BALBOA TP200 Panel User Guide

Table of Contents

TP200 Panel

TP200 PANELUser GuideStandard Menu

42369 Rev A1

Your Single Source Solution

THANK YOUfor using Balboa Water Group spa controls.Please visit us at www.BalboaWaterGroup.com

This user guide applies to TP200, TP240 and TP260 panels.TP200 PANELTP240 PANELTP260 PANELBP CONTROL SYSTEMSoftware Version: 7.0 and later

1

TABLE OF CONTENTS

02 SEQUENCE KEY 03 PANEL INTERFACE & TERMINOLOGY 04 MAIN MENUS & NAVIGATION 05 SET TIME-OF-DAY 06 CHANGE SET TEMPERATURE 07 SET FILTER CYCLE TIMES 09 RESTRICT OPERATIONS 13 INVERT DISPLAY 14 HOLD MODE (STANDBY) 16 LIGHT TIMER PROGRAMMING 17 SPA BEHAVIOR 19 HEAT SETTINGS 23 FILL IT UP!

39 PREFERENCES42 DISPLAY F° OR C° 43 TURN ON/OFF REMINDERS DISPLAY 44 SET 12 OR 24 HOUR CLOCK 45 SET CLEANUP CYCLE DURATION 46 TURN ON/OFF M847 UTILITIES50 INFORMATION SUBMENU 51 GFCI TEST FEATURE 55 FAULT LOG 57 TEMPERATURE SENSOR READINGS

25 PANEL MESSAGES27 GENERAL 29 HEATER RELATED 31 TEMPERATURE SENSOR RELATED 33 MISCELLANEOUS 34 CONTROL SYSTEM RELATED 36 REMINDER

Balboa Water Group | Your Single Source Solution

2SEQUENCE KEYRED LCD CHARACTERS Red indicates flashing or changing characters. For example, these segments flash when you press the TEMP button to change the Set Temperature.BLUE LCD CHARACTERS Blue indicates an alternating message or a progressive message. When you view Time-of-Day, this progressive message appears.TEMPERATURE BUTTON The TEMP button icon indicates an “action.” For example, pressing the TEMP button initiates any one of the following actions: adjusting the Set Temperature, menu navigation, setting the Filter Cycle Time, setting the Heat Mode, etc.LIGHT BUTTON The LIGHT button icon indicates navigation or a selection.HOLLOW DOTS Hollow dots indicate that your last setting was not saved. For example, when you set a feature such as Time-of-Day, you need to press the LIGHT button to save your setting. If you do not press the LIGHT button, the Main Screen will appear automatically after a few moments, and your last setting will not be saved.SOLID DOTS Solid dots indicate that your last setting will be saved. For example, if you change the Set Temperature and pause a few moments, the Main Screen will appear automatically, and your setting will be saved. The same applies to other features that will be discussed later.DASHED LINE AROUND THE DISPLAY Dashed lines indicate a Menu item that depends on a manufacturer configuration and may or may not appear.TP200 USER GUIDE 42369 Rev A2

3

PANEL INTERFACE & TERMINOLOGY

A

B

DC

TEMP

TEMP is an umbrella term that refers to panel buttons that control temperature. For example, TEMP refers to these buttons (B)(E).

E

CDF

TEMP Button(s)In addition to controlling the Set Temperature, use the TEMP buttons to initiate actions while changing various settings.

Main ScreenThe Main Screen (A) displays the water temperature by default. The water temperature does not flash. If you press the TEMP button, the water temperature is replaced by the Set Temperature. The Set Temperature flashes.Set TemperatureThe Set Temperature is programmed by you. If you start at the Main Screen and press the TEMP button, the Set Temperature will appear, and it will be flashing. At this point you can do two things: One, you can change the Set Temperature. Two, you can navigate menus by pressing the LIGHT button. If you do not press any buttons for a few moments, the Main Screen will appear automatically.

LIGHT ButtonIn addition to turning On/Off the spa lights, use the LIGHT button (D) to navigate menus. Also, when you change settings such as Time-of-Day or Filter Cycle duration, make sure you press LIGHT to save your settings. If you don’t press LIGHT, the Main Screen will appear automatically and your setting will not be saved in most cases.JETS ButtonThe JETS button (C) will control a one-speed pump or a two speed pump. It depends on how your spa is configured.AUX ButtonControl an auxiliary device, such as a pump or a blower (F).

Balboa Water Group | Your Single Source Solution

4

MAIN MENUS & NAVIGATION

Follow this sequence to navigate the Main menu. If you are navigating any of the menus and decide you want to go back to the Main Screen, simply pause a few moments. The Main Screen will appear automatically.SEQUENCE KEY ( View page 2 for full description )Flashing characters Progressive message Press TEMP button for “action” Press LIGHT button to “select” Pause / back to Main Screen / setting not saved Pause / back to Main Screen / setting savedMenu Items may or may not appear

SEQUENCEMain Screen Press the TEMP button. The Set Temperature will appear and flash. While the Set Temperature is still flashing, press the LIGHT button. Temperature rangeHeat ModeTime-of-DayFlip Display

Lock Panel & Settings Lock TemperatureHold Function

Filter Cycle 1

Filter Cycle 2

Preferences

Utilities

TP200 USER GUIDE 42369 Rev A2

5

SET TIME-OF-DAY

Be sure to set the Time-of-DaySetting the Time-of-Day can be important for determining water filtration times and other background features.In this example we will change the Time-of-Day from 8:57 PM to 7:30 PM. Follow the same sequence to set the Time-of-Day for your spa.If Time-of-Day has not been set, SET TIME will flash on the display in the TIME menu.You can choose a 12-hour or 24-hour time display (See Page 44). CE control systems default to a 24-hour time display.NOTE:This note refers to systems that do not keep track of Time-of-Day when powered down.If power is interrupted to such systems, Time-of-Day is not stored. The system will still operate and all other user settings will be stored. If filter cycles are required to run at a particular time of day, resetting the clock will return the filter times to the actual programmed periods.When such a system starts up, it defaults to 12:00 Noon, so another way to get filter times back to normal is to start up the spa at noon on any given day. SET TIME will still flash in the TIME Menu until the time is actually set, but since the spa started at noon, the filter cycles will run as programmed.

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until TIME appears.This is the current Time-of-Day setting.Press TEMP, and the hour will flash.Press TEMP to change the hour.Press LIGHT to select the minutes.Press TEMP to change the minutes from 57 to 30.Press LIGHT to save your setting. The Main Screen will appear automatically. If you do not press LIGHT, your setting will not be saved, and the Main Screen will appear momentarily.

Balboa Water Group | Your Single Source Solution

6

CHANGE THE SET TEMPERATURE

Change the Set Temperature

SEQUENCE

When using a panel with WARM and COOL

Main Screen

temperature buttons, pressing either WARM or COOL will cause the Set Temperature to flash. Pressing a temperature button again will adjust

Press the TEMP button. The Set Temperature will appear and flash.

the Set Temperature in the direction indicated on the button. When the LCD stops flashing, the

While the Set Temperature is flashing, press TEMP repeatedly to change the Set Temperature from 102 to 104. Your

spa will heat to the new Set Temperature when

setting will be saved automatically.

required.

The Main Screen will appear

· · ·

If the panel has a single temperature button, pressing TEMP will cause the Set Temperature

momentarily after you stop pressing TEMP. Or, press LIGHT to have the Main Screen appear immediately.

to flash. Pressing TEMP again will cause the

Set Temperature to change in one direction (e.g.

