CHAUVET DJ INTIMSCAN360 Intimidator Scan User Manual

INTIMSCAN360 Intimidator Scan

User Manual

Table of ContentsTABLE OF CONTENTS1. Before You Begin …………………………………………………………….. 1What Is Included ………………………………………………………………………………. 1 Unpacking Instructions………………………………………………………………………. 1Claims ……………………………………………………………………………………………………… 1Text Conventions ……………………………………………………………………………… 1 Symbols ………………………………………………………………………………………….. 1 Disclaimer ……………………………………………………………………………………….. 1 Intellectual Property ………………………………………………………………………….. 1 Safety Notes…………………………………………………………………………………….. 22. Introduction …………………………………………………………………….. 3Product Overview……………………………………………………………………………… 3 Product Dimensions ………………………………………………………………………….. 33. Setup ………………………………………………………………………………. 4AC Power ………………………………………………………………………………………… 4Fuse Replacement …………………………………………………………………………………….. 4 Power Linking……………………………………………………………………………………………. 4Mounting …………………………………………………………………………………………. 5Orientation………………………………………………………………………………………………… 5 Rigging …………………………………………………………………………………………………….. 54. Operation ………………………………………………………………………… 6Control Panel Operation…………………………………………………………………….. 6 Menu Map ……………………………………………………………………………………….. 6 Configuration (DMX) …………………………………………………………………………. 7Starting Address………………………………………………………………………………………… 7 DMX Personalities……………………………………………………………………………………… 7Gobos……………………………………………………………………………………………… 7 DMX Channel Assignments and Values ………………………………………………. 8DMX Values ……………………………………………………………………………………………… 8Configuration (Standalone) ………………………………………………………………… 10Automatic Programs…………………………………………………………………………………… 10 Sound-Active Mode ……………………………………………………………………………………. 10 Sound Sensitivity……………………………………………………………………………………….. 10 Manual Mode…………………………………………………………………………………………….. 10Configuration (Settings) …………………………………………………………………….. 11Pan Reverse……………………………………………………………………………………………… 11 Tilt Reverse ………………………………………………………………………………………………. 11 Screen Reverse…………………………………………………………………………………………. 11 Signal Loss……………………………………………………………………………………………….. 11 Indicator……………………………………………………………………………………………………. 11 Flash if DMX……………………………………………………………………………………………… 11 Factory Reset ……………………………………………………………………………………………. 12 System Information ……………………………………………………………………………………. 12IRC-6 Infrared Remote Control …………………………………………………………… 12IRC-6 Operation ………………………………………………………………………………………… 12Master/Slave Mode …………………………………………………………………………… 135. Maintenance…………………………………………………………………….. 14Product Maintenance ………………………………………………………………………… 146. Technical Specifications ………………………………………………….. 15 Returns……………………………………………………………………………….. 16 Contact Us ………………………………………………………………………….. 17Intimidator Scan 360 User Manual Rev. 2

Before You Begin

1. Before You Begin

What Is Included

· Intimidator Scan 360 · Power cord

· Quick Reference Guide

Unpacking InstructionsCarefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.ClaimsIf the box or the contents (the product and included accessories) appear damaged from shipping, or show signs of mishandling, notify the carrier immediately, not Chauvet. Failure to report damage to the carrier immediately may invalidate your claim. In addition, keep the box and contents for inspection. For other issues, such as missing components or parts, damage not related to shipping, or concealed damage, file a claim with Chauvet within 7 days of delivery.Text Conventions

Convention 1­512 50/60Settings <ENTER>ON

Meaning A range of values A set of values of which only one can be chosen A menu option not to be modified A key to be pressed on the product’s control panel A value to be entered or selected

Symbols

Symbol

Meaning

Electrical warning. Not following these instructions may cause electrical damage to the product, accessories, or the user.Critical installation, configuration, or operation information. Not following these instructions may make the product not work, cause damage to the product, or cause harm to the operator.Important installation or configuration information. The product may not function correctly if this information is not used.

