NetWay8V Midspan PoE Injector
Power over the Ethernet
NetWay V SeriesPoE Solution for Standard Network InfrastructureModels Include:NetWay8V– Eight (8) Port PoE Midspan InjectorNetWay16V– Sixteen (16) Port PoE Midspan InjectorInstallation Guide
Rev. 071609
More than just power.TM
Installing Company: _______________ Service Rep. Name: __________________________________
Address: _____________________________________________ Phone #: __________________
Overview:Altronix NetWay8V/NetWay16V Midspans provide power and pass data for PoE compliant cameras/edge devices. Cameras/edge devices may be located up to 100m from the NetWay unit. A NetWayXT/NetWayXTX repeater module can be utilized to extend the distance an additional 100m for a total range of up to 200m. A maximum range of 600m is possible using multiple repeaters, based on camera/device port requirement. NetWay Midspans are capable of supporting non-PoE compliant fixed and PTZ IP cameras utilizing NetWay1512 or NetWay3012 adapters.
NetWay Specifications:
NetWay8:
· Eight (8) ports of cameras/edge devices over ethernet (CAT5) cable up to a distance of 100m per port.
· Input: 220VAC 50/60Hz, 1.8A.
NetWay16:
· Sixteen (16) ports of cameras/edge devices over ethernet (CAT5) cable up to a distance of 100m per port.
· Input: 220VAC 50/60Hz, 2.5A
.Common Specifications:
Agency Listings:
Features (cont’d):
· CE
European Conformity.
· Individual port status LEDs.
Power:
· IEC 320 – 3-wire grounded line cord (detachable).
· Unit supplies PoE output voltage (55V), and up to · Unit can be rack or shelf mounted.
30W max. full power per port.
· 1U rack mount chassis for use in standard
Total power:
NetWay8V – 150W,
EIA 19″ rack.
NetWay16V – 300W. · IEEE 802.3af (PoE) andIEEE 802.3at (PoE+) compliant. · All output circuits are power-limited. · Short circuit protection.Functions:
Accessories: NetWay1512: · 15W adapter for non-PoE compliant IP cameras. NetWay3012: · 25W adapter for non-PoE compliant IPfixed or PTZ cameras.
· Auto detection and protection of legacy
NetWayXT:
non-PoE cameras/edge devices.
· PoE repeater module extends range 100m.
Features:
NetWayXTX:
· Illuminated master power disconnect circuit
· PoE+ repeater module extends range 100m.
breaker with manual reset (switch).
Installation Instructions:NetWay is not intended to be connected to outside plant leads. 1. Attach mounting brackets to NetWay unit for rack installation (Fig. 6, pg. 8).Affix rubber pads to NetWay for shelf installation (Fig. 8, pg. 7). 2. Secure the unit in a rack or place unit on a shelf as desired.Note: The following factors should be taken into consideration when installing these rack mount units: a. The unit is to be installed in a space where the maximum ambient temperature does not exceed 104ºF (40ºC). b. Take care to ensure that there is sufficient air flow around the unit and that obstructions do not impede it. c. When mounting units in rack, take care to avoid uneven loading which can cause a hazardous condition. 3. Set illuminated master power disconnect circuit breaker to the (OFF) position (Fig. 1d, pg. 3). 4. Plug the grounded AC line cord (included) into the IEC 320 connector of the NetWay unit (Fig. 1e, pg. 3). Plug unit into a reliable earth grounded socket. When using multiple units, the sum of the individual name plate ratings should not exceed the supply circuit rating. Do not connect to a receptacle controlled by a switch. 5. Connect structured cables from port marked [IN] on NetWay to the corresponding inputs of an ethernet switch or video server (Fig. 1b, pg. 3, Fig. 5, pg. 6). 6. Connect structured cables from port marked [OUT] on NetWay to PoE compliant camera/edge devices (Fig. 1a, pg. 3, Fig. 5, pg. 6). 7. Upon completion of wiring set illuminated master power disconnect circuit breaker to the RESET (ON) position (Fig. 1d, pg. 3). 8. Port status LEDs on the NetWay will initialize when PoE devices are connected as follows: – LED will illuminate when devices are IEEE 802.3af compliant. – LED will blink once and illuminate when devices are IEEE 802.3at compliant (PoE+).
– 2 –
NetWay8V / NetWay16V Installation Guide
Port Status and LED Flash Codes:
Port Status All Ports Off Port Off Port On Class 4 detection Port Non-compliant Device Port Overload Fault
Flash Codes Sequential LED Port ScanOFF ON Blinks 2 times 2Hz 5Hz
Description No devices connectedLED OFF LED ON Enables power to PoE devices. Will prevent port from turning on. Will prevent port from turning on.
