, press the SLEEP ( ) button. This will begin the 30 minute sleep cycle. When the 30 minutes cycle is over, the SoundSpa will automatically stop producing sound and power off.
To power the SoundSpa back on for normal operation after the 30 minute SLEEP MODE cycle is over, turn the SOUNDSPA POWER/VOLUME knob counterclockwise to the OFF position, then back ON. When the SoundSpa is turned back on, the default SUMMER NIGHT sound will begin playing.
To return to normal operation once the Sleep Mode has been activated, and before it shuts off, simply press another Sound Selection button. The sleep mode will turn off, and the new sound selection will run continuously until either the SLEEP ( ) button is pressed, or the SoundSpa is powered off.
NOTE: The humidifier will continue to operate if it is functioning when the Sleep Mode automatically powers off the SoundSpa feature.
How to Fill
Grasp tank handle and lift up from humidifier base
Turn the tank upside down—remove the tank cap by turning it counter-clockwise.
Fill the water tank with clean, cool (not cold) tap water. We recommend using distilled water if you live in a hard water area.
Replace the tank cap by turning clockwise until tight
Install the tank back on the base of the unit. How to Fill Make sure the tank is firmly seated.
CAUTION: Before filling unit with water, turn power off and unplug unit from the outlet.
About White Dust
Use of high-mineral content hard water may cause a white mineral residue to accumulate on room surfaces near the humidifier. The mineral residue is commonly called “white dust”. The higher the mineral content (the harder your water is), the greater the potential for white dust. The white dust is not caused by a defect in the humidifier, but is due only to minerals suspended in the water.
Demineralization Cartridge
The HoMedics demineralization cartridge will help reduce the potential for white dust, a deposit of minerals left behind from using hard water in your humidifier. The cartridge should be replaced every 30-40 fillings. The cartridge may need to be replaced more often when very hard water is used. When the cartridge needs to be changed, white dust will form around the humidifier. If white residue still forms around the humidifier after a new cartridge has been inserted, please make sure that the water you are using is untreated. If you live in a hard water area, or use a water softener, we recommend the use of distilled water for better results from the humidifier. Do not use with water softeners.
Installing Instructions
Remove demineralization cartridge from packaging and let it soak in water for 10 minutes.
Remove the tank from humidifier base. (Fig. 3)
Place 1 demineralization cartridge down into left side matching slot in the humidifier base. (Fig 9)
Place the tank back on the base, making sure the tank is firmly seated. (Fig. 7)
Cleaning and Care
CAUTION: Before cleaning the unit, turn power off and unplug unit from the outlet.
Tank Cleaning
Remove the water tank from the humidifier base by lifting it by the handle from the main unit. Unscrew the tank cap; wipe the tank with a soft cloth then rinse it with clean water. (Fig. 10)Suggestion: Clean the water tank once every two to three weeks, depending on your water conditions.
Ultrasonic Nebulizer Cleaning
Put small amount of mild dish soap on the surface of the ultrasonic nebulizer, then pour in some water and soak for 5 minutes. Brush clean with soft bristle brush (not included) and rinse. (Fig. 11)
Surface Cleaning
Clean the surface of the unit with a clean damp soft cloth. (Fig. 12)
Troubleshooting
Homedics HUM-PED1 Ultrasonic Cool Mist Humidifier with Built-In SoundSpa Instruction Manual and Warranty Information – Homedics HUM-PED1 Ultrasonic Cool Mist Humidifier with Built-In SoundSpa Instruction Manual and Warranty Information –