Useful information.

DisclaimerChauvet believes that the information contained in this manual is accurate in all respects. However, Chauvet assumes no responsibility and specifically disclaims any and all liability to any party for any loss, damage or disruption caused by any errors or omissions in this document, whether such errors or omissions result from negligence, accident or any other cause. Chauvet reserves the right to revise the content of this document without any obligation to notify any person or company of such revision, however, Chauvet has no obligation to make, and does not commit to make, any such revisions. Download the latest version from www.chauvetdj.com.Intellectual PropertyThe works of authorship contained in this manual, including, but not limited to, all design, text and images are owned by Chauvet. © Copyright 2021 Chauvet & Sons, LLC. All rights reserved. Electronically published by Chauvet in the United States of America. CHAUVET, the Chauvet logo, and Intimidator Scan 360 are registered trademarks or trademarks of Chauvet & Sons LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries. Other company and product names and logos referred to herein may be trademarks of their respective companies.

Intimidator Scan 360 User Manual Rev. 2

Page 1 of 17

Before You BeginSafety Notes· This product is not intended for permanent installation. · Always connect the product to a grounded circuit to avoid the risk of electrocution. · Always disconnect the product from the power source before cleaning or replacing the fuse. · Avoid direct eye exposure to the light source while the product is on. · Make sure the power cord is not crimped or damaged. · Never disconnect the product from power by pulling or tugging on the cord. · If mounting the product overhead, always secure to a fastening device using a safety cable. · Make sure there are no flammable materials close to the product when operating. · Do not touch the product’s housing when operating because it may be very hot.· The voltage of the outlet to which you are connecting this product must be within the range stated on the decal or rear panel of the product.· The product is for indoor use only! (IP20) To prevent risk of fire or shock, do not expose the product to rain or moisture.· Always install the product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.· Be sure that no ventilation slots on the product’s housing are blocked. · Never connect the product to a dimmer or rheostat. · Make sure to replace the fuse with another of the same type and rating. · Never carry the product from the power cord or any moving part. · The maximum ambient temperature is 104 °F (40 °C). Do not operate this product at highertemperatures. · In the event of a serious operating problem, stop using the product immediately. · Do not open this product. It contains no user-serviceable parts. · To eliminate unnecessary wear and improve its lifespan, during periods of non-use completelydisconnect the product from power via breaker or by unplugging it.Keep this User Manual for future use. If the product is sold to someone else, be sure that they also receive this document.

Page 2 of 17

Intimidator Scan 360 User Manual Rev. 2

Introduction2. IntroductionProduct OverviewMounting bracket

Mirror

LensDisplaySafety cable pass-through

Bracket adjustment knob

Menu buttons

Product Dimensions

DMX in/out

Power in/out

6 in 155 mmIntimidator Scan 360 User Manual Rev. 2

A16.3 in 415 mm10 in 255 mmPage 3 of 17

Setup

3. SetupAC PowerThe Intimidator Scan 360 has an auto-ranging power supply and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart. The listed current rating indicates the product’s average current draw under normal conditions.· Always connect the product to a protected circuit (a circuit breaker or fuse). Make sure the product has an appropriate electrical ground to avoid the risk of electrocution or fire.· To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.Never connect the product to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel serves only as a 0 to 100% switch.

Fuse Replacement1. Disconnect the product from power. 2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder. 3. Pry the fuse holder out of the housing. 4. Remove the blown fuse from the holder and replace with a fuse of the exact same type and rating. 5. Insert the fuse holder back in place and reconnect power.Installed fuse(held by plastic clip)

Spare fuse holder(inside safety cap)

Safety cap

Disconnect the product from the power outlet before replacing the fuse.Power LinkingThe product provides power linking via the outlets located in the back of the product. See the diagram below for further explanation. Power Linking Diagram

Additional products

3rd Product

2nd Product

1st Product

Power Source

You can power link up to 4 Intimidator Scan 360 products on 120 VAC or up to 7 products on 230 VAC.The power linking diagram shown above corresponds to the North American version of the product ONLY! If using the product in other markets, you must consult with the local Chauvet distributor as power linking connectors and requirements may differ in your country or region.

