ADTRAN Total Access 600R 3rd Gen Gateway User Guide

Total Access 600R 3rd Gen Gateway

TOTAL ACCESS 600 SERIESSystem ManualTotal Access 600R Total Access 604 Total Access 608 Total Access 612 Total Access 616 Total Access 62461200624L1-1B June 2004

Trademarks

Total Access 600 Series System Manual

TrademarksAny brand names and product names included in this manual are trademarks, registered trademarks, or trade names of their respective holders.Total Access® is a registered trademark of ADTRAN, Inc.

To the Holder of the ManualThe contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice.In no event will ADTRAN be liable for any special, incidental, or consequential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this publication.

About this ManualThis manual provides a complete description of the Total Access 6XX system and system software. The purpose of this manual is to provide the technician, system administrator, and manager with general and specific information related to the planning, installation, operation, and maintenance of the Total Access 6XX. This manual is arranged so that needed information can be quickly and easily found.

901 Explorer Boulevard P.O. Box 140000Huntsville, AL 35814-4000 Phone: (256) 963-8000© 2004 ADTRAN, Inc. All Rights Reserved. Printed in U.S.A.

2

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Revision History

Revision HistoryDocument Revision A B

Date October 2002May 2004

Description of Changes Initial Release Updated to include menu changes for firmware release.

Conventions

Notes provide additional useful information.

Cautions signify information that could prevent service interruption.Warnings provide information that could prevent damage to the equipment or endangerment to human life.

61200624L1-1B

© 2004 ADTRAN, Inc.

3

Safety Instructions

Total Access 600 Series System Manual

Safety InstructionsWhen using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or personal injury:1. Do not use this product near water, such as a bathtub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool.2. Avoid using a telephone (other than a cordless-type) during an electrical storm. There is a remote risk of shock from lightning.3. Do not use the telephone to report a gas leak in the vicinity of the leak.4. Use only the power cord, power supply, and/or batteries indicated in the manual. Do not dispose of batteries in a fire. They may explode. Check with local codes for special disposal instructions.

Save These Important Safety Instructions

4

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

FCC-Required Information

FCC-Required Information

FCC regulations require that the following information be provided in this manual:1. This equipment complies with Part 68 of FCC rules and requirements adopted by ACTA. On the equipment housing is a label that contains, among other information, a product identifier in the format US: AAAEQ##TXXXX. If requested, provide this information to the telephone company.2. If this equipment causes harm to the telephone network, the telephone company may temporarily discontinue service. If possible, advance notification is given; otherwise, notification is given as soon as possible. The telephone company will advise the customer of the right to file a complaint with the FCC.3. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the proper operation of this equipment. Advance notification and the opportunity to maintain uninterrupted service are given.4. 4.If experiencing difficulty with this equipment, please contact ADTRAN for repair and warranty information. The telephone company may require this equipment to be disconnected from the network until the problem is corrected or it is certain the equipment is not malfunctioning.5. This unit contains no user-serviceable parts.6. An FCC compliant telephone cord with a modular plug is provided with this equipment. This equipment is designed for connection to the telephone network or premises wiring using an FCC compatible modular jack, which is compliant with Part 68 and requirements adopted by ACTA.7. The following information may be required when applying to your local telephone company for leased line facilities.

Product ListingTA 600/604/608 Series T1 ProductsTA 612/616/624 Series T1 ProductsTA 600 Series SDSL, SHDSL ProductsTA 600 Series ADSL Products

Registration Number US:HDCDENAN4213680L1 US: HDCDENAN4213616L1

Service Type1.544 Mbps – SF 1.544 Mbps – SF and B8ZS 1.544 Mbps – ESF 1.544 Mbps – ESF and B8ZS

REN/SOC 6.0N

HDCUSA-44560-OT-N

Analog Loop Start/Ground Start 0.1B/9.0F

US:HDCDL02B4200644L1

Analog Loop Start/Ground Start ADSL Service

0.1B/9.0F 0.2B/9.0F

FIC04DU9-BN 04DU9-DN 04DU9-1KN 04DU9-1SN02LS2 02GS202LS2 02GS202LS2

USOC RJ-48C RJ-11C RJ-11C

8. The REN is useful in determining the quantity of devices you may connect to your telephone line and still have all of those devices ring when your number is called. In most areas, the sum of the RENs of all devices should not exceed five. To be certain of the number of devices you may connect to your line as determined by the REN, call your telephone company to determine the maximum REN for your calling area.9. This equipment may not be used on coin service provided by the telephone company. Connection to party lines is subject to state tariffs. Contact your state public utility commission or corporation commission for information.

61200624L1-1B

© 2004 ADTRAN, Inc.

5

FCC-Required Information

Total Access 600 Series System Manual

Federal Communications Commission Radio Frequency Interference StatementThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio frequencies. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Shielded cables must be used with this unit to ensure compliance with Class A FCC limits.

Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

6

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Affidavit Requirements for Connection to Digital Services

Affidavit Requirements for Connection to Digital Services· An affidavit is required to be given to the telephone company whenever digital terminal equipment without encoded analog content and billing protection is used to transmit digital signals containing encoded analog content which are intended for eventual conversion into voice band analog signal and transmitted on the network.· The affidavit shall affirm that either no encoded analog content or billing information is being transmitted or that the output of the device meets Part 68 encoded analog content or billing protection specifications.· End user/customer will be responsible to file an affidavit with the local exchange carrier when connecting unprotected CPE to a 1.544 Mbps or subrate digital service.· Until such time as subrate digital terminal equipment is registered for voice applications, the affidavit requirements for subrate services are waived.

61200624L1-1B

© 2004 ADTRAN, Inc.

7

Affidavit Requirements for Connection to Digital Services

Total Access 600 Series System Manual

AFFIDAVIT FOR CONNECTION OF CUSTOMER PREMISES EQUIPMENT TO 1.544 MBPS AND/OR SUBRATE DIGITAL SERVICESFor the work to be performed in the certified territory of ___________________ (telco name) State of ________________ County of ________________ I, _______________________ (name), ____________________________________ (business address), ____________________ (telephone number) being duly sworn, state: ( ) I have responsibility for the operation and maintenance of the terminal equipment to be connected to 1.544 Mbpsand/or ________ subrate digital services. The terminal equipment to be connected complies with Part 68 of the FCC rules except for the encoded analog content and billing protection specifications. With respect to encoded analog content and billing protection: ( ) I attest that all operations associated with the establishment, maintenance, and adjustment of the digital CPE with respect to analog content and encoded billing protection information continuously complies with Part 68 of the FCC Rules and Regulations. ( ) The digital CPE does not transmit digital signals containing encoded analog content or billing information which is intended to be decoded within the telecommunications network. ( ) The encoded analog content and billing protection is factory set and is not under the control of the customer. I attest that the operator(s)/maintainer(s) of the digital CPE responsible for the establishment, maintenance, and adjustment of the encoded analog content and billing information has (have) been trained to perform these functions by successfully having completed one of the following (check appropriate blocks): ( ) A. A training course provided by the manufacturer/grantee of the equipment used to encode analog signals;or ( ) B. A training course provided by the customer or authorized representative, using training materials andinstructions provided by the manufacturer/grantee of the equipment used to encode analog signals; or ( ) C. An independent training course (e.g., trade school or technical institution) recognized by themanufacturer/grantee of the equipment used to encode analog signals; or ( ) D. In lieu of the preceding training requirements, the operator(s)/maintainer(s) is (are) under the control of asupervisor trained in accordance with _________ (circle one) above.I agree to provide ______________________ (telco’s name) with proper documentation to demonstrate compliance with the information as provided in the preceding paragraph, if so requested. _________________________________Signature _________________________________Title _________________________________ Date Transcribed and sworn to before me This ________ day of _______________, ________________________________________ Notary PublicMy commission expires: _________________________________

8

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Industry Canada Compliance Information

Industry Canada Compliance InformationThe Industry Canada Certification label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department of Commerce does not guarantee the equipment will operate to the user’s satisfaction.Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic waterpipe system, if present, are connected together. This precaution may be particularly important in rural areas.

Users should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or an electrician, as appropriate.

The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the equipment that the total of the LNs of all devices does not exceed 100. The ringer equivalence number (REN) assigned to each terminal adapter is used to determine the total number of devices that may be connected to each circuit. The sum of the RENs from all devices in the circuit should not exceed a total of 5.0.Canadian Emissions RequirementsThis digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus,” ICES-003 of the Department of Communications. Cet appareil numérique respecte les limites de bruits radioelectriques applicables aux appareils numériques de Class A prescrites dans la norme sur le materiel brouilleur: “Appareils Numériques,” NMB-003 edictee par le ministre des Communications.

61200624L1-1B

© 2004 ADTRAN, Inc.

9

Product Warranty

Total Access 600 Series System Manual

Product WarrantyADTRAN will repair and return this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty.

Product RegistrationRegistering your product helps ensure complete customer satisfaction. Please take time to register your products online at www.adtran.com. Click Service and Support on the top of the page, and then click Product Registrationunder Support.

Customer Service, Product Support Information, and TrainingADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty. A return material authorization (RMA) is required prior to returning equipment to ADTRAN. For service, RMA requests, training, or more information, use the contact information given below.Repair and ReturnIf you determine that a repair is needed, please contact our Customer and Product Service (CAPS) department to have an RMA number issued. CAPS should also be contacted to obtain information regarding equipment currently in house or possible fees associated with repair.

CaPS Department

(256) 963-8722

Identify the RMA number clearly on the package (below address), and return to the following address:

ADTRAN Customer and Product Service 901 Explorer Blvd. (East Tower) Huntsville, Alabama 35806RMA # _____________

Pre-Sales Inquiries and Applications SupportYour reseller should serve as the first point of contact for support. If additional pre-sales support is needed, the ADTRAN Support web site provides a variety of support services such as a searchable knowledge base, latest product documentation, application briefs, case studies, and a link to submit a question to an Applications Engineer. All of this, and more, is available at:

http://support.adtran.com

When needed, further pre-sales assistance is available by calling our Applications Engineering Department.

Applications Engineering (800) 615-1176

10

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual Customer Service, Product Support Information, and Training

Post-Sale SupportYour reseller should serve as the first point of contact for support. If additional support is needed, the ADTRAN Support web site provides a variety of support services such as a searchable knowledge base, updated firmware releases, latest product documentation, service request ticket generation and trouble-shooting tools. All of this, and more, is available at:

http://support.adtran.com

When needed, further post-sales assistance is available by calling our Technical Support Center. Please have your unit serial number available when you call.

Technical Support (888) 4ADTRAN

Installation and Maintenance SupportThe ADTRAN Custom Extended Services (ACES) program offers multiple types and levels of installation and maintenance services which allow you to choose the kind of assistance you need. This support is available at:

http://www.adtran.com/aces

For questions, call the ACES Help Desk.

ACES Help Desk (888) 874-ACES (2237)

TrainingThe Enterprise Network (EN) Technical Training Department offers training on our most popular products. These courses include overviews on product features and functions while covering applications of ADTRAN’s product lines. ADTRAN provides a variety of training options, including customized training and courses taught at our facilities or at your site. For more information about training, please contact your Territory Manager or the Enterprise Training Coordinator.

Training Phone Training Fax Training Email

(800) 615-1176, ext. 7500 (256) 963-6700 training@adtran.com

61200624L1-1B

© 2004 ADTRAN, Inc.

11

Customer Service, Product Support Information, and Training Total Access 600 Series System Manual

12

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System ManualTable of Contents

Table of Contents

Section 1 System Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15This section provides an overview of the Total Access 600 Series system.

Section 2

Engineering Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21This section provides equipment dimensions, power requirements, front panel design, rear panel design, LEDs, and at-a-glance specifications.

Section 3

Network Turnup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35This section provides shipment contents list, grounding instructions, mounting options, and specifics of supplying power to the unit.

Section 4

User Interface Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41This section of ADTRAN’s Total Access 600 Series System Manual is designed for use by network administrators and others who will configure and provision the system. It contains information about navigating the VT100 user interface, configuration information, and menu descriptions.

Section 5

Detail Level Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 183DLP-1 Connecting a VT100 Terminal or PC to the CRAFT Port . . . . . . . . . . . . . . . . . . . . . 185 DLP-2 Logging in to the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 DLP-3 Setting IP Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 DLP-4 Verifying Communications Over an IP LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191 DLP-5 Connecting to the Unit Using Telnet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 DLP-6 Adding/Removing Users and Changing Password Security Levels . . . . . . . . . . . . . . 199 DLP-7 Updating the Firmware using TFTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 DLP-8 Updating the Firmware using XMODEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 DLP-9 Saving the Current Configuration Using TFTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 209 DLP-10 Loading a Configuration Using TFTP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 211 DLP-11 Saving and Transferring a Current Configuration Using XMODEM. . . . . . . . . . . . . 213 DLP-12 Loading a Configuration Using XMODEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215 DLP-13 Saving and Loading Text Configuration using Terminal Command Line . . . . . . . . . 217 DLP-14 A.03 to A.04 Firmware Upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 DLP-15 Using the ADTRAN Utility Syslog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223 DLP-16 Executing Terminal Mode Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 DLP-17 Configuring Dual T1 Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 DLP-18 Unit Installation Using the Auto-Config Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . 235 DLP-19 TDM to ATM Upgrade . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239

Section 6

ADTRAN Utilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243This section provides instructions for configuring and using the ADTRAN Utilities software programs including Telnet, VT100, Syslog, and TFTP.

