Aruba Instant On AP22 Installation Guide

Aruba Instant On AP22 Installation Guide

Installation Guide

The Aruba Instant On AP22 access point delivers high performance concurrent 2.4 GHz and 5 GHz Wi-Fi 6 (802.11ax) functionality with MIMO radios (2×2 in 2.4 GHz, 2×2 in 5 GHz), while also supporting legacy 802.11a/b/ g/n/ac wireless services.

Package Contents

  •  1 x AP22 access point
  • 1 x Mount bracket
  • 1 x Ethernet cable

If you have ordered AP22 bundle, the package would also include a power supply unit to power the AP through an electrical power outlet.

Inform your supplier if there are any incorrect, missing, or damaged parts. If possible, retain the carton, including the original packing materials. Use these materials to repack and return the unit to the supplier if needed.

Hardware Overview

       Figure 1 AP22 Front View

LEDsThe AP22 access point has two LEDs that indicate the system and radio status of the device.

Table 1 AP22 Access Point LEDs Status

  LED   Color/State   Meaning
 System   No Lights   Device has no power
  Blinking Green   Device is starting
  Alternating Green/Amber   Device is ready for setup
  Solid Green   Device is ready
  Solid Amber   Device has detected a problem
  Solid Red   Device has an issue- immediate action required
  Radio   No Lights   Wi-Fi is not ready, wireless clients cannot connect
  Solid Green   Wi-Fi is ready, wireless clients can connect

                      Figure 2 AP22 Rear View

Ethernet Port

The AP22 is equipped with a 10/100/1000Base-T auto-sensing MDI/MDX Ethernet port (E0). This E0 port supports wired-network connectivity, and Power over Ethernet (PoE) from IEEE 802.3af and 802.3at compliant PoE power sources, such as a PoE midspan injector or a network switch.

Kensington Lock Slot

The AP22 access point is equipped with a Kensington lock slot for additional security.

Reset Button

The reset button located on the bottom of the device can be used to reset the access point to factory default settings.There are two ways to reset the access point to factory default settings:

Reset the AP during normal operation

Press and hold down the reset button using a small, narrow object such as a paper clip for more than 10 seconds during normal operation.

Reset the AP while powering up

  1. Press and hold down the reset button using a small, narrow object such as a paper clip while the access point is not powered on (either via DC power or PoE).
  2. Connect the power supply (DC or PoE) to the access point while the reset button is being held down.
  3. Release the reset button on the access point after 15 seconds.
Power

If PoE is not available, a proprietary Aruba power adapter can be used to power the AP22 access point. This power adapter is available in the box if you buy the AP22 and power adapter bundle. For details, refer to the ordering information in the AP22 data sheet at https://www.ArubaInstantOn.com/resources. When both PoE and DC power sources are available, the DC power source takes precedence. The access point simultaneously draws a minimal current from the PoE source. In the event that the DC source fails, the access point switches to the PoE source.

Cable Clip

The cable clip on the rear of the access point is used to organize Ethernet cable, as shown in Figure 3. The use of the cable clip is optional and does not support all types of cables and plugs.

Before You Begin

Refer to the sections below before beginning the installation processThe AP22 access point is designed in compliance with governmental requirements so that only authorizednetwork administrators can change the settings.

Identifying Specific Installation Locations

Each location should be as close as possible to the center of the intended coverage area and should be free from obstructions or obvious sources of interference. These RF absorbers/reflectors/interference sources will impact RF propagation and should have been accounted for during the planning phase and adjusted.

Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.

Identifying Known RF Absorbers/Reflectors/Interference Sources

Identifying known RF absorbers, reflectors, and interference sources while in the field during the installationphase is critical. Make sure that these sources are taken into consideration when you attach an access point to its fixed location.RF absorbers include:

  •  Cement/concrete—Old concrete has high levels of water dissipation, which dries out the concrete, allowing for potential RF propagation. New concrete has high levels of water concentration in the concrete, blocking RF signals.
  • Natural Items—Fish tanks, water fountains, ponds, and trees
  • BrickRF reflectors include:
  • Metal Objects—Metal pans between floors, rebar, fire doors, air conditioning/heating ducts, mesh windows,blinds, chain link fences (depending on aperture size), refrigerators, racks, shelves, and filing cabinets.
  • Do not place an access point between two air conditioning/heating ducts. Make sure that access points are placed below ducts to avoid RF disturbances.RF interference sources include:
  • Microwave ovens and other 2.4 or 5 GHz objects (such as cordless phones)
  • Cordless headset such as those used in call centers or lunch rooms

Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 7.87 inches (20 cm) to any part of the access point. Otherwise, degradation of the performance of this equipment could result.