UP). After allowing the display to stop flashing,

pressing the TEMP button will cause the Set

Temperature to flash and the next press will

change the Set Temperature in the opposite

direction (e.g. DOWN).

You can choose an °F or °C temperature display (See Page 42). CE control systems default to °C.

Press-and-HoldIf a Temperature button is pressed and held when the Set Temperature is flashing, the Set Temperature will continue to change until the button is released. If only one Temperature button is available and the limit of the Temperature Range is reached when the button is being held, the progression will reverse direction.

TP200 USER GUIDE 42369 Rev A2

7

SET FILTER CYCLE TIMES

Main FiltrationFilter cycles are set using a start time and a duration. Hours are adjusted in 1-hour increments, and minutes are adjusted in 15-minute increments. The end time is calculated and displayed automatically.Filter Cycle 1In this example, we will do the following:· View the current start time · View the duration · Set the start time to 8:00 PM · Set the duration to 3 hoursThis means Filter Cycle 1 will end at 11:00 PM. Follow the same sequence to set Filter Cycle 1 for your spa.View the next page to set the start time and duration for Filter Cycle 2.SEQUENCE KEY ( View page 2 for full description )Flashing characters Progressive message Press TEMP button for “action” Press LIGHT button to “select” Pause / back to Main Screen / setting not saved Pause / back to Main Screen / setting savedMenu Items may or may not appear

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until F1 appears. F1 is an abbreviation for “Filter Cycle 1”.Press TEMP. The following message means you are about to set the start time of Filter Cycle 1.Press TEMP to view the current start time. In this example, the start time is 7:00 PM.Press TEMP change the hour from 7 to 8.Press LIGHT to select the minutes.Press TEMP to change the minutes from 45 to 00.Press LIGHT to save your setting. The following message means you are about to set the duration. The same sequence is used to set the start time and the duration.This message means Filter Cycle 1 will end at 11:00 PM.Press LIGHT to go back to the Main Screen, or wait a few moments and the Main Screen will appear automatically.

Balboa Water Group | Your Single Source Solution

8

SET FILTER CYCLE TIMES

Filter Cycle 2In this example, we will do the following:· Turn On Filter Cycle 2 · View the current start time · View the duration · Set the start time to 8:00 AM · Set the duration to 3 hoursThis means Filter Cycle 2 will end at 11:00 AM. Follow the same sequence to set Filter Cycle 2 on your spa.Filter Cycle 2 is optional. It is Off by default on most control systems. However, you can turn it On if you like.It is possible to overlap Filter Cycle 1 and Filter Cycle 2, which will shorten overall filtration by the overlap amount.Purge CyclesThe heater pump (view page 18) runs for the whole duration of the filter cycle.In order to maintain sanitary conditions, secondary Pumps and/or a Blower will purge water from their respective plumbing by running briefly at the beginning of each filter cycle.If Filter Cycle 1 is set for 24 hours, enabling Filter Cycle 2 will initiate a purge when Filter Cycle 2 is programmed to begin.On some systems, purge cycles may run several times a day, independent of the filter cycle.

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until F2 appears.Press TEMP. The following message means Filter Cycle 2 is Off.Press TEMP to turn On Filter Cycle 2.Press TEMP. The following message means you are about to set the start time of Filter Cycle 2.Press TEMP to view the current start time.Press TEMP change the hour from 7 to 8.Press LIGHT to select the minutes.Press TEMP to change the minutes from 45 to 00.Press LIGHT. The following message means you are about to set the duration. Use the same sequence to set the start time and duration.This message means Filter Cycle 2 will end at 11:00 AM.Press the LIGHT button, and the Main Screen will appear. Or, pause a moment, and the Main Screen will appear automatically.

TP200 USER GUIDE 42369 Rev A2

9

RESTRICTING OPERATION

The panel can be restricted to prevent unwanted use.Lock PanelLocking the panel prevents the panel from being used, but all automatic functions are still active. Follow this sequence to Lock the panel.

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Temperature is flashing, press LIGHT until LOCK appears.Press the TEMP button.Press the LIGHT button to select Panel Lock (not Temperature Lock).This indicates that you will lock the panel in the following screens.OFF indicates that the panel will be unlocked.Press TEMP to view ON.ON indicates that the panel will be locked.Press LIGHT to save your setting. The Main Screen will appear automatically.If you do not press LIGHT, your setting will not be saved, and the Main Screen will appear momentarily.

10

Unlock Panel

SEQUENCE

Follow this sequence to unlock the panel.

Main Screen

This unlock sequence may be used from any screen that may be displayed on a restricted panel.

Press the TEMP button. LOCK will appear.

NOTE: If the panel has a WARM and a COOL temperature button (view page 3), only the WARM button will work in the Unlock Sequence.

While holding down the TEMP button, press the LIGHT button two times slowly.

UNLK indicates that the Panel and settings are unlocked.

SEQUENCE KEY ( View page 2 for full description )Flashing characters Progressive message Press TEMP button for “action” Press LIGHT button to “select” Pause / back to Main Screen / setting not saved Pause / back to Main Screen / setting savedMenu Items may or may not appear

Press the LIGHT button, and

· · ·

the Main Screen will appear.

Or, pause a moment, and

the Main Screen will appear

automatically.

Balboa Water Group | Your Single Source Solution

TP200 USER GUIDE 42369 Rev A2

11

RESTRICTING OPERATION (CONTINUED)

Lock Temperature & SettingsFollow this sequence to lock the temperature and settings.Locking the Temperature allows Jets and other features to be used, but the Set Temperature and other programmed settings cannot be adjusted.Temperature Lock allows access to a reduced selection of menu items:· View the Set Temperature · FLIP · LOCK · UTIL · INFO · FAULT LOGThe next page illustrates how to Unlock the Temperature and Settings.

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until LOCK appears.Press the TEMP button.

Press the TEMP button.

OFF indicates that the temperature is unlocked.

Press the TEMP button.

ON indicates that the

temperature is locked.

Press LIGHT to save your setting.

°°°

The Main Screen will

appear automatically.

If you do not press LIGHT, your setting will not be saved, and the Main Screen will appear momentarily.

12

Unlock Temperature & Settings

SEQUENCE

Follow this sequence to unlock the temperature and settings.This unlock sequence may be used from any screen that may be displayed on a restricted panel.NOTE: If the panel has a WARM and a COOL temperature button (view page 3), only the WARM button will work in the Unlock Sequence.

Main ScreenPress the TEMP button. The Set Temperature will appear and flash.While holding down the TEMP button, press the LIGHT button two times slowly.UNLK indicates that the Panel and/or Temperature is unlocked.

SEQUENCE KEY ( View page 2 for full description )Flashing characters Progressive message Press TEMP button for “action” Press LIGHT button to “select” Pause / back to Main Screen / setting not saved Pause / back to Main Screen / setting savedMenu Items may or may not appear

Press the LIGHT button, and

· · ·

the Main Screen will appear.

Or, pause a moment, and

the Main Screen will appear

automatically.

Balboa Water Group | Your Single Source Solution

TP200 USER GUIDE 42369 Rev A2

13

INVERT DISPLAY

Follow this sequence to invert the display. This display is inverted (A), and this display is not inverted (B).AB

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until FLIP appears.Press TEMP to flip the display.

Press LIGHT to save your setting.

°°°

The Main Screen will

appear automatically.

If you do not press LIGHT, your setting will not be saved, and the Main Screen will appear momentarily.

Follow the same sequence to restore the default display orientation (B).

