©2020 ADJ Products, LLC all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ADJ Products, LLC logo and identifying product names and numbers herein are trademarks of ADJ Products, LLC. Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. All non-ADJ Products, LLC brands, and product names are trademarks or registered trademarks oftheir respective companies.ADJ Products, LLC and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product.
DOCUMENT VERSIONPlease check www.adj.com for the latest revision/update of this guide.
Date | DocumentVersion | Software Version ≥ | DMX Channel Mode | Notes |
10/19’17 | I | I.03 | 1/2/3/4 | Initial Release |
6/26/18 | 2 | I .04 | 1/2/2-2/3/2-3/4 | Added Additional DMX Modes Added Stage 2 Dimmer Curve Added 1.0 Gamma Correction |
9/18/20 | I .06 | NO CHANGE | Updated for System Menu, Operating Instruction, and Primary-Secondary Configuration. |
Europe Energy Saving NoticeEnergy Saving Matters (EuP 2009/125/EC)Saving electric energy is a key to helping to protect the environment. Please turn off all electrical products when they are not in use. To avoid power consumption in idle mode, disconnect all electrical equipment from power when not in use. Thank you!
Introduction
Unpacking: Thank you for purchasing the Encore FR50z by ADJ Products, LLC. Every Encore FR50z has been thoroughly tested and has been shipped in perfect operating ondition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your fixture for any damage and be sure all accessories necessary to operate the unit have arrived intact. In the case damage has been found or parts are missing, please contact our toll-free customer support number for further instructions. Do not return this unit to your dealer without first contacting customer support.Introduction: The ADJ Encore FR50z is a DMX intelligent, high-powered LED fresnel fixture. This fixture can be used in a stand-alone setup or connected in a Primary/Secondary setup. The Encore FR50z has two operating modes: dimmer control and DMX controlled. To optimize the performance of this product, please read these operating instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference. Customer Support: ADJ provides a customer support line, to provide setup help and to answer any question should you encounter problems during your setup or initial operation. You may also visit us on the web at www.adj.com for any comments or suggestions. Service Hours are Monday through Friday 8:00 a.m. to 4:30 p.m. Pacific Standard Time.
Voice: (323) 582-3322Fax: (323) 582-3108E-mail: [email protected]
Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.Caution! There are no user-serviceable parts inside this unit. Do not attempt any repairs yourself, doing so will void your manufactures warranty. In the unlikely event your unit may require service please contact ADJ Products, LLC.PLEASE recycle the shipping carton whenever possible.
Features
- Two Operating Modes
- Electronic Dimming 0-100%
- DMX-512 protocol
- 6 DMX Channel Modes
- 3-Pin In/Out DMX Connection
- PowerCON In/Out Connection
- USB Data Update
- Gamma Adjustment
- 5 Dimmer Curves
- Multiple Unit Power Linking (See page 14)
Warranty Registration
The Encore FR50z carries a 2-year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight prepaid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem, as well as the R.A. number, must also be written down on a piece of paper included in the shipping carton. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain an R.A. number by contacting our customer support team on our customer support number. All packages returned to the service department not displaying an R.A. number on the outside of the package will be returned to the shipper.
Installation
The unit should be mounted using a mounting clamp (not provided), affixing it to the mounting bracket that is provided with the unit. Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times the unit’s weight. Also, always use a safety cable that can hold 12 times the weight of the unit when installing the fixture. The equipment must be installed by a professional, and it must be installed in a place where it is out of the reach of people’s grasp.
Safety Precautions
- To reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture
- Do not spill water or other liquids into or onto your unit.
- Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and fire in case of an internal short.
- Disconnect from the main power before making any type of connection.
- Do not remove the cover under any conditions. There are no user-serviceable parts inside.
- Never operate this unit when it’s cover is removed.
- Never plug this unit into a dimmer pack
- Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6”(15cm) between this device and a wall.
- Do not attempt to operate this unit, if it becomes damaged.
- This unit is intended for indoor use only, use of this product outdoors voids all warranties.
- During long periods of non-use, disconnect the unit’s main power.
- Always mount this unit in safe and stable matter.
- Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to the point they exit from the unit.
- Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See page 15 for cleaning details.
- Heat -The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat.
- The fixtures should be serviced by qualified service personnel when:A. The power-supply cord or the plug has been damaged.B. Objects have fallen, or liquid has been spilled into the fixture.C. The fixture has been exposed to rain or water.D. The fixture does not appear to operate normally or exhibits a marked change in performance.E. The fixture has fallen and/or been subjected to extreme handling.
Layout
1. Zoom Adjustment Knob2. Power In3. 3-Pin DMX In4. 3-Pin DMX Out5. Power Out6. Mode Button7. USB Port | 8. Enter Button9. LCD Menu Control Display10. Down Button11. Up Button12. Barn Door Secure Lock13. Gel Frame |
DMX Set Up
Power Supply: The ADJ Encore FR50z contains an automatic voltage switch, which will auto-sense the voltage when it is plugged into the power source. With this switch there is no need to worry about the correct power voltage, this unit can be plugged in anywhere.DMX-512: DMX is short for Digital Multiplex. This is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMXdata is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).DMX Linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all fixtures and the controller are DMX compliant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.Data Cable (DMX Cable) Requirements (For DMX Operation): The Encore FR50zcan be controlled via DMX-512 protocol. The Encore FR50z has 6 DMX channel modes. The DMX address is set on the back panel of the Encore FR50z. Your unit and your DMX controller require a standard 3-pin XLR connector for data input and data output (Figure 1). We recommend Accu-Cable DMX cables. If you are making your own cables, be sure to use standard 110-120 Ohm shielded cable (This cable may be purchased at almost all pro lighting stores). Your cables should be made with a male and female XLR connector on either end of the cable. Also, remember that DMX cable must be daisy-chained and cannot be split.Notice: Be sure to follow figures two and three when making your own cables. Do not use the ground lug on the XLR connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR’s outer casing. Grounding the shield could cause a short circuit and erratic behavior.
XLR Pin ConfigurationPin 1 = GroundPin 2 = Data Compliment (negative)Pin 3 = Data True (positive)
Special Note: Line Termination. When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behavior. A terminator is a 110-120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA -). This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line. Using a cable terminator (ADJ part number Z-DMX/T) will decrease the possibility of erratic behavior.
5-Pin XLR DMX Connectors. Some manufactures use 5-pin DMX-512 data cables for DATA transmission in place of 3-pin. 5-pin DMX fixtures may be implemented in a 3-pin DMX line. When inserting standard 5-pin data cables into a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion | ||
Conductor | 3-Pin XLR Female (Out) | 5-Pin XLR Male (In) |
Ground/Shield | Pin 1 | Pin 1 |
Data Compliment (- signal) | Pin 2 | Pin 2 |
Data True (+ signal) | Pin 3 | Pin 3 |
Not Used | Do Not Use | |
Not Used | Do Not Use |
Specifications are subject to change without any prior written notice | ||||
MENU | SUBMENU | OPTIONS (Default Settings in BOLD) | DESCRIPTION | |
Opening Display | Update Wait … WELCOME EFR5OZV1.04 | Start-Up Display | ||
InterfaceDisplay | ADDR:00I CH:02 | Main Display | ||
MENU Set ADDR | Set ADDR 001 | 001-509 | DMX Addressing | |
MENUUser Mode | 1/5/2 -2/ 3/ 2-3/4CH | DMX Channel Mode Selection | ||
MENUFunction | NO DMX | Lost Dmx | Black/Hold | DMX Lost Status |
LCD.Set | DisplayKey Lock Flash | ON/OFF ON/OFF/ONION/OFF | Display Settings | |
Temp | Celsius Fahren | Temperature Setting | ||
Dim Curve | Standard StageArchitectArTheatreStage 2 | Dimming Curve Modes | ||
Disp.Set | ADDRESSDisp. CH Secondary | Main Display Setting | ||
Gamma | 1.0/2.0/2.2/2.4/2.8 | Gamma Brightness | ||
USB Data Off | ON/OFF | Software Upload | ||
DFSE | ON/OFF | Return to Default Settings |
MENUInfo | Time Into | Current | Current Running Time (Hours) |
Total info | Total Running Time (Hours) | ||
Last Clea | LastRunningTime Cleared (Hours) | ||
Timer Pin | Clear Running Time(Password-050) ON/OFF | ||
Temp info | Tani) Info | Current LED Temperature | |
Err. Info | TempErr | Error Information | |
Modeling | Encore FR5OZ | Model Identification | |
Software | VI.06 | Current Software Version | |
MENUManual | ManCtrl | Dimmer=XXX Strobe=XXX | Manual Control Mode |
Operating Instructions
DMX Addressing:Operating through a DMX controller gives the user the freedom to create their own programs tailored to their own individual needs.