Access Point Installation

The installer is responsible for securing the access point onto the ceiling tile rail in accordance with the steps below. Failure to properly install this product may result in physical injury and/or damage to property.

Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation. The AP22 access point ships with a mount bracket to install the access point to a 9/16” or 15/16” ceiling tile rail, or on a solid surface, such as a wall or a hard ceiling. The following sections provide instructions on how to use this mount bracket.

Installing the Access Point to a Ceiling Tile Rail

  1. Pull the necessary cables through a prepared hole in the ceiling tile near where the access point will be placed.
  2. Place the mount bracket against the back of the access point with the mount bracket at an angle of approximately 30 degrees to the tabs (see Figure 4).
  3. Twist the mount bracket clockwise until it snaps into place in the tabs (see Figure 4).Figure 4 Attaching the Mount Bracket to the AP
  4. Hold the access point next to the ceiling tile rail with the mounting slots at approximately a 30-degree angle to the ceiling tile rail (see Figure 5 and Figure 6). Make sure that any cable slack is above the ceiling tile.
  5. Pushing toward the ceiling tile, rotate the access point clockwise until the device clicks into place on the ceiling tile rail.Figure 6 Mounting the AP to a 9/16” Ceiling Rail

Installing the Access Point to a Solid Surface

  1.  Attach the mount bracket to any solid surface, such as a wall or hard ceiling, as shown in Figure 7.a. Install any necessary wall anchors. Wall anchors are not included in the package.b. Align the screw holes in the mount bracket with the previously installed anchors or demarcated screw pointsc. Insert two screws to secure the mount bracket. Screws are not included in the package.
  2. Attach the access point to the secured mount bracket as shown in Figure 8.a. Align the access point with the mount bracket, placing the access point so that it’s mounting tabs are at an angle of approximately 30 degrees to the mount bracket.
  3. Pushing towards the solid surface, rotate the access point clockwise until it clicks into place (see Figure 8).      Figure 8 Attaching the Access Point to the Mount Bracket

Verifying Post-Installation Connectivity

The integrated LEDs on the access point can be used to verify that the access point is receiving power and initializing successfully (see Table 1).

Mobile Application Installation

Click the Apple App Store or Google Play badge below to download and install the Aruba Instant On mobile app to your phone. Launch the app and follow the instructions to complete the setup. Alternately, simply search for “Aruba Instant On” app within Apple App Store or Google Play.

Log in to Instant On Portal

Alternately, you can set up the Aruba Instant On access point from a web browser. Open a web browser and enter https://portal.ArubaInstantOn.com in the address bar to access the Aruba Instant On portal login screen. In the login screen, enter your Instant On account credentials to access your site.

    Figure 9 Instant On Portal Login Screen

Electrical and Environmental Specifications

All Aruba access points should be professionally installed by an Aruba Certified Mobility Professional (ACMP). The installer is responsible for ensuring that grounding is available and meets applicable national and electrical codes.

Electrical

  • Ethernet:
  • E0 port: 10/100/1000BaseT auto-sensing MDI/MDX wired RJ45 network connectivity port
  • Power:
  • 12V DC power interface, support powering through AC-to-DC power adapter
  • Power over Ethernet (PoE): 802.3af or 802.3at compliant source

If a power adapter other than the Aruba-approved adapter is used in the US or Canada, it should be NRTL listed, with an output rated 12Vdc, minimum 2A, marked “LPS” and “Class 2”, and suitable for plugging into a standard power receptacle in the US and Canada.

Environmental

  • Operating temperature: 0°C to +40°C (+32°F to +104°F)
  • Operating humidity: 5% to 93% non-condensing

Regulatory Model Number

  • AP22 RMN: APIN0505

Safety and Regulatory Compliance

RF Radiation Exposure Statement: This equipment complies with FCC RF radiation exposure limits. This equipment should be installed and operated with a minimum distance of 7.87 inches (20cm) between the radiator and your body for 2.4 GHz and 5 GHz operations. This transmitter must not be co-located or operatingin conjunction with any other antenna or transmitter.