14

HOLD MODE

HOLD MODEFollow this sequence activate Hold Mode.Hold Mode is used to disable the pumps during service functions like cleaning or replacing the filter. This mode will last for 1 hour unless it is exited manually by pressing the LIGHT button.SEQUENCE KEY ( View page 2 for full description )Flashing characters Progressive message Press TEMP button for “action” Press LIGHT button to “select” Pause / back to Main Screen / setting not saved Pause / back to Main Screen / setting savedMenu Items may or may not appear

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.Press the LIGHT button until HOLD appears.Press the TEMP button to put the pumps on Hold for one hour.This message indicates that the pumps are on Hold for one hour, and this message will appear during the whole hour.You can exit Hold Mode at any time by pressing the LIGHT button.This indicates that the Hold Mode is done. After a moment the Main Screen will appear automatically.

Balboa Water Group | Your Single Source Solution

TP200 USER GUIDE 42369 Rev A2

15

HOLD MODE + DRAIN MODE

DRAIN MODE

SEQUENCE

Some control systems have Drain Mode, which is a component of Hold Mode. Drain Mode allows a pump to be employed when draining the water.Follow this sequence to use Hold Mode + Drain Mode.

Main Screen Press the TEMP button. The Set Temperature will appear and flash.Press the LIGHT button until HOLD appears.Press the TEMP button to put the pumps on Hold for one hour.

SEQUENCE KEY ( View page 2 for full description )Flashing characters

This message indicates that the pumps are on Hold, and this message will appear during the whole hour.

Progressive message Press TEMP button for “action”

You can exit Hold Mode at any time by pressing the LIGHT or TEMP buttons.

Press LIGHT button to “select”

If your control system has Drain

or

Pause / back to Main Screen / setting not saved

Mode, press the JETS button to

Pause / back to Main Screen / setting saved

activate it.

Menu Items may or may not appear

This message indicates that Drain Mode is running for one hour, and this message will appear during the whole hour.

You can end Drain Mode and return to Hold Mode by pressing the JETS button.

You can exit Hold Mode + Drain

Mode at any time by pressing the

LIGHT or TEMP buttons.

or

This indicates that Hold Mode + Drain Mode is done. After a moment the Main Screen will appear automatically.

Balboa Water Group | Your Single Source Solution

LIGHT TIMER PROGRAMMING

Light Timer OptionIf LITE TIMR does not appear in the Main Menu, the Light Timer feature is not enabled by the manufacturer of your spa.In this example, we will do the following:· Turn On the Light Timer · Set the start time to 8:00 AM · Set the duration to 3 hoursThis means the Light Timer will end at 11:00 AM. Follow the same sequence to set the Light Timer on your spa.When available, the Light Timer is OFF by default.

SEQUENCEMain Screen Press the TEMP button. The Set Temperature will appear and flash. While the Temperature is flashing, press LIGHT until LITE TIMR appears.This means Light Timer is Off.This means Light Timer is On. This means you are about to set the start time of the Light Timer. Press TEMP to view the start time.Press TEMP change the Hour from 7 to 8.Press LIGHT to select the minutes.Press TEMP to change the minutes from 45 to 00.Press LIGHT to save your setting, and RUN HRS will appear. This message means you are about to set the duration. Use the same sequence to set the duration.

16This message means the Light Timer will end at 11:00 AM. Press LIGHT to go back to the Main Screen, or wait a few moments and the Main Screen will appear automatically.TP200 USER GUIDE 42369 Rev A2

17

SPA BEHAVIOR

FILTRATION AND OZONE

CLEAN-UP CYCLE (Optional)

If your spa does not have a circulation pump, pump 1 low and the ozone generator will run during a filter cycle. If your spa has a circulation pump, the ozone will run with the circulation pump.Many control systems are factory-programmed with one filter cycle that will run in the evening (assuming the time-of-day is properly set) when energy rates are often lower. The filter cycle time and duration are programmable (view page 7). A second filter cycle can be enabled as needed.On most systems at the start of each filter cycle, the blower (if there is one) or Pump 2 (if there is one) will run briefly to purge its plumbing to maintain good water quality.On some systems, purge cycles may run several times a day, independent of the filter cycle.FREEZE PROTECTIONIf the temperature sensors within the control system’s heater detect a low enough temperature, then the pump(s) and the blower automatically activate to provide freeze protection. The pump(s) and blower will run either continuously or periodically depending on conditions.In colder climates, an optional additional freeze sensor may be added to protect against freeze conditions that may not be sensed by the standard sensors. Auxiliary freeze sensor protection acts similarly except with the temperature thresholds determined by the switch. See your dealer for details.

When a pump or blower is turned on by pressing a button on the panel, a clean-up cycle begins 30 minutes after the pump or blower is turned off or times out. The pump and the ozone generator will run for 30 minutes or more, depending on the control system. On some control systems, you can change this setting (view page 45).PUMPSPress the JETS button once to turn Pump 1 On or Off, and to shift between low-speed and high-speed if equipped. If left running, Pump 1 will turn off after a time-out period.The heater pump will run when the blower or any other pump is on.If the spa is in Ready Mode (view page 20), Pump 1 low may also activate for at least 1 minute every once in a while to detect the spa temperature (polling) and then to heat to the set temperature if needed. When the low-speed turns on automatically, it cannot be deactivated from the panel, however the high speed may be started.3 CIRCULATION PUMP MODESIf the spa is equipped with a circulation pump, it will be configured to work in one of the following three modes:MODE 1: The circulation pump will operate continuously (24 hours) with the exception of turning off for 30 minutes at a time when the water temperature reaches 3°F (1.5°C) above the set temperature (most likely to happen in very hot climates).MODE 2: The circulation pump will stay on continuously, regardless of the water temperature.

Balboa Water Group | Your Single Source Solution

MODE 3: A programmable circulation pump will come on when the control system is checking the water temperature (polling), during filter cycles, during freeze conditions, or when another pump is on. Circulation pump modes are determined by the Manufacturer and cannot be changed in the field.HOW DOES YOUR CONTROL SYSTEM CHECK THE WATER TEMPERATURE? The control system (A) activates a pump that circulates water from the spa through the water heater (B) shown below. The water heater contains two temperature sensors (C). When water flows around the sensors, the control system calculates the water temperature. This process is referred to as “polling” in this user guide.HEATER PUMP The heater pump is any pump dedicated to circulating water through the water heater. If your spa has a circulation pump, the circulation pump will serve as the heater pump. If your spa does not have a circulation pump, a two-speed pump will serve as the heater pump. If the heater pump is a two-speed pump, anytime it is activated automatically (for any reason, including to check the water temperature), it will activate at low speed.ABC

18TP200 USER GUIDE 42369 Rev A2

19HEAT SETTINGSKeep your spa heated and ready to enjoy, or keep it cool and save energy. Heat Settings help you do both.Heat Settings are divided into two groups. 1 – Heat Modes 2 – Temperature RangesBalboa Water Group | Your Single Source Solution

HEAT MODESThere are three Heat Modes1 – READY MODE Ready Mode usually keeps the water temperature close to the Set Temperature 24 hours a day. If you use your spa consistently, you probably want to use Ready Mode.2 – REST MODE Rest Mode only heats the water during filter cycles. If you do not use your spa for an extended period of time, you may want to use Rest Mode.3 – READY-IN-REST MODE This mode is a subfeature of Rest Mode. When your spa is in Rest Mode, and you press the JETS button, Rest Mode will automatically switch to ReadyIn-Rest Mode for one hour. During this hour the control system will attempt to keep the water temperature close to the Set Temperature.