Page 4 of 17

Intimidator Scan 360 User Manual Rev. 2

SetupMountingBefore mounting the product, read and follow the safety recommendations indicated in the Safety Notes.OrientationThe Intimidator Scan 360 may be mounted in any position; however, make sure adequate ventilation is provided around the product.Rigging· Before deciding on a location, always make sure there is easy access to the product for maintenance and programming.· Make sure adequate ventilation is provided around the product. · Make sure that the structure or surface onto which you are mounting the product can support theproduct’s weight. (see the Technical Specifications) · When mounting the product overhead, always use a safety cable. Mount the product securely to arigging point, whether an elevated platform or a truss. · When rigging the product onto a truss, use a mounting clamp of appropriate weight capacity. · When power linking multiple products, mount the products close enough for power linking cables toreach. · The rubber feet also serve as floor supports and allow for surface mounting. When mounting theproduct on the floor, make sure that the product and cables are away from people and vehicles. Mounting DiagramMounting clamp(such as CLP-10 from Chauvet)

Mounting bracket

Safety cable(such as CH-05 from Chauvet)Safety cable pass-through

When using only one mounting clamp with this fixture, you must use a clamp with a captive bolt to prevent accidental loosening.

Intimidator Scan 360 User Manual Rev. 2

Page 5 of 17

Operation

4. Operation

Control Panel OperationTo access the control panel functions, use the four buttons located underneath the display. Please refer to the Product Overview to see the button locations on the control panel.Button Function

<MENU> <UP><DOWN> <ENTER>

Press to find an operation mode or to back out of the current menu option Press to scroll up the list of options or to increase the numeric value in a function Press to scroll down the list of options or to decrease the numeric value in a function Press to activate a menu option or set the selected value in a function

Menu Map

Refer for the Intimidator Scan 360 product page on www.chauvetdj.com for the latest menu map.

Main Function Address Run ModeSetup

Programming Levels

001­512

DMX

8Ch 12Ch

Slave

Auto

Sound

IR

Pan

Tilt

Color

Gobo

Manual

Gobo Rotate

000­255

Prism

Focus

Dimmer

Strobe

Pan Reverse

OFF ON

Tilt Reverse

OFF ON

Screen Reverse

OFF ON

Blackout

Signal Loss

Hold Auto

Sound

Sensitivity

001­100

Indicator

OFF ON

Flash if DMX

OFF ON

Reset

Description Sets the DMX starting addressSelects DMX modeSets unit to Slave mode Sets unit to Auto mode Sets unit to Sound-active mode Sets unit to infrared control mode Controls pan settings Controls tilt settings Selects color options Selects gobo optionsControls gobo rotation effectsSelects prism effects Controls focus Sets dimmer value Controls strobe effects Normal pan operation Reverse pan operation Normal tilt operation Reverse tilt operation Normal display Reverse display Turns the unit off when DMX signal is lost Holds the last setting when DMX signal is lost Sets the unit to Auto mode when signal is lost Sets the unit to Sound mode when signal is lost Sound sensitivity controlTurns indicator on or offLED Indicator flashes when DMX is turned ON or OFF Revert to factory settings

