AMTC FOAMFLO Automatic Foam Soap Dispenser ASD-500 Installation Guide

AMTC FOAMFLO Automatic Foam Soap Dispenser ASD-500 Installation Guide

Installation Diagram

Attention:Make sure sensor cable is passed through the opening of the spacer to avoid damage.

ASD-500ASD-500EL

Low Battery Indicator Flashing BLUE LED
Low Soap Indicator Flashing RED LED

 

Installation Instructions (refer to installation diagram above)

  1. If hole is not present drill a 1” (25.4mm) hole on countertop (refer to installation template on page 3).
  2. Mount the spout onto the countertop or sink and hand tighten mounting bracket and spacer without damaging sensor cable.
  3. Install batteries into battery pack and mount battery pack onto back wall using provided hardware(battery pack must be installed within 15” (380mm) of spout).Note: An optional 6 Volt AC power adapter (Part# AD05) can be purchased separately if electrical power is required.
  4. Screw soap bottle coupler onto threaded stem and hand tighten.
  5.  Fill up bottle with foam soap (Important: Use low viscosity non-lotionized foaming soap with no abrasives).
    • Viscosity Range: (mPa•s or Cp): 1-100 / pH Range: 5.5 – 8.5
    • Failure to use soap products within the required range of viscosity and pH may result in damage to product and void warranty.
  6. Screw soap bottle onto soap bottle coupler and hand tighten.
  7. Connect sensor cable onto battery pack (you will hear pumps and soap will purge for approximately 5 seconds).
  8. Soap dispenser is now ready for use.

 

Parts List

Ref #

Part #

Description

A

ASD-5SPT Spout

A-1

ASD-5SPTEL EL Spout (6” Long)

B

ASD-5FA Spout Filter Assembly

C

ASD-5SPA Spacer

D

ASD-5MB Mounting Bracket

E

ASD-5SBC Soap Bottle Coupler

F

ASD-5MSC Mounting Screws

G

ASD-5SB 800ml Soap Bottle

H

ASD-5BP Battery Pack

I

AD05 6-Volt AC Power Adapter (Optional)

J

AD05-2 6-Volt AC Power Adapter w/Extension for 2 Devices

K

AD05-2-EXT Extension Only for AC Power Adapter

(Optional-Sold Separately)(Optional-Sold Separately)(Optional-Sold Separately)

Soap Refill Instructions

  1. Flashing Red LED Indicates Low Soap
  2. Unscrew Foam Soap Bottle
  3. Refill Foam Soap BottleImportant: Use low viscosity non-lotionized foaming soap with no abrasives.
    • Viscosity Range: (mPa•s or Cp): 1-100 pH Range: 5.5 – 8.5
    • Failure to use soap products within the required range of viscosity and pH may result in damage to product and void warranty.
  4. Re-install Foam Soap Bottle
  5. Press and Hold Reset Button for 7 Seconds to Prime New Soap and Reset Flashing Red LED.

Troubleshooting

Problem

Solution

Flashing BLUE LED Batteries are low/drained. Replace all 4 batteries (D-size).
Flashing RED LED Soap is low or empty. Refill soap bottle and press and hold reset button for 7 seconds to prime new soap and reset LED.
Soap does not come out of spout Spout filter is dirty and won’t pump soap through the spout. Clean or replace spout filter assembly.
Soap dispenses in liquid form and not foam Wrong soap was used and pump is dirty. Refill soap bottle with water and press and hold reset button for 7 seconds to prime water through the unit. This should be repeated until only water dispenses and soap is completely flushed out. Once unit is flushed out, refill soap bottle with foaming soap. Prime unit again until soap comes out.

Installation Template for Model ASD-500 Spout (Not used for Model ASD-500EL)

Warranty

AMTC WARRANTS THE ASD-500 SOAP DISPENSER TO BE FREE OF DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF THREE (3) YEARS FROM DATE OF PURCHASE, WHEN PROPERLY INSTALLED AND UNDER NORMAL USE AND SERVICE. THESE PROVISIONS DO NOT INCLUDE THE BATTERIES SHIPPED WITH THE PRODUCT. A DEFECTIVE PRODUCT MAY BE RETURNED TO AMTC OR ITS AUTHORIZED REPRESENTATIVES WITHIN THREE (3) YEARS FROM DATE OF PURCHASE WITH THE PROPER INVOICE OF PURCHASE. AMTC, AT ITS DISCRETION, WILL REPLACE OR REPAIR DEFECTIVE PRODUCT AT NO CHARGE. CLAIMS FOR LABOR, TRANSPORTATION, AND ANY OTHER INCIDENTAL COSTS WILL NOT BE ALLOWED. AMTC WILL NOT BE RESPONSIBLE FOR ANY CONSIDERABLE DAMAGES OF ANY KIND WHATSOEVER.

FOR TECHNICAL SUPPORT PLEASE CALL TOLL FREE 1-800-874-7822 OR VISIT OUR WEBSITE AT WWW.AMTCORPORATION.COM.

MAKE SURE TO VISIT OUR WEBSITE PERIODICALLY FOR INFORMATION ON NEW PRODUCTS AND TO DOWNLOAD ANY IMPORTANT PRODUCT DOCUMENTS THAT YOU MAY NEED IN THE FUTURE.

Advanced Modern Technologies Corporation