Section 7

MIBs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253This section is divided into two parts: (1) SNMP information for TDM units and (2) SNMP information for ATM units. Each section details the Management Information Bases (MIBs) supported, MIB Compilation Order, Traps Supported, and MIB Variables supported.

61200624L1-1B

© 2004 ADTRAN, Inc.

13

Table of Contents

Total Access 600 Series System Manual

14

© 2004 ADTRAN, Inc.

61200624L1-1B

SYSTEM DESCRIPTIONThis section provides an overview of the Total Access 600 Series system.CONTENTSSystem Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Configuration and Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Software Upgradeable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Network Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Integrated Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 ATM Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Frame Relay Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Analog Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 V.35 DTE Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Routing Capability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Performance Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19IAD Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 T1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 ADSL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 SDSL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 SHDSL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

61200624L1-1B

© 2004 ADTRAN, Inc.

15

Section 1 System Description

Total Access 600 Series System Manual

1. SYSTEM OVERVIEWThe Total Access 600 Series contains Integrated Access Devices (IAD) designed for cost-effective deployment of voice and data services at the customer premises. The Total Access 600 Series benefits integrated communications providers (such as CLECs, ILECs, and ISPs) who require a customer premises device with integrated voice and data functions, and provides a viable migration path from TDM to packet-based technology. These IADs support applications such as VoDSL and VoATM.The Total Access 600 Series features remote management, built-in IP router, and an optional DSX-1 interface (factory installed only). An optional battery backup is also available for many of the models. The units include a Nx56/64 V.35 interface, 10/100BaseT interface, FXS ports, and network interfaces (T1, ADSL, SDSL, and SHDSL). The last two digits of the product name indicate the number of on-board FXS ports. The Total Access 604 contains four FXS ports, the Total Access 608 contains eight FXS ports, etc. The units can provision, test, and provide status for any of the voice and data interfaces. All connections are made via the rear panel.This line of IADs includes both the ATM and TDM versions of the Total Access 604/608/612/616/624 and Total Access 600R systems. Until now, the Total Access TDM units have been running firmware version A.03.XX. Recently, A.04.XX has been released to support the TDM Total Access IADs. The development of A.04.XX code is a significant step in the evolution of the Total Access product line, as it allows all Total Access family members to share the same base code. This means that features and fixes are more easily implemented and are propagated across the product line. The User Interface Guide section of this manual represents the A.04 firmware changes. There are two possible upgrade paths: (1) Upgrading from A.03 to A.04 directly and; (2) Upgrading from A.03 to A.03.92 (Transition Build) to A.04.Upgrading from A.03 to A.03.92 (Transition Build) to A.04 will save the unit’s configuration. Upgrading from A.03 to A.04 directly (or from A.04 to A.03 directly) will erase the unit’s configuration. See DLP-14, A.03 to A.04 Firmware Upgrade, for more details.Units manufactured after October 2002 will not be compatible with some older versions of Total Access 612, 616, and 624 software. Refer to the following information if an older version of software is to be loaded into the unit. For TDM applications, please use software revision A.03.58 or later. For ATM applications, software revision D.01.30 or later is required. Using incompatible software will cause the unit to malfunction. For more information or technical assistance, please call ADTRAN Technical Support at 888-4ADTRAN. Please have the unit serial number available when contacting Technical Support.

16

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 1 System Description

2. FEATURES AND BENEFITSThe following list gives Total Access 600 Series features and benefits. Some features are model-dependent.Configuration and Management· VT100 Emulation · SNMP Management · Telnet · Six levels of password protection and privileges for Telnet access · Support for VoDSL gateway management systems and firmware downloadSoftware Upgradeable· Flash memory · TFTP download · XMODEM via CRAFT portNetwork Interfaces· T1 · ADSL · SDSL · SHDSLIntegrated Components· IP router · Life-line voice backup (xDSL models only) · Network connection · 10/100 BaseT connection · V.35 Nx56/64 DTE interface · CRAFT port · Optional DSX-1 port (Factory installed only)ATM Support· AAL2 (voice), AAL5 (data, voice) · 6 PVCs (1 voice, 5 data) · RFC 1483 (multi protocol over ATM) · PPPoA (RFC 2364) · QoS Support: VBR-rt (voice), UBR (data) · I.610 F5 OAM loopback · G.165/G.168 echo cancellation, 8 ms echo tail · Voice Codes: PCM (G.711), 32k ADPCM (G.726) · Idle channel suppression

61200624L1-1B

© 2004 ADTRAN, Inc.

17

Section 1 System Description

Total Access 600 Series System Manual

Frame Relay Support· Copper Mountain CE fragmentation support · Annex A, Annex D, and LMI support (T1) · FRF.5 and FRF.8 support (V.35)

Analog Ports· Analog FXS ports per TR-57, 50-Pin Amp (number of ports is unit dependent) · Supports popular CLASSTM features · Modes: FXS Loop Start, FXS Ground Start, TR08 Single, TR08 UVG, DP0, Tandem (E&M) · Assured DialtoneTM Lifeline POTS port (available only xDSL models) · Balanced ringing, 5 REN per port not to exceed 35 REN · Fixed ringer ­ 70 Vrms with 20 VDC offset · Distance up to 1000 feet

V.35 DTE Interface· Data Rate: Nx56 or Nx64 kbps (N=1 to 24) · Electrical and Mechanical: CCITT V.35, 34-pin · Frame Relay (FRF.5, FRF.8 capable)

Routing Capability· Ethernet: 10/100BaseT (RJ-45) · IEEE 802.3 and 802.1D (MAC Bridging) · IP Support: TCP, RIP V1, RIP V2, UDP, ICMP, ARP, UDP Relay, SYSLOG · PPP Support: LCP, IPCP, BCP · DHCP Server to LAN, DHCP from network · Copper Mountain Compatible · Frame Relay (Annex A, Annex D, LMI, Static)

Security· PAP, CHAP, and EAP for PPP · Radius authentication for Telnet access · NAT with multi-point to single-point · Future support of NAT multi-point to multi-point · Filtering (Pattern, IP, Bridge) · Password protection

Testing· Local/Remote loopbacks · Line and payload loopback tests · FXO tests (Total Access 624 with FXO only) · FXS tests

18

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 1 System Description

Performance Monitoring· Reports: Information stored for last 24 hours in 15 minute increments · Performance statistics per TR54016, T1.403, RFC1406 · Alarm reporting per TR54016, T1.403

3. IAD SYSTEMSThe Total Access 600 Series supports a variety of WAN technologies. The following list displays the various available systems grouped by network technology.T1· P/N 4200600L1#TDM Total Access 600R T1 TDM · P/N 4213600L1#TDM Total Access 600R T1 TDM with DSX-1 · P/N 4200600L1#ATM Total Access 600R T1 ATM · P/N 4213600L1#ATM Total Access 600R T1 ATM with DSX-1 · P/N 4203640L1#TDM Total Access 604 T1 TDM · P/N 4213640L1#TDM Total Access 604 T1 TDM with DSX-1 · P/N 4203640L1#TDMB Total Access 604 T1 TDM with Battery Backup · P/N 4203640L1#ATM Total Access 604 T1 ATM · P/N 4213640L1#ATM Total Access 604 T1 ATM with DSX-1 · P/N 4203640L1#ATMB Total Access 604 T1 ATM with Battery Backup · P/N 4203680L1#TDM Total Access 608 T1 TDM · P/N 4213680L1#TDM Total Access 608 T1 TDM with DSX-1 · P/N 4203680L1#TDMB Total Access 608 T1 TDM with Battery Backup · P/N 4203680L1#ATM Total Access 608 T1 ATM · P/N 4213680L1#ATM Total Access 608 T1 ATM with DSX-1 · P/N 4203680L1#ATMB Total Access 608 T1 ATM with Battery Backup · P/N 4203612L1#TDM Total Access 612 T1 TDM · P/N 4213612L1#TDM Total Access 612 T1 TDM with DSX-1 · P/N 4203612L1#ATM Total Access 612 T1 ATM · P/N 4213612L1#ATM Total Access 612 T1 ATM with DSX-1 · P/N 4203616L1#TDM Total Access 616 T1 TDM · P/N 4213616L1#TDM Total Access 616 T1 TDM with DSX-1 · P/N 4203616L1#ATM Total Access 616 T1 ATM · P/N 4213616L1#ATM Total Access 616 T1 ATM with DSX-1 · P/N 4203624L1#TDM Total Access 624 T1 TDM · P/N 4213624L1#TDM Total Access 624 T1 TDM with DSX-1 · P/N 4203624L3#TDM Total Access 624 T1 TDM with 16 FXS and 8 FXO · P/N 4213624L3#TDM Total Access 624 T1 TDM with DSX-1, 16 FXS, and 8 FXO · P/N 4203624L1#ATM Total Access 624 T1 ATM · P/N 4213624L1#ATM Total Access 624 T1 ATM with DSX-1

61200624L1-1B

© 2004 ADTRAN, Inc.

19

Section 1 System Description

Total Access 600 Series System Manual

ADSL· P/N 4200644L1 Total Access 604 ADSL · P/N 4200644L1#ACB Total Access 604 ADSL with Battery Backup · P/N 4200684L1 Total Access 608 ADSL · P/N 4200684L1#ACB Total Access 608 ADSL with Battery BackupSDSL· P/N 4200642L1 Total Access 604 SDSL · P/N 4200642L1#ACB Total Access 604 SDSL with Battery Backup · P/N 4200682L1 Total Access 608 SDSL · P/N 4200682L1#ACB Total Access 608 SDSL with Battery Backup · P/N 4200612L2 Total Access 612 SDSL · P/N 4200616L2 Total Access 616 SDSL · P/N 4200624L2 Total Access 624 SDSLSHDSL· P/N 4200600L3 Total Access 600R SHDSL · P/N 4200643L1 Total Access 604 SHDSL · P/N 4200643L1#ACB Total Access 604 SHDSL with Battery Backup · P/N 4200683L1 Total Access 608 SHDSL · P/N 4200683L1#ACB Total Access 608 SHDSL with Battery Backup · P/N 4200612L3 Total Access 612 SHDSL · P/N 4200616L3 Total Access 616 SHDSL · P/N 4200624L3 Total Access 624 SHDSL

20

© 2004 ADTRAN, Inc.

61200624L1-1B

ENGINEERING GUIDELINESThis section provides equipment dimensions, power requirements, front panel design, rear panel design, LEDs, and at-a-glance specifications.CONTENTSEquipment Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Total Access 600R, Total Access 604/608 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Total Access 612/616/624. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Reviewing the Front Panel Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Total Access 600R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Total Access 604/608 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Total Access 612/616/624. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Reviewing the Rear Panel Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 VOICE Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 NTWK Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 CRAFT Port. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 10/100BaseT Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 V.35 Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Battery Backup Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 AC Power Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 Life Line Analog Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 DSX-1 Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32At-A-Glance Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

FIGURESFigure 1. Total Access 600R Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Figure 2. Total Access 604/608 Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Figure 3. Total Access 612/616/624 Front Panel Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Figure 4. Total Access 600R Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Figure 5. Total Access 604/608 Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Figure 6. Total Access 604/608 Rear Panel with Optional Life Line POTS . . . . . . . . . . . . . . . . . 28 Figure 7. Total Access 604/608 Rear Panel with Optional DSX-1 Interface . . . . . . . . . . . . . . . . . 28 Figure 8. Total Access 612/616/624 Rear Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Figure 9. Total Access 612/616/624 Rear Panel with Optional Life Line POTS . . . . . . . . . . . . . . 28 Figure 10. Total Access 612/616/624 Rear Panel with Optional DSX-1 Interface . . . . . . . . . . . . . 28 Figure 11. VOICE Connector Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Table 1. Table 2. Table 3. Table 4. Table 5. Table 6. Table 7. Table 8. Table 9.

TABLESAC Power Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Total Access 600R Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Total Access 604/608 TDM Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Total Access 6XX ATM Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Total Access 612/616/624 TDM Front Panel LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 NTWK Connection Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 CRAFT Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 DB-9 to RJ-48 Adapter Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Ethernet Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

61200624L1-1B

© 2004 ADTRAN, Inc.

21

Section 2 Engineering Guidelines

Total Access 600 Series System Manual

Table 10. Table 11. Table 12. Table 13.

V.35 Winchester Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 LIFE LINE Connection Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 DSX-1 Connection Pinout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

22

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 2 Engineering Guidelines

1. EQUIPMENT DIMENSIONS

Total Access 600R, Total Access 604/608The Total Access 600R and Total Access 604/608systems measure 11.25″ W, 7.5″ D, and 2″ H and come equipped for table top or wallmount use.

Total Access 612/616/624The Total Access 612/616/624 systems measure 17″ W, 8.5″ D, and 1.75″ H and come equipped for table top or wallmount use. These systems may be utilized in 19- or 23-inch racks with the purchase of mounting brackets (19″­ P/N 1200627L1 and 23″­ P/N 1200627L2).

