AcuRite VN1TXC 5-in-1 Sensor Instruction Manual

Instruction Manual5-in-1 Sensormodel 06004RM/VN1TXC 

Package Contents

  1. 5-in-1 Sensor
  2. Mounting hardware
  3. Sensor mounting bracket
  4. Snap-in debris filter for rain collector
  5. Instruction Manual
IMPORTANTPRODUCT REGISTRATIONRegister online to receive 1 year warranty protectionwww.AcuRite.com PRODUCT MUST BE REGISTEREDTO RECEIVE WARRANTY SERVICE

Questions? Contact Customer Support at(877) 221-1252 or visit www.AcuRite.com.

Features & Benefits

5-in-1 SENSOR

  1. Rainfall Collector Funnel
  2. Solar Cell PanelConverts sunlight into power to run the internal aspirating fan.Internal Aspirating Fan(not shown)Draws ambient air into the sensor to reduce solar radiation heating, resulting in more accurate temperature measurement.
  3. A-B-C Switch
  4. Battery Compartment
  5. Temperature & Humidity Sensors(internal)
  6. Mounting Point
  7. Wind Speed Anemometer
  8. Wind Direction Vane
  9.  Mounting Bracket
  10.  Mounting HardwareIncludes anchors & screws.
    Qty  Diameter Length
    4 #4 1”
    2 #6 ½”
  11. Debris FilterSnaps into rain collector to filter out twigs, leaves, etc.

SETUP5-in-1 Sensor Setup

  1. Set the A-B-C SwitchLocate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B, or C. You must select the same letter choice for both the sensor and the companion unit (not included) in order for the units to synchronize.
  2.  Install or Replace BatteriesBatteries MUST be installed for this product to operate. AcuRite recommends high-quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended.The 5-in-1 sensor requires lithium batteries in low-temperature conditions. Cold temperatures can cause alkaline batteries to functionimproperly. Use lithium batteries in the 5-in-1 sensor for temperatures below -4ºF / -20ºC.
  3. Remove Rain Gauge StabilizerLocate and remove the rain gauge stabilizer (plastic tab) taped into the bottom of the sensor. The rain gauge will not function until this is removed.

PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.BATTERY SAFETY: Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment that is not to be used for an extended period of time. Follow the polarity (+/-) diagram in the battery compartment. Promptly remove dead batteries from the device. Dispose of used batteries properly. Only batteries of the same or equivalent type as recommended are to be used. DO NOT incinerate used batteries. DO NOT dispose of batteries in free, as batteries may explode or leak. DO NOT mix old and new batteries or types of batteries (alkaline/standard). DO NOT use rechargeable batteries. DO NOT rechargenon-rechargeable batteries. DO NOT short-circuit the supply terminals.

Placement for Maximum Accuracy

AcuRite sensors are sensitive to surrounding environmental conditions. Proper placement of the sensor is critical to the accuracy and performance of this product.

5-in-1 Sensor PlacementThe 5-in-1 sensor is designed to remain outdoors all year long.Choose an open location with no obstructions above or around the sensor for the most accurate measurements.

Important Placement GuidelinesThe sensor must be within 330 feet (100 m) of the companion unit (not included).MAXIMIZE WIRELESS RANGE Place sensor away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.LOCATE AWAY FROM HEAT SOURCESPosition sensor away from heaters, air conditioners, chimneys, exhaust vents, asphalt, and concrete (surfaces that radiate heat).LOCATE AWAY FROM HUMIDITY SOURCESAvoid installing the sensor near pools, spas, or other bodies of water. Water sources may impact humidity accuracy.LOCATE AWAY FROM SPRINKLER HEADSDO NOT install the sensor where it will be sprayed by a sprinkler system. This may force water inside the sensor.LOCATE AWAY FROM WIND & RAIN OBSTRUCTIONSDO NOT mount the sensor with obstructions around it.Consider a location that is a wide-open area, with few structures around to ensure accurate wind measurement.

Learn more at: www.AcuRite.com/5in1

http://www.acurite.com/5in1?utm_source=01502BPDI&utm_medium=qr&utm_campaign=Instructions

5-in-1 Sensor Installation GuidelinesINSTALLATION HEIGHT Mount the sensor at least 5 feet (1.5 meters) off the ground (higher is better for wind measurement) in an open area. Secure to a fence post, 2”x 4” wood, 3/4” pole, etc. (not included)LEVEL INSTALLATION Use the bubble level on the top of the sensor to ensure level installation for accurate wind and rain measurement.

SOLAR CELL INSTALLATION Install the sensor with the solar cell facing SOUTH.This ensures the cell receives as much sun as possible and orients wind direction.

5-in-1 Sensor Installation

  1. Fasten mounting base (included) to a post or pole (not included) using the 4 longer screws included in the hardware bag.
  2.  Insert the mounting base into the hole on the bottom of the sensor.
  3. Make sure the arrows on the top of the sensor are pointed in the proper direction and the bubble level is centered. The solar cell should be facing south to properly orient the wind direction.
  4. Fasten the sensor into the mounting base using the 2 shorter screws included in the hardware bag.

