BRAUN IRT 6030 ThermoScan Infrared Ear Thermometer User Guide

ThermoScanInfrared ear thermometerIRT 6030

This product is manufactured under license to the ‘Braun’ trademark.‘Braun’ is a registered trademark of Braun GmbH, Kronberg, Germany.

© 2017 All rights reserved.

0297

Patentswww.kaz.com/patents/braunDesigned in Germany, Made in Mexico.P/N: A000595R017 SEP 2017

Braun ThermoScan Infrared Ear ThermometerIndications for useThe Braun ThermoScan Infrared Ear Thermometer is indicated for the intermittent measurement and monitoring of human body temperature by consumers in a home use environment.

Product description

  1. IRT 6030
  2. Lens Filter (Box of 20; Model: LF20)
  3. Probe tip
  4. Probe (Inserted with 1pc of lens filter)
  5. ExacTemp light
  6. Lens filter ejector
  7. Display
  8. Power button
  9. Start button
  10. Battery door
  11. Protective case

Proper technique is critical to obtaining accurate temperatures from this thermometer. Therefore, read the instructions carefully and thoroughly.The Braun ThermoScan Infrared Ear Thermometer is intended for household use only and is not intended as a substitute for consultation with your physician.

WARNINGS AND PRECAUTIONS

  •  Please consult your doctor if you see symptoms such as unexplained irritability, vomiting, diarrhea, dehydration, changes in appetite or activity, seizure, muscle pain, shivering, stiff neck, pain when urinating, etc. in spite of any color of the background light or absence of fever.

The operating ambient temperature range for this thermometer is 10 – 40 °C (50 – 104 °F). Do not expose the thermometer to temperature extremes (below –25 °C / –13 °F or over 55 °C / 131 °F) or excessive humidity (> 95 % RH). This thermometer must only be used with genuine Braun ThermoScan lens filters (Model LF40).To avoid inaccurate measurements always use this thermometer with a new, clean lens filter attached.If the thermometer is accidentally used without a lens filter attached, clean the lens (see «Care and cleaning» section). Keep lens filters out of reach of children.This thermometer is intended for household use only. This product is not intended to diagnose any disease but is a useful screening tool for temperature. Use of this thermometer is not intended as a substitute for consultation with your physician.Do not allow children to take their temperatures unattended.Do not modify this equipment without the authorization of the manufacturer.Parents/guardians should call the pediatrician upon noticing any unusual sign(s) or symptom(s).For example, a child who exhibits irritability, vomiting, diarrhea, dehydration, seizure, changes in appetite or activity, even in the absence of fever, or who exhibits a low temperature, may still need to receive medical attention.Children who are on antibiotics, analgesics, or antipyretics should not be assessed solely on temperature readings to determine the severity of their illness.Please seek professional advice immediately when there is a temperature elevation and if you are taking the temperature on:

  •  Neonates and infants under 3 months (consult your physician immediately if the temperature exceeds 37.4 °C or 99.4 °F)
  •  Patients over 60 years of age
  •  Patients having diabetes mellitus or a weakened immune system (e.g. HIV positive, cancer chemotherapy, chronic steroid treatment, splenectomy)
  • Patients who are bedridden (e.g. nursing home patient, stroke, chronic illness, recovering from surgery)
  •  A transplant patient (e.g. liver, heart, lung, kidney) Fever may be blunted or even absent in elderly patients.This thermometer contains small parts that can be swallowed or produce a choking hazard to children. Always keep the thermometer out of children’s reach.

How does Braun ThermoScan Infrared Ear Thermometer work?

Braun ThermoScan Infrared Ear Thermometer measures the infrared heat generated by the eardrum and surrounding tissues. To help avoid inaccurate temperature measurements, the probe tip is warmed to a temperature close to that of the human body. When the thermometer is placed in the ear, it continuously monitors the infrared energy. The measurement is finished and the result is displayed when the thermometer detects that a temperature measurement has been taken.