- To run your fixture in DMX mode press the UP or DOWN buttons until “Set ADDR” is displayed.Press the ENTER button and “Set ADDR XXX” will be displayed. “XXX” represents the currently displayed address.
- Use the UP or DOWN buttons to find your desired DMX address and press ENTER to save the address.
- Please see page 14 for DMX values and traits.
- After you have chosen your desired DMX Channel mode (see below) plug in the fixture via the XLR connections to any standard DMX controller.
DMX Channel Mode:
The Encore FR50z has 6 DMX channel modes. This submenu will allow you to choose the DMX channel mode you like the unit to operate under.
- To select your desired DMX channel mode press the MODE button until “UserMode” is displayed. Press the ENTER button and the current DMX channel mode will be displayed.
- Use the UP or DOWN buttons to find your desired DMX channel mode and press ENTER to save the model.
- Please see page 14 for your selected DMX mode values and traits.
- After you have chosen your desired DMX Channel mode plug in the fixture via the XLR connections to any standard DMX controller.
DMX State:This mode can be used as a precaution mode, that in case the DMX signal is lost, the operating mode chosen in the setup is the running mode the fixture will go into when the DMX signal is lost. You can also set this as the operating mode you would like the unit to return to when power is applied.
- Plug the fixture in and press the UP or DOWN buttons until “Menu Function” is displayed.
- Press the ENTER button and then use the UP or DOWN buttons to scroll to “NO DMX” and press enter. Use the UP or DOWN buttons to toggle between the two choices:• “Black” (Blackout) – If the DMX signal is lost or interrupted, the unit will automatically go into standby mode.• “Hold” (Last State) – If the DMX signal is lost or interrupted, the fixture will stay in the last DMX set up.
- Once you have found your desired model, press ENTER, and press MODE to exit.
LCD Set Up – In this submenu, you are able to adjust the settings for the LCD display. You can program the display to blackout after 30 seconds, lock the buttons, or make the display flash.
- Plug the fixture in and press the UP or DOWN buttons until “Menu Function” is displayed.
- Press the ENTER button and press the UP or DOWN buttons to scroll to “LCD.Set” and press ENTER.
- Use the UP or DOWN buttons to make your desired adjustments in each submenu. Press the ENTER button to move to the next adjustment submenu.
- Press the MODE button to exit and return to the main menu.
Unit Temperature – With this function, you can switch the temperature setting between Celsius or Fahrenheit.
- Plug the fixture in and press the UP or DOWN buttons until “Menu Function” is displayed.
- Press the ENTER button and press the UP or DOWN buttons to scroll to “TEMP” and press ENTER.
- Use the UP or DOWN buttons to switch between “Celsius” or “Fahren”.
- Press ENTER to confirm your selection or press the MODE button to exit and return to the main menu.
Dimmer Curve Setting:
- Plug the fixture in and press the UP or DOWN buttons until “Menu Function” is displayed.
- Press the ENTER button and then use the UP or DOWN buttons to scroll to “DimCurve” and press ENTER.
- There are 6 dimmer curve settings to choose from. Use the UP and DOWN buttons to scroll through the different dimmer curve settings. See the Dimmer Curve Diagram Chart on page 14 to see the different settings and their respective beginning and ending fade times.
- Press the MODE button to exit and return to the main menu.