Page 6 of 17

Intimidator Scan 360 User Manual Rev. 2

OperationMain FunctionSys Info

Programming Levels

Description

Ver

V_._ Displays software version

Running Mode

_ _ _ _ _ _ _ Displays current running mode

DMX Address

_ _ _ Displays current DMX mode

Temperature

_ _ _ Displays the product temperature in Celsius

Configuration (DMX)The Intimidator Scan 360 works with a DMX controller. Information about DMX is in the CHAUVET DMX Primer, which is available from the Chauvet website http://www.chauvetlighting.com/downloads/ DMX_Primer_rev05_WO.pdf.Starting AddressWhen selecting a starting DMX address, always consider the number of DMX channels the selected DMX mode uses. If the starting address is set too high, access to some of the product’s channels could be restricted. The Intimidator Scan 360 uses up to 12 DMX channels, which defines the highest configurable address to 501. For information about the DMX protocol, download the DMX Primer from www.chauvetdj.com. To select the starting address, do the following:1. Press <MENU> repeatedly until Address shows on the display. 2. Press <ENTER>. 3. Use <UP> or <DOWN> to select the starting address, from 001­512. 4. Press <ENTER>.DMX PersonalitiesThe Intimidator Scan 360 has two DMX personalities: an 8-channel personality and a 14-channel personality. To select a DMX personality, follow the instructions below.1. Press <MENU> repeatedly until Run Mode shows on the display. 2. Press <ENTER>. 3. Use <UP> or <DOWN> to select DMX. 4. Press <ENTER>. 5. Use <UP> or <DOWN> to select the DMX personality, from 12CH or 08CH. 6. Press <ENTER>.Gobos

Intimidator Scan 360 User Manual Rev. 2

Page 7 of 17

Operation

DMX Channel Assignments and Values

DMX Values

8Ch

12Ch

1

1

2

2

3

Function Pan Tilt Pan/tilt speed

3

4

Color

4

5

Gobo wheel (see Gobos)

5

6

Gobo rotation

6

7

Prism

Value Percent/Setting 000 255 0­172° 000 255 0­39° 000 255 Fast to slow 000 006 Open 007 013 Orange 014 020 Lime 021 027 Cyan 028 034 Red 035 041 Green 042 048 Magenta 049 055 Yello 056 062 Blue 063 064 White 065 189 Split colors 190 221 Clockwise scroll, fast to slow 222 223 Stop 224 255 Counterclockwise scroll, slow to fast 000 007 Open 008 015 Gobo 1 016 023 Gobo 2 024 031 Gobo 3 032 039 Gobo 4 040 047 Gobo 5 048 055 Gobo 6 056 063 Gobo 7 064 071 Gobo 7 shaking, slow to fast 072 079 Gobo 6 shaking, slow to fast 080 087 Gobo 5 shaking, slow to fast 088 095 Gobo 4 shaking, slow to fast 096 103 Gobo 3 shaking, slow to fast 104 111 Gobo 2 shaking, slow to fast 112 119 Gobo 1 shaking, slow to fast 120 127 Open 128 189 Clockwise rotation, fast to slow 190 193 Stop 194 255 Counterclockwise rotation, slow to fast 000 063 Gobo index 064 145 Clockwise rotation, slow to fast 146 149 Stop 150 231 Counterclockwise rotation, slow to fast 232 255 Boomerang, short to long 000 015 No function 016 127 Prism on (static) 128 255 Clockwise rotation, slow to fast

