amazon commercial EMF Meter Household Radiation Detector
IMPORTANT SAFETY INSTRUCTIONS
Read these instructions carefully and retain them for future use. If this product is passed to a third party, then these instructions must be included.When using electrical appliances, basic safety precautions should always be followed to reduce the risk of fire, electric shock, and/or injury to persons including the following:
WARNING Use caution when working in the vicinity of powerful radiation sources.WARNING Persons with electronic implants (e.g. cardiac pacemakers) should avoid powerful radiation sources.WARNING Carefully read the operating instructions for equipment generating or conducting electromagnetic energy that will be measured.WARNING Do not operate near combustible gases or in damp environments.
- This product must be used by trained users only.
- Do not use if the product appears damaged or if it is not working properly. If in doubt, replace the product.
- Do not operate the product after a low battery warning was triggered. Replace the battery immediately.
- Field strength measurement devices can underrate pulsed signals, particularly with radar signals, in which case significant measurement errors can result.
- Be aware that the field strength in the near vicinity of radiators increases proportionally to the inverse cube of the distance. This means that enormous field strengths can result in the immediate vicinity of small radiation sources (e.g. leaks in wave guides or inductive ovens).
- All field strength measuring devices have a limited specified frequency range. Fields with spectral components outside of this frequency range are generally incorrectly evaluated and tend to be underrated. Before using field strength measuring devices be certain that all field components to be measured lie in the specified frequency range of the measuring device.
- The accuracy and function of the product may be adversely affected if the specified limits are exceeded or if the product is handled improperly.
- Do not attempt repairs. There are no user serviceable parts.
Battery Warnings
- Exhausted batteries should be immediately removed from product and properly disposed.
- Keep batteries out of the reach of children.
- Do not dispose of batteries in fire.
- Remove batteries from product if it is not to be used for an extended period of time.
- If the battery leaks avoid contact with skin and eyes. Rinse affected areas immediately with plenty of clean water, then consult a doctor.
This manual contains important safety and operating instructions for power units.
Explanation of Symbols
The signal word that indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. | |
The signal word that indicates a hazard that if not prevented could result in minor or moderate injury. | |
Indicates a practical tip, advice or practice not related to personal injury. | |
Risk of electric shock! This symbol indicates that, under normal use, hazardous voltages may be present. | |
This symbol stands for “Conformité Européenne”, which means “Conformity with EU-directives”. With the CE marking the manufacturer confirms that this product complies with applicable European directives and regulations. | |
Product is protected by double insulation or reinforced insulation. | |
This product is for indoor use only. | |
Plus (+) and minus (-) polarity marking | |
Alternating current (AC). | |
Direct current (DC). |
Product Description
(A) LED indicator(B) Display(C) /MODE button(D) On/off button /Alarm on/off(E) Battery compartment (backside)(F) TEMP/UNIT button(G) EMF sensor
Display
(H) Buzzer on/off(I) Signal scanned(J) APO mode(A) LED indicator](K) Low battery indicator(L) Measurement unit(M) Temperature unit(N) MAX/MIN/HOLD mode(E) Battery compartment (backside)(B) Display(F) TEMP/UNIT button
Intended Use
- The product measures electromagnetic fields of extremely low frequency (ELF) of 30 to 300 Hz.
- The product measures the electromagnetic field radiation levels that are produced by electric transmission equipment, power lines, microwave ovens, air conditioners, refrigerators, computer monitors, video/audio devices and similar products.
- The product is suitable for use in indoor dry areas only.
- The product was designed for use in an environment of pollution degree 2.
- No liability will be accepted for damages resulting from improper use or non-compliance with these instructions.
Operation
Switching the product on/offPress the button (D) to switch the product on. Press and hold the
Taking the measurement
- With the product in hand, move slowly towards to the object under measurement until it is physically touched.
- Notice how the field intensity increases as you move closer to the object.
- Position the EMF sensor (G) at different angles toward the object under measurement and observe the EMF signals.
Switching the alarm on/offPress the
Switching the backlight on/offPress and hold the
Switching the measurement modePress and hold the TEMP/UNIT button (F) to switch between electromagnetic and temperature measuring mode.
Switching the electromagnetic unitWhile in electromagnetic measuring mode, press the TEMP/ UNIT button (F) to switch between milli-Gauss (mG) and micro Tesla (μT). The default unit is μT.
Switching the temperature unitWhile in temperature mode, press the TEMP/UNIT button (F) to switch between °C and °F. The default unit is °C.
Switching MAX/MIN/HOLD modeWhile in electromagnetic measuring mode, press the
HOLD | use to freeze/unfreeze a measurement on the display |
MIN | use to display minimum measurement taken |
MAX | use to display maximum measurement taken |
Auto power-off (APO)To conserve battery life, the product automatically switches off after approximately 10 minutes of inactivity.
Changing Batteries
NOTICE Replace the battery if the “
- Loosen the screw on the battery compartment cover (E) and remove it.
- Replace the battery with a new 9 V battery.
- Refit the battery compartment cover (E) and tighten the screw.
Cleaning and Maintenance
Cleaning
- To clean the product, wipe with a soft, slightly moist cloth.
- Never use corrosive detergents, wire brushes, abrasive scourers, metal or sharp utensils to clean the product.
Storage
- Store the product in its original packaging in a dry area. Keep away from children and pets.
Specifications
Display | Max. reading 9999 |
Electromagnetic range: | 0 – 2000 mG or 0 – 200 uT |
Temperature range | -10 °C to 50 °C |
Frequency bandwidth | 30 Hz to 300 Hz |
Battery | 9 V battery |
Operating temperature | 5 °C to 40 °C |
Storage temperature | -10 °C to 60 °C |
Dimension (W x H x D) | approx. 16.8 x 5.8 x 4 cm |
Net weight | 165 g |
Disposal
Battery Disposal
Do not dispose of used batteries with your household waste. Take them to an appropriate disposal/collection site.
Feedback and HelpLove it? Hate it? Let us know with a customer review. AmazonCommercial is committed to delivering customer-driven products that live up to your high standards. We encourage you to write a review sharing your experiences with the product.
amazon.co.uk/review/review-your-purchases# | |
amazon.co.uk/gp/help/customer/contact-us |
References
[xyz-ips snippet=”download-snippet”]