Display Set Up – In this submenu, you are able to select what the main display will show. In this sub-menu, you are able to designate the unit as the “Secondary” in the Primary- Secondary mode.
- Plug the fixture in and press the UP or DOWN buttons until “Menu Function” is displayed.
- Press the ENTER button and press the UP or DOWN buttons to scroll to “Disp. Set” and press ENTER.
- Use the UP or DOWN buttons to find your desired setting and press ENTER.
- Press the MODE button to exit and return to the main menu.
Gamma Correction – With this function, you can optimize the brightness of the fixture. This is used mainly when recording with an HD video camera. The brightness will be slight to the naked eye, but looking through the lens of a camera it will be noticeable.
- Plug the fixture in and press the UP or DOWN buttons until “Menu Function” is displayed.
- Press the ENTER button and press the UP or DOWN buttons to scroll to “Gamma” and press ENTER.
- Use the UP or DOWN buttons to switch between the different gamma settings.
- Press ENTER to confirm your selection or press the MODE button to exit and return to the main menu.
Software Update (USB Data) – This submenu is used for any future software updates. Check www.adj.com and this unit’s webpage for any software updates. Download the software update to a flash stick and plug the flash stick into the Flash Drive slot located on the side of the unit.
- Contact ADJ customer service for help when updating software.
Default Running Mode:This is a default running mode. When this mode is activated all modes will return to their default settings.
- Plug the fixture in and press the UP or DOWN buttons until “Menu Function” is displayed and press ENTER.
- Press the UP or DOWN buttons to scroll to “DFSE” and press ENTER.
- Press the UP and DOWN buttons to switch between “ON” or “OFF”. To reset the unit to factory settings select “ON” and press ENTER. Press the MODE button to exit the submenu with no changes.
Time Infomation – In this submenu, you are able to check the current running time, total running time, last time the running time was cleared, and clear the running time.
- Plug the fixture in and press the UP or DOWN buttons until “Info” is displayed.
- Press the ENTER button and press the UP or DOWN buttons until “TimeInfo” is displayed, and press ENTER.
- Use the UP or DOWN buttons to find the time information you would like to check. Press the ENTER button to access your desired time information.
- To clear the current running time, press the UP or DOWN buttons until “TimerPin” is displayed, and press ENTER. Use the UP or DOWN buttons to put in the “Clear” password “050”, a press ENTER. Use the UP or DOWN buttons to select “ON”, and press ENTER. After doing this, unplug the fixture, then plug it back in. The current running time should now be cleared.
- Press the MODE button to exit and return to the “Infor” menu. Press MODE again to exit and return to the main menu.
Temperature Infomation – In this submenu you are able to check the fixture’s current running temperature.
- Plug the fixture in and press the UP or DOWN buttons until “Info” is displayed.
- Press the ENTER button and press the UP or DOWN buttons until “TempInfo” is displayed, and press ENTER.
- Use the UP or DOWN buttons to find the time information you would like to check. Press the ENTER button to access your desired time information.
Software Infomation – In this submenu you are able to check the fixture’s current software.
- Plug the fixture in and press the UP or DOWN buttons until “Info” is displayed.
- Press the ENTER button and press the UP or DOWN buttons until “Software” is displayed, and press ENTER. The current software version will now be displayed. Press the MODE button to exit.
Manual Dimmer Mode:
- Plug the fixture in and press the UP or DOWN buttons until “Menu Manual” is displayed and press ENTER.
- After pressing ENTER, “ManCtrl Dimmer” will be displayed. Press the ENTER button to access the dimmer adjustment submenu.
- Once you have entered the dimmer adjustment submenu, use the UP and DOWN buttons to adjust the dimmer intensity. When you are finished adjusting the intensity, press ENTER.
- Press the UP or DOWN buttons to switch “ManCtrl Strobe” and press ENTER. Follow the values listed under the DMX STROBE channel. These values will match with the values in Strobe control.