Page 8 of 17

Intimidator Scan 360 User Manual Rev. 2

Operation

8Ch

12Ch Function

7

8

Focus

9

Dimmer

8

10 Strobe

11 Functions

12

Movement macros

Value Percent/Setting

000 255 0­100%

000 255 0­100%

000 003 No function

004 007 Open

008 076 Synchronized strobe, slow to fast

077 145 Pulse strobe, slow to fast

146 215 Random strobe, slow to fast

216 255 Open

000 007 No function

008 015 Blackout on pan/tilt movement

016 023 Blackout on color wheel movement

024 031 Blackout on gobo wheel movement

032 039 Blackout on pan/tilt/color wheel movement

040 047 Blackout on pan/tilt/gobo wheel movement

048

055

Blackout on movement

pan/tilt/color

wheel/gobo

wheel

056 095 No function

096 103 Pan reset

104 111 Tilt reset

112 119 Color reset

120 127 Gobo reset

128 135 No function

136 143 Prism reset

144 151 Focus reset

152 159 All reset

160 255 No function

000 007 No function

008 023 Movement macro 1

024 039 Movement macro 2

040 055 Movement macro 3

056 071 Movement macro 4

072 087 Movement macro 5

088 103 Movement macro 6

104 119 Movement macro 7

120 135 Movement macro 8

136 151 Sound-active movement macro 1

152 167 Sound-active movement macro 2

168 183 Sound-active movement macro 3

184 199 Sound-active movement macro 4

200 215 Sound-active movement macro 5

216 231 Sound-active movement macro 6

232 247 Sound-active movement macro 7

248 255 Sound-active movement macro 8

Intimidator Scan 360 User Manual Rev. 2

Page 9 of 17

OperationConfiguration (Standalone)Set the product in one of the standalone modes to control without a DMX controller.Never connect a product that is operating in any standalone mode to a DMX string connected to a DMX controller. Products in standalone mode may transmit DMX signals that could interfere with the DMX signals from the controller.Automatic ProgramsTo run the Intimidator Scan 360 in automatic mode, follow the instructions below: 1. Press <MENU> repeatedly until Run Mode shows on the display. 2. Press <ENTER>. 3. Use <UP> or <DOWN> to select Auto. 4. Press <ENTER>.Sound-Active ModeTo run the Intimidator Scan 360 in sound-active mode, do the following: 1. Press <MENU> repeatedly until Run Mode shows on the display. 2. Press <ENTER>. 3. Use <UP> or <DOWN> to select Sound. 4. Press <ENTER>.Sound SensitivityTo set the sound sensitivity on the Intimidator Scan 360, follow the instructions below: 1. Press <MENU> repeatedly until Setup shows on the display. 2. Press <ENTER>. 3. Use <UP> or <DOWN> to select Sound Sensitivity. 4. Press <ENTER>. 5. Use <UP> or <DOWN> to increase or decrease the sound sensitivity, from 001­100. 6. Press <ENTER>.The product will only respond to low frequencies of music (bass and drums).Manual ModeTo operate the Intimidator Scan 360 manually through the menu, do the following: 1. Press <MENU> repeatedly until Run Mode shows on the display. 2. Press <ENTER>. 3. Use <UP> or <DOWN> to select Manual. 4. Press <ENTER>. 5. Use <UP> or <DOWN> to select from Pan, Tilt, Color, Gobo, Gobo Rotate, Prism, Focus, Dimmer, or Strobe. 6. Press <ENTER>. 7. Use <UP> or <DOWN> to increase or decrease the value of the function, from 000­255. 8. Press <ENTER>. 9. Repeat steps 3-6 until the product is set as desired.

Page 10 of 17

Intimidator Scan 360 User Manual Rev. 2

OperationConfiguration (Settings)Pan ReverseTo set the pan orientation on the Intimidator Scan 360, follow the instructions below: 1. Press <MENU> repeatedly until Setup shows on the display. 2. Press <ENTER>. 3. Press <MENU> repeatedly until Pan Reverse shows on the display. 4. Press <ENTER>. 5. Use <UP> or <DOWN> to select OFF (normal pan orientation) or ON (reverse pan orientation). 6. Press <ENTER>.Tilt ReverseTo set the tilt orientation on the Intimidator Scan 360, do the following: 1. Press <MENU> repeatedly until Setup shows on the display. 2. Press <ENTER>. 3. Press <MENU> repeatedly until Tilt Reverse shows on the display. 4. Press <ENTER>. 5. Use <UP> or <DOWN> to select OFF (normal tilt orientation) or ON (reverse tilt orientation). 6. Press <ENTER>.Screen ReverseTo set the screen display on the Intimidator Scan 360, follow the instructions below: 1. Press <MENU> repeatedly until Setup shows on the display. 2. Press <ENTER>. 3. Press <MENU> repeatedly until Screen Reverse shows on the display. 4. Press <ENTER>. 5. Use <UP> or <DOWN> to select OFF (normal screen display) or ON (reverse screen display). 6. Press <ENTER>.Signal LossTo set the action that the Intimidator Scan 360 does once DMX signal is lost, follow the instructions below: 1. Press <MENU> repeatedly until Setup shows on the display. 2. Press <ENTER>. 3. Press <MENU> repeatedly until Signal Loss shows on the display. 4. Press <ENTER>. 5. Use <UP> or <DOWN> to select Blackout (turns the unit off), Hold (retains the last setting), Auto (sets the unit to Auto mode), or Sound (sets the unit to Sound mode). 6. Press <ENTER>.IndicatorTo enable or disable the LED indicator, do the following: 1. Press <MENU>. 2. Use <UP> or <DOWN> to select Setup. 3. Press <ENTER>. 4. Use <UP> or <DOWN> to select Indicator. 5. Press <ENTER>. 6. Use <UP> or <DOWN> to select OFF (disabled) or ON (enabled). 7. Press <ENTER>.Flash if DMXTo enable or disable the LED indicator flashing to indicate DMX, do the following: 1. Press <MENU>. 2. Use <UP> or <DOWN> to select Setup. 3. Press <ENTER>. 4. Use <UP> or <DOWN> to select Flash if DMX. 5. Press <ENTER>. 6. Use <UP> or <DOWN> to select OFF (will not indicate DMX) or ON (Will indicate DMX). 7. Press <ENTER>.

