Unpacking Instructions

Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel it off to remove it.

Package Contents

  1. Display with Tabletop Stand
  2. Outdoor Sensor
  3. Instruction Manual

IMPORTANTPRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE

PRODUCT REGISTRATION

Register online to receive 1 year of warranty protection www.AcuRite.com

Features & Benefits

OUTDOOR SENSOR

  1. Integrated HangerFor easy placement.
  2. Wireless Signal IndicatorFlashes when data is being sent to the display.
  3. Battery Compartment
  4. A-B-C SwitchID code that must match display’s A-B-C switch to ensure units synchronize.
  5. Battery Compartment Cover

BACK OF DISPLAY

  1. Integrated Hang HoleFor easy wall mounting.
  2. RESET ButtonFor full reset to factory defaults.
  3. A-B-C SwitchID code that must match sensor’s A-B-C switch to ensure units synchronize.
  4. Battery Compartment Cover
  5. Battery Compartment
  6. Tabletop Stand

Display

FRONT OF DISPLAY

  1. Display Low Battery Indicator
  2. Atomic ClockMaintains time with split-second accuracy and automatically updates for Daylight Saving Time.
  3. MIN IconIndicates today’s low records are being viewed.
  4. Current Outdoor TemperatureThe arrow icon indicates the direction temperature is trending.
  5. Sensor Low Battery Indicator
  6. Heat Index/Dew PointHeat Index calculation displays when the temperature is 80°F (27°C) or above.Dew Point calculation displays when the temperature is 79°F (26°C) or below.
  7. 12 to 24 Hour Weather Forecast Self-calibrating forecasting pulls data from the outdoor sensor to generate your personal forecast.
  8. Multi-Variable History ChartDisplays the past 12 hours of data for pressure, outdoor temperature or outdoor humidity.
  9. MIN/MAX Button For viewing high & low records.
  10. and ButtonsFor setup preferences.
  11. ButtonFor setup preferences.
  12. ButtonPress to toggle between pressure, outdoor temperature, or outdoor humidity on History Chart.
  13. Learning Mode IconDisappears after weather forecast self-calibration is complete.
  14. Current Barometric PressureThe arrow icon indicates the direction pressure is trending.
  15. Current Indoor Temperature The arrow icon indicates direction temperature is trending.
  16. Current Indoor Humidity The arrow icon indicates direction humidity is trending.
  17. Outdoor Sensor Signal Strength
  18. Current Outdoor HumidityThe arrow icon indicates the direction humidity is trending.
  19. MAX IconIndicates today’s high records are being viewed.
  20. Day of the Week/Date
  21. Atomic Clock Signal Strength

SETUP

Sensor Setup

1Set the A-B-C SwitchThe A-B-C switch is located inside the battery compartment. It can be set to A, B, or C. However, you must select the same letterchoices for both the sensor and the display in order for the units to synchronize.2 Install or Replace BatteriesAcuRite recommends high-quality alkaline or lithium batteries for the best product performance.Heavy-duty or rechargeable batteries are not recommended.The sensor requires lithium batteries in low-temperature

conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the sensor for temperatures below -4ºF / -20ºC.

  1. Slide off the battery compartment cover. Take note of the A-B-C switch the setting inside the battery compartment.
  2. Insert 2 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
  3. Replace the battery cover.

Display Setup

1 Set the A-B-C SwitchLocate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B, or C.You must select the same letter choices for both the display and the sensor in order for the units to synchronize.2 Install or Replace Backup Batteries (optional)

  1. Remove the battery compartment cover.
  2. Insert 3 x AA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/–) diagram in the batterycompartment.
  3. Replace the battery cover.

PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment that will not be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in free, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.

Atomic Clock

AcuRite atomic clocks use a radio-controlled signal (RCC) to synchronize to the correct time broadcast by the National Institute of Standards and Technology (NIST) Radio Station WWVB, located near Fort Collins, Colorado. WWVB broadcasts the current timeand date with split-second accuracy.The atomic clock and calendar will maintain the correct time and date and automatically update for Daylight Saving Time to provide the most accurate timekeeping standard possible.NOTE: Signal reception is normally better at night and when the weather is clear. The atomic signal generally takes a few hours to synchronize, so it is important to manually set the time and date after powering on the display.Set the Time, Date & UnitsPress and release the “ ” button, located on the front of the display, to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display.To adjust the currently selected (flashing) item, press and release the “ ” or “ ” buttons (press and HOLD to fast adjust).To save your adjustments, press and release the “ ” button again to adjust the next preference. The preference set order is as follows:

TIME ZONE (EST, CST, MST, PST, AKT, HAT, AST)

AUTO CHANGE for DST? (Daylight Saving Time ON or OFF)*CLOCK HOURCLOCK MINUTECALENDAR MONTHCALENDAR DATECALENDAR YEARTEMPERATURE UNITS (ºF or ºC)BAROMETRIC PRESSURE UNITS (hPa or inHg)ATOMIC CLOCK FUNCTION (ON or OFF)*If you live in an area that observes Daylight Saving Time, DST should be set to ON,even if it is not currently Daylight Saving Time.You will automatically exit the SETUP MODE if no buttons are pressed for 10 seconds. Enter setup mode at any time by pressing the “ ” button.Placement for Maximum AccuracyAcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display and the outdoor sensor is critical to the accuracy and performance of this product.