Primary-Secondary Configuration
Primary-Secondary Configuration:This function will allow you to link units together to run in a Primary-Secondary set-up. In this type of set up one unit will act as the controlling unit and the others will react to the controlling unit’s built-in programs. Any unit can act as a Primary or as a Secondary, however, only one unit can be programmed to act as the “Primary.”Primary-Secondary Connections and Settings:
- Daisy chain your units via the XLR connector on the rear of the unit. Use standard XLR data cables to link your units together. Remember that the Male XLR connector is the input and the Female XLR connector is the output. The first unit in the chain (primary) will use the female XLR connector only. The last unit in the chain will use the male XLR connector only.
- Connect the first “Secondary” unit to the “Primary.”
- Set the “Primary” unit to your desired mode of operation. On the “Secondary” unit’s press the UP or DOWN buttons until “Function” is displayed, and press ENTER.
- Press the UP or DOWN buttons until “Disp. Set” is displayed and press ENTER. Press the UP or DOWN buttons until “Secondary” is displayed and press ENTER.
- The “Secondary” unit(s) will now follow the “Primary”.
- To exit “Secondary” mode, press the MODE button.
- To fully exit “Secondary” mode, you will need to follow steps 3 and 4 and set the display to “ADDR” and press ENTER.
Zoom Adjustment Knob
DMX Traits
Mode/Channel | Value | Function | |||||
1CH | 2CH | 2-2CH | 3CH | 2-3CH | 4CH | ||
1 | 1 | 1 | 1 | 1 | 1 | 0-255 | Dimmer Master Dim |
2 | 2 | 2 | 0-255 | Dimmer Fine 16bit | |||
2 | 2 | 3 | Strobe | ||||
0-31 | OFF | ||||||
32-63 | ON | ||||||
64-95 | Variable Strobe slow to fast | ||||||
96-127 | ON | ||||||
128-159 | Pulse Effect slow to fast | ||||||
160-191 | ON | ||||||
192-223 | Random Strobe slow to fast | ||||||
224-255 | ON | ||||||
3 | 3 | 4 | Dim Mode | ||||
0-20 | Standard | ||||||
21-40 | Stage | ||||||
41-60 | TV | ||||||
61-80 | Architectural | ||||||
81-100 | Theatre | ||||||
101-120 | Stage 2 | ||||||
121-255 | Default to Unit Setting |
Multiple Unit Power Linking
With this feature, you can connect the fixtures to one another using the PowerCON input and output sockets. The maximum that can be connected is 20 fixtures @ 120V and 40 fixtures @ 240V. After the maximum connected fixtures, you will need to use a new power outlet.NOTE: USE CAUTION WHEN POWER LINKING OTHER FIXTURES TO THE ENCORE FR50Z AS THE POWER CONSUMPTION OF OTHER LIGHTING FIXTURES WILL VARY!
Dimmer Curve Chart
Rise Time (ins) | Dow n Time (ins) | Rise Time (Ins) | Down Time (ins) | |
Standard (default) | 0 | 0 | 0 | 0 |
Stage | 780 | 1100 | 1540 | 1660 |
TV | 1180 | 1520 | 1860 | 1940 |
Architectural | 1380 | 1730 | 2040 | 2120 |
Theatre | 1580 | 1940 | 2230 | 2280 |
Stage 2 | 0 | 1100 | 0 | 1660 |
Barn Door Attachment
Dimensional Drawings
Trouble Shooting
Listed below are a few common problems the user may encounter, with solutions.Unit not responding to DMX:
- Check that the DMX cables are connected properly and are wired correctly (pin 3 is “hot”; on some other DMX devices pin 2 may be ‘hot’). Also, check that all cables are connected to the right connectors; it does matter which way the inputs and outputs are connected.
Cleaning
Due to fog residue, smoke, and dust cleaning the internal and external optical lenses must be carried out periodically to optimize light output.
- Use normal glass cleaner and a soft cloth to wipe down the outside casing.
- Clean the external optics with a glass cleaner and a soft cloth every 20 days.
- Always be sure to dry all parts completely before plugging the unit back in.
Cleaning frequency depends on the environment in which the fixture operates (i.e. smoke, fog residue, dust, dew).