How to use

  1. Remove the thermometer from the protective case.
  2. Push the Power button During an internal self-check, the display shows all segments. Then the last temperature taken will be displayed for 5 seconds.
  3. The lens filter indicator will blink to signal one is needed.To achieve accurate measurements, make sure a new, clean lens filter is in place before each measurement.Attach a new lens filter by pushing the thermometer probe straight into the lens filter inside the box and then pulling out.Note: The thermometer will not work unless a lens filter is attached.1. Guyton A C, Textbook of medical physiology, W.B. Saunders, Philadelphia, 1996, p 9192. Guyton A C, Textbook of medical physiology, W.B. Saunders, Philadelphia, 1996, p 754-53. Netter H F, Atlas of Human Anatomy, Novartis Medical Education, East Hanover, NJ, 1997, pp 63, 95.
  4. Fit the probe snuggly into the ear canal, then push and release the Start button .
  5. ExacTemp light will pulse while the temperature is in progress. The light will remain solid for 3 seconds to indicate that a successful temperature reading has been achieved.NOTE: If the probe has been properly inserted into the ear canal during the measurement, a long beep will sound to signal the completed measurement.If the probe has NOT been constantly placed in a stable position in the ear canal, a sequence of short beeps will sound, the ExacTemp light will go out and the display will show an error message (POS = position error).See the «Errors and troubleshooting» section for more information.
  6. The confirmation beep indicates that an accurate temperature measurement has been taken. The result is shown on the display.Temperature displays.
  7. For the next measurement, press the Eject button to remove and discard the used lens filter, and put on a new, clean lens filter.The Braun ThermoScan Infrared Ear Thermometer turns off automatically after 60 seconds of inactivityThe thermometer can also be turned off by pressing the Power button .The display will briefly flash OFF and it will go blank.

Temperature taking hints

Always replace disposable lens filters to maintain accuracy and hygiene. The right ear measurement may differ from the measurement taken in the left ear. Therefore, always take the temperature in the same ear. The ear must be free from obstructions or excess earwax uild-up to take an accurate reading.

External factors may influence ear temperatures, including when an individual has:

Factor  Yes affects 
Poor probe placement
Used lens filter
Dirty lens

In the cases below, wait 20 minutes prior to taking a temperature.

Factor Yes affects
Extreme hot and cold room temperature
Hearing aid
Lying on pillow

Memory mode

The last temperature taken is stored in its memory and will be automatically displayed for 5 seconds when it is turned on again.

Night light feature

The thermometer includes a convenient night light to illuminate the display in a dim environment.The light will turn on when you press any button. It will stay on until the thermometer is inactive for up to 15 seconds even after the temperature is taken.

Changing the temperature scale

This thermometer is shipped with the Celsius (° C) temperature scale activated. If you wish to switch to Fahrenheit (° F) and/or back from Fahrenheit to Celsius, proceed as follows:

  1. Make sure the thermometer is turned off.
  2. Press and hold down the Power button . After about 3 seconds the display will show this sequence: ° C / SET / ° F / SET …
  3. Release the Power button when the desired temperature scale is shown.There will be a short beep to confirm the new setting, then the thermometer is turned off automatically.

Care and cleaning

The probe tip is the most delicate part of the thermometer.It must be clean and intact to ensure accurate readings.If the thermometer is ever accidentally used without a lens filter, clean the probe tip as follows:Very gently wipe the surface with a cotton swab or soft cloth moistened with alcohol. After the alcohol has completely dried out, you can put a new lens filter on and take a temperature measurement.If the probe tip is damaged, please contact the local service center.Use a soft, dry cloth to clean the thermometer display and exterior. Do not use abrasive cleaners. Never submerge this thermometer in water or any other liquid. Store thermometer and lens filters in a dry location free from dust and contamination and away from direct sunlight.

Replacing the batteries

The thermometer is supplied with two 1.5 V type AA (LR 06) batteries.