Display PlacementPlace the display in a dry area free of dirt and dust. Display stands upright for tabletop use or is wall-mountable.Outdoor Sensor PlacementThe sensor must be placed outside to observe outdoor conditions.The sensor is water-resistant and is designed for general outdoor use, however, to extend its life place the sensor in an area protected from direct weather elements.Hang the sensor using the integrated hang holes or hanger, or by using string (not included) to hang it from a suitable location, like a well-covered tree branch. The best location is 4 to 8 feet (1 to 2 meters) above the ground with permanent shade and plenty of fresh air to circulate around the sensor.

Important Placement Guidelines

  • To ensure accurate temperature measurement, place units out of direct sunlight and away from any heat sources or vents.
  • Display and outdoor sensors must be within 330 ft (100 m) of each other.
  • To maximize wireless range, place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.
  • To prevent wireless interference, place both units at least 3 ft (90 cm) away from electronic devices (TV, computer, microwave, radio, etc.).

Setup is CompleteThe sensor will now synchronize with the display. It may take a few minutes for synchronization to complete. Please refer to the troubleshooting section of this manual if anything appears to be functioning improperly.

OPERATION

Using the Weather Station

Learning ModeSelf-calibrating forecasting uses a unique algorithm to analyze changes in pressure over a time period (called Learning Mode) to determine your altitude.After 14 days, the learning mode icon disappears from the display screen. At this point, the self-calibrated pressure is tuned in to your location and the unit is ready for superior weather prediction.Weather ForecastAcuRite’s patented self-calibrating forecasting provides your personal forecast of weather conditions for the next 12 to 24 hours by collecting data from the sensor in your backyard. It generates a forecast with pinpoint accuracy – personalized for your exact location.

View the complete list of icons at www.AcuRite.com/acurite-icons

Barometric PressureSubtle variations in barometric pressure greatly affect the weather. This weather station displays the current pressure with an arrow icon to indicate the direction the pressure is trending (FALLING, STEADY, or RISING).High & Low RecordsToday’s high and low records are displayed for the indoor and outdoor temperature and humidity. Today’s records automatically clear at 12:00 am-midnight every day. View today’s high and low records by pressing and releasing the “ MIN/MAX” button.To manually clear a HIGH or LOW record, press and HOLD both the “ “ and “ “ buttons simultaneously for 3 seconds while viewing the record you wish to clear. Dashes display to confirm you have cleared the record.

Troubleshooting

Problem Possible Solution
No outdoor sensor reception no bars T111I If the wireless signal indicator shows no bars:

  • Relocate the display and/or the outdoor sensor.The units must be within 330 ft (100 m) of each other.
  • Make sure both units are placed at least 3 feet (.9 m) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc.).
  • Use standard alkaline batteries (or lithium batteries in the sensor when the temperature is below -4ºF/-20ºC).Do not use heavy-duty or rechargeable batteries.NOTE: It may take a few minutes for the display and sensor to synchronize after batteries are replaced.
Outdoor temperature  is flashing or showing dashes Flashing of the outdoor temperature is generally an indication of wireless interference.

  1. Bring both the sensor and display indoors and remove batteries from each.
  2. Make sure the A-B-C switches on both units match.
  3. Reinstall batteries in the outdoor sensor.
  4. Reinstall batteries in the display.
  5. Let the units sit within a couple of feet of each other for a few minutes to gain a strong connection.
Inaccurate forecast
  • The Weather Forecast icon predicts conditions for the next 12 to 24 hours, not current conditions.
  • Has the learning mode icon disappeared from the display?Learning Mode must complete before forecast and pressure will be accurate.
  • Allow unit to run continuously for 33 days.Battery removal or resetting the display will restart Learning Mode.After 14 days, the forecast should be fairly accurate, however, Learning Mode calibrates for a total of 33 days.
Inaccurate temperature or humidity
  • Make sure both the display and sensor are placed out of direct sunlight and away from any heat sources or vents (see page 9).
  • Make sure both units are positioned away from moisture sources (see page 9).
Display screen not working
  • Check that the batteries are installed correctly. Batteries may need to be replaced.
  • Reset the display by pressing the reset button, located on the back of the display. The date and time will need to be entered after a reset
Atomic signal or time syncing problems For additional troubleshooting, please visit: http://www.nist.gov/pml/div688/grp40/radioclocks.cfm

If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call 877-221-1252 for assistance.

Care and Maintenance

Display CareClean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt, and moisture. Clean ventilation ports regularly with a gentle puff of air.Outdoor Sensor CareClean with a soft damp cloth. Do not use caustic cleaners or abrasives.CalibrationThe indoor/outdoor temperature and humidity readings, and barometric pressure can be calibrated on the display to improve accuracy. Calibration can improve accuracy when sensor placement or environmental factors impact the data accuracy.