20TEMP RANGESHIGH RANGE80° – 104° F26.6° – 40.0 CLOW RANGE50° – 99° F10.0° – 37.2 CDifferent High and Low Temperature Ranges may be determined by the Manufacturer. Freeze Protection is active in High and Low ranges.TP200 USER GUIDE 42369 Rev A2

21HEAT SETTINGSHEAT MODES

Follow this sequence to view the current Heat Mode and/ or change the Heat Mode. There are two Heat Modes you can select from the panel menu:1 – Ready Mode (RDY) 2 – Rest Mode (REST)Ready-In-Rest Mode (RRST) is a third Heat Mode. But, it is a subfeature of Rest Mode and is not selectable from the panel menu. However, when you follow the sequence to view the current Heat Mode, any of the three Heat Modes can be displayed as the current Heat Mode.

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until one of the following Heat Modes appears: RDY, REST, RRST. The first one to appear is the current Heat Mode setting.In this example RDY appears first, which means the current Heat Mode is set to READY. If you wait for a moment, the Main Screen will appear automatically, and the Heat Mode setting will remain READY.If you want to change the Heat Mode to REST, press the TEMP button.REST indicates that the Heat Mode will be set to REST. Press LIGHT to save your setting. The Main Screen will appear automatically. If you do not press LIGHT, your setting will not be saved, and the Main Screen will appear momentarily.NOTESREST MODE When the spa is in REST Mode (REST), the Main Screen will alternate between displaying the water temperature and REST.READY-IN-REST MODE If you press the JETS button while in Rest Mode, the spa will switch to Ready-In-Rest Mode (RRST) for one hour. The Main Screen will alternate between displaying the water temperature and RRST.

Balboa Water Group | Your Single Source Solution

22HEAT SETTINGSTEMPERATURE RANGES

Follow this sequence to view the current Temperature Range and/or change the Temperature Range. There are two ranges to choose from:1 – High Range (TR:HI) 2 – Low Range (TR:LO)

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until one of the following settings appears: TR:HI or TR:LO. The first one to appear is the current Temperature Range setting.

In this example TR:HI appears first. TR:HI indicates that the current Temperature Range setting is HIGH. If you wait for a moment, the Main Screen will appear automatically, and the Temperature Range setting will remain HIGH.

If you want to change the Temperature Range to LOW,

°°°

press the TEMP button.

This indicates that your Temperature Range will be set to LOW.

Press LIGHT to save your setting. The Main Screen will appear automatically. If you do not press LIGHT, your setting will not be saved, and the Main Screen will appear momentarily.

SEQUENCE KEY ( View page 2 for full description )Flashing characters Progressive message Press TEMP button for “action” Press LIGHT button to “select” Pause / back to Main Screen / setting not saved Pause / back to Main Screen / setting savedMenu Items may or may not appear

TP200 USER GUIDE 42369 Rev A2

23

FILL IT UP!

PREPARATION AND FILLINGFill the spa to its correct operating level. Be sure to open all valves and jets in the plumbing system before filling to allow as much air as possible to escape from the plumbing during the filling process. Air may be trapped in the plumbing after filling the spa. Remove trapped air by priming the pumps. Priming will be discussed shortly.After powering On the spa at the main power panel, the spa panel display (view right) will go through a specific sequence. This sequence is normal and will display a variety of information regarding the configuration of the control system. After the sequence ends, the control system will start Priming Mode.PRIMING MODEPriming Mode will last for 4-5 minutes, or you can manually exit Priming Mode after the pump(s) have primed.Regardless of whether Priming Mode ends automatically or you manually exit Priming Mode, the control system automatically returns to normal heating and filtering at the end of Priming Mode. During Priming Mode, the heater is disabled to allow the priming process to be completed without the possibility of energizing the heater under low-water-flow or no-water-flow conditions. Nothing comes on automatically, but the pump(s) can be energized manually with the panel buttons.PRIMING THE PUMPSThis panel message (view right) indicates that the spa is in Priming Mode. Priming Mode lasts 4-5 minutes. Note: Turning the power Off and back On again will initiate a new pump priming session. If you need more than 4-5 minutes to prime all of the pumps, cycle power to the spa.What is priming? Priming removes trapped air from the plumbing. How do you know when a pump is done priming? Priming is complete when water flows from the jets without air bubbles. So, watch the jets as you prime the pump. If your spa has more than one pump, prime each pump one at a time. Why prime one at a time? If multiple pumps are running, it is too difficult to determine which pump is circulating air bubbles, or the flow from one pump may hide the flow from another pump.

Spa Panel DisplayPriming Mode Panel Message

Balboa Water Group | Your Single Source Solution

24Follow these steps to prime a two-speed pump: Press the button for that pump once to turn it On at low speed. Press the button again to run the pump at high speed. Run the pump at high speed for 2 minutes. If priming is not complete after 2 minutes, turn off the pump and repeat the process. Follow these steps to prime any one-speed pump, including a circulation pump: Press the button for that pump once to turn it On. Run the pump for 2 minutes. If priming is not complete after 2 minutes, turn off the pump and repeat the process. Sometimes momentarily turning the pump Off and On will help it to prime. Do not do this more than 5 times. If the pump will not prime, shut off the power to the spa and call for service. Which pump is the heater pump? When the spa has just entered Priming Mode, press the LIGHT button and see if any water flows. If so, you have a circulation pump serving as the heater pump. If not, a two-speed pump serves as the heater pump. A circulation pump is controlled with the LIGHT button (in Priming Mode only). A two-speed heater pump is controlled by pressing the JETS button.The heater pump is the most important pump to prime.Once the heater pump is primed, prime any additional pumps. The AUX button may control one of these pumps. IMPORTANT: A pump should not be allowed to run without priming for more than 2 minutes. Under NO circumstances should a pump be allowed to run without priming beyond the end of the 4-5 minute Priming Mode. Doing so may cause damage to the pump and in some cases may cause the system to energize the heater and go into an overheat condition.EXITING PRIMING MODEPriming Mode ends automatically after for 4-5 minutes. However, you can manually exit Priming Mode during this time by pressing the TEMP button. When Priming Mode ends (automatically or manually) the panel will display dashes. Once the control system cycles water through the heater for one minute, the dashes will be replaced by the water temperature.TP200 USER GUIDE 42369 Rev A2

25

PANEL MESSAGES

Helpful information to help keep your spa running smoothlyThis chapter lists all of the Panel Messages and explains each one. Some Panel Messages have corresponding Message Codes. If so, the Message Code (B) appears next to the Panel Message (A).MESSAGE CODESThe easiest way to explain a Message Codes is with a troubleshooting scenario. For example, what happens if the spa water overheats? The panel will display this message (A). The control system will capture the following information and save it in a fault log:· Time-Of-Day. · Water temperature, Set Temperature. · The number of days that have passed since the water overheated. · Temperature Range. · Heat Mode. · Message Code (B).The Message Code links the Panel Message to the corresponding Fault Log information. For example, this Message Code (B) will appear in the corresponding Fault Log. See how to review the Fault Log on page 55.

A Panel Message

B Message Code

Balboa Water Group | Your Single Source Solution

26TP200 USER GUIDE 42369 Rev A2

27PANEL MESSAGESGENERAL

Message Code *

This message indicates that the spa is in Priming Mode.Each time the spa is powered up, it will enter Priming Mode. The purpose of Priming Mode is to allow the user to run each pump and manually verify that the pumps are primed (air is purged) and water is flowing. This typically requires observing the output of each pump separately, and is generally not possible in

normal operation. Priming Mode lasts 4 minutes, but you can exit it earlier by pressing any Temp button. The heater is not allowed to run during Priming Mode.NOTE: If your spa has a circulation pump, you can turn it On by pressing the LIGHT button during Priming Mode. The circulation pump will run by itself when Priming Mode is exited.