2. POWER REQUIREMENTS

The following power requirements apply:

Table 1. AC Power Requirements

System Total Access 600R Total Access 604 Total Access 608 Total Access 612 Total Access 616 Total Access 624

Maximum Power Consumption 14 W 14 W 17 W 28 W 32 W 40 W

Maximum Current Draw 300mA 300 mA 300 mA 1.3 A 1.3 A 1.3 A

3. REVIEWING THE FRONT PANEL DESIGN Total Access 600RFigure 2 shows the Total Access 600R front panel.

LAN

WAN

Figure 1. Total Access 600R Front Panel Layout

61200624L1-1B

© 2004 ADTRAN, Inc.

23

Section 2 Engineering Guidelines

Total Access 600 Series System Manual

Front Panel LEDsThe front panel provides five status LEDs to monitor operation and activity. Table 3 provides LED descriptions for Total Access 600R systems.

For these LEDs…

Table 2. Total Access 600R Front Panel LEDs

This color light…

Indicates that…

LAN TX/RX LAN LINK WAN STAT WAN ERRPWR

Off Green (blinking) OffGreen (solid) Red (solid) Yellow (solid) Green (solid) Off Red (solid) Red (flashing) Yellow (solid) Green (solid) Off

there is no data traffic on the LAN. there is data traffic on the LAN. the physical link is down; there is no Ethernet connection. there is link integrity on the LAN (physical link is up). the T1 is in red alarm or T1 sync loss has occurred. the T1 is in yellow alarm. the unit is not in alarm. the WAN link is up and error-free. severe errors are present on the WAN link. the T1 is down. errors are present on the WAN link. power is supplied to the unit. power is not supplied to the unit.

Total Access 604/608The front panels of the Total Access 604/608 systems are identical. Figure 2 shows the Total Access 608 front panel as a representative of both models.

Figure 2. Total Access 604/608 Front Panel Layout

24

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 2 Engineering Guidelines

Front Panel LEDsThe front panel provides eight status LEDs to monitor operation and activity. The LED functionality varies based on product and software load (TDM versus ATM). Table 3 provides LED descriptions for Total Access 604/608 systems employing TDM software, and Table 4 on page 26 lists ATM software LED functionality.

For these LEDs…

Table 3. Total Access 604/608 TDM Front Panel LEDs

This color light…

Indicates that…

TX/RX LINK V.35 RX V.35 TX DATA VOICE BATTPWR NET

Off

there is no data traffic on the LAN.

Green (blinking)

there is data traffic on the LAN.

Off

the physical link is down; there is no Ethernet

connection.

Green (solid)

there is link integrity on the LAN (physical link is up).

Off

no data traffic is being received on the V.35.

Green (blinking)

data is being received on the V.35.

Off

no data traffic is being transmitted on the V.35.

Green (blinking)

data is being transmitted on the V.35.

Red (solid)

the T1 is in red alarm or T1 sync loss has occurred.

Yellow (solid)

the T1 is in test.

Green (solid)

Layer 2 is up.

Off

the T1 is down.

Green (blinking)

the phone is off hook.

Green (solid)

the T1 is up and the phone is on hook.

Off

there is no power connected to the system.

Green (solid)

AC power is operational and battery is functional.

Red/Green (alternating) AC power is operational, but the battery is not functional.

Amber (solid)

AC power has failed and the battery is functional.

Red/Amber (alternating) AC power has failed and the battery is not functional.

Green (solid)

Layer 1 is up.

Green (blinking)

Layer 1 is down.

61200624L1-1B

© 2004 ADTRAN, Inc.

25

Section 2 Engineering Guidelines

Total Access 600 Series System Manual

Table 4. Total Access 6XX ATM Front Panel LEDs

For these LEDs… This color light…

Indicates that…

TX/RXLINKV.35 RXV.35 TXDATAVOICEVOICE(if Gateway is Jetstream)VOICE(if Gateway is Coppercom or LES-CAS)VOICE(if Gateway is Tollbridge)VOICE(if no Gateway)BATTPWR NET

Off Green (blinking) Off Green (solid) Off Green (blinking) Off Green (blinking) Red (solid) Green (solid) Red (solid) Green (blinking) Red (solid) Green (solid) Red (solid) Green (solid)

there is no data traffic on the LAN. there is data traffic on the LAN. the physical link is down; no Ethernet connection. there is link integrity on the LAN; the physical link is up. no data traffic is being received on the V.35. data is being received on the V.35. no data traffic is being transmitted on the V.35. data is being transmitted on the V.35. Layer 2 is down. Layer 2 is up. the T1 is non-operational. the phone is off hook. gateway link is down. gateway link is up. Layer 2 is down. Layer 2 is up.

Red (solid)

gateway status is inactive.

Green (solid)

gateway status is active.

Yellow (blinking)

the phone is off hook.

Off

the phone is on hook.

Off

there is no power connected to the system.

Green (solid)

AC power is operational and battery is functional.

Red/Green (alternating) AC power is operational, but the battery is not functional.

Amber (solid)

AC power has failed and the battery is functional.

Red/Amber (alternating) AC power has failed and the battery is not functional.

Green (solid)

Layer 1 is up.

Green (blinking slowly) unit was unable to train ­ Layer 1 is down.

Green (blinking rapidly) Layer 1 is training (SDSL and SHDSL only).

26

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 2 Engineering Guidelines

Total Access 612/616/624The front panels of the Total Access 612/616/624 systems are identical. Figure 3 shows the Total Access 612 front panel as a representative of all models.

Figure 3. Total Access 612/616/624 Front Panel Layout

Front Panel LEDsThe front panel provides eight status LEDs to monitor operation and activity. The LED functionality varies based on product and software load (TDM versus ATM). Table 5 provides LED descriptions for Total Access 612/616/624 systems employing TDM software, and Table 4 on page 26 lists ATM software LED functionality.

Table 5. Total Access 612/616/624 TDM Front Panel LEDs

For these LEDs… This color light…

Indicates that…

TX/RX LINK V.35 RX V.35 TX DATAVOICE

Off Green (blinking) Off Green (solid) Off Green (blinking) Off Green (blinking) Red (solid) Yellow (solid) Green (solid) Red (solid) Green (blinking) Green (solid)

there is no data traffic on the LAN. there is data traffic on the LAN. the physical link is down; no Ethernet connection. there is link integrity on the LAN; the physical link is up. no data traffic is being received on the V.35. data is being received on the V.35. no data traffic is being transmitted on the V.35. data is being transmitted on the V.35. the T1 is in red alarm or T1 sync loss has occurred. the T1 is in test. Layer 2 is up. the T1 is down. the phone is off hook. the T1 is operational and the phone is on hook.

61200624L1-1B

© 2004 ADTRAN, Inc.

27

Section 2 Engineering Guidelines

Total Access 600 Series System Manual

Table 5. Total Access 612/616/624 TDM Front Panel LEDs (Continued)

For these LEDs… This color light…

Indicates that…

BATT PWR NET

Off

there is no power connected to the system.

Green (solid)

AC power is operational and battery is functional.

Red/Green (alternating) AC power is operational, but the battery is not functional.

Amber (solid)

AC power has failed and the battery is functional.

Red/Amber (alternating) AC power has failed and the battery is not functional.

Green (solid)

Layer 1 is up.

Green (blinking)

Layer 1 is down.

4. REVIEWING THE REAR PANEL DESIGNThe Total Access 600R provides a NTWK connection (via an RJ-48 connector), a CRAFT interface (via an RJ-49 connector), a 10/100BASET interface (via an RJ-48 connector), and an AC PWR connection (via a 3-prong detachable power cord). In addition, systems can include the optional DSX-1 interface (via an RJ-48 connector). The Total Access 600R rear panel differs from the rest of the family in that it does not have a VOICE connection (50-pin amphenol connector). Figure 4 illustrates a standard Total Access 600R rear panel.

Figure 4. Total Access 600R Rear PanelAll other Total Access 600 Series systems contain the following rear panel interfaces regardless of the model: VOICE connection (via a 50-pin female amphenol connector), a NTWK connection (via an RJ-48 connector), a CRAFT interface (via an RJ-48 connector), a 10/100BASET interface (via an RJ-48 connector), a V.35 connection (via a 34-pin Winchester-style connector), a BATT connection (via a 3-pin modular plug), and an AC PWR connection (via a 3-prong detachable power cord). In addition, systems can include either a LIFE LINE analog interface (via an RJ-48 connector) or an optional DSX-1 interface (via an RJ-48 connector). Figure 5 on page 29 illustrates a standard Total Access 604/608, and Figure 6 and Figure 7 on page 29 illustrate the Total Access 604/608 rear panels with the LIFE LINE analog and DSX-1 interfaces, respectively. Figures 8 through 10 on page 29 illustrate the Total Access 612/616/624 rear panels.

28

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 2 Engineering Guidelines

Figure 5. Total Access 604/608 Rear Panel

Figure 6. Total Access 604/608 Rear Panel with Optional Life Line POTS

Figure 7. Total Access 604/608 Rear Panel with Optional DSX-1 Interface Figure 8. Total Access 612/616/624 Rear PanelFigure 9. Total Access 612/616/624 Rear Panel with Optional Life Line POTS

61200624L1-1B

© 2004 ADTRAN, Inc.

29

Section 2 Engineering Guidelines

Total Access 600 Series System Manual

Figure 10. Total Access 612/616/624 Rear Panel with Optional DSX-1 Interface

VOICE ConnectionA single 50-pin female amphenol connector provides the interconnect wiring for the analog FXS and FXO (available as an option only on the Total Access 624) circuits. Figure 11 shows the VOICE connector pinout.

25 50P 24 49P 23 48P 22 47P 21 46P 20 45P 19 44P 18 43P 17 42P 16 41P 15 40P 14 39P 13 38P 12 37P 11 36P 10 35P 9 34P 8 33P 7 32P 6 31P 5 30P 4 29P 3 28P 2 27P 1 26

Slot 6 Slot 5 Slot 4 Slot 3 Slot 2 Slot 1

NC NC T R Circuit 4 T Circuit 3 R T Circuit 2 R T Circuit 1 R TCircuit 4 R T Circuit 3 R T Circuit 2 R T Circuit 1 R T Circuit 4 R T Circuit 3 R T Circuit 2 R T Circuit 1 R T Circuit 4 R T Circuit 3 R T Circuit 2 R T Circuit 1 R TCircuit 4 R T Circuit 3 R TCircuit 2 R T Circuit 1 R T Circuit 4 R T Circuit 3 R T Circuit 2 R T Circuit 1 R

50 PIN AMP RECEPTACLE

Figure 11. VOICE Connector Pin Assignments

NTWK ConnectionThe Total Access 600 Series NTWK connection is provided via an RJ-48 connector regardless of the network technology (T1, ADSL, SDSL, etc.). Table 6 shows the NTWK connection pinout (identical across all technologies).

30

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 2 Engineering Guidelines

PIN 1 2 3, 6-8 4 5

Table 6. NTWK Connection Pinout

NAME RX RING RX TIP –­­­­­ TX RINGTX TIP

DESCRIPTION Receive data from the network Receive data from the network Unused Transmit data toward the network Transmit data toward the network

CRAFT Port

The CRAFT port (EIA-232) on the rear panel connects to a computer or modem and provides the following functions: · Accepts EIA-232 input from a PC or a modem for controlling the Total Access 600 Series. · Baud rate is user-configurable. · Acts as input for either VT100 or PC control. · Acts as an interface for flash memory software downloads using XMODEM.

Table 7 shows the CRAFT port pinout.

Table 7. CRAFT Pinout

PIN

NAME

DESCRIPTION

1

GND

Ground ­ connected to unit chassis

2

RTS

Request to send ­ flow control

3

RXDATA

Receive data

4

DTR

Data terminal ready

5

TXDATA

Transmit data

6

CD

Carrier detect

7

–­­­­­

Unused

8

CTS

Clear to send – flow control

A DB-9 to RJ-48 adapter is needed to connect a PC or VT100 terminal to the CRAFT port. This adapter is not part of the Total Access 600 Series shipment. You may obtain a free adapter (P/N 3196ADPT001) by contacting ADTRAN Technical Support or by adding the adapter to the system order. You can also build your own adapter by purchasing unassembled adapter kits from Black Box or Datacomm Warehouse (or other equivalent companies). The adapter pinout is shown in Table 8.

Table 8. DB-9 to RJ-48 Adapter Pinout

DB-9 2 3 5

RJ-48 5 3 1

Transmit Data Receive Data Ground

DESCRIPTION

61200624L1-1B

© 2004 ADTRAN, Inc.

31

Section 2 Engineering Guidelines

Total Access 600 Series System Manual

Table 8. DB-9 to RJ-48 Adapter Pinout (Continued)

DB-9

RJ-48

Note: All other pins are unused.

DESCRIPTION

32

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 2 Engineering Guidelines

10/100BaseT ConnectionThe 10/100BASET port (RJ-48C) provides a 10/100BaseT Ethernet LAN connection for IP Routing, TFTP, SNMP, and Telnet connections. Table 9 shows the 10/100BaseT pinout.