  1. To access calibration mode, press AND HOLD the “,“ “,” and “ “ buttons simultaneously for at least 5 seconds.
  2. To adjust the currently selected (flashing) item, press and release the “ “ or “ “ buttons to calibrate the data value higher or lower than the actual reading.
  3. To save your adjustments, press and release the “ ” button to adjust the next preference. The “ ” icon will remain illuminated next to calibrated values.

The preference set order is as follows:OUTDOOR TEMPERATUREOUTDOOR HUMIDITYINDOOR TEMPERATUREINDOOR HUMIDITYBAROMETRIC PRESSURE (must be set to MANUAL mode to calibrate)**To change from AUTO to MANUAL pressure mode and vice versa, pressAND HOLD the “ ” button for 10 seconds. “manual” will appear under the barometric pressure to indicate that manual mode has been activated. Press and HOLD the “ ” button for 10 seconds to return to AUTO mode. After 10 seconds of inactivity, the display will save the adjustments and exit calibration mode.Note: Calibrations will be erased if the display is reset or if batteries are removed.

Specifications

TEMPERATURE RANGE Outdoor: -40°F to 158°F; -40°C to 70°C
Indoor: 32°F to 122°F; 0°C to 50°C
HUMIDITY RANGE Outdoor: 1% to 99% RH
Indoor: 1% to 99% RH
WIRELESS RANGE 330 ft/100 m depending on home construction materials
OPERATING FREQUENCY 433 MHz
POWER Display: 3 x AA alkaline batteries
Sensor: 2 x AA alkaline or lithium batteries
DATA REPORTING Outdoor temperature & humidity: 18 second updates
Indoor temperature & humidity: 60 second updates

FCC Information

This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:

  1. This device may NOT cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void theuser’s authority to operate the equipment.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of theFCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Thisequipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in aparticular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.Such modifications could void the user’s authority to operate the equipment.This device complies with Industry Canada licence-exempt RSS standard(s).Operation is subject to the following two conditions:

  1. This device may not cause interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation of the device.

Customer Support

AcuRite customer support is committed to providing you with best-in­class service. For assistance, please have the model number of this product available and contact us in any of the following ways:(877) 221-1252Visit us at www.AcuRite.com

Installation Videos► Register your Product►Instruction Manuals► Support User Forum►Replacement Parts► Submit Feedback & IdeasIMPORTANTPRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICEPRODUCT REGISTRATIONRegister online to receive 1-year warranty protectionwww.AcuRite.com

Limited 1-Year Warranty

AcuRite is a wholly-owned subsidiary of Chaney Instrument Company. For purchases of AcuRite products, AcuRite provides the benefits and services set forth herein. For purchases of Chaney products, Chaney provides the benefits and services set forth herein.We warrant that all products we manufacture under this warranty are of good material and workmanship and, when properly installed and operated, will be free of defects for a period of one year from the date of purchase.Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from the date of sale will, upon examination by us, and at our sole option, be repaired or replaced by us. Transportation costs and charges for returned goods shall be paid for by the purchaser. We hereby disclaim all responsibility for such transportation costs and charges. This warranty will not be breached, and we will give no credit for products that have received normal wear and tear not affecting the functionality of the product, been damaged (including by acts of nature), tampered, abused, improperly installed, or repaired or altered by others that our authorized representatives.Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). If we determine that repair or replacement is not feasible, we may, at our option, refund the amount of the original purchase price.THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY FOR THE PRODUCTS AND IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ALL OTHER WARRANTIES OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN ARE HEREBY EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.We expressly disclaim all liability for special, consequential, or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.We further disclaim liability from personal injury relating to our products to the extent permitted by law. By acceptance of any of our products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm, or corporation is authorized to bind us to any other obligation or liability in connection with the sale of our products. Furthermore, no person, Arm, or corporation is authorized to modify or waive the terms of this warranty unless done in writing and signed by a duly authorized agent of ours.In no case shall our liability for any claim relating to our products, your purchase, or your use thereof, exceed the original purchase price paid for the product.Applicability of PolicyThis Return, Refund, and Warranty Policy applies only to purchases made in the United States and Canada. For purchases made in a country other than the United States or Canada, please consult the policies applicable to the country in which you made your purchase.Additionally, this Policy applies only to the original purchaser of our products. We cannot and do not offer any return, refund, or warranty services if you buy products used or from resale sites such as eBay or Craigslist.Governing LawThis Return, Refund, and Warranty Policy are governed by the laws of the United States and the State of Wisconsin. Any dispute relating to this Policy shall be brought exclusively in the federal or state courts having jurisdiction in Walworth County, Wisconsin; and purchaser consents to jurisdiction within the State of Wisconsin.

It’s more than accurate, it’s AcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to Plan your day with confidence™.www.AcuRite.com

©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology.Visit www.AcuRite.com/patents for details.

Printed in China01181 INST 101717

References

[xyz-ips snippet=”download-snippet”]


Posted

in

by