ORThe water temperature is unknown or out of date.

After the pump has been running for 1 minute, the temperature will be displayed.This display may also appear if the pump has not run for more than one hour while the spa is in Ready Mode.

The water is too cold – freeze protection.A potential freeze condition has been detected, or the Aux Freeze Switch has closed, so all pumps and blowers are activated. All pumps and blowers are ON for at least 4 minutes after the potential freeze condition has ended, or when the auxiliary freeze switch opens.

In some cases, pumps may turn On and Off and the heater may operate during Freeze Protection.This is an operational message, not an error indication.

* View page 55 for instructions on how to review the Fault Log that corresponds with the Message Code. * * This message can be reset from the panel with any button press.Balboa Water Group | Your Single Source Solution

28

Message Code *The spa water is too hot. One of the water temperature sensors has detected a spa water temperature of 110°F (43.3°C), so spa functions are disabled. The Control System will automatically reset when the spa water temperature is below 108°F (42.2°C). Extended pump operation or high ambient air temperatures can cause overheating.Message Code *J29 Warning. J29 is a connector in the control system. J29 is typically used as a heater disable input. As such, it should not typically be shorted at power-up. This message appears if J29 is shorted at power-up. If this message appears after several power-ups, contact your dealer or service organization.

Water Flow Check List· Make sure the spa is filled with enough water to allow proper water flow through all of the spa’s plumbing.· Closed valves can inhibit proper water flow. · Jets may be equipped with water valves. If too many watervalves are closed, proper water flow may be inhibited. · Make sure suction covers are unobstructed and free of debris. · One pump cycles water through the heater. All plumbingconnected to this pump and the heater must be free from trapped air. Trapped air can restrict proper water flow. Remove trapped air by priming this pump.

TP200 USER GUIDE 42369 Rev A2

29PANEL MESSAGESHEATER RELATEDControl SystemHeaterMessage Code *Low water flow through the heater. ** There may not be enough water flow through the heater to carry the heat away from the heating element. Heater start up will begin again after about 1 min. See “Water Flow Check List” on page 28.Message Code *Inadequate water flow through the heater. ** There is not enough water flow through the heater to carry the heat away from the heating element, so the heater has been disabled. See “Water Flow Check List” on page 28. After the problem has been resolved, you must press any button on the panel to reset the control system and begin heater start up.* View page 55 for instructions on how to review the Fault Log that corresponds with the Message Code. * * This message can be reset from the panel with any button press.Balboa Water Group | Your Single Source Solution

30

The heater may be dry. ** Possible dry heater, or not enough water in the heater to start it. The spa is shut down for 15 minutes. Press any button to reset the heater start-up. See “Water Flow Check List” on page 28.Message Code *Heater is dry. ** There is not enough water in the heater to start it. The spa is shut down. After the problem has been resolved, you must press any button to reset and restart heater start up. See “Water Flow Check List” on page 28.Message Code *The heater is too hot. ** One of the water temp sensors has detected 118°F (47.8°C) in the heater and the spa is shut down. You must press any button to reset when water is below 108°F (42.2°C). See “Water Flow Check List” on page 28.

Message Code *

* View page 55 for instructions on how to review the Fault Log that corresponds with the Message Code. * * This message can be reset from the panel with any button press.TP200 USER GUIDE 42369 Rev A2

31PANEL MESSAGESTEMPERATURE SENSOR RELATEDControl System

Temperature SensorA

Temperature SensorB

Heater

The temperature sensor balance is poor. The temperature sensors may be out of sync.

Message Code *

* View page 55 for instructions on how to review the Fault Log that corresponds with the Message Code. * * This message can be reset from the panel with any button press.Balboa Water Group | Your Single Source Solution

32

The temperature sensor balance is poor. ** The temperature sensors are out of sync. If this message appears in the panel display, this fault has been established for at least 1 hour. Contact your dealer or service organization.Temperature sensor “A” has failed. Either temperature sensor “A” or the sensor circuit has failed. Contact your dealer or service organization.Temperature sensor “B” has failed. Either temperature sensor “B” or the sensor circuit has failed. Contact your dealer or service organization.

Message Code * Message Code * Message Code *

* View page 55 for instructions on how to review the Fault Log that corresponds with the Message Code. * * This message can be reset from the panel with any button press.TP200 USER GUIDE 42369 Rev A2

33PANEL MESSAGESMISCELLANEOUS

No Communications.The panel is not receiving communication from the control system. Contact your dealer or service organization.

Control System

No Communications

Panel Cable

Panel

°F or °C is replaced by °T.The Control System is in Test Mode. Contact your dealer or service organization.

Balboa Water Group | Your Single Source Solution

34PANEL MESSAGESCONTROL SYSTEM RELATEDMessage Code *Memory Failure – Checksum Error. ** At Power-Up, the system has failed the Program Checksum Test. This indicates a problem with the firmware (operation program). Contact your dealer or service organization.Message Code *Memory Warning – Persistent Memory Reset. ** Appears after any system setup change. Contact your dealer or service organization if this message appears on more than one power-up, or if it appears after the system has been running normally for a period of time.Message Code *Clock Error. ** The clock that keeps track of time when the spa is powered Off has failed. Contact your dealer or service organization.Note: Not Applicable on some control systems.Configuration Error ­ Spa will not Start Up. Contact your dealer or service organization.* View page 55 for instructions on how to review the Fault Log that corresponds with the Message Code. * * This message can be reset from the panel with any button press.TP200 USER GUIDE 42369 Rev A2

35Message Code *GFCI Failure – System Could Not Test/Trip the GFCI. NORTH AMERICA ONLY. May indicate an unsafe installation. Contact your dealer or service organization.Message Code *A Pump Appears to be Stuck ON. Water may be overheated. POWER DOWN THE SPA. DO NOT ENTER THE WATER. Contact your dealer or service organization.A Pump Appears to have been Stuck ON when spa was last powered. POWER DOWN THE SPA. DO NOT ENTER THE WATER. Contact your dealer or service organization.The water level is too low. Some systems have a water level detector, and this message appears if it detects that the water level is too low. Pumps are shut down until this problem clears.

Message Code *

* View page 55 for instructions on how to review the Fault Log that corresponds with the Message Code. * * This message can be reset from the panel with any button press.Balboa Water Group | Your Single Source Solution

36

PANEL MESSAGESREMINDER

General maintenance helps your spa.Reminder messages alternate with the Main Screen.Reminder Messages can be chosen individually by the Manufacturer. They may be disabled entirely, or there may be a limited number of Reminders on a specific model.

The frequency of each Reminder (i.e. 7 days) can be specified by the Manufacturer.Press a Temperature button to reset a displayed Reminder Message.The display of Reminder Messages can be turned On/Off (view page 43).

Main Screen

Check pHThis message may appear every 7 days. Check the pH of your spa’s water with a pH test kit, and adjust pH with the appropriate chemicals.

Check the sanitizer chemicalsThis message may appear every 7 days. Check sanitizer level and other water chemistry with a test kit and adjust with the appropriate chemicals.

Clean the water filter.This message may appear every 30 days. Clean the filter media as instructed by the manufacturer. See Hold Mode on page 14.

TP200 USER GUIDE 42369 Rev A2

37

Test the GFCI or RCD.This message may appear every 30 days. The Ground Fault Circuit Interrupter (GFCI) or Residual Current Device (RCD) is an important safety device and must be tested on a regular basis to verify its reliability.Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation.A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function.

