BLUNT BIRD DN -998 Infrared Thermometer User Manual

Introducing – Infrared Thermometer Check temperature maintaining safe distancing with the contactless thermometer.

MODEL: DN -998

BeSafeMedikit+91 9811609355https://www.besafemedikit.com

Non- ContactInfrared Thermometer

Product Life: 2 Year

Note: To ensure the correct use of this infrared thermometer, please read this manual carefully.

Product Description

This product is a non-contact medical infrared forehead thermometer for the professional measurement of human body temperature.

Fundamental

Anything above absolute zero radiates a certain amount of infrared ray energy, the infrared energy value radiated by different kinds of objects is different, but the infrared energy and wavelength can be used to judge the surface temperature value of the object. According to this principle, the temperature of the forehead can be accurately measured due to its constant temperature. And since the infrared intensity radiated from the forehead at the same temperature is different from that of other objects, such as water, there are at least two temperature models (body temperature and body temperature).

Product Features

  • Ergonomic design, simple & generous appearance.
  • Non-contact high precision, clean & sanitary measurement.
  • Excellent adaptability to environmental, change & can be used in complex environments.
  • One-click temperature switching, convenient & practical.
  • Double 32 groups of memory storage, one-click query, simple & practical.
  • Adjustment of temperature deviation to facilitate different user habits.
  • Automatic shutdown function, no automatic shutdown operation within 20 seconds.
  • Measuring method: Non-contact type
  • Effective Distance: 3cm – 15cm
  • Measuring Range: Human Model 32.0C – 42.9C (85.9F – 109.F)
  • Display: Trichrome backlight
  • Temperature unit: Celsius / Fahrenheit
  • Auto power off: Within 20 seconds.

Advice For The 1st Use

In order to obtain stable and reliable measurement data, when the temperature changes greatly, the infrared measuring instrument of the human body should be placed indoors for15-20 minutes before use.According to the skin color, thickness, and human body parts, the measured temperature will be different, which is normal. The more exposed the human body part is, the greater the impact of environmental temperature is Do not expose the product to the sun or touch the water One-minute interval after two consecutive measurements.

The normal temperature range at different measuring positions

Measuring temperature

NormMtempemtum°C

MnomMtemperaWWF

Anus 36.638 97.8-100.4
oral cavity 35.5-37.5 95.9-99.5
Armpit 34.7-37.3 94.4-99.1
Ear 35.838 96.4100.4

People’s body temperature changes at different times of the day, but is also affected by another external environment, such as age, character,skin color and thickness, etc.

The normal temperature range at different ages

Age Normal temperature*C At normal temperature
0-2yemsold 36.4-38.0 97.5     100.4
340yeamold 36.137.8 97.0100.0
11-65yearsold 35.937.6 96.6      99.7
>65yearsold 36.8-37.5 96.499.5

Technical Parameters

Measurement Methods

Non-Contact

Effective Distance 3cm— 5cm
Measurement Range Human Body Model 32.0″C —42. 91C (85.9°F —109.2°F
Object Mode Or .–   t100

(32’F-212°F)

Measurement Precision Body Temperature ±0. 2*C10. 4°F
Object Temperature ± 3.0°C/37.4°F
Resolution 0.1°C/°F
Operating Conditions 10t —40°C (50°F —104°F ) Rh‘.80% Non condensing
Storage Condition -25r-55t (-13°F-131°F) RH-90°A Non-condensing
Power AAA Dry Battery
Power Consumption Off ModeClOuW
Working Mode-.530mW
Low Power Instructions VoltageS.2.5V
Memory Double 32 Groups(Body Temperature, Object Temperature)
Display Three Colors Backlighting
Temperature Unit Celsius, Fahrenheit
Auto Power Shut Off 20 Seconds
Dimension 138x95x45mm
Net Weight 86g
Meet Standard EN60601-1, EN 12470-5 , ASTM 1965-98

Product Illustration

1. Display 1. Setting key
2. Handheld position 2. Temperature unit
3. Infrared sensor 3. Measuring button
4. Choice mode 4. Battery Installation

LCD Indicator

Function definition

Icon

Detailed description

Battery level indication Light The battery needs to be replaced due to insufficient power
Twinkle Low power, the battery needs to be replaced
Disappear Enough electricity, everything is normal
Measurement mode Temperature body temperature model
Object temperature Material temperature model
Temperature unit °C Centigrade
°F Fahrenheit degree
Temperatur value Measured temperature value
OPEN

Button Functionality

No.