Intimidator Scan 360 User Manual Rev. 2

Page 11 of 17

Operation

Factory ResetTo restore the Intimidator Scan 360 to factory default settings, follow the instructions below: 1. Press <MENU> repeatedly until Setup shows on the display. 2. Press <ENTER>. 3. Select Reset to revert the fixture to its default factory settings. 4. Press <ENTER>.System InformationTo view the system information on the Intimidator Scan 360, do the following: 1. Press <MENU>. 2. Use <UP> or <DOWN> to select Sys Info. 3. Press <ENTER>. 4. Select Ver (displays the fixture’s software version), Running Mode (displays the current running mode), DMX Address (displays the current DMX mode), and Temperature (displays the fixture’s current temperature in Celsius).

IRC-6 Infrared Remote ControlThe Intimidator Scan 360 is compatible with the IRC-6 infrared remote control from Chauvet. To set the Intimidator Scan 360 to IR mode, follow the instructions below:1. Press <MENU> repeatedly until Run Mode shows on the display. 2. Press <ENTER>. 3. Press <UP> or <DOWN> to select IR. 4. Press <ENTER>.IRC-6 Operation

Automatic Mode

Automatic mode will enable you to run the automatic programs on the product.

To turn on Automatic mode:

BLACK OUT

AUTO

SOUND

· Press <AUTO> on the IRC-6.

STROBE

SPEED

SENSITIVITY

%

MANUAL

FADE

RGB

A UV W +0-

To adjust the speed of the automatic program: 1. Press <SPEED> on the IRC-6. 2. Press <+> or <­> to increase or decrease the speed of the program.Sound-Active Mode Sound-Active mode will enable the product to respond to the music. To turn on Sound-Active mode:· Press <SOUND> on the IRC-6.

123 456 789

Sound Sensitivity · To adjust the fixture’s sensitivity to sound: 1. Press <SENSITIVITY> on the IRC-6. 2. Press <+> or <­> to increase or decrease the sound sensitivity.

To set all LEDs to full intensity: · Press <0> on the IRC-6.

Miscellaneous Operation To adjust the output level of the LEDs in manual color mode:· Press <%> repeatedly on the IRC-6.

To black out the lights:· Press <BLACK OUT> on the IRC-6.This will turn off all the lights until the button is pressed again. NOTE: The IRC-6 will not respond to any inputs when Black Out is activated. If the remote does not respond when a button is pressed, try pressing <BLACK OUT>. You may have inadvertently activated Black Out.