Warning:If freezing conditions exist, a GFCI or RCD should be reset immediately or spa damage could result. If the GFCI or RCD does not reset and freezing conditions exist, drain the spa of all water until the spa is functional again.The end user should always trained to test and reset the GFCI or RCD on a regular basis.

Change the spa water.This message may appear every 90 days. Change the water in the spa on regular basis to maintain proper chemical balance and sanitary conditions.

Clean the spa cover.This message may appear every 180 days. Vinyl covers should be cleaned and conditioned for maximum life.

Treat the wood.This message may appear every 180 days. Wood skirting and furniture should be cleaned and conditioned per the manufacturers instructions for maximum life.

Change the water filter.This message may appear every 360 days. Filters should be replaced occasionally to maintain proper spa function and sanitary conditions.

Balboa Water Group | Your Single Source Solution

38

Change the mineral cartridge as needed.Install a new mineral cartridge per you spa manufacturer’s instructions.

Check the ozone and/or UV generator.This message may appear every 360 days. Check your ozone and/or UV generator per your spa manufacturer’s instructions.

Your spa needs a service check.This message may appear every 365 days. Contact your service organization for a service check.

TP200 USER GUIDE 42369 Rev A2

39

40

PREFERENCESFine-tune your spa’s settings

Balboa Water Group | Your Single Source Solution

TP200 USER GUIDE 42369 Rev A2

41PREFERENCESPREFERENCES MENU

This is the Preferences menu structure.

Main Screen Press the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until PREF appears. Press LIGHT to view UTIL, which is the next screen on the Main menu.

Change the temperature display between Fahrenheit and Celsius.°°°

Switch the clock between 12 hour and 24 hour displays.°°°

Turn On/Off reminders.°°°

Set the cleanup cycle duration.

°°°

Turn On/Off M8.

°°°

This is the address number of the Dolphin

wireless remote. The number ranges from 0 – 7.

Press TEMP to view the current address number for the Dolphin II or Dolphin III. In this example the address number is 0. If you wait a moment, the Main Screen will appear automatically, and the address number will remain 0.Press TEMP again to change the address number (0-7).

Press LIGHT to save your setting, and the PREF Screen will appear automatically. If you pause a moment, the Main Screen will appear automatically. Or Press LIGHT to navigate the menu.

Balboa Water Group | Your Single Source Solution

42PREFERENCESDISPLAY °F OR °C

Follow this sequence to set your panel to display Fahrenheit or Celsius.Most North American control systems default to °F. CE control systems default to °C.

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until PREF appears.

SEQUENCE KEY ( View page 2 for full description )Flashing characters Progressive message Press TEMP button for “action” Press LIGHT button to “select” Pause / back to Main Screen / setting not saved Pause / back to Main Screen / setting savedMenu Items may or may not appear

This indicates that you are about to set your display to Fahrenheit or Celsius.Press TEMP to toggle your selection between Fahrenheit and Celsius.Once you have chosen Fahrenheit or Celsius, Press LIGHT to set your selection. The PREF window will appear in a moment.Press LIGHT to view UTIL. Or, pause a moment and the Main Screen will appear.

TP200 USER GUIDE 42369 Rev A2

43PREFERENCESTURN ON/OFF REMINDERS DISPLAY

The Reminders Display feature has two settings: YES, NO. YES means the feature is On and Reminders will be displayed. NO means the feature is Off and Reminders will not be displayed.Note: Reminders continue to run in the background even when not displayed. So, turning the display of Reminders On/Off does not reset any Reminder counts.Follow this sequence to view the current setting and to turn this feature On or Off.

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until PREF appears.Press TEMP until F/C appears.Press LIGHT until the following message appears.This indicates that you are about view the current setting for Reminders. Reminders has two settings: YES or NO.

Press TEMP to view the current setting. In this example YES appears first, so YES is the current setting. YES indicates that Reminders is On. If you pause for a moment, the Main Screen will appear automatically and the Reminders setting will remain YES.If you want to change the setting to NO, press TEMP. NO indicates that the Reminders setting will be turned Off.Press the LIGHT button to save your setting.Press LIGHT to view UTIL. Or, pause a moment and the Main Screen will appear.

Balboa Water Group | Your Single Source Solution

44PREFERENCESSET 12 OR 24 HOUR CLOCK

The Clock feature has two settings: 12 hours or 24 hours. Follow this sequence to view the current Clock setting and to change the setting.

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until PREF appears.

SEQUENCE KEY ( View page 2 for full description )Flashing characters Progressive message Press TEMP button for “action” Press LIGHT button to “select” Pause / back to Main Screen / setting not saved Pause / back to Main Screen / setting savedMenu Items may or may not appear

Press the TEMP button until F/C appears.Press the LIGHT button until 24-12 appears. 24-12 indicates that you are about view the current Clock setting. Press TEMP to view the current Clock setting. Clock has two settings: 24HR or 12HR. The setting that appears first is the current setting.In this example, 24HR appears first, so it is the current setting. If you pause for a moment, the Main Screen will appear automatically. The Clock setting will remain at 24 Hours. If you want to change the Clock setting to 12 Hours, press the TEMP button. This indicates that the Clock will be set to 12 hours. Press the LIGHT to save your setting.Press LIGHT to view UTIL. Or, pause a moment and the Main Screen will appear.

TP200 USER GUIDE 42369 Rev A2

45PREFERENCESSET CLEANUP CYCLE DURATION

Follow this sequence to view the current Cleanup Cycle duration or change the duration.The duration can be set from 0 – 4 hours in 30 minute increments.The heater pump will run during a Cleanup Cycle. View page 18 for more information on the heater pump.Cleanup Cycle is not available on all control systems.

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until PREF appears.Press TEMP until F/C appears.Press LIGHT until the following message appears.This indicates that you are about to view the current duration setting.Press TEMP to view the current duration.In this example the current duration is 2.5 hours. If you press LIGHT, the Main Screen will appear automatically, and the duration will remain 2.5 hours. If you want to change the duration, press the TEMP button. In this example the duration will be changed to 3.0 hours. Press LIGHT to save your setting, and PREF will appear. Press LIGHT to view UTIL. Or, pause a moment and the Main Screen will appear.

Balboa Water Group | Your Single Source Solution

46PREFERENCESTURN ON/OFF M8

Follow this sequence to view the current M8 setting and to change the setting.M8 is artificial intelligence software contained in your spa’s control system. M8 looks for opportunities to decrease device usage by evaluating water temperature readings. Stable water temperatures equal less device usage and less wear and tear.M8 is not available on all control systems.

SEQUENCEMain Screen Press the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until PREF appears.Press TEMP until F/C appears.Press LIGHT until M8 appears.

SEQUENCE KEY ( View page 2 for full description )Flashing characters Progressive message Press TEMP button for “action” Press LIGHT button to “select” Pause / back to Main Screen / setting not saved Pause / back to Main Screen / setting savedMenu Items may or may not appear

Press TEMP to view the current setting.In this example the current setting is OFF. If you pause a moment, the Main Screen will appear automatically, and the setting will remain OFF.Press TEMP to switch the setting from OFF to ON.Press LIGHT to save your setting, and PREF will appear.Press LIGHT to view UTIL. Or, pause a moment and the Main Screen will appear.

TP200 USER GUIDE 42369 Rev A2

47UTILITIESHelpful tools and information for spa techniciansBalboa Water Group | Your Single Source Solution

48TP200 USER GUIDE 42369 Rev A2

49UTILITIESUTILITIES MENU

This is the Utilities menu.Main Screen Press the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until UTIL appears. Utilities menu. Press the TEMP button to view INFO.

Pressing the TEMP button to view the GFCI Test Menu (view page 51).

Display temperature readings from Sensor A and Sensor B (view page 57).

°°°

Pressing the TEMP button to view the fault log (view page 55).

°°°

°°°

Balboa Water Group | Your Single Source Solution

50UTILITIESINFORMATION SUBMENU

This is the INFO submenu on the Utilities menu.

Main Screen Press the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until UTIL appears.Press the TEMP button to view INFO. Information submenu.Software ID of the control system.Model number of the control system.

These messages will display once and return to the beginning. Press the TEMP button to display the message again.If you wait 10 seconds, the Main Screen will appear automatically.

Configuration setup number. Configuration signature.

120V or 240V input

voltage sensed by a UL

OR

control system at startup.

3-6 or 1-3 heater wattage as programmed on a CE control system.

Heater type.

DIP switch 1 setting 0: test mode On 1: test mode OffDIP switch 2+3+4 settings = the number of HS pumps with heat

SW stands for DIP Switch Settings. 16 indicates that it is showing 6 DIP switches that are numbered 1 – 6.

0: store settings, 1: memory reset N/A or special amperage rule 1 or 2

This is the panel software version.

TP200 USER GUIDE 42369 Rev A2

51UTILITIESGFCI TEST FEATURE

The GFCI test feature is not available on CE rated control systems.A GFCI is an important safety device and is required equipment on a hot tub installation.Your spa may be equipped with a GFCI Protection feature. (UL rated systems only.) If your spa has this feature enabled by the manufacturer, the GFCI Trip Test must occur to allow proper spa function.Within 1 to 7 days after startup, the spa may trip the GFCI to test it. (The number of days is factory programmed.) The GFCI must be reset once it has tripped. After passing the GFCI Trip Test, any subsequent GFCI trips will indicate a ground fault or other unsafe condition and the power to the spa must be shut off until a service person can correct the problem.

Forcing the GFCI Trip TestThe installer or spa owner can cause the GFCI Trip Test to occur at any time by following the sequence on the next page.The GFCI should trip within a few seconds and the spa power should shut down. If the GFCI does not trip (see next page), shut down the power to the spa.The installer or service technician should:· Manually verify that a GFCI breaker is installed and that the circuit and spa are wired correctly.· Verify the function of the GFCI with its own test button.· Restore power to the spa and repeat the GFCI Trip Test.Once the GFCI is tripped by the test, reset the GFCI and the spa will operate normally from that point. You can verify a successful test by following the sequence on page 54. PASS should appear after a temp button is pressed from the GFCI screen.The end user should always be trained to test and reset the GFCI on a regular basis.

Not all control systems trip the GFCI automatically after a certain number of days. If the control system does not trip the GFCI automatically, the GFCI must be tripped manually.

WARNING:If freezing conditions exist, a GFCI should be reset immediately or spa damage could result. If the GFCI does not reset and freezing conditions exist, drain the spa of all water until the spa is functional again.

Balboa Water Group | Your Single Source Solution

52

Follow this sequence to perform a GFCI test.If the test is successful, the spa will power Off.If the test is unsuccessful, the spa needs to be powered Off, and a spa technician needs to fix the electrical problem.

SEQUENCE – TEST THE GFCIMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until UTIL appears.

SEQUENCE KEY ( View page 2 for full description )Flashing characters Progressive message Press TEMP button for “action” Press LIGHT button to “select” Pause / back to Main Screen / setting not saved Pause / back to Main Screen / setting savedMenu Items may or may not appear

This indicates that you are entering GFCI Test Mode. (This feature is not available on CE rated systems.) This screen will display either ARMD or PASS.Press TEMP and TRIP will begin flashing.Press TEMP to perform the test.

UNSUCCESSFUL TESTThis indicates that the test has failed. When this message appears, the spa will be inoperable, and the spa should be powered Off. A spa technician needs to fix the electrical problem.

SUCCESSFUL TESTThe spa will power Off if the GFCI test is successful. Power On the spa at the GFCI.

TP200 USER GUIDE 42369 Rev A2

53UTILITIESGFCI TEST FEATURE (CONTINUED)

Follow this sequence to reset the GFCI test feature and bring it back to its armed state within the control system.You may want to reset the GFCI test feature if the spa is about to be moved to a new location, so that it will need to be re-tested after installation at the new location.

SEQUENCE – RESET GFCI TESTMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until UTIL appears.

SEQUENCE KEY ( View page 2 for full description )Flashing characters Progressive message Press TEMP button for “action” Press LIGHT button to “select” Pause / back to Main Screen / setting not saved Pause / back to Main Screen / setting savedMenu Items may or may not appear

This indicates that you are entering GFCI Test Mode. (This feature is not available on CE rated systems.)PASS appears if the GFCI test was successful. If PASS is not shown, you cannot reset the GFCI test to ARMD, since it is already ARMD.

This indicates that the GFCI is armed.

Press LIGHT to navigate back to TRIP.

Or, pause a moment, and the Main

· · ·

Screen will appear automatically.

Balboa Water Group | Your Single Source Solution

54

Follow this sequence to check the current status of the GFCI test feature.The current status is either PASS or ARMD.If the last screen of this sequence displays PASS, the most recent GFCI test was performed and passed successfully.If the last screen of this sequence displays ARMD, either no GFCI test has been performed yet, or the most recent GFCI test was unsuccessful.

SEQUENCE – GFCI TEST STATUSMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until UTIL appears.

This indicates that you are entering GFCI Test Mode. (This feature is not available on CE rated systems.)

This screen will display either ARMD or PASS.

Pause for a moment, and the Main Screen will appear automatically.

°°°

TP200 USER GUIDE 42369 Rev A2

55

UTILITIESFAULT LOG

A Little History can help a lot.

Useful information about your spa is captured when a fault occurs. The information is stored in a Fault Log. Up to 24 faults can be stored in the Fault Log. The diagram below shows the information that is captured in one fault. This information can help spa technicians

diagnose and fix issues. The sequence on the next page shows how to view the fault log.Not every entry in the Fault Log is an actual “fault”. For example, message code MO19 is inserted into the fault log to identify each time the spa restarts.

INFORMATION CONTAINED INONE FAULT

Fault “Fault” Number“Message Code Code” NumberNumber “Day” of Days

Each time a fault occurs, it is assigned a unique number, starting with number 1. The next fault is assigned number 2, and so on. Up to 24 faults can be stored in memory. In this example the fault number is 24. The fault with the highest fault number is the most recent fault.Each fault is assigned a message code. The code corresponds with a panel message. In this example the message code is MO16. All panel messages and message codes are listed and explained in the chapter titled “Panel Messages”.This screen indicates the number of days that have passed since the fault occurred. In this example, 5 days have passed. Each time power to the spa is cycled Off and On again, a new day is added.

Time when fault occurred

Set Temperature Temperature Range

Heat Mode

In this example the Set Temperature is 102°F. The Temperature Range setting is High, and the Heat Mode setting is Ready. View page 20 for information on Heat Modes. View page 20 for information on Temperature Ranges.

Water

Sensor

Temperature Name

This is the temperature reading from sensor A.

Water

Sensor

Temperature Name

This is the temperature reading from sensor B.

View page 57 for more information about temperature sensor readings.