Name of Button

Description

1 Temperature Unit Switch between Celsius and Fahrenheit
2 Memory Button View recently saved measurement data
3 Body Tmemperartautruerte/Object temperature Temperature/temperature switch

Instructions

Temperature modePress the measurement key to start the machine, and the machine will self-check. Normally, all symbols will be displayed. Figure 1O-1) at this time, the machine will automatically measure the ambient temperature and display the ambient temperature (10-2). Make sure that the machine can be tested once in the temperature mode At this time, the measurement is completed and the results are displayed as shown In Figure 10.4). At this time, you can read the data according to the displayed results to determine whether the temperature is abnormal lithe machine is not operated within 15 seconds after measurement, it will automatically shut down

Note:

  1. Keep the head of the sensor clean and do not cover the front with anything
  2. In order to ensure the accuracy of measurement, it is recommended that when you enter a new environment where the temperature changes greatly, wait for ten minutes before measuring
  3. When the temperature of a very high or very low object is measured, wait for ten minutes before measuring the temperature

Sweat and stains on the forehead will affect the accuracy of measurement. Do not measure the body temperature within 30 minutes after eating, bathing, and exercise

Battery Replacement

When the battery symbol is displayed on the screen, please replace the battery, otherwise, the measurement result will be affected. Open the battery cover, take out the exhausted battery, put 2 AA dry batteries, please pay attention to the battery polarity, do not put reversely.

AS Notes:

  1. Please take out the battery when not used for a long time;
  2. Please do not throw exhausted batteries into the fire;
  3. Dispose of used batteries in accordance with local laws and regulations.

Usage Tips

  • Please read this instruction carefully before use;
  • The ambient temperature of this product is 10°C-40°C, and the best temperature is 25°C;
  • Please do not use this product in an environment higher than 40°C or lower than 0°C;
  • Please keep the product away from electrified objects to avoid electric shock; -Please do not use the product in an environment where the relative temperature is greater than 80%;
  • Please do not put this product too close to the electromagnetic range (such as radio, mobile phone, etc.);
  • Please do not expose the product to the sun or near the stove, and do not touch the water; -Please do not shoot down or drop this product. If it is damaged, please do not use it;
  • Hair on the forehead, sweat, a hat, or scarf can affect the accuracy of the measurements; -Please make sure the measuring distance is not greater than 15cm;
  • In order to obtain accurate, stable and reliable measurement data, when the room temperature changes greatly, the thermometer should be placed in the room for ten minutes after use;
  • When the forehead is sweating or other reason causes forehead temperature to be unable to reflect body temperature normally, can measure from earlobe hind; -When cleaning, please wipe the surface of the device with alcohol. In the event of a problem with the product, contact the distributor and do not attempt to repair it yoursiglim:Please keep this product out of the reach of children.

Q&A

Description

Solution

LCD display “LO” or HI” 1. Wind, water vapor, sweat, Cosmetic may affect measurement results2. Set the temperature deviation value3. Large changes in ambient temperature4. The measurement distance is too far
The measurement key is not responding 1. Reinstall the battery

2. Whether the machine is under measurement

No display or error 1. Reinstall the battery
No sound 1. Make sure the sound switch is On
Shut down after measurement 1. Check if the battery level is sufficient

Sign Description

report this ad

Rated voltage 3.0V

Contact Us

Whether you’re interested in bulk purchase, or in manufacturing your own private label, you’re in the right place.For Bulk/OEM/Retail Enquiries, Contact Us: BeSafeMedikitWhatsapp: +91 9811609355,Email: [email protected]Website: https://www.besafemedikit.com

[xyz-ips snippet=”download-snippet”]


Posted

in

by