Table 9. Ethernet Pinout

PIN

NAME

DESCRIPTION

1

TX1

Transmit Positive

2

TX2

Transmit Negative

3

RX1

Receive Positive

4, 5

–­­­­­

Unused

6

RX2

Receive Negative

7, 8

–­­­­­

Unused

V.35 Connection

The Total Access 600 Series system provides a single V.35 Winchester-style connection on the rear of the unit (as defined in Table 10).

PIN/CCIT A/101 B/102 C/105 D/106 E/107 E/109 H/– J/– R/104 T/104

Table 10. V.35 Winchester Pinout

DESCRIPTION Protective ground (PG) Signal ground (SG) Request to send (RTS) from DTE Clear to send (CTS) to DTE Data set ready (DSR) to DTE Data carrier detect Data terminal ready (DTR) from DTE Ring indicator (RI) Received data (RD-A) to DTE Received data (RD-B) to DTE

PIN/CCIT V/115 X/115 P/103 S/103 Y/114 AA/114 U/113 W/113 NN/–

DESCRIPTION RX clock (RC-A) to DTE RX clock (RC-B) to DTE Transmitted data (TD-A) from DTE Transmitted data (TD-B) to DTE TX clock (TC-A) to DTE TX clock (TC-B) to DTE External TX clock (ETC-A) from DTE External TX clock (ETC-B) from DTE Test mode (TM) to DTE

Battery Backup ConnectionAn optional battery backup system is available for the Total Access 604/608 (P/N 1200641L1) and the Total Access 612/616/624 (P/N 1175044L1, 1175044L2, or 1175044L4). For more details on the battery backup system installation and operation, refer to the documentation available for your specific battery backup unit.AC Power ConnectionEach unit includes an auto ranging 90-250 VAC, 50/60 Hz power supply with a 3-prong removable cable. Connect the power supply to a standard 120 VAC, 60 Hz electrical outlet for proper operation.

61200624L1-1B

© 2004 ADTRAN, Inc.

33

Section 2 Engineering Guidelines

Total Access 600 Series System Manual

Life Line Analog Connection

The LIFE LINE analog connection is only available on Total Access 600 Series xDSL models.

The LIFE LINE analog connection provides assured voice for port 1. If the unit loses power or goes into alarm, the network voice service is inhibited and the on-board relay opens. The first port of the voice connector is provided with analog voice from the LIFE LINE analog connection. A regular POTS line must be plugged into the LIFE LINE port. Table 11 provides the LIFE LINE port pinout.

Table 11. LIFE LINE Connection Pinout

PIN

DESCRIPTION

1,2

Unused

3

Life Line Ring

4

Life Line Tip

5,6

Unused

DSX-1 Interface

The DSX-1 interface is optional and must be requested at the time of order placement. Total Access 600 Series systems without the DSX-1 interface are not field-upgradeable to add DSX-1 access.

Table 12 provides the DSX-1 port pinout.

PIN 1 2 3, 6-8 4 5

Table 12. DSX-1 Connection Pinout

NAME TX RING TX TIP –­­­­­ RX RING RX TIP

DESCRIPTION Transmit data toward the network (RING) Transmit data toward the network (TIP) Unused Receive data from the network (RING) Receive data from the network (TIP)

34

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 2 Engineering Guidelines

5. AT-A-GLANCE SPECIFICATIONSTable 13 lists the unit specifications.

Table 13. Specifications

Application

Feature

Specification

T1 Network Interface

Physical Interface

RJ-48C

Line Rate

1.544 Mbps +/- 75 bps

Framing Line Code

D4 (SF)/ESF AT&T 54016 ANSI T1.403AMI/B8ZS

ADSL Network Interface (ITU G.992.1)

Throughput

Up to 8 Mbps downstream Up to 1 Mbps upstream

Interoperability

Interoperate with G.992.1 compliant DSLAMs

G.SHDSL Network Interface (ITU G.991.2)

Line Rate

192 kbps to 2.3 Mbps

SDSL Network Interface (2B1Q Conexant-based)

Line Rate

160 kbps to 2.3 Mbps

Training

Conexant Autobaud capable

ATM Support

Voice Codes

PCM (G.711) 32K ADPCM (G.726)

PVC Capability

6 PVCs (1 voice, 5 data)

Echo Cancellation

G.165/G.168 Echo Cancellation, 8 ms echo tail

QoS Support

VBR-rt (voice) UBR (data)

Specifications

AAL2 (voice) AAL5 (data, voice) RFC 1483 (multiprotocol over ATM) RFC 2364 (PPPoA)

Frame Relay Support

Specifications

FRF.5 FRF.8

61200624L1-1B

© 2004 ADTRAN, Inc.

35

Section 2 Engineering Guidelines

Total Access 600 Series System Manual

Application Analog PortsRouting (Ethernet) Management

Table 13. Specifications (Continued)

Feature

Specification

Number of FXS Ports ModesRinging Ring Voltage

4 ports for Total Access 604 8 ports for Total Access 608 12 ports for Total Access 612 16 ports for Total Access 616 24 ports for Total Access 624FXS Loop Start FXS Ground Start TR08 Single TR08 UVG DP0 Tandem (E&M)Balanced ringing, 5 REN per port not to exceed 35 RENFixed 70 VACrms with 20 VDC offset

Specifications IP SupportPPP Support DHCP

IEEE 802.3TCP, RIP V1, RIP V2, UDP, ICMP, ARP, UDP Relay, SYSLOGLCP, IPCP, BCPDHCP Server to LAN DHCP from network

CRAFT InterfaceEthernet 10/100BaseT Interface

EIA 232, Physical RJ-48CSNMP V1 support · 604/608 ATM units running D.01.36 firmware or previous · 612/616/624 ATM units running D.01.30 firmware or previousSNMP V2 support · TDM units running A.04 firmware or laterFull menu-driven Telnet access Software download via TFTP Support for VoDSL gateway management systems and firmware download

36

© 2004 ADTRAN, Inc.

61200624L1-1B

NETWORK TURNUP PROCEDUREThis section provides shipment contents list, grounding instructions, mounting options, and specifics of supplying power to the unit.CONTENTSTools Required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Unpack and Inspect the SYSTEM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Contents of ADTRAN Shipments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Grounding Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Mounting Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Wallmounting the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Rackmounting the Total Access 612/616/624 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Supplying Power to the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 AC Powered Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40FIGURESFigure 1. Wallmount Orientation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Figure 2. Wallmounting the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

61200624L1-1B

© 2004 ADTRAN, Inc.

35

Network Turnup Procedure

Total Access 600 Series System Manual

1. INTRODUCTIONThis section discusses Total Access 600 Series installation.2. TOOLS REQUIREDThe tools required for wallmount installation of the unit are: · Four #8 x 3/4 inch pan-head wood screws · Drill and drill bit set · Flat head screwdriver (medium) · Two Phillips head screwdrivers (small/medium) · Wire-wrap gun (optional) · 25-pair male amphenol cable (customer connection) · Selected punch-down block and tool

To prevent electrical shock, do not install equipment in a wet location or during a lightning storm.

During installation, power should be the last connection made.Electronic equipment can be damaged by static electrical discharge. Before handling modules, put on an antistatic discharge wrist strap to prevent damage to electronic components. Place equipment in antistatic packing material when transporting or storing. When working on equipment, always place it on an approved antistatic mat that is electrically grounded.3. UNPACK AND INSPECT THE SYSTEMEach unit is shipped in its own cardboard shipping carton. Open each carton carefully and avoid deep penetration into the carton with sharp objects.After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier, and then contact ADTRAN Customer Service (see Customer Service, Product Support Information, and Training in the front of this manual).

36

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 3 Network Turnup Procedure

Contents of ADTRAN ShipmentsYour ADTRAN shipment includes the following items: · The Total Access 6XX unit with attached wallmount brackets · The Total Access 600 Series System CD ­ ADTRAN P/N 3253052 · Hardware revision notice card ­ ADTRAN P/N 61200624L1-17 · Mounting instructions ­ ADTRAN P/N 61200624L1-19 · RJ-45 to RJ-45 8-pin cable (6 ft) ­ADTRAN P/N 3127004 · Cable tie (for securing attached cables) ­ ADTRAN P/N 3292032 · Four rubber feet (for table top installations) ­ ADTRAN P/N 3270BF003 · 3-prong, detachable power cord ­ ADTRAN P/N 3127009

Customer must supply Ethernet cable and the RJ-48 to DB-9 adapter and DB-9 serial cable for configuration via the VT100 CRAFT interface.

4. GROUNDING INSTRUCTIONSTo following paragraphs provide grounding instruction information from the Underwriters’ Laboratory UL60950 Standard for Safety of Information Technology Equipment Including Electrical Business Equipment, with revisions dated March 15, 2002.An equipment grounding conductor that is not smaller in size than the ungrounded branch-circuit supply conductors is to be installed as part of the circuit that supplies the product or system. Bare, covered, or insulated grounding conductors are acceptable. Individually covered or insulated equipment grounding conductors shall have a continuous outer finish that is either green, or green with one or more yellow stripes. The equipment grounding conductor is to be connected to ground at the service equipment.The attachment-plug receptacles in the vicinity of the product or system are all to be of a grounding type, and the equipment grounding conductors serving these receptacles are to be connected to earth ground at the service equipment.A supplementary equipment grounding conductor shall be installed between the product or system and ground that is in addition to the equipment grounding conductor in the power supply cord.The supplementary equipment grounding conductor shall not be smaller in size than the ungrounded branch-circuit supply conductors. The supplementary equipment grounding conductor shall be connected to the product at the terminal provided, and shall be connected to ground in a manner that will retain the ground connection when the product is unplugged from the receptacle. The connection to ground of the supplementary equipment grounding conductor shall be in compliance with the rules for terminating bonding jumpers at Part K or Article 250 of the National Electrical Code, ANSI/NFPA 70. Termination of the supplementary equipment grounding conductor is permitted to be made to building steel, to a metal electrical raceway system, or to any grounded item that is permanently and reliably connected to the electrical service equipment ground.The supplemental grounding conductor shall be connected to the equipment using a number 8 ring terminal and should be fastened to the grounding lug provided on the rear panel of the equipment. The ring terminal should be installed using the appropriate crimping tool (AMP P/N 59250 T-EAD Crimping Tool or equivalent).

61200624L1-1B

© 2004 ADTRAN, Inc.

37

Network Turnup Procedure

Total Access 600 Series System Manual

5. MOUNTING OPTIONSAll units may be wallmounted or installed in a table-top application. In addition, the Total Access 612/616/624 units are available for 19- or 23-inch rackmount installations. Wallmount brackets are included with the unit and are already attached. For a rackmount installation, optional rackmount brackets must be purchased (19″ ­ P/N 1200627L1, 23″ ­ P/N 1200627L2).

Be careful not to upset the stability of the equipment mounting rack when installing this product.

Wallmounting the UnitTools NeededThe unit mounts and connects with standard fasteners and hand tools: · Four #8 x 3/4-inch pan-head wood screws · Drill and drill bit set · Flat head screwdriver (medium) · Two Phillips head screwdrivers (small/medium) · Wire-wrap gun (optional) · 25-pair male amphenol cable (customer connection) · Selected punch-down block and tool Follow these steps to wallmount the unit:

Step 1.2.3. 4.

Wallmount InstallationActionDecide on a location for the unit. Keep in mind that the unit needs to be mounted at or below eye-level so that the LEDs are viewable. IMPORTANT! Mount the chassis with LEDs facing to the side or down as shown in Figure 1 on page 39 (not facing up). Refer to Figure 2 on page 39 for a wallmount illustration.Prepare the mounting surface by attaching a board (typically plywood, 3/4″ to 1″ thick) to a wall stud. IMPORTANT! Mounting to a stud ensures stability. Using sheetrock anchors may not provide sufficient long-term stability.Have someone else hold the unit in position as you install two #6 to #10 (1 1/2″ or greater in length) wood screws through the unit’s brackets and into the mounted board.Proceed to the steps given in Supplying Power to the Unit on page 40.

38

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 3 Network Turnup Procedure

Figure 1. Wallmount Orientation

Note: The Total Access 600 Series units come equipped with wall mount brackets preinstalled.Figure 2. Wallmounting the Unit

61200624L1-1B

© 2004 ADTRAN, Inc.

39

Network Turnup Procedure

Total Access 600 Series System Manual

Rackmounting the Total Access 612/616/624Tools NeededThe Total Access 612/616/624 mount and connect with standard fasteners and hand tools: · Rackmount brackets (19″­P/N 1200627L1 or 23″­P/N 1200627L2) · Flat head screwdriver (medium) · Two Phillips head screwdrivers (small/medium) · Wire-wrap gun (optional) · 25-pair male amphenol cable (customer connection) · Selected punch-down block and tool Follow these steps to rackmount the Total Access 612/616/624:

Step 1.

Rackmount InstallationActionRemove the wallmount brackets. (The Total Access 612/616/624 ships with wallmount brackets attached.) Attach the mounting brackets to the side of the unit.