The 5-in-1 sensor is now ready to use.Clear Data Collected During InstallationWhen the installation is complete, clear erroneous data from the companion unit (not included). Please refer to the companion unit’s instruction manual for details.Basic Setup is CompleteThe 5-in-1 sensor will now synchronize. It may take a few minutes for synchronization to complete.Calibrate the Rain GaugeThe rain gauge on the 5-in-1 sensor can be calibrated to improve accuracy.Items Needed: 5-in-1 sensor, companion unit, plastic cup, pin, screwdriver

  1. First, ensure the 5-in-1 sensor is perfectly level using a built-in bubble level.
  2. Use a compatible companion unit or AcuRite software to monitor during calibration.
  3. Make a pinhole in the bottom of a plastic cup. Hold the cup over the rain gauge and fill it with exactly 1 cup (8oz) of water, allowing the water to drip into the rain gauge. You should hear the internal buckets tip and see water drain through the rain gauge.
  4. A few seconds after each bucket tip, the companion unit displays rainfall in approximately 0.01” or more increments.
  5. The cup of water should take more than 20 minutes to empty; a quicker period will result in an inaccurate calibration. Try to simulate a normal steady rainfall. When cup is empty of water, the companion unit should register 1.06”

Tips

  • There should be nearly an equal number of water drops (about 25 water drops) between bucket tips. If not, adjust the calibration screws on the bottom of the 5-in-1 sensor until an equal number of water drops are tipping the buckets.

AdjustmentIf the rain gauge doesn’t register close to 1.06”, make an EQUAL adjustment to the two calibration screws on the bottom of the 5-in-1 sensor. Turning screws clockwise increases rainfall; counterclockwise decreases rainfall.

  • To adjust the rainfall reading by 2% turn both screws 1/8 of a turn.
  • To adjust the rainfall reading by 4% turn both screws 1/4 of a turn.
  •  To adjust the rainfall reading by 8% turn both screws 1/2 of a turn.

Watch the video at www.AcuRite.com/5n1

Customer Support

AcuRite customer support is committed to providing you with best-in-class service.For assistance, please have  the model number of this product available and contact us in  any of the following ways:

(877) 221-1252 [email protected]

24/7 support at www.AcuRite.com► Installation Videos► Register your Product► Instruction Manuals► Support User Forum► Replacement Parts► Submit Feedback & Ideas

Specifications

TEMPERATURE RANGE Outdoor: -40ºF to 158ºF; -40ºC to 70ºC
HUMIDITY RANGE Outdoor: 1% to 99%
WIND SPEED 0 to 99 mph; 0 to 159 kph
WIND DIRECTION INDICATORS 16 points
RAINFALL 0 to 99.99 in; 0 to 99.99 cm
WIRELESS RANGE 330 ft / 100 m depending on home construction materials
OPERATING FREQUENCY 433 MHz
POWER 4 x AA alkaline or lithium batteries
DATA REPORTING Wind Speed: 18 second updates; Direction: 30 second updates Outdoor temperature & humidity: 36 second updates

Limited 1-Year Warranty

At AcuRite, we proudly uphold our commitment to quality technology. Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship and to be free of defects when properly installed and operated for a period of one year from the date of purchase.We recommend that you visit us atwww.AcuRite.com for the fastest way to register your product. However, product registration does not eliminate the need to retain your original proof of purchase in order to obtain warranty benefits.Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship and to be free of defects when properly installed and operated for a period of one year from the date of purchase. Remedy for breach of this warranty is limited to repair or replacement of the defective item(s). Any product which, under normal use and service, is proven to breach the warranty contained herein within ONE YEAR from the date of sale will, upon examination by Chaney, and at its sole option, be repaired or replaced by Chaney.Transportation costs and charges for returned goods shall be paid for by the purchaser. Chaney hereby disclaims all responsibility for such transportation costs and charges. This warranty will not be breached, and Chaney will give no credit for products it manufactures which have received normal wear and tear, been damaged (including by acts of nature), tampered, abused, improperly installed, damaged in shipping, or repaired or altered by others than authorized representatives of Chaney.The above-described warranty is expressly in lieu of all other warranties, express or implied, and all other warranties are hereby expressly disclaimed, including without limitation the implied warranty of merchantability and the implied warranty of fitness for a particular purpose. Chaney expressly disclaims all liability for special, consequential, or incidental damages, whether arising in tort or by contract from any breach of this warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. Chaney further disclaims all liability from personal injury relating to its products to the extent permitted by law. By acceptance of any of Chaney’s products, the purchaser assumes all liability for the consequences arising from their use or misuse. No person, firm, or corporation is authorized to assume for Chaney any other liability in connection with the sale of its products. Furthermore, no person, firm, or corporation is authorized to modify or waive the terms of this paragraph, and the preceding paragraph, unless done in writing and signed by a duly authorized agent of Chaney. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.For in-warranty claims: Chaney Instrument Co.965 Wells St., Lake Geneva, WI 53147 

It’s more than accurate, it’sAcuRite offers an extensive assortment of precision instruments, designed to provide you with information you can depend on to Plan your day with confidence™.www.AcuRite.com

© Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology.Visit www.AcuRite.com/patents for details.

Printed in China06004RM INST 061114

References

[xyz-ips snippet=”download-snippet”]


Posted

in

by