  1. Insert new batteries when the battery symbol appears on the display.
  2. Open the battery compartment. Remove the batteries and replace them with new batteries, making sure the poles are in the right direction.
  3. Snap battery door into place.

Only discard empty batteries. To protect the environment, dispose of empty batteries at your retail store or at appropriate collection sites according to national or local regulations.

The thermometer is initially calibrated at the time of manufacture. If this thermometer is used according to the use instructions, periodic re-adjustment is not required. If at any time you question the accuracy of the temperature measurement, please contact your authorized service center.The manufacturing date is given by the LOT number located in the battery compartment.The first three (3) digits after LOT represent the Julian date that the product was manufactured and the next two (2) digits represent the last two numbers of the calendar year the product was manufactured. The last identifiers are the letters that represent the manufacturer.An example: LOT 11614K, this product has been manufactured on the 116th day of the year 2014.

Errors and troubleshooting

Error Message Situation Solution
No lens filter is attached. Attach a new, clean lens filter.
The thermometer probe was notpositioned securely in the ear.An accurate measurement was not possible.POS = position error Take care that the positioning of thethe probe is correct and remains stable.Replace lens filter and reposition.Press the Start button to begin a newmeasurement.
Ambient temperature is not withinthe allowed operating range(10  –  40 °C or 50  –  104 °F). Allow the thermometer to remain for30 minutes in a room wherethe temperature is between 10and 40 °C or 50 and 104 °F.
Temperature taken is not withintypical human temperature range(34   –  42.2 °C or 93.2  –  108 °F).HI = too highLO = too low Make sure the probe tip and lens areclean and a new, clean lens filter isattached. Make sure the thermometer is properly inserted. Then, take a newtemperature.
System error – self-check display flashes continuously and will not be followed bythe ready beep and the ready symbol.If the error persists,If the error still persists, Wait 1 minute until the thermometerturns off automatically, then turnon again.… reset the thermometer by re-movingthe batteries and putting them back in.… please contact the service center.
The battery is low, but the thermometer will still operate correctly. Insert new batteries.
The battery is too low to take correcttemperature measurement. Insert new batteries.

Model and product specifications

Product specifications

Product ThermoScan IRT 6030
Temperature measurement within seconds
Temperature range °C 34-42.2
Temperature range °F 93.2-108.0
ExacTemp technology
Feedback system
Ready beep
Small, soft tip
Flexible tip
Memory storage capacity 1
Auto-off after 60 sec.
Easy-to-read LCD display
Lens filter detector
Lens filter ejector
Protective case with lens filter storage
Batteries included
21 lens filter included
Colour Green
Displayed temperature range: 34 – 42.2 °C (93.2 – 108 °F)
Operating ambient temperature range: 10 – 40 °C (50 – 104 °F)
Storage temperature range: -25 – 55 °C (-13 – 131 °F)
Operating and storage relative humidity: 10 – 95 %RH (non condensing)
Display resolution: 0.1 °C or °F
Accuracy for displayed temperature range Maximum Laboratory Error
35 °C  –  42 °C (95 °F  –  107.6 °F): ± 0.2 °C (± 0.4 °F)
outside this range: ± 0.3 °C (± 0.5 °F)
clinical repeatability: ± 0.2 °C (± 0.4 °F)
Battery life: 2 years / 350 measurements
Service life: 5 years

This thermometer is specified to operate at 1 atmospheric pressure or at altitudes with an atmospheric pressure up to 1 atmospheric pressure (700-1060hPa).

report this ad

Please do not dispose of the product in the household waste at the end of it useful life.To protect the environment, dispose of empty batteries at appropriate collection sites according to national or local regulations.

Manufactured by Key Tronic Corporation (Address: Tomas Becket #2220 Parque Ind. Gema Plant 3 Juarez, Chihuahua C.P. 32380 Mexico) for Kaz Europe Sarl (Address: Place Chauderon 18, CH-1003 Lausanne, Switzerland)