To avoid damaging the unit, use only the screws included in the mounting bracket shipment when attaching mounting ears to the chassis.2. Position the Total Access 612/616/624 in a stationary equipment rack. This unit takes up 1 RU of space. To allow proper grounding, scrape the paint from the rack around the mounting holes where the Total Access 612/616/624 will be positioned.3. Have someone else hold the unit in position as you install two mounting bolts through the unit’s brackets and into the equipment rack using a #2 Phillip’s screwdriver.4. Proceed to the steps given in Supplying Power to the Unit.

6. SUPPLYING POWER TO THE UNITThe Total Access 600 Series is not offered in DC powered versions. However, optional DC battery backup systems are available for the Total Access 604/608 (P/N 1200641L1) and Total Access 612/616/624 (P/N 1175044L1, 2, or 4) systems.AC Powered SystemsThe AC powered unit comes equipped with a 3-prong, detachable power cord for connecting to a properly grounded power receptacle. As shipped, the unit is set to factory default conditions. After installing the unit it is ready for power-up. To apply power to the unit, ensure that it is properly connected to an appropriate power source.· This unit shall be installed in accordance with Article 400 and 364.8 of the NEC NFPA 70 when installed outside of a Restricted Access Location (i.e., central office, behind a locked door, service personnel only area).· Power to the Total Access 600 Series AC system must be from a grounded 90-130 VAC, 50/60 Hz source.· Verify the power receptacle uses double-pole, neutral fusing. · Maximum recommended ambient operating temperature is 45 ºC.

40

© 2004 ADTRAN, Inc.

61200624L1-1B

USER INTERFACE GUIDEThis section of ADTRAN’s Total Access 600 Series System Manual is designed for use by network administrators and others who will configure and provision the system. It contains information about navigating the VT100 user interface, configuration information, and menu descriptions.CONTENTSNavigating the Terminal Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Terminal Menu Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Navigating using the Keyboard Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45MAIN Menu and System Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Selecting the Appropriate Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 Security Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Menu Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 System Info . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 System Config. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 System Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Interfaces (Network T1). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Interfaces (Network SHDSL). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Interfaces (Network SDSL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Interfaces (Network ADSL) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 Interfaces (DSX) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78 Interfaces (ETH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Interfaces (V35). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Interfaces (FXS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82 Interfaces (FXO) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 L2 Protocol (TDM Firmware). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 L2 Protocol (TDM Firmware) ­ T1 Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90 L2 Protocol (TDM Firmware) ­ T1 Interface > PPP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91 L2 Protocol (TDM Firmware) ­ T1 Interface > FRE Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . 93 L2 Protocol (TDM Firmware) ­ T1 Interface > HDLC Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . 98 L2 Protocol (TDM Firmware) ­ T1 Interface > Auto Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 L2 Protocol (ATM Firmware) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 L2 Protocol (ATM Firmware) ­ Network (NET) Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 L2 Protocol (ATM Firmware) ­ NET> ATM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101 L2 Protocol (ATM Firmware) ­ Network Interface > CuMtn FRE . . . . . . . . . . . . . . . . . . . . . . . 111 L2 Protocol (ATM Firmware) ­ V.35 Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 L2 Protocol (ATM Firmware) ­ DSX Interface. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115 L2 Protocol (All Firmware) ­ ETH Interface > 802.3 Protocol . . . . . . . . . . . . . . . . . . . . . . . . . . 116 Bridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Security . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 DS0 Maps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149Appendices (T1 TDM Applications) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152Appendices (T1 ATM Applications) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169

61200624L1-1B

© 2004 ADTRAN, Inc.

41

Section 4 User Interface Guide

Total Access 600 Series System Manual

FIGURES

Figure 1. Figure 2. Figure 3. Figure 4. Figure 5. Figure 6. Figure 7. Figure 8. Figure 9. Figure 10. Figure 11. Figure 12. Figure 7. Figure 10.

Top-Level Terminal Menu Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Alternate Menu View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 System Info Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 System Config Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 System Utility Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Interfaces Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 L2 Protocol (T1 TDM) Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 L2 Protocol (SDSL ATM) Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 Bridge Menu. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 Router Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119 Security Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 DS0 Maps Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 Application Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169 Application Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 174

TABLES

Table 1. Table 2. Table 3.

Password Security Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 Instructions for Changing Passwords . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Telnet Security Levels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54

42

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

1. NAVIGATING THE TERMINAL MENUTo access the terminal menus and management features of the Total Access 6XX, connect the unit to a VT100 terminal (or VT100 terminal emulator) via the CRAFT interface on the rear panel. Configure the terminal settings for 9600 data rate, no parity, 8 data bits, 1 stop bit, and no flow control.After connecting to the unit and beginning a terminal session, a login screen appears. There is no default password for the Total Access 6XX; press <ENTER> to access the terminal menus. (Refer to DLP-2, Logging in to the System for detailed instructions.)

Terminal Menu WindowAfter logging in, all menu items and data fields are displayed in the terminal menu window (see Figure 1), through which you have complete control of the unit.

Menu Path Left Pane

Slot Status

EthernetLink Status

Right Pane

ModeL2 Status (ATM) DS0 Map (TDM)Tool Tip

Telnet Info(not present)

Extended Help Navigation Help

Network StatusConfig Status

Figure 1. Top-Level Terminal Menu WindowMenu PathThe first line of the terminal menu window (the menu path) shows the session’s current position (path) in the menu structure. For example, Figure 1 shows the top-level menu with the cursor on the SYSTEM CONFIG submenu; therefore, the menu path reads TA6XX IAD/SYSTEM CONFIG.Window PanesWhen you first start a terminal menu session, the terminal menu window is divided into left and right panes. The left pane shows the list of available submenus, while the right pane shows the contents of the currently selected submenu.You can view the terminal windows in two ways: with fields and submenus displaying horizontally across the right pane, or with fields and submenus displaying vertically down the right pane. Viewing submenus vertically rather than horizontally allows you to see information at a glance rather than scrolling horizontally across the window. To change the view, move your cursor to an index number and press <ENTER>. Figure 2 on page 44 shows this alternate view. Fields and submenu names may vary slightly in this view.

61200624L1-1B

© 2004 ADTRAN, Inc.

43

Section 4 User Interface Guide

Total Access 600 Series System Manual

Figure 2. Alternate Menu View

Window Pane NavigationUse the following chart to assist you in moving between and within the two window panes.

To do this… Move from left pane to right pane Move from right pane to left paneMove within each pane

Press this key…Tab Enter Right arrowTab Escape Left arrow BackspaceUp arrow Down arrow Left arrow Right arrow

Right Window Pane NotationThe right window pane shows the contents of the currently selected menu. These contents include both submenu items and data fields. Some submenus contain additional submenus and some data fields contain additional data fields. The following chart explains the notation used to identify these additional items.

This notation…

Means that…

[+]

more items are available when selected.

[DATA] <+>

more items are available when selected. an action is to be taken, such as activating a test.

Highlighted menu item

you can enter data in this field.

Underlined field

the field contains read-only information.

44

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

Additional Terminal Menu Window Features· Mode ­ displays the network interface mode of the unit (for example, T1 IAD, SHDSL IAD, SDSL IAD, ADSL IAD)· L2 Status ­ displays the current status of the L2 protocol (ATM sync is either up or down) ­ ATM Only· DS0 Mapping ­ displays the current mapping of DS0s in the system. DS0s mapped to the router display r, unmapped DS0s display ­, and all other DS0s display *.· Tool Tip ­ provides a brief description of the currently selected mode.· Slot Status ­ displays type of module installed in each slot. No entry will appear for slots not containing a module.· Telnet Info ­ displays the user name when connected via Telnet. This information is not displayed when connecting to the system via the CRAFT interface.· Ethernet Link Status ­ displays the current status of the integrated Ethernet interface (located on the rear of the chassis).· Extended Help ­ displays information about selected commands <CTRL+A>.· Navigation Help ­ lists characters used for navigating the terminal menu and session management <CTRL+Z>.· Config Status ­ displays * when current configuration contains changes that have not been saved to flash memory. Save changes by backing out to the main menu, or press <CTRL + W> to force a manual save.

Navigating using the Keyboard KeysYou can use various keystrokes to move through the terminal menu, to manage a terminal menu session, and to configure the system. Press <CTRL+Z > to activate a pop-up screen listing the navigation keystrokes.

Moving through the Menus

To do this…

Press this key…

Return to the home screen

H

Jump between two menu items

J

Press <J> while the cursor is located on a menu item, and you jump back to the

main screen.

Go to another menu item, press <J>, and you jump back to the screen that was

displayed the first time you pressed <J>.

Press <J> anytime you want to jump between these items.

Select items

Arrows

Edit a selected menu item

Enter

Cancel an edit

Escape

Close pop-up help screen

Escape

Move between the left and right panes

Tab Arrows

Move to the top of a screen

A

61200624L1-1B

© 2004 ADTRAN, Inc.

45

Section 4 User Interface Guide

Total Access 600 Series System Manual

To do this… Move to the bottom of a screen Ascend one menu level Jump to terminal mode Jump to NAT menu

Press this key… ZBackspace CTRL+T CTRL+N

Session Management Keystrokes

To do this…

Press this key…

Log out of a session

CTRL+L

Refresh the screen To save time, only the portion of the screen that has changed is refreshed. This option should only be necessary if the display picks up incorrect characters caused by disconnecting and reconnecting the terminal session.

CTRL+R

Configuration Keystrokes

To do this…

Press this key…

Restore factory default settings

F

This setting restores the factory defaults based on the location of the cursor. If the

cursor is on an interface line (in the INTERFACES menu), then only the selected

interface is updated to factory defaults.

Copy selected items to the clipboard

C

The amount of information you can copy depends on the cursor location when you

press <C>:

If the cursor is over an editable field, only that item is copied.

If the cursor is over the index number of a list, then all of the items in the row of

the list are copied. For example, if the cursor is over the selection # field in the

INTERFACES screen, all of the information associated with the interface is

copied.

Paste the item stored in the clipboard, if the information is compatible

P

You must confirm all pastes — except those to a single editable field.

Increment the value of certain types of fields by one when you paste information

>

into those fields

Decrement the value of certain types of fields by one when you paste information

<

into those fields

Save the current configuration immediately to flash memory

CTRL+W

Insert a new list item

I

For example, add a new item to the TELNET USER connection list by pressing <I>

while the cursor is over the index number.

46

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

To do this…

Press this key…

Delete a list item

D

For example, delete an item from the TELNET USER connection list by pressing

<D> while the index number is active.

Getting HelpThe bottom line of the terminal menu window contains context-sensitive help information. When the cursor is positioned over a set of configuration items, a help message displays (when available) providing a description of the item. When more detailed help is available for a particular item, ^A displays at the bottom of the window. At this point, pressing <CTRL+A> displays a pop-up help screen with information about the item.Press <CTRL+Z> to activate a help screen that displays the available keystrokes you can use to navigate the main menu system. Press <Exit> to remove these help screens.

2. MAIN MENU AND SYSTEM CONTROL

Selecting the Appropriate MenuThe main menu system is the access point to all other operations. Each menu item has several functions and submenus that identify and provide access to specific operations and parameters. Use the following chart to help select the appropriate menu.

To do this…

Go to this menu…

Review and monitor general system information for the Total Access 6XX

SYSTEM INFO

Set up the operational configuration for the Total Access 6XX

SYSTEM CONFIG

Upgrade firmware, perform config transfers, ping, and access terminal mode SYSTEM UTILITY

Review and configure settings for all interfaces (including installed modules) INTERFACES

Configures the Layer 2 protocol for the various interfaces (T1, Ethernet, etc.) L2 PROTOCOL and provides all applicable L2 status information

Configure the bridging parameters and view applicable bridging statistics

BRIDGE

Define, configure, and monitor all Total Access 6XX Router functions

ROUTER

Configure security filters for L2 traffic and define RADIUS server parameters SECURITY

Map data and voice ports (from integrated interfaces as well as installed modules) to network time slots

DS0 MAPS

61200624L1-1B

© 2004 ADTRAN, Inc.

47

Section 4 User Interface Guide

Total Access 600 Series System Manual

Security Levels

Password security levels only apply to Telnet connections. Connecting to the system through the rear CRAFT interface automatically provides maximum rights.

To edit main menu system items, you must have a password and the appropriate security level. Table 1 describes the security levels.

Table 1. Password Security Level

Security Level FullSupport ConfigRouter Voice Status

Description Permission to edit every menu item, including creating and editing passwords maximum rights Access to all commands except passwords Access to all commands except passwords, flash/firmware download, configuration transfers, authentication methods, terminal mode, and unit reset Read/write access to all Router menu items Read/write access to all Voice menu items Read-only permission for all menu items – minimum rights

3. MENU DESCRIPTIONSThe remainder of this section describes Total Access 6XX menu and submenu options.

To help you follow the terminal menu hierarchy, the following notations are used:MENUS > SUBMENUS > SUB-SUBMENUS

48

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

SYSTEM INFOThe SYSTEM INFO menu provides basic information about the unit as well as data fields for editing information. Figure 3 displays the submenus that are available when you select this menu item.0

Figure 3. System Info MenuSYSTEM INFO > SYSTEM NAMEProvides a user-configurable text string for the name of the unit. This name can help you distinguish between different installations. You can enter up to 127 alpha-numeric characters in this field, including spaces and special characters (such as an underscore). This name will appear on the top line of all screens.SYSTEM INFO > SYSTEM LOCATIONProvides a user-configurable text string for the location of the unit. This field is to help you keep track of the actual physical location of the unit. You can enter up to 127 alphanumeric characters in this field, including spaces and special characters (such as an underscore).SYSTEM INFO > SYSTEM CONTACTProvides a user-configurable text string for a contact name. You can use this field to enter the name, phone number, or E-mail address of a person responsible for the unit. You can enter up to 127 alpha-numeric characters in this field, including spaces and special characters (such as an underscore).SYSTEM INFO > UNIT NAME(Read only) Displays a product-specific name for the unit (such as TA 616, TA 604, etc).SYSTEM INFO > CLEI CODE(Read only) Displays the registered CLEI code for the unit.