4 Port Overload Grouped
5Hz
4 LEDs Will prevent ports from turning on.
8 Port Overload Grouped
5Hz
LED’s 1-8 Power Supply Overload for ports 1-8. LED’s 9-16 Power Supply Overload for ports 9-16.
Fig. 1 – NetWay8V/NetWay16V Configuration NetWay8V – Front Panel
NetWay16V – Front Panel 1a
1b
1c
NetWay8V & NetWay16V – Rear PanelAC POWER1d 1e1a OUT 1-8 (NetWay8V), OUT 1-16 (NetWay16V): Structured cable to PoE compliant cameras/edge devices. 1b IN 1-8 (NetWay8V), IN 1-16 (NetWay16V): Structured cable to ethernet switch or video server. 1c LED(s) 1-8 (NetWay8V), 1-16 (NetWay16V): Port status LEDs. 1d Illuminated master power disconnect circuit breaker (switch):· OFF position Circuit breaker tripped. Switch not illuminated. · RESET (ON) position. Switch illuminated. 1e IEC 320 Connector: 115VAC 60Hz (grounded line cord included).
NetWay8V / NetWay16V Installation Guide
– 3 –
Installing a NetWay1512 Adapter for 12VDC IP Cameras up to 13W:
Brooklyn, NY, U.S.A.
Fig. 2 – NetWay1512
Netway1512Adapterwww.altronix.com
IN
OUT
I.T.E. 43KC12VDC + Output —
Structured Cable from NetWay
Structured Cable from IP Camera/Device
— + 12VDC OutputPower LED
1. Mount NetWay1512 in proximity to IP camera (Fig. 2, pg. 4). Affix one side of velcro (supplied) to NetWay1512 and the place the second side of the velcro in the desired location.2. Connect structured cable from port marked [IN] on NetWay1512 to any ports marked [OUT] of NetWay8/NetWay16 (Fig. 2, pg. 4, Fig. 1a, pg. 3).3. Connect structured cable from port marked [OUT] on NetWay1512 to the IP camera (Fig. 2, pg. 4). 4. Connect 12VDC output from NetWay1512 terminals marked [ 12VDC +] to the power input of theIP camera (Fig. 2, pg. 4). Polarity must be observed. 5. Power LED indicator will illuminate on NetWay1512 under normal conditions (Fig. 2, pg. 4). Installing a NetWay3012 Adapter for 12VDC IP PTZ up to 25W:
Fig. 3 – NetWay3012
Brooklyn, NY, U.S.A.
Netway3012Adapter
I.T.E. 43KC
Structured Cablefrom NetWay8 or NetWay16
+ -12VDC Power to Camera
www.altronix.com
12VDC
IN
OUT
+ Output —
Structured Cable fromIP Camera
Power LED
1. Mount NetWay3012 in proximity to IP camera utilizing mounting hole (Fig. 3, pg. 4). Use a proper fastener and/or wall anchor when securing NetWay3012 to the wall.2. Connect structured cable from port marked [IN] on NetWay3012 to ports marked [OUT] of NetWay8/NetWay16 (Fig. 3, pg. 4, Fig. 1a, pg. 3).3. Connect structured cable from port marked [OUT] on NetWay3012 to the IP fixed or PTZ camera (Fig. 3, pg. 4).4. Connect 12VDC output from NetWay3012 terminals marked [+ 12VDC ] to the power input of the IP camera (Fig. 3, pg. 4). Polarity must be observed.5. Power LED indicator will illuminate on NetWay3012 under normal conditions (Fig. 3, pg. 4).
– 4 –
NetWay8V / NetWay16V Installation Guide
Installing a NetWayXT/NetWayXTX Repeater Module:
Brooklyn, NY, U.S.A.
NetWayXT
Fig. 4 – NetWayXT/NetWayXTX
NetwayXTRepeater
I.T.E. 43KC
www.altronix.com
Power
OUT
IN
Power LED
Structured Cable from NetWay8/16Structured Cable to IP Camera/Edge Device or next NetWayXT
NetWayXTX
Structured Cable from NetWay8/16
PoE/PoE+ Output LED
Structured Port Status
Cable to
LEDs
PoE/PoE+
Camera/Device or
next NetWayXTX
PoE/PoE+ Input LED
NetWayXT will work only with PoE devices. NetWayXTX will work with PoE/PoE+ devices. 1. Mount NetWayXT/NetWayXTX in desired location utilizing the mounting hole (Fig. 4, pg. 5). Use a properfastener and/or wall anchor when securing NetWayXT/NetWayXTX to the wall. 2. Connect structured cable from port marked [OUT] on NetWay to port marked [IN] on the NetWayXT/NetWayXTX(Fig. 4, pg. 5, Fig. 1a, pg. 3). 3. Connect structured cable from port marked [OUT] on NetWayXT/NetWayXTX to the PoE/PoE+ camera/edgedevice or next NetWayXT/NetWayXTX repeater (Fig. 4, pg. 5). 4. Port status LEDs will illuminate on NetWayXT/NetWayXTX indicating the port is operational(refer to LED Definitions). 5. Power LED will illuminate indicating 12VDC output.
