The shell of the product is ABS. The transparent window is a crystal with high hardness acrylic, hardness value is equivalent to toughened glass.
Working Voltage and the Mode of Connection
Working Voltage: DC24V/36V/48V/52V/60/72V(Display choose by itself) And we also can set the voltage.
Function:
Show contentThe content of speed, power, hitch, total mileage, single mileage.
The function of control and settingController the switching power. Wheel diameter setting. Idle automatic sleep time setting.Backlight setting. Startup mode setting. Drive mode setting. Voltage level setting.ControllerCurrent Limit Setting. USB charging function.
Communicating Protocol: UARTAll content on display (Power on within 1 second)
3.1 Voltage level
3.2 Multifunctional display area
Total mileage ODO. Single mileage TRIP. Digital voltage display VOL. Fault code ERR
Fault Code (Decimal System)
Fault Status
Remarks
0
Normal State
E02
Brake
E03
Power Sensor Failure (Riding Sign) Implemented
Not Implemented Here
E04
61an / h Cruise
E05
Real-Time Cruise
E06
Bantry Under Voltage
E07
Motor Failure
£08
Handle Failure
E09
Controller Failure
E010
CommunicationReception Failure
E011
Communication Failure
E012
BMS Communication Failure
£013
Headlight Failure
3.3 Speed display areaUnit: MPH, KM/HThe speed signal is taken from the Hall signal inside the motor. Sent to the controller by the controller(Time of single Hall period,unit:1MS). The display calculates the true speed based on wheel diameter and signal data calculates the true speed.(The motor Holzer also needs to set the number of magnetic steel)3.4 Vehicle power gear adjustment , 0-9 0-9 digital display.3.5 Vehicle status display area:Zero start and non-zero start prompt:The headlight turns on the prompt: Constant speed cruise hint: Communication fault prompt: USB charging hint
4. SettingP01: Backlight brightness:The 1 level is the darkest, Level 3 brightest; Default:3P02: Mileage: unit, 0: KM; 1: MILE; Default: KMP03: Voltage level: 24V, 36V, 48V, 52V, 60V. Default:52VP04: Dormancy time: 0 means no dormancy; Other numbers are dormant time.The range is 1-60 minute. Default: 5P05: ReserveP06: Wheel diameter: The unit is inch. The accuracy is 0.1; Default:10.0P07: Speed measuring magnetic steel number.The range is 0-255. Default:28P08: Rate-limiting: The range is 0-100km/h.Default: 100P09: Zero start, no zero start setting; 0 means zero start.1means no Zero start.Default: 0P10: ReserveP11: EABS switch choose.The range is 1-5.0 means closing.1 means weakest. 2 Means strongestP12: Soft and hard start strength.The range is 1-5. The softest is 1.The hardest is5.Default: 3P13: ReserveP14: ReserveP15: Controller under-voltageP16: ODO Zero setting: keep pressing + for 5 seconds,ODO will zero clearing.P17: When it shows 0,it can not use cruise.When it shows 1,it can use cruise.Default:0P18: ReserveP19: ReserveP20: Communication protocol defaults 4. It can not change.
Introduction of buttons and interfaces
When it is shut down, long-time pressing to turn on the power.When it is powered on, it can change the interface between the ODO, TRIP, VOL, by pressing for a short time.
When it is powered on, long-time pressing to turn off, short-time pressing can change gear.
Long-time pressing and can get into the menu to change the interface.
Get into the setting interface, short-time pressing can change parameters. Short-time pressing or long-time pressing can add or reduce the numerical value. After changing,short-time pressingto change the next numerical value. After changing, long-time pressing, and getting out of the interface, or waiting 8 seconds, it can save the numerical value and drop out by itself.
Crankshaft regulating motor speed by Up and down.Motor speed increase; Relax hand return to zero.