61200624L1-1B

© 2004 ADTRAN, Inc.

49

Section 4 User Interface Guide

Total Access 600 Series System Manual

SYSTEM INFO > PART NUMBER(Read only) Displays the ADTRAN-specific part number for the unit.SYSTEM INFO > CONTROLLER SERIAL NUMBER(Read only) Displays the ADTRAN-specific part number for the chassis hardware. The serial number of the unit will automatically display in this field. This serial number matches the serial number located on the bottom of the unit’s chassis.SYSTEM INFO > SYSTEM SERIAL NUMBER(Read only) Displays the serial number for the entire system configuration including specific network interface, FXS specifics, and specialized software, as well as the base chassis. This serial number must be programmed at ADTRAN and will display dashes (—-) for any unit manufactured prior to this serial number addition.SYSTEM INFO > FIRMWARE REVISION(Read only) Displays the current firmware revision level of the unit.SYSTEM INFO > BOOTCODE REVISION(Read only) Displays the current bootcode revision.SYSTEM INFO > SYSTEM UPTIMEDisplays the length of time the unit has been running. Each time you reset the system, this value resets to 0 days, 0 hours, 0 min and 0 secs.SYSTEM INFO > DATE/TIMEDisplays the current date and time, including seconds. To edit this field, place the cursor on the field and press <ENTER>. Then, enter the time in a 24-hour format (such as 23:00:00 for 11:00 pm), and the date in mm-dd-yyyy format (for example, 05-23-2004). Press <ENTER> when you are finished to accept the change.The System Date and Time will reset to 12:00 January 1, 1990 after a system power loss. If accurate system date and time information is crucial, consider using a time server to prevent the clock reset.

50

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

SYSTEM CONFIGSet up the unit’s operational configuration from the SYSTEM CONFIG menu. Figure 4 shows the items included in this menu.

Figure 4. System Config MenuSYSTEM CONFIG > MANAGEMENTSet up the CRAFT port, TELNET ACCESS, SNMP MANAGEMENT, and FDL MANAGEMENT from this menu.SYSTEM CONFIG > MANAGEMENT > CRAFT PORTSet up the CRAFT port parameters from this menu. The unit’s VT100 CRAFT port can be accessed via an RJ-48 connector located on the rear of the unit.SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > PASSWORD PROTECTWhen PASSWORD PROTECT is set to NO, the CRAFT port is not password protected. When set to YES (def), the unit will prompt for a password upon startup.SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > PASSWORDEnter the user-defined password (up to 30 alphanumeric characters including spaces and special characters) to protect the CRAFT port. By default, no password is entered. Table 2 on page 52 provides instructions for changing the password.Connecting directly to the CRAFT port provides full access to all menus. Enable the password on the CRAFT port to protect against unauthorized access.

61200624L1-1B

© 2004 ADTRAN, Inc.

51

Section 4 User Interface Guide

Total Access 600 Series System Manual

Step 1 2 3

Table 2. Instructions for Changing Passwords ActionSelect the PASSWORD field–a new PASSWORD field displays. Type the new password in the ENTER field. Type the new password again in the CONFIRM field.

SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > IDLE TIMEThis option defines the amount of time in minutes user may stay connected without any activity on the CRAFT port before the user is automatically logged out of the system. A value of 0 disables this inactivity timer function enabling users to stay connected until manually logged out. The value range is 0 (def) to 255 (minutes).SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > BAUD RATEThis is the asynchronous rate that the CRAFT port will run. The possible values are 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200. The default value is 9600. The unit and the VT100 terminal or PC with terminal emulation software must be set for the same baud rate.SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > DATA BITSThe number of data bits that the CRAFT port sends in a frame. The possible values are 7 or 8 (def) bits. The unit and the VT100 terminal or PC with terminal emulation software must be set for the same number of data bits.SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > PARITYThis is the asynchronous parity that the CRAFT port will run. The possible values are NONE (def), ODD, or EVEN. The unit and the VT100 terminal or PC with terminal emulation software must have the same parity setting.SYSTEM CONFIG > MANAGEMENT > CRAFT PORT > STOP BITSThis is the number of stop bits used for the CRAFT port. The possible values are 1 (def), 1.5 or 2. The unit and the VT100 terminal or PC with terminal emulation software must have the same number of specified stop bits.SYSTEM CONFIG > MANAGEMENT > TELNET ACCESSActivate the Telnet access and set up the various Telnet parameters from this menu. The Total Access 6XX supports up to five simultaneous Telnet sessions.The Total Access 6XX ships with default Telnet Access parameters of: guest (user), password (password). Change this password during the initial configuration to protect your unit.

52

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > ACCESSSets ACCESS to ON or OFF to allow or block telnet access to the unit. The factory default value for this parameter is ON.SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > AUTHEN METHODSet up the Telnet authentication method from this menu. The choices are LOCAL PASSWORD, RADIUS, LOCAL/RADIUS, and RADIUS/LOCAL. LOCAL/RADIUS indicates that the unit will try Local Password Authentication first, and if that fails, it will try Radius Authentication. RADIUS/LOCAL indicates that the unit will try Radius authentication first, and if that fails, it will try Local Password authentication. The default is LOCAL PASSWORD.SYSTEM CONFIG > MANAGEMENT > TELNET PORTDefines the TCP port number used when establishing a Telnet session. Normal Telnet port is 23. Enter a customized port number if desired. Make certain the Telnet program you use is configured for the same port number (if using a customized port number).SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > USER LISTAdd Telnet users and control the Telnet access conditions through this menu.#Display the index number of the Telnet users. Up to four users can be configured for access to the unit. Each user can be assigned a security level and idle time.NAMEThe name is a text string of the user name for this session. The factory default is UNASSIGNED in the NAME field.You must enter a username in this field (up to 15 characters) because the Telnet entry is not activated until it is assigned a valid username. Editing the UNASSIGNED default to be blank is allowed for a single Telnet entry; duplicate usernames are not allowed. During an active Telnet session the NAME is displayed in the Telnet Information field located at the bottom of the menu screen.PASSWORDWhen the authenticating method is LOCAL PASSWORD, or LOCAL/RADIUS, this text string is used for the password. You can enter up to 30 characters in this field. The factory default is no entry in this field.IDLE TIME (MINS)This sets the amount of time in minutes you can be idle before you are automatically logged off. The factory default is 10 MINUTES. The range is 1 TO 255 MINUTES.LEVELThis is the security level granted to the user. Table 3 on page 54 gives a brief description of each level. The factory default is FULL.

61200624L1-1B

© 2004 ADTRAN, Inc.

53

Section 4 User Interface Guide

Total Access 600 Series System Manual

Table 3. Telnet Security Levels

Security Level FullSupportConfig RouterVoice Status

DescriptionThe user has all access to view and configure all menus (same as logging in to the CRAFT port)The user has read only access to view the SYSTEM INFO menu. The user has privileges to view and change everything under the SYSTEM CONFIG menu except for the CRAFT port settings, Telnet access lists, and the SNMP management communities. The user has full access to the SYSTEM UTILITY menu, including the ability to upgrade firmware and reset the unit. The user has full access to the INTERFACES, L2 PROTOCOL, BRIDGE, ROUTER, and DS0 menus. The user does not have the ability to set RADIUS SERVER settings under the SECURITY menu.The same privileges as support, except that the user does not have privileges to download firmware or configuration from the SYSTEM UTILITY menu. The user additionally does not have the privilege to reset the unit remotely, or enter the terminal menu.The user has read only privileges for the SYSTEM INFO menu. There is no access to the SYSTEM CONFIG menu. The user has PING and TRACEROUTE access from the SYSTEM UTILITY menu. The user is limited to Ethernet configuration and status from the INTERFACES menu. The user has full access to the BRIDGE and ROUTER menus. Access is limited to filters only from the SECURITY menu.The user has read only privileges for the SYSTEM INFO menu. The user has access to the PING and TRACEROUTE utilities from the SYSTEM UTILITIES menu. The user has full access to the FXS module from the INTERFACES menu.The user has read access of all menus except for the following: SYSTEM CONFIG/CRAFT PORT, SYSTEM CONFIG/TELNET ACCESS, SYSTEM CONFIG/SNMP MANAGEMENT, and SECURITY/ RADIUS SERVER. The user does not have access to UPGRADE FIRMWARE, UPGRADE CONFIG, PING, or TRACEROUTE menus. The user cannot reset the unit or enter terminal mode.

SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > ACTIVE SESSIONSProvides a list of all Telnet sessions currently active on the system.#Displays the index number of the Telnet user.NAMEDisplays the assigned user name.PORTDisplays the TCP port used for this Telnet session.TIME TO LIVEDisplays the amount of time (in minutes) before this Telnet session is terminated, if the user remains idle.

54

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

SYSTEM CONFIG > MANAGEMENT > TELNET ACCESS > IP ACCESS LISTSet up the list of allowed Telnet connections by specifying the IP address of the systems used to control the unit.NETWORK ADDRESSEnter network addresses from which Telnet access to the unit is allowed. When a remote unit requests Telnet access to the unit, if the access list is empty or the remote’s IP address matches a list entry, remote access is granted. A network address of 0.0.0.0 with corresponding netmask 255.255.255.255 blocks all host Telnet access. The factory default is 0.0.0.0. (with a 0.0.0.0 subnet MASK), which allows all users Telnet access.MASKThe mask is used to determine which bits of the NETWORK ADDRESS are significant. A “0” bit means “don’t care.” A “1” bit means that the corresponding address bits in the incoming IP packet must match the address bit in the defined NETWORK ADDRESS. The netmask of 255.255.255.255 defines a single IP as the only allowed IP address from the specified network. A NETWORK ADDRESS defined as 192.22.1.0 with a NETMASK of 255.255.255.0 allows all units on the 192.22.1.0 network Telnet access to the unit. The default value is 0.0.0.0 (with a default NETWORK ADDRESS of 0.0.0.0), which allows all users Telnet access.SYSTEM CONFIG > MANAGEMENT > SNMP MANAGEMENTActivate the SNMP management and configure the SNMP communities and traps from this menu.SYSTEM CONFIG > MANAGEMENT > SNMP MANAGEMENT > ACCESSWhen set to OFF, SNMP access is denied. When set to ON, the unit will respond to SNMP managers based on the configuration of the COMMUNITIES fields. The factory default is ON.SYSTEM CONFIG > MANAGEMENT > SNMP MANAGEMENT > TRAP DELAYWhen enabled, the Total Access 600 Series inserts a delay before transmitting a created trap for the SNMP session.SYSTEM CONFIG > MANAGEMENT > SNMP MANAGEMENT > COMMUNITIESSet up the SNMP communities parameters from this menu.#Displays the index number of the SNMP Communities. This list is used to set up to 8 SNMP communities that the unit will allow.

NAMEThis is the text string used to identify the SNMP community. The factory default is no entry in the name parameter.

61200624L1-1B

© 2004 ADTRAN, Inc.

55

Section 4 User Interface Guide

Total Access 600 Series System Manual

PRIVILEGEThe access for this manager can be assigned three levels. The factory default is NONE.

NONE GET GET/SET

No access is allowed for this community or manager. Manager can only read items. Manager can read and set items.

MANAGER IPThis may be used in conjunction with the Netmask field to define a range of manager IPs. A netmask of 255.255.255.255 defines a single IP as the manager host IP. A MANAGER IP defined as 192.22.1.0 with a NETMASK of 255.255.255.0 allows all managers on the 192.22.1.0 network access to the SNMP information. The default value is 0.0.0.0.

NETMASKThe mask is used to determine which bits of the MANAGER IP are significant. A “0” bit means “don’t care.” A “1” bit means that the corresponding address bits in the incoming SNMP packet must match the address bit in the defined MANAGER IP. The netmask of 255.255.255.255 defines a single IP as the manager host IP. A MANAGER IP defined as 192.22.1.0 with a NETMASK of 255.255.255.0 allows all managers on the 192.22.1.0 network access to the SNMP information. The default value is 0.0.0.0.SYSTEM CONFIG > MANAGEMENT > SNMP MANAGEMENT > TRAPSSets up the trap manager name and IP from this menu.#Displays the index number in the SNMP traps table. This list allows up to 20 managers to be listed to receive traps.

MANAGER NAMEThe text string describing the name of the entry. It is intended for easy reference and has no bearing on the SNMP trap function. You can enter up to 31 characters in this field. The factory default is no entry in the MANAGER NAME field.