Balboa Water Group | Your Single Source Solution

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.While the Set Temperature is flashing, press LIGHT until UTIL appears.Press TEMP until INFO appears.Press LIGHT until FAULT LOG appears.This indicates that you are entering the Fault Log list.This is Fault number 24. Press TEMP to view the information for Fault 24. Or, press LIGHT to view fault 23.This is the Message Code. View the chapter titled “Panel Messages” for an explanation of the message codes.This is the number of days that have passed since the fault occurred.The fault occurred at this time.

This was the Set Temperature. This was the Temperature Range. This was the Heat Mode.

This was the water temperature reading from sensor A.

This was the water temperature reading from sensor B.

Press LIGHT to navigate back

°°°

to the fault number. Or, pause a

moment and the Main Screen will

appear automatically.

56Press LIGHT to view the next fault stored in memory. Fault 23 is next in this example.

°°°

°°°

TP200 USER GUIDE 42369 Rev A2

57UTILITIESTEMPERATURE SENSOR READINGS

The control system calculates water temperature by using readings from two sensors located inside the heater (view below). One sensor is named A; the other, B.Going from left to right, the sensor order may be A and B, or B and A. The order depends on how the sensors are connected to the control system.Spa technicians can view separate readings directly from sensor A and sensor B for diagnostic purposes.Control System

Temperature SensorA

Temperature SensorB

HeaterBalboa Water Group | Your Single Source Solution

58

Follow this sequence to view separate temperature readings from sensor A and sensor B on the Main screen.

SEQUENCEMain ScreenPress the TEMP button. The Set Temperature will appear and flash.Press the LIGHT button until UTIL appears.

SEQUENCE KEY ( View page 2 for full description )Flashing characters Progressive message Press TEMP button for “action” Press LIGHT button to “select” Pause / back to Main Screen / setting not saved Pause / back to Main Screen / setting savedMenu Items may or may not appear

This indicates that this feature is Off currently. If you press the LIGHT button, the Main Screen will appear and the panel will function normally.This indicates that this feature can be turned On. If you press the LIGHT button, the Main Screen will appear, and this feature will be On. Temperature readings from sensor A and sensor B appear on the Main Screen.The Main Screen displays temperature readings from sensor A and sensor B, until you turn Off this feature. Follow the same sequence to turn Off this feature.

TP200 USER GUIDE 42369 Rev A2

59

WARNING! Qualified Technician Required for Service and Installation.

Basic Installation and Configuration Guidelines· Use minimum 6AWG copper conductors only. · Torque field connections between 21 and 23 in lbs. · Readily accessible disconnecting means to be provided attime of installation. · Permanently connected. · Connect only to a circuit protected by a Class A Ground FaultCircuit Interrupter (GFCI) or Residual Current Device (RCD) mounted at least 5′ (1.52M) from the inside walls of the spa/hot tub and in line of sight from the equipment compartment. · CSA enclosure: Type 2 · Refer to Wiring Diagram inside the cover of the control enclosure. · Refer to Installation and Safety Instructions provided by the spa manufacturer.Warning: People with infectious diseases should not use a spa or hot tub.Warning: To avoid injury, exercise care when entering or exiting the spa or hot tub.Warning: Do not use a spa or hot tub immediately following strenuous exercise.Warning: Prolonged immersion in a spa or hot tub may be injurious to your health.Warning: Maintain water chemistry in accordance with the Manufacturers instructions.Warning: The equipment and controls shall be located not less than 1.5 meters horizontally from the spa or hot tub.Warning! GFCI or RCD Protection.The Owner should test and reset the GFCI or RCD on a regular basis to verify its function.Warning! Shock Hazard! No User Serviceable Parts.Do not attempt service of this control system. Contact your dealer or service organization for assistance. Follow all owner’s manual power connection instructions. Installation must be performed by a licensed electrician and all grounding connections must be properly installed.

CSA Compliance/ConformitéCaution:· Test the ground fault circuit interrupter or residual current device before each use of the spa.· Read the instruction manual. · Adequate drainage must be provided if the equipment is to beinstalled in a pit. · For use only within an enclosure rated CSA Enclosure 3. · Connect only to a circuit protected by a Class A ground faultcircuit interrupter or residual current device. · To ensure continued protection against shock hazard, use onlyidentical replacement parts when servicing. · Install a suitably rated suction guard to match the maximum flowrate marked.Warning:· Water temperature in excess of 38°C may be injurious to your health.· Disconnect the electrical power before servicing.Attention:· Toujours verifier l’efficacite du disjoncteur differentiel avant d’utiliser differentiel avant d’utiliser le bain.· Lire la notice technique. · Lorsque l’appareillage est installe dans une fosse, on doit assurerun drainage adequat. · Employer uniquement a l’interieur d’une cloture CSA Enclosure 3. · Connecter uniquement a un circuit protege par un disjoncteurdifferentiel de Class A. · Afin d’assurer une protection permanente contre le danger deshock electrique, lors de l’entretien employer seulement des pieces de rechange identiques. · Les prises d’aspiration doivent etre equipees de grilles convenant au debit maximal indique.Avertissement:· Des temperatures de l’eau superieures a 38°C peuvent presenter un danger pour la sante.· Deconnecter du circuit d’alimentation electrique avante l’entretien.Warning/Advertissement:· Disconnect the electric power before servicing. Keep access door closed.· Deconnecter du circuit d’alimentation electrique avant l’entretien. Garder la porte fermer.

Balboa Water Group | Your Single Source Solution

INFORMATIONTP200 SUPPORTTrademark | Patent NoticesBALBOA WATER GROUP and the stylized logo are registered trademarks or applications applied for in the US Patent & Trademark Office. All rights reserved. All other product or service names are the property of their respective owners. Products are covered under one of more of the following US Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6282370, 6590188, 7030343, 7, 417, 834 B2 & Canadian Pt 2342614 plus others. Other patents both foreign and domestic applied for and pending.INTELLECTUAL PROPERTY ADVISEMENTAll Intellectual property, as defined below, owned by or which is otherwise the property of Balboa Water Group or its respective suppliers relating to the Balboa Water Group BP Spa Control Systems, including but not limited to, accessories, parts, or software relating to the “System”, is proprietary to Balboa Water Group and protected under federal laws, state laws, and international treaty provisions. Intellectual Property includes, but is not limited to, inventions (patentable or unpatentable), patents, trade secrets, copyrights, software, computer programs, and related documentation, and other works of authorship. You may not infringe or otherwise violate the rights secured by the Intellectual Property. Moreover, you agree that you will not (and will not attempt to) modify, prepare derivative works of, reverse engineer, decompile, disassemble, or otherwise attempt to create source code from the software. No title to or ownership in the Intellectual Property is transferred to you. All applicable rights of the Intellectual Property shall remain with Balboa Water Group and its suppliers.42369_rev A TP200 User Guide ©2020 Balboa Water Group. Single Source Solution. All rights reserved. 3030 Airway Avenue | Costa Mesa, CA 92626 | p 714.384.0384 | www.balboawatergroup.com Specifications subject to change without notice.

60TP200 USER GUIDE 42369 Rev A2

61

TP200 PANEL Email

PhoneP : + 714.384.0384 Customer Service is available: M – F 7:00AM to 6:00PM PT

Corporate OfficeBalboa Water Group 3030 Airway Avenue Costa Mesa, CA 92626

MEXICO OPERATIONS Balboa Water Group Aguila Azteca 6011 Baja Maq. El Aquila Mexico 22221

EUROPEAN OPERATIONS Balboa Water Group Hydroair International ApS Roustvej 50 DK-6800 Varde

Balboa Water Group | Your Single Source Solution