Warranty
MANUFACTURER’S LIMITED WARRANTYA. ADJ Products, LLC hereby warrants, to the original purchaser, ADJ Products, LLC products to be free of manufacturing defects in material and workmanship for a prescribed period from the date of purchase (see specific warranty period on reverse). This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories. It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought.B. For warranty service you must obtain a Return Authorization number (RA#) before sending back the product–please contact ADJ Products, LLC Service Department at 800-322-6337. Send the product only to the ADJ Products, LLC factory. All shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, ADJ Products, LLC will pay return shipping charges only to a designated point within the United States. If the entire instrument is sent, it must be shipped in it’s original package. No accessories should be shipped with the product. If any accessories are shipped with the product, ADJ Products, LLC shall have no liability whatsoever for loss of or damage to any such accessories, nor for the safe return thereof.C. This warranty is void if the serial number has been altered or removed; if the product is modified in any manner which ADJ Products, LLC concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the ADJ Products, LLC factory unless prior written authorization was issued to purchaser by ADJ Products, LLC; if the product is damaged because not properly maintained as set forth in the instruction manual.D. This is not a service contract, and this warranty does not include maintenance, cleaning or periodic check-up. During the period specified above, ADJ Products, LLC will replace defective parts at its expense with new or refurbished parts and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of ADJ Products, LLC under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of ADJ Products, LLC. All products covered by this warranty were manufactured after August 15, 2012, and bear indentifying marks to that effect.E. ADJ Products, LLC reserves the right to make changes in design and/or improvements upon its products without any obligation to include these changes in any products theretofore manufactured. No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with products described above. Except to the extent prohibited by applicable law, all implied warranties made by ADJ Products, LLC in connection with this product, including warranties of merchantability or fitness,are limited in duration to the warranty period set forth above. And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said period has expired. The consumer’s and/or Dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall ADJ Products, LLC be liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product. This warranty is the only written warranty applicable to ADJ Products, LLC Products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.MANUFACTURER’S LIMITED WARRANTY PERIODS:
- Non-L.E.D. Lighting Products = 1-year (365 days) Limited Warranty (Such as Special Effect Lighting, Intelligent Lighting, UV lighting, Strobes, Fog Machines, Bubble Machines, Mirror Balls, Par Cans, Trussing, Lighting Stands, etc. excluding LED and lamps)
- Laser Products = 1 Year (365 Days) Limited Warranty (excluding laser diodes which have a 6-month limited warranty)
- L.E.D. Products = 2-year (730 days) Limited Warranty (excluding batteries which have a 180-day limited warranty). Note: 2 Year Warranty only applies to purchases within the United States.
- StarTec Series = 1 Year Limited Warranty (excluding batteries that have a 180-day limited warranty).
- ADJ DMX Controllers = 2 Year (730 Days) Limited Warranty
Specifications
Model: Encore FR50z
Voltage:100V ~ 240V/50~60HzLEDs: 1 x 50W LEDColor Temperature: 3000kBeam Angle: 14~30 DegreesWorking Position: Any safe working positionPower Draw: 50WPower Linking: 20 Fixtures Max. @ 120V 40 Fixtures Max. @ 230VFuse:1AWeight: 9.5 lbs./ 4.3 Kgs. (w/ Barn Door)8.5 lbs./ 3.8 Kgs. (w/o Barn Door)Dimensions: With Barn Doors:13.38” (L) x 9.37” (W) x 11.74” (H)339.8 x 238.05 x 298.25mmWithout Barn Doors:9.17” (L) x 9.37” (W) x 11.74” (H)232.8 x 238.05 x 298.25mmColors: Warm WhiteDMX Channels: 6 DMX Modes: 1/2/2-2/3/2-3/4Control: RDM (Remote Device Management)Warranty: 2 Year (730 days)
Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice.
ADJ Products, LLC6122 S. Eastern Ave. Los Angeles, CA 90040 USATel: 323-582-2650 / Fax: 323-725-6100Web: www.adj.com / E-mail: [email protected]A.D.J. Supply Europe B.V.Junostraat 26468 EW KerkradeNetherlands[email protected] / www.adj.euTel: +31 45 546 85 00 / Fax: +31 45 546 85 99Follow us on: