beamZ Pro Mini Fresnel User Manual

MADE EAZY151.382 V1.0BTF50Z MINI FresnelUSER MANUAL

SAFETY INSTRUCTION

WARNING! Before carrying out any operations with the unit, carefully read this instruction manual and keep it with care for future reference. It contains important information about the installation, usage, and maintenance of the unit.

  •  Unpack and check carefully that there is no transportation damage before using the unit
  • Please read these instructions carefully and follow the instructions.
  • Observe all safety warnings. Never remove safety warnings or other information from the equipment.
  • Be sure that no ventilation slots are blocked; otherwise, the unit will overheat.

CAUTION: Before connecting the equipment to the power outlet, first verify that the mains voltage and frequency match the values specified on the equipment. If the equipment has a voltage selection switch, connect the equipment to the power outlet only if the equipment values and the mains power values match. If the included power cord or the power adapter does not fit in your wall outlet, contact your electrician.

  • After connecting the unit, check all cables in order to prevent damage or accidents, e.g., due to tripping hazards.
  • Make sure that the power cord is never crimped or damaged. Check the device and the power cord from time to time.
  • Always disconnect power from the mains, when the device is not used or before cleaning! Only handle the power cord by the plug. Never pull out the plug by tugging the power cord.
  • Unplug the power cord and power adapter from the power outlet if there is a risk of a lightning strike or before extended periods of disuse.
  • Do not switch the unit on and off in short intervals.
  •  Do not connect the unit to a dimmer pack.
  •  Install the unit in a well-ventilated place.
  • Never place any material over the lens.
  • Always allow free air space of at least 50 cm around the unit for ventilation.
  • Make sure that the area below the installation place is blocked when rigging, deriving or servicing the fixture.
  • For mounting height >100 cm, always fix the fixture with an appropriate safety rope. Fix the safety-rope at the correct fixation points only.The safety-rope must never be fixed at the transport handles!
  • Never look directly at the light beam. Please note that fast changes in lighting, e. g. flashing light may trigger epileptic seizures in photosensitive persons or persons with epilepsy.
  • This unit is not designed for permanent operation. Consistent operation breaks will ensure that the device will serve you for a long time without defects.

CAUTION: If the power cord of the device is equipped with earthing contact, then it must be connected to an outlet with a protective ground.Never deactivate the protective ground of a power cord.

  • Make sure that the unit is not exposed to extreme heat, moisture, or dust.
  • Clean the unit using a dry cloth.
  •  Do not touch the fixture bare-handed during its operation (housing becomes very hot). Allow the fixture to cool for at least 5 minutes before handling.
  • This unit is designed exclusively for indoor use, do not use this equipment in the immediate vicinity of fluid (does not apply to special outdoor equipment – in this case, observe the special instructions noted below). Do not expose this unit to flammable materials, fluids or gases.
  • If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has reached room temperature.
  • Never attempt to bypass the thermostatic switch or fuses.
  •  Do not dismantle or modify the unit.
  •  For replacement use fuses/bulbs of the same type and rating only.
  •  Repairs, servicing, and electric connections must be carried out by a qualified technician.
  • The ambient temperature must always be between -5° C and +45° C.
  • If this unit is operated in any other way, than the one described in this manual, the product may suffer damages and the warranty becomes void.
  •  Plastic bags must be kept out of reach of children.
  • The unit must be installed out of the reach of children. Never leave the unit running unattended.

This symbol on the product or on its packaging indicates that this product shall not be treated as household waste. Instead, it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment.

By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. The recycling of materials will help to conserve natural resources. For more detailed information about recycling of this product, please contact your local Civic Office, your household waste disposal service, or the shop where you purchased the product.

UNPACKING INSTRUCTION

CAUTION! Immediately upon receiving the product, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain the packing material for inspection if any parts appear damaged from shipping or the package itself shows signs of mishandling.  Save the package and all packing materials. In the event that the product must be returned to the factory, it is important that the product be returned to the original factory box and packing.If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.

POWERSUPPLY

On the label on the backside of the product is indicated on this type of power supply must be connected. Check that the mains voltage corresponds to this, all other voltages than specified, the light effect can be irreparably damaged. The product must also be directly connected to the mains and may be used. No dimmer or adjustable power supply. Always connect the device to a protected circuit (circuit breaker or fuse). Make sure the device has an appropriate electrical ground to avoid the risk of electrocution or fire.

RIGGING

The fixture may be set up on a stable and even surface. By means of the fixing facilities of the baseplate, the unit can also be mounted upside down to a truss, see the below picture.  For fixing, certified clamps with correct save working load are required. According to the figure, the quick-lock bolts of the omega brackets are placed into the openings provided in the base plate and turned clockwise until they lock (to the stop). The mounting place must be of sufficient stability and be able to support a weight of 10 times of the unit’s weight. Secure the fixture with a safety cable so that it cannot fall down.When carrying out any installation, always comply with European and national guidelines concerning rigging, truss, and all other safety issues. Always let theinstallation checked out by an authorized dealer!

DMX512 CONTROL

If you are using a standard DMX controller, you can connect the DMX output of the controller directly to the DMX input of the first fixture in a DMX chain.Always connect the output of one unit with the input of the next fixture until all fixtures are connected.

Caution: At the last fixture, you must close the DMX line with a terminating resistor. Take an XLR connector and solder a 120 Ohm resistor between signal (-) and signal (+) and connect it to the DMX output of the last fixture in the line.

CLEANING

The buildup of dust, dirt and other airborne particles will reduce the fixture’s light output. It will also prevent the fixture from cooling correctly, and this will reduce the fixture’s lifetime. The rate of dirt buildup will vary depending on environmental factors such as airborne dust, use of smoke machines, airflow from ventilation systems, etc.  The fixture’s cooling fans will accelerate buildup, and any smoke particles that are present in the atmosphere will increase the tendency for dirt to clog.To get the best performance and lifetime from the fixture, inspect it regularly and clean it as soon as you see signs of dirt buildup.Assess the operating environment each time you begin to use the fixture. In dusty or smoky conditions, inspect the fixture after a few hours and check it frequently the fixture may attract dirt faster than you expect. Draw up a cleaning schedule that will make sure that dirt is removed before it can build up.Use the following guidelines:

  • Disconnect the fixture from power and allow it to cool completely before cleaning.
  • Do not use solvents, abrasives, or any other aggressive product to clean the fixture.
  •  Vacuum or use low-pressure compressed air to remove dust and loose particles from surfaces and air vents. Prevent the blades of cooling fans from turning before you aim a vacuum or air jet at the fan, or you may spin the fan too fast and damage it.
  •  Clean glass components by wiping gently with a soft, clean, lint-free cloth moistened with a weak detergent solution. Put the solution on the cloth and not on the surface to be cleaned. Avoid rubbing glass surfaces.
  • Dry the fixture with a soft, clean, lint-free cloth or low-pressure compressed air before reapplying power.

REPLACING THE FUSE

If the fuse is defective, replace the fuse with a fuse of the same type and value. Before replacing the fuse, unplug the mains lead.Procedure:Step 1: Open the fuse holder on the rear panel with a fitting screwdriver.Step 2: Remove the old fuse from the fuse holder.Step 3: Install the new fuse in the fuse holder.Step 4: Replace the fuse holder in the housing.

