ACURITE 00606 Wireless Indoor/Outdoor Thermometer with Clock Instruction Manual

DESIGNED TO WORK FOR vou·wireless thermometer #00606

Instruction Manual

Package Contents:

  1.  Main Unit [Al
  2.  Wireless Sensor [Bl
  3. Instruction Manual

What You Need:

  •  [2] AA batteries
  •  [2] MA batteries

Thank You for purchasing this ACURITE® product. Please read this manual in its entirety to fully enjoy the benefits and features of this product. Please keep this manual for future reference.NOTE: A clear film is applied to the LCD at the factory that must be removed prior to using this product. Locate the clear tab and simply peel to remove.

OVERVIEW OF FEATURES 

 SECTION 2 • SETUP

Battery Choice & Temperature RangeExtended periods of cold temperatures I below -4°F / -20°C I can cause alkaline batteries to function improperly. This will cause the outdoor wireless sensor to stop transmitting temperature readings. Use lithium batteries in these low-temperature conditions to ensure continued operation for wireless sensors placed outdoors. NOTE: Rechargeable batteries are not recommended due to higher operating voltages.

 

Install BatteriesNOTE: Install all batteries in both units within a 6 minute period to ensure proper wireless functionality. Always install batteries into the wireless sensor FIRST.

A. Wireless Sensor Remove the battery compartment cover. Install 2 fresh “AA” batteries as shown here.

B. Main UnitRemove the battery compartment cover and install 2 fresh “AAA” batteries as shown here.

Basic Setup is Now CompleteThe wireless sensor will soon send a signal to the main unit and the two units will be synchronized. It may take a few minutes for synchronization to be complete. The wireless sensor signal icon on the display will show 1 to 4 “bars” when the signal is received. If both or one of the units appears to be functioning improperly, refer to the troubleshooting section in this manual.Main Unit : Clock SetAfter installing batteries into the Wireless Sensor and into the Main Unit, the clock can be set.TO SET THE CLOCK:Press and hold the “SET” button for 5 seconds to enter into the CLOCK SET MODE.Once in clock set mode, the preference you are currently setting will blink on the display.The preference set order is as follows:

CLOCK HOUR MODE (12 hours or 24 hours)CLOCK HOURCLOCK MINUTETo adjust the currently selected (flashing) preference item, press the”+” button to adjust up to the desired setting (press and HOLD to fast adjust). To save your adjustments, press the “SET” button again to move on to adjusting the next preference.You will automatically exit the CLOCK SET MODE if no buttons are depressed for 30 seconds. You may enter basic setup mode again at any time by pressing and holding the “SET” button.Main Unit: MIN/Max MemoryThis wireless thermometer features a MIN/MAX memory feature that records the MINIMUM and MAXIMUM indoor and outdoor temperature readings.To view the MAX recorded temperature reading, press and release the “MIN/MAX” button. Note the “MAX” icon on the display.To view, the MIN recorded temperature reading, press and release the “MIN/MAX” button again. Note the “MIN” icon on the display.To clear the MAX recorded values, press and hold the “MIN/MAX” button while in the MAX view mode. Dashes will display in the temperature display to confirm you have cleared the MAX values.To clear the MIN recorded values, press and hold the “MIN/MAX” button while in the MIN view mode. Dashes will display in the temperature display to confirm you have cleared the MIN values.

SECTION 3 • PLACEMENT

Now that setup is complete, you must choose a location to place the wireless sensor and the main unit. The wireless sensor MUST be placed less than 100 feet away from the main unit.This wireless thermometer uses radiofrequency for communication, which is susceptible to interference from other electronic devices and large metallic items or thick walls. Always place both units at least 3 feet away from appliances I TV, microwave, radios, computers, etc. I or objects that may interfere with the wireless communication I large metal surfaces, thick stone walls, etc. ].

Placement of Main Unit

Place the main unit in a dry area free of dirt and dust. To help ensure an accurate indoor temperature measurement, be sure to place themain unit out of direct sunlight, and away from any heat sources or vents in your home. There are 2 placement options for the main unit.You may hang the main unit on a wall using the integrated hang hole.  Alternatively, you may place the main unit on a tabletop or other flat surface.

 

Placement of Sensor

The wireless sensor MUST BE PLACED OUTDOORS to observe outdoor temperatures. The wireless sensor must be placed less than100 feet from the main unit.The wireless sensor is water-resistant and is designed for general outdoor use. However, to extend the life of the product, place thewireless sensor in an area protected from direct weather elements. To ensure an accurate outdoor temperature measurement, be surethe wireless sensor is placed out of direct sunlight and away from any heat sources.There are 2 placement options for the wireless sensor. You may hang it on a wall using one of the two integrated hang holes, or use string[not included] to hang it from a suitable location like a well-covered tree branch.

 

 

Troubleshooting

Problem Possible Solution
 

 

BadWireless SensorReception

 

 

 

 

•Make certain that the batteries are installed correctly into the wireless sensor. The wireless sensor batteries may needreplacing.•Relocate the main unit and/or the wireless sensor. Both units must be within two feet of each other.•Make sure both units are placed at least 3 feet from other electronic appliances and devices that may interfere with the wireless communication [such as TVs, microwaves. radios, computers, etc).