MANAGER IPThis is the IP address of the manager that is to receive the traps. The factory default is 0.0.0.0.SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENTEnables the FDL management and configures mode and IP addresses from this menu.

56

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > MODEThis enables the FDL (only in ESF mode) to be used for management. Learning mode can also be enabled so the unit can “learn” its IP configuration from the connected DSLAM to be used for its FDL management. Once it learns this information from, for example a Total Access 4303, the configuration items populate. The factory default is ON.SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > LINK IP ADDRESSThis is the local IP address used for FDL management. The FDL uses a separate IP network for communication, distinct from the customer data that is configured under the ROUTER menus. The factory default is 0.0.0.0.SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > IP NETMASKThis is the subnet mask defining the IP network used for FDL management. The factory default is 0.0.0.0.SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > FAR-END IP ADDRESSThis is the far-end IP address used for the FDL management. The FDL is a separate IP network from the customer data that is configured under the ROUTER menus. The FAR-END IP ADDRESS is generally the management IP from the DSLAM. The factory default is 0.0.0.0.SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > LEARN ADDRESSWhen set to ON, the destination address on each received packet is assumed to be the FDL interface address. A 255.255.255.254 netmask is used, which determines the far-side address as well (since there can be only two addresses on a subnet with that netmask). When set to OFF, the user must input the IP address assigned to the FDL interface. Default is ON.SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > ACCEPT ALL SNMPWhen set to ON, SNMP gets/sets received over the FDL link are always accepted regardless of the community table. When set to OFF, the community table is searched for valid manager IP addresses and the SNMP traffic is rejected if a match is not found. Default is ON.SYSTEM CONFIG > MANAGEMENT > FDL MANAGEMENT > MTU(Maximum Transmit Unit) Defines the largest packet size sent over the FDL. All packets greater in size than the MTU are fragmented.SYSTEM CONFIG > SYSLOGConfigure the unit Syslog client for use with a Syslog server (supplied with ADTRAN Utilities or available on most Unix platforms) from this menu.

For additional information, reference RFC3164: The BSD Syslog Protocol.

61200624L1-1B

© 2004 ADTRAN, Inc.

57

Section 4 User Interface Guide

Total Access 600 Series System Manual

SYSTEM CONFIG > SYSLOG > SYSLOG IPIP address of the syslog daemon to which log message should be sent. The values must be dotted decimal notation.SYSTEM CONFIG > SYSLOG > SYSLOG FORMATThe SYSLOG FORMAT is the format of log messages. “ADTRAN” uses a format that is compatible with ADTRAN Utilities and forces the Syslog Facility to LOCAL0. UNIX uses the traditional Unix format and reports at the configured facility level.

ADTRAN Utilities may malfunction if messages are received in the Unix format.

SYSTEM CONFIG > SYSLOG > SYSLOG FACILITYThe choices are: LOCAL0, LOCAL1, LOCAL2, LOCAL3, LOCAL4, LOCAL5, LOCAL6, LOCAL7. SYSLOG FACILITY is the facility level for all messages forwarded from the unit to the syslog server. This allows all messages received from the IAD to be filtered by facility level. See RFC3164: The BSD Syslog Protocol.This does not have to correspond to the facility level shown in the terminal mode option. See SYSLOG using Terminal Mode on page 59.The remaining Syslog parameters have the following level choices:FATAL (Highest priority) ALERT CRITICAL ERROR WARNING NOTICE INFO DEBUG (Lowest priority)Every log message generated by the IAD has a reporting level priority. If the message priority is lower than the configured priority for the destination log, the message is not forwarded to the syslog daemon. See RFC3164: The BSD Syslog Protocol. The lower the log level, the more messages that will be generated. Setting reporting levels to DEBUG may negatively affect the performance of the IAD, including causing the IAD to reset.ADTRAN recommends using DEBUG for only short periods of time, and for debug purposes only.

58

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

SYSLOG using Terminal ModeAnother option for configuring syslog is using the terminal mode command log dump <logname>. The logname must be all CAPS must match the listings below. The command will dump all messages for the indicated log (ALL LEVEL shows all log messages) stored in the internal log buffer to the command line display.SYSTEM CONFIG > SYSLOG > ALL LEVELThis entry allows setting the default reporting level for all log entries. If ALL LEVEL is a lower priority than the individual log entry level, ALL LEVEL overrides the individual log reporting level.SYSTEM CONFIG > SYSLOG > KERNEL LEVELMinimum required level for sending KERNEL log messages. Kernel messages provide low-level status information concerning the operation of the unit.SYSTEM CONFIG > SYSLOG > DHCP LEVELMinimum required level for sending DHCP log messages. DHCP log messages provide status information on IP addressing information concerning the DHCP server or clients.SYSTEM CONFIG > SYSLOG > NTP LEVELMinimum required level for sending NTP log messages. Network Time Protocol log messages provide information regarding the network time settings.SYSTEM CONFIG > SYSLOG > TFTP LEVELMinimum required level for sending TFTP log messages. TFTP log messages provide status information concerning firmware upgrades and configuration transfers utilizing the TFTP protocol.SYSTEM CONFIG > SYSLOG > TELNET LEVELMinimum required level for sending TELNET log messages.Telnet log messages provide status information concerning telnet requests and connections to the unit.SYSTEM CONFIG > SYSLOG > IP LEVELMinimum required level for sending IP log messages. IP log messages provide information concerning IP packets that are sent and received to and from the unit.SYSTEM CONFIG > SYSLOG > PPP LEVELMinimum required level for sending PPP log messages. PPP log messages provide status information concerning PPP packets and connections through the system.SYSTEM CONFIG > SYSLOG > NAT LEVELMinimum required level for sending NAT log messages. NAT log messages provide status information concerning Network Address Translation being performed by the system.

61200624L1-1B

© 2004 ADTRAN, Inc.

59

Section 4 User Interface Guide

Total Access 600 Series System Manual

SYSTEM CONFIG > SYSLOG > ARP LEVELMinimum required level for sending ARP log messages. Address Resolution Protocol log messages provide status information for all ARP requests sent and received by the unit.SYSTEM CONFIG > SYSLOG > UDP LEVELMinimum required level for sending UDP log messages. UDP log messages provide status information concerning UDP packets sent and received by the system.SYSTEM CONFIG > SYSLOG > NETWRITE LEVELThis parameter is for ADTRAN internal use only.SYSTEM CONFIG > SYSLOG > TCP LEVELMinimum required level for sending TCP log messages. TCP log messages provide status information concerning TCP packets sent and received by the system.SYSTEM CONFIG > SYSLOG > COMPSYS LEVELThis parameter is for ADTRAN internal use only.SYSTEM CONFIG > SYSLOG > CONSOLE LEVELThis parameter is for ADTRAN internal use only.SYSTEM CONFIG > SYSLOG > CFGXFER LEVELMinimum required level for sending configuration transfer log messages. Configuration transfer log messages provide status information on all attempted configuration transfers.SYSTEM CONFIG > SYSLOG > ROUTER LEVELMinimum required level for sending router log messages. Router messages may provide status information on routing functions within the unit.SYSTEM CONFIG > SYSLOG > NONVOL LEVELMinimum required level for sending nonvolatile memory log messages. Nonvol messages may provide status information when the flash memory is accessed (to either store or read data).SYSTEM CONFIG > SYSLOG > NOKIA LEVELMinimum required level for sending log messages about communication with the Nokia DSLAM. Messages are only generated for products with an SDSL WAN interface.SYSTEM CONFIG > SYSLOG > AUTOBAUD LEVELMinimum required level for sending log messages about communication with the Lucent Stinger DSLAM. Messages are only generated for products with an SDSL WAN interface.

60

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

SYSTEM CONFIG > SYSLOG > TOLLBRG LEVELMinimum required level for sending log messages about communication with the Tollbridge Voice Gateway. Messages are only generated for ATM products.SYSTEM CONFIG > SYSLOG > CMCP LEVELMinimum required level for sending log messages about communication with the CopperMountain DSLAM. Messages are only generated for ATM products.SYSTEM CONFIG > SYSLOG > SDSL LEVELThis parameter is for ADTRAN internal use only.SYSTEM CONFIG > SYSLOG > L1 LEVELMinimum required level for sending log messages about WAN physical or Layer 1 connection. Layer 1 messages provide status and alarm information on the state of the physical interface (for example, up or down).SYSTEM CONFIG > SYSLOG > ETH LEVELMinimum required level for sending log messages about Ethernet physical connection. These status messages provide information concerning data packets transmitted and received on the 10/100BASET interface.SYSTEM CONFIG > SYSLOG > ICMP LEVELMinimum required level for sending ICMP log messages. ICMP log messages provide information for ICMP packets sent and received by the system.SYSTEM CONFIG > SYSLOG > CONFIG LEVELThis parameter is for ADTRAN internal use only.SYSTEM CONFIG > SYSLOG >DS0 LEVELMinimum required level for sending log messages about DSO mapping.SYSTEM CONFIG > SYSLOG > SELFTEST LEVELMinimum required level for sending log messages about selftest.SYSTEM CONFIG > SYSLOG > VOICE LEVELMinimum required level for sending log messages about AAL2 voices services. Messages are only generated for ATM products.SYSTEM CONFIG > SYSLOG > JETSTREAM LEVELMinimum required level for sending log messages about communication with the JetStream Voice Gateway. Messages are only generated for ATM products.

61200624L1-1B

© 2004 ADTRAN, Inc.

61

Section 4 User Interface Guide

Total Access 600 Series System Manual

SYSTEM CONFIG > SYSLOG > POTS LEVELMinimum required level for sending log messages about POTS line cards and services.SYSTEM CONFIG > SYSLOG > LESCAS LEVELMinimum required level for sending messages about communication with LESCAS compatible Voice Gateways. Messages are only generated for ATM products.SYSTEM CONFIG > SYSLOG > ATM LEVELMinimum required level for sending ATM log messages. Messages are only generated for ATM products.SYSTEM CONFIG > SYSLOG > COPPERCOM LEVELMinimum required level for sending log messages about communication with the CopperCom Voice Gateway. Messages are only generated for ATM products.SYSTEM CONFIG > SYSLOG > VOFR LEVELMinimum required level for sending voice-over-frame-relay log messages about communication with the CopperMountain DSLAM. Messages are only generated for ATM products.SYSTEM CONFIG > SYSLOG > XMODEM LEVELMinimum required level for sending XMODEM log messages for firmware and configuration transfers.SYSTEM CONFIG > SYSLOG > EMWEB LEVELThis parameter is for ADTRAN internal use only.SYSTEM CONFIG > SYSLOG > FRELAY LEVELMinimum required level for sending frame relay log messages. Frame Relay log messages provide information for frame relay packets sent to and from the unit as well as link status information.SYSTEM CONFIG > SYSLOG > BRIDGE LEVELMinimum required level for sending bridge mode log messages. Bridge log messages provide status information for bridging process being performed by the unit.SYSTEM CONFIG > SYSLOG > MAINT LEVELMinimum required level for sending CRAFT port log messages. Craft messages provide information concerning the operation of the CRAFT interface.SYSTEM CONFIG > SYSLOG > HDLC LEVELMinimum required level for sending low level HDLC log messages. HDLC log messages provide status information concerning HDLC processes performed by the unit (sent and received packets, etc.).

62

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

SYSTEM CONFIG > SYSLOG > VOATM LEVELMinimum required level for sending Voice-over-ATM log messages. VoATM messages provide status information concerning the FXS (or FXO for Total Access 624 units only) voice signaling occurring over the ATM link.SYSTEM CONFIG > SYSLOG > PPPOA LEVELMinimum required level for sending PPP-over-ATM log messages. PPPoA log messages provide status information concerning PPP packets being sent and received over the ATM link.SYSTEM CONFIG > SYSLOG > FDL LEVELMinimum required level for sending FDL log messages. FDL log messages provide status information concerning the operation of the FDL link.SYSTEM CONFIG > SYSLOG > FILTERMinimum required level for sending Filter log messages.SYSTEM CONFIG > NETWORK TIMEActivate the network time and configure the server type, time zone and various other network time parameters from this menu.SYSTEM CONFIG > NETWORK TIME > SERVER TYPEThe unit time can be entered manually from the SYSTEM INFO menu, or the unit can receive time from an NTP/SNTP server. The NETWORK TIME menu includes all parameters relating to how the unit communicates with the time server. The server type defines the port on which the unit will listen to receive timing information from the time server. The choices are NT TIME and SNTP. When set to NT TIME, the unit will receive time from an NT server running SNTP software on its TIME port. When set to SNTP, the unit will receive time directly from an SNTP server. The factory default is SNTP.SYSTEM CONFIG > NETWORK TIME > ACTIVEThis network timing feature can be turned on and off. It determines whether the unit will request and receive time from a time server. The factory default is NO.SYSTEM CONFIG > NETWORK TIME > TIME ZONEAll time zones are based off of Greenwich Mean Time (GMT). The choices are listed below.·GMT ·GMT -5 (EASTERN) ·GMT -6 (CENTRAL) ·GMT -7 (MOUNTAIN) ·GMT -8 (PACIFIC) ·GMT -9 (ALASKA) ·GMT -10 (HAWAII)The factory default is GMT-6 (CENTRAL).

