ACURITE 02005TBDI Weather Station Instruction Manual

Instruction ManualWeather Stationmodel 02005TBDI

Questions? Contact Customer Support at (877) 221-1252 or visit www.AcuRite.com.SAVE THIS MANUAL FOR FUTURE REFERENCE.

Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.

Unpacking Instructions 

Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel it off to remove it.

Package Contents

  1. Display Unit
  2. Outdoor Sensor
  3. Instruction Manual

Features & Benefits

OUTDOOR SENSOR

  1. Integrated HangeFor easy placement.
  2. Wireless Signal IndicatorFlashes when data is being sent to the display unit.
  3. Battery Compartment
  4. A-B-C SwitchID code that must match display’s A-B-C switch to ensure units synchronize.
  5. Battery Compartment Cover

Display Unit Front

Display Unit Back

DISPLAY UNIT FRONT

  1. Day of the Week
  2. Current Outdoor TemperatureThe arrow icon indicates the direction the temperature is trending.Outdoor Sensor Signal Strength
  3. High/Low Outdoor Humidity Records
  4. Highest and lowest humidity recordsHighest and lowest humidity records based on record viewing mode (#9).
  5. High/Low Outdoor Temperature RecordsHighest and lowest temperature records based on record viewing mode (#9).
  6. Forecasted High Temperature
  7. Forecasted Low Temperature
  8. 4 Hour Weather Forecast
  9. Record Viewing ModeIndicates viewing records for today, all-time or “ “ auto-mode.
  10. Outdoor Sensor Low Battery Indicator
  11. 4 to 8 Hour Weather Forecast
  12. 8 to 12 Hour Weather Forecast
  13. High/Low Indoor Humidity RecordsHighest and lowest humidity recordsbased on record viewing mode (#9).
  14. High/Low Indoor Temperature RecordsThe highest and lowest temperature records are based on record viewing mode (#9).
  15. Current Outdoor HumidityThe arrow icon indicates the direction the humidity is trending.
  16. Date
  17. Geographic Region SelectionFor setup preferences.
  18. Current Indoor TemperatureThe arrow icon indicates the direction the temperature is trending.
  19. Intelli-Time Clock® 
  20. Display Low Battery Icon
  21. IconAppears while in SET mode.
  22. Current Outdoor HumidityThe arrow icon indicates the direction the humidity is trending.
  23. TIME ZONE & AUTO DSTDISPLAY UNIT BACK
  24. ButtonFor setup preferences.
  25. SET” ButtonFor setup preferences.
  26. A-B-C SwitchID code that must match sensor’s A-B-C switch to ensure units synchronize.
  27. “ButtonFor setup preferences
  28. ” ButtonPress to select record viewing mode (#9).
  29. geo ButtonSet geographical region preferences.
  30. RESET” ButtonFull reset to factory defaults.
  31. zone” ButtonSet time zone preferences.
  32. Battery Compartment
  33. Battery Compartment Cover
  34. Display KickstandFor tabletop placement.
  35. Intelli-Time® Battery Compartment
  36. Integrated Hang HoleFor easy wall mounting.

SETUP

Sensor Setup

  1. Set the A-B-C SwitchThe A-B-C switch is located inside the battery compartment. It can be set to A, B, or C. However, you must select the same letter choices for both the sensor and the display unit in order for the units to synchronize.
  2. Install or Replace Batteries AcuRite recommends high quality alkaline or lithium batteries in the outdoor sensor for the best product performance. Heavy duty or rechargeable batteries are not recommended.The sensor requires lithium batteries in low-temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the sensor for temperatures below -4ºF / -20ºC.1. Slide off the battery compartment cover. Take note of the A-B-C switch setting inside the battery compartment for display unit setup.2. Insert 2 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.3. Replace the battery cover.

 

Display Unit Setup

  1. Set the A-B-C SwitchLocate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B or C. You must select the same letter choices for both the display unit and the sensor in order for the units to synchronize.
  2. Install or Replace Batteries1. Remove the battery compartment cover.2. Insert 3 x AA alkaline batteries into the battery compartment, as shown. Follow the polarity(+/-) the diagram in the battery compartment.3. Replace the battery cover.

PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment that is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in free, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT short-circuit the supply terminals.

Setup: Geographic RegionSelect your geographic region according to the map (pictured right) by pressing the “geo” button, located on the back of the unit in the battery compartment. The letters for each corresponding GEO region are shown on the display screen. The geographic regions must be set in order for Precision Forecasting to function properly. *The “ ” icon and geographic region letter are only visible in GEO set mode. You will automatically exit GEO set mode if no buttons are pressed for 10 seconds. Enter GEO set mode at any time y pressing the “geo” button located inside the battery compartment.

