CHAMPION 4500W Dual Fuel Inverter Generator User Guide

CHAMPION 4500W Dual Fuel Inverter Generator User Guide

WARNING:Read the ENTIRE operator’s manual to become familiar with the features of the product before operating.Failure to operate the product correctly can result in damage to the product, personal property and cause serious injury or even death.

www.championpowerequipment.com© Champion Power Equipment 2021.All Rights Reserved.

 

Set Up

  1. Open shipping carton. Assembly > Unpacking

  2. Shipping Support. Assembly > Remove Shipping Support Hardware.  
  3. Connect the battery. Assembly > Connect the Battery. Push two halves of battery connector together tightly.                                                
  4. Add oil. Assembly > Add Engine Oil.Recommended: 5W-30, up to 16.9 fl. oz. (500 ml) DO NOT overfill.     
  5. Move the generator outdoors.                                                                                      Move generator to an open, outdoor area. Point exhaust away. Never run generator in enclosed areas (e.g., not in house or garage).                              Keep all objects at least 5 feet (1.5 m) from generator. Heat from the muffler and exhaust gas can ignite combustible materials.                                                            
  6. Add fuel – Gasoline or Propane (LPG)Assembly > Add Fuel                                                          FOR GASOLINE OPERATION:DO NOT USE E15 OR E85
  7. DO NOT plug in any electrical devices.                                  NEVER START OR STOP THE GENERATOR WITH ELECTRICAL DEVICES CONNECTED OR TURNED ON!
  8. A. Starting the Engine: Gasoline                                                                             Electric Start1. Turn the EZ Start Dial to the full “CHOKE” position.2. Press and hold ignition switch on EZ Start Dial.3. Turn the EZ Start Dial to the full “RUN” position.       Manual Start1. Turn the EZ Start Dial to the full “CHOKE” position.2. Pull the recoil to start the engine.3. Turn the EZ Start Dial to the full “RUN” position.   B.  Starting the Engine: Propane (LPG)                                                                       Electric Start1. Open the propane tank valve.2. Turn the EZ Start Dial to the full “CHOKE” position.3. Press and hold ignition switch on EZ Start Dial for 2 – 3 seconds.4. Turn the EZ Start Dial to the full “RUN” position.5. Press and hold ignition switch on EZ Start Dial for up to 5 secondsor until started.                                                                          Manual Start1. Open the propane tank valve.2. Turn the EZ Start Dial to the full “CHOKE” position.3. Pull the recoil 2-3 times to prime the engine.4. Turn the EZ Start Dial to the full “RUN” position.5. Pull the recoil to start the engine.                                               
  9. Plug in. Operation > Connecting Electrical Loads.

NEED ASSISTANCE OR HAVE A QUESTION?GIVE US A CALL.

1 877 338 0999CHAMPIONPOWEREQUIPMENT.COM

 