TROUBLESHOOTING

The checklist below may help you troubleshoot in the unlikely event that a problem occurs while using the product :

Symptom Possible cause Suggested action
No response from the fixture. No power to fixture. Check that power is turned on.Check cables and connections.
Fuse has blown or internal fault. Replace mean fuse or contact Beamz support or Beamz authorized service partner. Do not remove base or yoke covers. Do not attempt to replace a fuse or carry out any repairs or services that are not described in this User Manual unless you have both authorizations from Beamz support or Beamz authorized service partner.
Fixture resets correctly but does not respond(or does not respond correctly) to thecontroller. The controller is not connected.Bad DMX-line. Connect controller.Inspect connections and cables. Correct poor connections. Repair or replace damaged cables.
DMX-line has no end resistance. Insert DMX terminator plugin DMX output socket of the last fixture on DMX-line.
Incorrect fixture addressing.A fixture is defective and is disturbing datatransmission on the DMX-line. Check fixture address and DMX mode settings.Unplug DMX IN and OUT connectors and connect them directly together to bypass one fixture at a time until normal operation is regained. Have defective fixtures serviced by an authorized technician?
Pin 2 and 3 are reversed in the XLR connection. Inspect connections and cables. Install a phase-reversing cable between the fixtures or swap pin 2  and 3 in the fixture, that behaves erratically.
Error after fixture reset. The effect requires mechanical adjustment. Check fixture’s software version and error messages for more information. Contact Beamz support or Beamz authorized service partner.
Light output cuts out intermittently. The fixture too hot. Allow mixture to cool. Reduce ambient temperature. Ensure free airflow around the fixture. Clean fixture if necessary.
LEDs damaged Disconnect fixture and contact Beamz support or Beamz authorized service partner.
The power supply settings do not match local  AC voltage and frequency. Disconnect fixture. Check settings and correct if necessary.

CONTROL MENU

Menu

Description

DMX  Addr d001-d512 DMX address setting
CHnL 2CH Channel mode
3CH
4CH
5CH
Strb S.01-s.20 Stobe with speed increasing
uL– u.000 ~ u.255 Warm white dimmer
CL– C.000 – C.255 Cold white dimmer
UOL 000 ~ 255 Rotary control of dimmer
Node nod.0 Dimmer speed
nod.1
nod.2
nod.3
nod.4
TEnP -25 ~ 100 Fixture temperature
UEm   Firmware version
Rset Yes Reset
No
pnnF 1.2~24.0 PWM refresh rate adjustment (KHz)

DMX CHANNELS

1 Channel
Channel Function Value Description
1 Dimmer 000-255 Intensity 0-100%
2 Channel
Channel Function Value Description
1 Dimmer 000-255 Intensity 0-100%
2 Strobe 000-255 Strobe, slow to fast
3 Channel
1 Dimmer 000-255 Intensity 0-100%
2 Warm white 000-255 Intensity 0-100%
3 Cold white 000-255 Intensity 0-100%
5 Channel
1 Dimmer 000-255 Intensity 0-100%
2 Color temperature 000-010 No function
011-255 2700K~6500K Colour temperature
3 Warm white 000-255 Intensity 0-100%
4 Cold white 000-255 Intensity 0-100%
5 Strobe 000-255 Strobe, slow to fast

TECHNICAL SPECIFICATIONS

Rated voltage : 100-240VAC, 50-60Hz, 0.7-0.3ALED: 50Watt 2-in-1 (Cool white and warm white)Colour temperature: 2700K – 6500KBeam angle: 25°-90°Illuminance: 7.230lxFlash rate: 1-19HzDMX channels : 1, 2, 3 and 5 via 3-pin XLRDimensions per unit : 230 x 156 x 279mmWeight (per unit) : 2.2 kg

Design and product specifications are subject to change without prior notice.The products referred to in this manual conform to the European Community Directives to which they are subject:• Low Voltage (LVD) 2014/35/EU• Electromagnetic Compatibility (EMC) 2014/30/EU• Restriction of Hazardous Substances (RoHS) 2011/65/EU

offers a wide range of high-performance lighting equipment and related accessories for the rental, entertainment, and architectural lighting markets. BeamZ Pro stands for performance, innovation, and value pricing!

BEAMZLIGHTING.COM

[xyz-ips snippet=”download-snippet”]


Posted

in

by