Intelli-Time® ClockIntelli-Time clock and calendar are pre-programmed to the correct time and date and update automatically for Daylight Saving Time. All you need to do is select your time zone using the “zone” button located inside the battery compartment.Set the Time, Date & UnitsPress the “SET” button, located on the back of the display unit, to enter SET MODE. Once in set mode, the preference you are currently setting will blink on the display.To adjust the currently selected (flashing) item, press and release the “ ” or “ “ buttons (press and HOLD to fast adjust).To save your adjustments, press and release the “SET” button again to adjust the next preference. The preference set order is as follows:TIME ZONE ( PST MST CST EST AST HAST AKST)AUTO DST (Daylight Saving Time ON or OFF)*CLOCK HOURCLOCK MINUTECALENDAR MONTHCALENDAR DATECALENDAR YEARUNITS: TEMPERATURE (ºF or ºC)*If you live in an area that observes DST, DST should be set to ON even if it is not currently Daylight Saving Time.You will automatically exit SET MODE if no buttons are pressed for 30 seconds.Enter SET MODE at any time by pressing the “SET” button.Placement for Maximum AccuracyAcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of both the display unit and outdoor sensor are critical to the accuracy and performance of this product.Display Unit PlacementPlace the display unit in a dry area free of dirt and dust. Display stands upright for tabletop use or is wall-mountable. For wall mounting, hang using the keyhole located on the back of the unitOutdoor Sensor PlacementSensors must be placed outside to observe outdoor conditions. The sensor s water-resistant and is designed for general outdoor use, however, to extend its life place the sensor in an area protected from direct weather elements.Hang the sensor using the integrated hang holes or hanger, or by using string (not included) to hang it from a suitable location, like a well-covered tree branch. The best location is 4 to 8 feet above the ground with permanent shade and plenty of fresh air to circulate around the sensor.

Important Placement Guidelines

  • To ensure accurate temperature measurement, place units out of direct sunlight and away from any heat sources or vents.
  • The display unit and outdoor sensor must be within 330 ft (100 m) of each other.
  • To maximize wireless range, place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.
  • To prevent wireless interference, place both units at least 3 ft (.9 m) away from electronic devices (TV, computer, microwave, radio, etc.).

Setup is CompleteThe sensor will now synchronize with the display unit. It may take a few minutes for synchronization to complete. NOTE: It will take up to 4 hours to generate a weather forecast after initial setup.

OPERATIONUsing the Weather StationPrecision Weather ForecastingAcuRite’s Precision Forecasting provides your personal forecast of morning, noon & night (4 hours, 4 to 8 hours, and 8 to 12 hours) weather conditions. The patent-pending technology combines regional weather patterns with data easured by a sensor in your yard. It generates a forecast with pinpoint accuracy – personalized for your exact location.

View the complete list of icons at www.AcuRite.com/acurite-icons

High & Low RecordsToday’s high and low records are displayed for the indoor and outdoor temperature and humidity. Today’s records automatically clear at 12:00 am-midnight every day. All-time high and low records are the maximum and minimum readings recorded since batteries were installed.Press the “ ” button to cycle through records for “today”, “all-time”, or “ ” auto-mode. High & low records will automatically cycle through “today” and “all-time” when “ ” auto-mode is selected.To manually reset the high/low records currently being viewed, press and hold the “ ” on the back of the display to clear high records or press and hold “ ” on the back of the display to clear low records. Dashes display to confirm you have cleared the records.

Troubleshooting

No outdoor sensor reception no bars if the wireless signal indicator shows no bars:•Relocate the display unit and/or the outdoor sensor. The units must be within 330 ft (100 m) of each other.•Make sure both units are placed at least 3 feet (.9 m) away from electronics that may interfere with the wireless communication (such as TVs, microwaves, computers, etc).•Use standard alkaline batteries (or lithium batteries in the sensor when the temperature is below -4°F/-20°C). Do not use heavy-duty or rechargeable batteries. NOTE: It may take up to 20 minutes for the display unit and sensor to synchronize after batteries are replaced.
Display screen not working •Check that the batteries are installed correctly. Batteries may need to be replaced.•Reset display by pressing the RESET button, located in the battery compartment on the display unit. Time and date will need to be entered after a reset.•Forecast will be blank for first 4 hours after battery installation.
Outdoor topwater is flashing orshowing asks Flashing of the outdoor temperature is generally an indication of wireless interference.1. Bring both the sensor and display unit indoors and remove batteries/power adapter from both.2. Make sure the A-B-C switch on both units matches.3. Reinstall batteries in the outdoor sensor.4. Reinstall batteries in the display unit.5. Let the units sit within a couple of feet of each other for about 20 minutes to gain a strong connection.
Mamma% temperature or humidity •Make sure both the display unit and sensor are placed out of direct sunlight and away from any heat sources or vents (see page 8).•Make sure both units are positioned away from any sources of moisture.
Inaccurate forecast •Weather Forecast icons predict conditions for the future, not current conditions.• Forecast will be blank for the first 4 hours after battery installation.• Make sure your GEO region is correct. If you live close to a region border, try testing both regions to see which generates the most appropriate forecastfor your location.•Make sure time, date, GEO region, temperature, humidity and pressure are accurate. Note: It may take up to 14 days for the pressure to calibrate toyour location.•Calibrate the forecast (see page 12).• If the forecast reads inaccurately after all other troubleshooting steps have been attempted, press and release the “RESET” button (inside the battery compartment), time and date will need to be entered after a reset. Next, press the “geo” button to toggle through each of the regions (A-B-C-D-E-F-G) andback to your correct region.
The unit lost power or batteries werechanged and the time is not correct The Intelli-Time battery needs to be replaced (see page 12). Once the new battery is installed, the time and date will need to be set manually.