Federal Communication Commission

device may not cause harmful interference, and (2) this device must accept any interference received, includinginterference that may cause undesired operation.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in aresidential installation. This equipment generates, uses and can radiate radio frequency energy and, if notinstalled and used in accordance with the manufacturer’s instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference will not occur in a particular installation. Ifthis equipment does cause harmful interference to radio or television reception, which can be determined byturning the equipment off and on, the user is encouraged to try to correct the interference by one or more of thefollowing measures:

  • Reorient or relocate the receiving antenna.
  •  Increase the separation between the equipment and receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio or TV technician for help.
Industry Canada

This Class B digital apparatus meets all of the requirements of the Canadian Interference-Causing Equipment Regulations.

In accordance with Industry Canada regulations, this radio transmitter and receiver may only be used with an antenna, the maximum type and gain of which must be approved by Industry Canada. To reduce potential radio interference, the type of antenna and its gain shall be chosen so that the equivalent isotropic radiated power (EIRP) does not exceed the values necessary for effective communication. This device complies with Industry Canada’s license-exempt RSS regulations. Operation of this device is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation.When operated in the 5.15 to 5.25 GHz frequency range, this device is restricted to indoor use to reduce the potential for harmful interference with co-channel Mobile Satellite Systems.

European Union Regulatory Conformance

The Declaration of Conformity made under Radio Equipment Directive 2014/53/EU is available for viewing at: www.hpe.com/eu/certificates. Select the document that corresponds to your device’s model number as it is indicated on the product label.

Wireless Channel Restrictions

5150-5350MHz band is limited to indoor only in the following countries; Austria (AT), Belgium (BE), Bulgaria (BG), Croatia (HR), Cyprus (CY), Czech Republic (CZ), Denmark (DK), Estonia (EE), Finland (FI), France (FR), Germany (DE), Greece (GR), Hungary (HU), Iceland (IS), Ireland (IE), Italy (IT), Latvia (LV), Liechtenstein (LI), Lithuania (LT), Luxembourg (LU), Malta (MT), Netherlands (NL), Norway (NO), Poland (PL), Portugal (PT), Romania (RO), Slovakia (SK), Slovenia (SL), Spain (ES), Sweden (SE), Switzerland (CH), Turkey (TR), United Kingdom (UK).

  Radio
  Frequency Range MHz
  Max EIRP
  BLE/Zigbee   2402-2480   9 dBm
  Wi-Fi   2412-2472   20 dBm
  5150-5250   23 dBm
  5250-5350   23 dBm
  5470-5725   30 dBm
  5725-5850   14 dBm

Medical

  1. Equipment not suitable for use in the presence of flammable mixtures.
  2. Connect to only IEC 60950-1 or IEC 60601-1 certified products and power sources. The end user is responsible for the resulting medical system complies with the requirements of IEC 60601-1.
  3. Wipe with a dry cloth, no additional maintenance required.
  4. No serviceable parts, the unit must be sent back to the manufacturer for repair.
  5. No modifications are allowed without Aruba approval.

This device is intended for indoor use in professional healthcare facilities.This device has no IEC/EN60601-1-2 essential performance.

Use of this equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation. If such use is necessary, this equipment and the other equipment should be observed to verify that they are operating normally.

Compliance is based on the use of Aruba approved accessories.

Use of accessories, transducers and cables other than those specified or provided by the manufacturer of this equipment could result in increased electromagnetic emissions or decreased electromagnetic immunity of this equipment and result in improper operation.

Contact Aruba

Main Site https:                                              //www.ArubaInstantOn.comSupport Site https:                                          //www.ArubaInstantOn.com/contact-support/Aruba Instant On Community https:              //community.ArubaInstantOn.comNorth America                                               Telephone 1-800-943-45261-408-754-1200International Telephone https:                         //www.ArubaInstantOn.com/contact-support/

Open Source Code

This product includes code licensed under the GNU General Public License, the GNU Lesser General Public License, and/or certain other open source licenses. A complete machine-readable copy of the source code corresponding to such code is available upon request. This offer is valid to anyone in receipt of this informationand shall expire three years following the date of the final distribution of this product version by Hewlett Packard Enterprise Company. To obtain such source code, send a check or money order in the amount of US $10.00 to: Hewlett Packard Enterprise CompanyAttn: General Counsel6280 America Center DriveSan Jose, CA 95002USA

Warranty

This hardware product is protected by an Aruba warranty. For details, visit https://www.ArubaInstantOn.com/docs.

 