•Make certain there are no large metallic surfaces or very thick stone walls or surfaces between the wireless sensor and the main unit.

•Metal screens or LOW-E windows may interfere with wireless communication.

•In some cases, relocating AND resetting the main unit and wireless sensors (removing and re-installing batteries) may be necessary.

NOTE: It may take up to 20 minutes for the main unit to re-synchronize with the sensor when batteries are replaced. Use lithium batteries in the sensor when the temperature is below -4°F.

Main UnitDisplay Not Working Make certain that the batteries are installedcorrectly. The batteries may need replacing.

 

Please DO NOT return the product to the retail store.For technical assistance and product return information, please callCustomer Care: 877-221-1252 Mon. – Fri. 8:00 A.M. to 4:45 P.M. (CST]www.chaneyinstrument.com

SECTION 4 • PRODUCT SPECIFICATIONS

Measurement RangesTemperatureMainUnit:32°F to 122°F / o0 cto 50°CWireless Sensor: -40°F to 158°F / -40°C to 70°CSpecificationsPower RequirementsMain Unit: 2 x “AAA” alkaline or lithium batteriesWireless Sensor: 2 x “AA” alkaline or lithium batteriesWireless CommunicationRadio Frequency: 433 MhzTransmission Intervals: every 16 seconds

PLEASEDISPOSEOFOLDORDEFECTIVEBATTERIESIN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCALLAWSAND REGULATIONS.BATTERYSAFETY:Followthepolarity(+/-)diagraminthebatterycompartment.Promptlyremovedeadbatteriesfromthe device.DisP-oseofusedbatteriesproperly.Onlybatteriesofthesameorequivalenttypeasrecommendedareto be  used.DONOTincinerateusedbatteries.DONOTdisposeofbatteriesinfire,asbatteriesmayexplodeorleak.DONOTmix oldandnewbatteriesortypesofbatteries(alkaline/standard).DONOTuserechargeablebatteries.DONOTrecharge non-rechargeablebatteries.DONOTshort-circuitthesupplyterminals.

To receive product information, register your product online. Ifs are quick and easy!Log on to http://www.chaneyinstrument.com/product_reg.htm

LIMITEDONEYEARWARRANTYChaney Instrument Company warrants that all products it manufactures be of good material and workmanship and to be free of defects if properly installed and operated for a period of one year from the date of purchase. REMEDYFORBREACHOFTHIS WARRANTY IS EXPRESSLY LIMITED TO REPAIR OR REPLACEMENT OF DEFECTIVE ITEMS. Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from the date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney. In all cases, transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which shall have received normal wear and tear, been damaged, tampered with, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.

THE ABOVE-DESCRIBED WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, AND ALL OTHER WARRANTIES ARE HEREBY EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION THE  IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIEDWARRANTYOFFITNESSFORA  PARTICULAR PURPOSE. CHANEYEXPRESSLYDISCLAIMS ALL  IABILITYFORSPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES, WHETHER ARISING IN  ORTORBYCONTRACTFROM ANY BREACH OF THIS WARRANTY. SOMESTATESDONOTALLOWTHE   CLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OREXCLUSIONMAYNOTAPPLYTOYOU. CHANEYFURTHERDI  CLAIMS ALL LIABILITY FROM FROM PERSONAL INJURY RELATING TO ITS PRODUCTS TO OTHE EXTENT PERMITTED BY LAW.   ACCEPTANCE OFANYOFCHANEY’SEQUIPMENTORPRODUCTS, THE PURCHASER ASSUMES ALL LIABILITY FOR THE  CONSEQUENCES ARISING FROM THE IRUSEORMISUSE. NO PERSON, FIRM, OR CORPORATION IS AUTHORIZED TO ASSUME FOR CHANEY ANY OTHER LIABILITY IN  CONNECTION WITH THE SALEOFITSPRODUCTS.FURTHERMORE, NO PERSON, FIRM OR CORPORATION IS AUTHORIZED TO MODIFY OR WAIVE THE TERMS OF THIS PARAGRAPH, AND THE   PRECEDING PARAGRAPH, UNLESS DONE IN WRITING AND SIGNEDBYA  ULYAU AUTHORIZED AGEN TO CHANEY. THIS WARRANTY GIVES YOU SPECIFIC GALRIGHTS AND OUMAY ALSO HAS OTHER RIGHTS WHICH VARY FROM STATE TO STATE.

For in-warranty repair, please contact:Customer Care DepartmentChaney Instrument Company965Wells StreetLake Geneva,WI 53147

This device complies with part 15 of the FCCrules. Operation issu~ect to the following_two conditions:1- This device may not cause harmful interference, and2- This device must accept any interference received, includinginterference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits aredesigned to provide reasonable protection against harmful interference in a residential installation.This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  •  Reorient or relocate the receiving antenna.
  •  Increase the separation between the equipment and the receiver.
  •  Corne<=;the equipment into an outlet on a circuit different from that to which the receiver 1sconnected.
  • Consult the dealer or an experienced radio/TV technician for help.NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment.Patent numbers: 5,978,738; 6,076,044; 6,597,990

ChaneyCustomerCare877-221-1252Mon-Fri8:00 a.m. to 4:45 p.m. CSTwww.chaneyinstrument.com 