Port LED Definitions for NetWayXT Repeater:
Status
Green LED
OFF
Indicates it is connected as 10Base-T or no link.
ON
Indicates it is connected as 100Base-TX.
Blinking
Yellow LED Indicates no link. Indicates a link. Indicates activity.
Port LED Definitions for NetWayXTX Repeater:
Status
PoE/PoE+ Output LED
OFF
No PoE/PoE+ Output
ON
Normal PoE/PoE+ Output
Blinking
PoE/PoE+ Input LED No PoE/PoE+ InputPoE/PoE+ Input
Yellow LED Indicates no link. Indicates a link. Indicates activity.
NetWay8V / NetWay16V Installation Guide
– 5 –
NetWay8V/NetWay16V Typical Application:Fig. 5NetWayXT/NetWayXTX Extends Ethernet 100m (328 ft.)
PoE Camera
I.T.E. 43KCNetwayXT Repeater
Power
www.altronix.com
OUT
IN
PoE Camera
Card Reader
Strike
NetWay8V
HID SoloPoE + Camera
NetWay1512
Netway1512 AdapterIN
I.T.E. 43KCwww.altronix.com
12VDC
OUT
+ Output —
12VDC IP camera
Ethernet Switch
NVR/Network Server
Parameter No. of PortsInput Power RequirementsIndicatorsEnvironmental Conditions
Technical Specifications:DescriptionNetWay8V – Eight (8) Ports. NetWay16V – Sixteen (16) Ports.NetWay8V: 220VAC, 50/60Hz, 1.8A. NetWay16V: 220VAC, 50/60Hz, 2.5A. Fuse: 4A/125V (NetWay16V has 2 fuses). Note: To reduce the risk of fire, replace only with same type and rating of fuse.Port Status LEDOperating Ambient Temperature: -20ºC to 40ºC (-4ºF to 104ºF). Relative humidity: 85%, +/- 5%. Storage Temperature: -20º to 70ºC (-4º to 158ºF). Operating Altitude: -304.8 to 3,048m.
Regulatory Compliance
CE European Conformity
– 6 –
NetWay8V / NetWay16V Installation Guide
NetWay8V/NetWay16V Rack Mount Chassis Mechanical Drawing and Dimensions:Fig. 60.75″ (19.1mm)19.125″ (485.8mm) 17.625″ (447.7mm)
8.5″ (215.9mm)
AC POWER
(ON)
1.625″ (41.3mm)
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of an insulated DANGEROUS VOLTAGE within the product’s enclosure that may be of sufficient magnitude to constitute an electric shock.The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.CAUTION: To reduce the risk of electric shock do not open enclosure. There are no user serviceable parts inside. Refer servicing to qualified service personnel.
NetWay8V / NetWay16V Installation Guide
– 7 –
Mounting Options: Rack Mount Installation1. Remove and discard factory installed screws from both sides of rack chassis (Fig. 7a). 2. Install mounting brackets (A) on the left and right side of rack chassis using the four (4) flat head screws (B)(included) (Fig. 7b). 3. Place unit into desired EIA 19″ rack position and secure with mounting screws (not included) (Fig. 7c).
Fig. 7
Fig. 7a
Fig. 7b
Fig. 7c
TopFront Left
Top Front LeftB
Top Front Left
Remove A
Wall Mount Installation1. Install mounting brackets (A) on the left and right side of rack chassis using four (4) flat head screws (B) (included) (Fig. 8a).2. Place unit at desired location and secure with #6 size screws or larger (not included) (Fig. 8b). Caution: It is necessary to make sure mounting screws are securely fastened to a beam when installing the unit vertically.
Fig. 8 Fig. 8a
Fig. 8b
B
A
Dotted lines indicate studs behind sheetrock.
Shelf Installation
1. Position and affix rubber pads (C) (included) at each corner on the bottom of the unit (Fig. 9).
2. Place unit in desired location. Fig. 9
Mounting Hardware (Included):
Left Side
A Two (2) mounting brackets
CRubber Pad
Six (6) flat head screws B for mounting brackets. C Four (4) rubber pads.
Altronix is not responsible for any typographical errors.
140 58th Street, Brooklyn, New York 11220 USA | phone: 718-567-8181 | fax: 718-567-9056
website: www.altronix.com | e-mail: info@altronix.com | Lifetime Warranty