If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call (877) 221-1252 for assistance.

Care & Maintenance

Display Unit CareClean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep away from dust, dirt, and moisture. Clean ventilation ports regularly with a gentle puff of air.Outdoor SensorCare Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.

Replace Intelli-Time® Clock Battery

Intelli-Time technology is powered by a pre-installed coin-cell battery that stores the time and date settings.  The battery has a shelf life of several years. To replace the  Intelli-Time battery:

  1. Locate the coin cell battery inside the battery compartment of the display unit. Unscrew and remove the compartment cover.
  2. Insert 1 x CR2032 coin cell battery into the battery compartment, as shown. Install battery with “+” positive terminal facing OUT.
  3. Screw in the battery cover.

Calibration

Calibrate Weather ForecastThe forecast can be calibrated on the display unit to improve accuracy when sensor placement or environmental factors impact your data accuracy. The calibration increases or decreases the amount of moisture in the forecast algorithm. For example, if you feel the forecast is showing rain too often you may want to remove 10% of the moisture from the forecast equation.

  1. To enter calibration mode, press and HOLD the “ ” and ““ buttons for at least 3 seconds.
  2. The “ “ will begin flashing, indicating it is ready to be calibrated.
  3. Press the “ ” button to increase moisture in the forecast or press the ““ button to remove moisture from the forecast.
  4. Press the “SET” button to confirm the calibration adjustment, or after 20 seconds of inactivity, the display will automatically save your adjustments and exit calibration mode.

Specifications

TEMPERATURE RANGE Outdoor: -40°F to 158°F; -40°C to 70°C
Indoor: 32°F to 122°F; 0°C to 50°C
HUMIDITY RANGE Outdoor: 1% to 99% RH
Indoor: 1% to 99% RH
WIRELESS RANGE 330 ft / 100 m depending on home construction materials
OPERATING FREQUENCY 433 MHz
POWER Display: 3 x AA alkaline batteries
Sensor: 2 x AA alkaline or lithium batteries
DATA REPORTING Outdoor Data: 16-second updates
Indoor Data: 60-second updates

FCC Information

This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:1- This device may NOT cause harmful interference, and2- This device must accept any interference received, including interference that may cause undesired operation.WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur n a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the  user is encouraged to try to   correct the interference by one or more of the following  measures: 

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver disconnected.
  • Consult the dealer or an experienced radio/TV technician for help.

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.Such modifications could void the user’s authority to operate the equipment. This device complies with Industry Canada licence-exempt  SS standard(s).Operation is subject to the following two conditions:

  1. This device may not use interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation of the device.

Customer Support

AcuRite customer support is committed to providing you with best-in-class service. For assistance, please have the model number of this product available and contact us in any  the following ways:(877) 221-1252[email protected]24/7 support at www.AcuRite.com

  • Installation Videos
  • Instruction Manuals
  • Replacement Parts
  • Register your Product
  • Support User Forum
  • Submit Feedback & Ideas

Limited One Year Warranty

At AcuRite, we proudly uphold our commitment to quality technology. Chaney Instrument Co. warrants that all products it manufactures be of good material and workmanship and to be free of defects when properly installed and operated for a period of one year from the date of purchase.We recommend that you visit us at www.AcuRite.com for the fastest way to register your product. However, product registration does not eliminate the need to retain your original proof of purchase in order to obtain warranty benefits.Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship and to be free of defects when properly installed and operated for a  period of one year from the date of purchase. Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from the date of sale will, upon examination by Chaney, and at its sole option, be repaired or eplaced by Chaney. Transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which have received normal wear and tear, been damaged (including by acts of nature), tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose. Chaney expressly disclaims all liability for special, consequential or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Chaney further disclaims all liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of Chaney’s products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm, or corporation is authorized to assume for Chaney any other liability in connection with the sale of its products. Furthermore, no person, firm, or corporation is authorized to modify r waive the terms of this paragraph, and the preceding paragraph, unless done in writing and signed by a duly authorized agent of Chaney. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.For in-warranty claims: Chaney Instrument Co.965 Wells St., Lake Geneva, WI 53147

It’s more than accurate, it’sAcuRite offers an extensive assortment of precision instruments,designed to provide you with information you can depend on toPlan your day with confidence™.www.AcuRite.com

©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology. Visit www.AcuRite.com/patents for details.

Printed in China02005TBDI INST 100714

References

[xyz-ips snippet=”download-snippet”]


Posted

in

by