61200624L1-1B

© 2004 ADTRAN, Inc.

63

Section 4 User Interface Guide

Total Access 600 Series System Manual

SYSTEM CONFIG > NETWORK TIME > ADJUST FOR DAYLIGHT SAVINGSince some areas of the world use Daylight Savings Time, the unit is designed to adjust the time on the first Sunday in April and the last Sunday in October accordingly if this option is turned on. The factory default is YES.

SYSTEM CONFIG > NETWORK TIME > HOST ADDRESSThis is the IP address of the time server that the unit will request and receive time from. The factory default is no entry in the host address field.

SYSTEM CONFIG > NETWORK TIME > REFRESHThis is the interval of time between each request the unit sends out to the time server. A smaller refresh time guarantees that the unit receives the correct time from the server and corrects possible errors more quickly. This may be more taxing on the machine. A range of refresh times is available for the user to decide which is best for their unit. Choices include 5 MINS, 10 MINS, 15 MINS, 20 MINS, 25 MINS, 30 MINS, 35 MINS, 40 MINS, 45 MINS, 50 MINS, 55 MINS, and 60 MINS. The factory default is 60 MINS.

SYSTEM CONFIG > NETWORK TIME > STATUSThis displays the current status of the time negotiation process. If an error is displayed, check all connections and configurations to try to resolve the problem.

SYSTEM UTILITYUse the SYSTEM UTILITY menu to view and set the system parameters shown in Figure 5.

Figure 5. System Utility Menu

64

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

SYSTEM UTILITY > UPGRADE FIRMWARESelect the firmware upgrade method and perform upgrade from this menu.SYSTEM UTILITY > UPGRADE FIRMWARE > TRANSFER METHODThe customer can update firmware when unit enhancements are released. The two methods for upgrading are XMODEM and TFTP. (See the DLP section of this manual for more information.) TFTP requires a TFTP server running on the network. The unit starts a TFTP client function which gets the upgrade code from the TFTP server. Selecting XMODEM will load the upgrade code through the CRAFT port using any PC terminal emulator with XMODEM capability. The factory default is TFTP.SYSTEM UTILITY > UPGRADE FIRMWARE > TFTP SERVER ADDRESSThis is required when the transfer method is TFTP. It is the IP address or domain name (if DNS is configured) of the TFTP server. The factory default is no entry in the TFTP SERVER ADDRESS field.SYSTEM UTILITY > UPGRADE FIRMWARE > TFTP SERVER FILENAMEThis is required when the transfer method is TFTP. It is the case-sensitive file name which contains the upgrade code. The factory default is no entry in the TFTP SERVER FILENAME field.SYSTEM UTILITY > UPGRADE FIRMWARE > TRANSFER STATUSThis appears when TFTP is used. It displays the status of the transfer as it happens. Any error or success message will be displayed here.SYSTEM UTILITY > UPGRADE FIRMWARE > START TRANSFERThis activator is used when the configurable items in this menu are complete. This will initiate the transfer for either TFTP or XMODEM upgrades.

Before using START TRANSFER, the unit should have a valid IP address, subnet mask, and default gateway (if required). See DLP-3, Setting IP Parameters, for more information.

SYSTEM UTILITY > UPGRADE FIRMWARE > ABORT TRANSFERUse this activator to cancel any TFTP transfer in progress.SYSTEM UTILITY > CONFIG TRANSFERSelect the config transfer method and perform the transfer from this menu. Sends a binary file containing the unit configuration to a PC connected to the CRAFT port using XMODEM protocol or to a file on a TFTP server using the TFTP protocol.CONFIG TRANSFER also lets you save the unit configuration as a backup file, so you can use the same configuration with multiple units. In addition, CONFIG TRANSFER can retrieve a configuration file from a TFTP server.

61200624L1-1B

© 2004 ADTRAN, Inc.

65

Section 4 User Interface Guide

Total Access 600 Series System Manual

To support these transfers, ADTRAN delivers a TFTP program with the unit called TFTP Server. You can configure any PC running Microsoft Windows with this software, and store a configuration file.

Before using START TRANSFER, the unit should have a valid IP address, subnet mask, and default gateway (if required). See DLP-3, Setting IP Parameters, for more information.

Only one configuration transfer session (upload or download) can be active at a time. XMODEM and TFTP are supported.SYSTEM UTILITY > CONFIG TRANSFER > TRANSFER METHODThe two methods for transferring a file are XMODEM and TFTP. (See the DLP section of this manual for more information.) TFTP requires a TFTP server running on the network. The unit starts a TFTP client function which gets the configuration file from the TFTP server or saves the existing configuration to the TFTP server. Selecting XMODEM will load the configuration file or save the file through the CRAFT port using any PC terminal emulator with XMODEM capability. The factory default is TFTP.SYSTEM UTILITY > CONFIG TRANSFER > TFTP SERVER IP ADDRESSSpecifies the IP address of the TFTP server. Get this number from your system administrator. If using the ADTRAN Utilities TFTP server, this number appears in the TFTP server status window. The factory default value is 0.0.0.0.SYSTEM UTILITY > CONFIG TRANSFER > TFTP SERVER FILENAMEDefines the name of the configuration file that you transfer to or retrieve from the TFTP server. The default name is ta_iad.cfg, but you can edit this name.SYSTEM UTILITY > CONFIG TRANSFER > CURRENT TRANSFER STATUSIndicates the current status of the update.SYSTEM UTILITY > CONFIG TRANSFER > PREVIOUS TRANSFER STATUSIndicates the status of the previous update.SYSTEM UTILITY > CONFIG TRANSFER > LOAD AND USE CONFIGRetrieves the configuration file specified in the TFTP SERVER FILENAME field from the server. To start this command, enter Y to begin or enter N to cancel.SYSTEM UTILITY > CONFIG TRANSFER > SAVE CONFIG REMOTELYSaves the configuration file specified in TFTP SERVER FILENAME to the server identified in TFTP SERVER IP ADDRESS. To start this command, enter Y to begin or enter N to cancel.Before using this command, you must have identified a valid TFTP server in TFTP SERVER IP ADDRESS.

66

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

SYSTEM UTILITY > SYSTEM UTILIZATIONView the CPU utilization stats from this menu.

SYSTEM UTILITY > SYSTEM UTILIZATION > PERFORMANCEClear the system utilization stats and view the total and current CPU utilization stats from this menu.

SYSTEM UTILITY > SYSTEM UTILIZATION > PERFORMANCE > CPU UTILIZATIONProvides maximum CPU utilization percentages for the following intervals:

FROM POWER-UP LAST SECOND FROM LAST CLEAR

Max CPU utilization since the last Total Access 600 Series restart.Max CPU utilization in the last second. This is the most current CPU utilization information.Max CPU utilization since the last manual clear of the performance statistics using the CLEAR STATS command.

SYSTEM UTILITY > SYSTEM UTILIZATION > PERFORMANCE > ISR UTILIZATIONISRs are interrupt service routines used within the unit for operational tasks. ISR Utilization provides information concerning the amount of time spent completing these processes. ISR Utilization information is only available for 3rd Gen systems and will always show 0 on 2nd Gen units.FROM LAST CLEAR ISR utilization since the last manual clear of the performance statistics using the CLEAR STATS command.

ISR information provides useful statistics for ADTRAN’s Technical Support group but are not intended for interpretation by the general audience.SYSTEM UTILITY > SYSTEM UTILIZATION > PERFORMANCE > MAX INTERRUPT DURATION (µS)Longest time that has been spent processing an interrupt, in microseconds.SYSTEM UTILITY > SYSTEM UTILIZATION > PERFORMANCE > MAX ISR DURATION #1-3 (µS)Longest times (top 3) spent in an interrupt routine, in microseconds.SYSTEM UTILITY > SYSTEM UTILIZATION > PERFORMANCE > MAX ISR DURATION #1-3 (ID)Process IDs of the interrupts with the longest processing times (top 3).

61200624L1-1B

© 2004 ADTRAN, Inc.

67

Section 4 User Interface Guide

Total Access 600 Series System Manual

SYSTEM UTILITY > SYSTEM UTILIZATION > PERFORMANCE > CLEAR STATSThis activator will clear all the system utilization performance stats.SYSTEM UTILITY > PINGActivate the ping test and define the ping packet characteristics from this menu.SYSTEM UTILITY > PING > START/STOPActivator to start and cancel a ping test.

Only one ping session can be active at a time.

Diagnostic features such as ping, extended ping, traceroute, extended traceroute, and Telnet client can also be performed via TERMINAL MODE (see page 69).SYSTEM UTILITY > PING > HOST ADDRESSIP address or domain name (if DNS is configured) of device to receive the ping. The factory default is no entry in the host address field.SYSTEM UTILITY > PING > SIZE (40-1500)Total size of the ping to send. Range is 40 to 1500 bytes. The default is 64.SYSTEM UTILITY > PING > # OF PACKETSTotal packets to send. Setting this to 0 allows the client to ping continuously. The default is 5.SYSTEM UTILITY > PING > # TRANSMITSTotal packets sent (read only).SYSTEM UTILITY > PING > # RECEIVESTotal packets received (read only).SYSTEM UTILITY > PING > % LOSSPercentage loss based on ping returned from host (read only).SYSTEM UTILITY > TRACEROUTEUtility program used to trace a data path to a final destination.

68

© 2004 ADTRAN, Inc.

61200624L1-1B

Total Access 600 Series System Manual

Section 4 User Interface Guide

SYSTEM UTILITY > TRACEROUTE > TRACE TARGETSpecifies the IP address of the remote system to trace the routes to.SYSTEM UTILITY > TRACEROUTE > MAXIMUM HOPSSpecifies the maximum number of router exchanges allowed when traveling to the final destination (specified using the TRACE TARGET field) Range is 1 to 30. Default is 30.SYSTEM UTILITY > TRACEROUTE > TIMEOUT (IN SECS)Specifies the maximum delay (in seconds) given to a host (along a path to the final destination) to respond to the probe datagram sent before considering the packet a failure.SYSTEM UTILITY > TRACEROUTE > RETRIESSpecifies the number of times the probe datagram is sent to each host (along the path to the final destination).SYSTEM UTILITY > TRACEROUTE > BEGIN TRACEROUTEActivates the traceroute process.SYSTEM UTILITY > RESET UNITSelecting this activator will initiate a soft reset of the unit.SYSTEM UTILITY > TERMINAL MODESelecting the terminal mode gives the user a command-line prompt to perform utilities such as pings, traceroutes, resets, firmware updates, configuration, and more. TERMINAL MODE can also be accessed by using the shortcut keys <Ctrl+T> from other menu screens. From this command-line prompt, you can: · Perform a reset with the command “reset” · Perform a complete factory restore with the command “factory_reset” · Configure the unit. The unit has the ability to download a text file which contains the configuration ofthe entire unit. This configuration may then be altered in a text editor, and then uploaded to a unit. (See DLP-13, Saving and Loading Text Configuration using Terminal Command Line, for further assistance.) · Debug and troubleshoot. This function would be carried out with the assistance of ADTRAN Technical Support. · Start and stop the fail-safe timer for the auto-config feature. · Perform a firmware upgrade via TFTP.upgrade_firmware hostname filename · Use the save command to write the entire configuration to flash. · Display the unit’s MAC address with the command mac. · Perform a ping or extended ping. Syntax is:ping hostname/address [repeat xx] [size xx] [timeout xx] [source xx] [noNat]

61200624L1-1B

© 2004 ADTRAN, Inc.

69

Section 4 User Interface Guide

Total Access 600 Series System Manual

Options: repeat <repeat count> size (datagram size) timeout (seconds) source (address or name) noNat

Number of pings to send (default 5) Range is 40-1500 Timeout in seconds (range 1-10) Source address or interface name to use Do not NAT the ping packet

Options may be entered in any order and may be truncated.

Valid interface names are eth0, fdl0, ppp0, fr0, fr1, etc.

Example usage: ping 10.0.0.5 r 10 si 1500 so eth0 n

This will ping with a repeat count of 10. The datagram size is 1500 bytes, and the source address used in the ping packet will be the Ethernet IP address. The “noNat” option has been specified, so if NAT is enabled, this packet will NOT be translated.

· Perform a traceroute or extended traceroute. Syntax is:

traceroute hostname/address [hops xx] [timeout xx] [retries xx] [source xx] [noNat]

Options: hops <hops count> timeout <seconds> retries <seconds> source <address or name> noNat

Max number of hops (default 30) Timeout in seconds (default 3) Number of retries per hop (default 3) Source address or interface name to use Do not NAT the trace packets

Options may be entered in any order and may be truncated.

Valid interface names are eth0, fdl0, ppp0, fr0, fr1, etc.

Example usage: trace 10.0.0.5 h 20 t 1 r 1 so eth0

report this ad

This will perform a trace to 10.0.0.5 with a max hop count of 20. The timeout for each hop is 1 second, and the retry count per hop is 1. The Ethernet IP w

References

[xyz-ips snippet=”download-snippet”]