Page 12 of 17

Intimidator Scan 360 User Manual Rev. 2

OperationMaster/Slave ModeThe Master/Slave mode allows a single Intimidator Scan 360 product (the “master”) to control the actions of one or more Intimidator Scan 360 products (the “slaves”) without the need of a DMX controller. The master product will be set to operate in either standalone mode or with the IRC-6, while the slave products will be set to operate in slave mode. Once set and connected, the slave products will operate in unison with the master product. Configure the products as indicated below. Slave products:1. Press <MENU>. 2. Use <UP> or <DOWN> to select Run Mode. 3. Press <ENTER>. 4. Use <UP> or <DOWN> to select Slave. 5. Press <ENTER>. 6. Connect the DMX input of the first slave product to the DMX output of the master product. 7. Connect the DMX input of the subsequent slave products to the DMX output of the previous slaveproduct. 8. Finish setting and connecting all the slave products. Master product: 1. Set the master product to operate in standalone mode. 2. Make the master product the first product in the DMX daisy chain.· Configure all the slave products before connecting the master to the daisy chain.· Never connect a DMX controller to a DMX string configured for Master/Slave operation because the controller may interfere with the signals from the master.· Do not connect more than 31 slaves to the master.

Intimidator Scan 360 User Manual Rev. 2

Page 13 of 17

Maintenance5. MaintenanceProduct MaintenanceDust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, clean your lighting products at least twice a month. However, be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency. To clean the product, follow the instructions below:1. Unplug the product from power. 2. Wait until the product is at room temperature. 3. Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the externalsurface/vents. 4. Clean all transparent surfaces with a mild soap solution, ammonia-free glass cleaner, or isopropylalcohol. 5. Apply the solution directly to a soft, lint free cotton cloth or a lens cleaning tissue. 6. Softly drag any dirt or grime to the outside of the transparent surface. 7. Gently polish the transparent surfaces until they are free of haze and lint.Always dry the transparent surfaces carefully after cleaning them.Do not spin the cooling fans using compressed air because they could be damaged.

Page 14 of 17

Intimidator Scan 360 User Manual Rev. 2

Technical Specifications

6. Technical Specifications

Dimensions and Weight Length10 in (255 mm)

Width 6 in (155 mm)

Height 16.3 in (415 mm)

Note: Dimensions in inches rounded to the nearest decimal digit.

Power

Power Supply Type

Range

Switching (internal)

100 to 240 VAC, 50/60 Hz

Weight 12.6 lb (5.7 kg)Voltage Selection Auto-ranging

ParameterConsumption Operating currentPower linking Fuse

120 V, 60 Hz147 W 1.9 A 8 A (4 products) F 3 A, 250 V

230 V, 50 Hz143 W 1.1 A 8 A (7 products) F 3 A, 250 V

Power I/O Power input connectorPower cord plug

U.S./Worldwide IECEdison (U.S.)

UK/Europe IECLocal plug

Light Source Type LED

Color White

Quantity 1

Power 100 W

Current 4.2 A

Lifespan 50,000 hours

Photometrics Strobe Rate 0 to 20 HzThermal Maximum External Temperature104 °F (40 °C)

Beam Angle 2°Cooling System Fan-assisted convection

Illuminance @ 2 m 4,050 lux

DMX

I/O Connector 3-pin XLR

Channel Range 8 or 12

Ordering Product NameIntimidator Scan 360

Item Code 07021724

UPC Number 781462220723

Intimidator Scan 360 User Manual Rev. 2

Page 15 of 17

ReturnsReturnsIn case you need to get support or return a product: · If you are located in the U.S., contact Chauvet World Headquarters. · If you are located in the U.K. or Ireland, contact Chauvet Europe Ltd. · If you are located in Benelux, contact Chauvet Europe BVBA. · If you are located in France, contact Chauvet France. · If you are located in Germany, contact Chauvet Germany. · If you are located in Mexico, contact Chauvet Mexico. · If you are located in any other country, DO NOT contact Chauvet. Instead, contact your local distributor. See www.chauvetdj.com for distributors outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico.If you are located outside the U.S., UK, Ireland, Benelux, France, Germany, or Mexico, contact your distributor of record and follow their instructions on how to return Chauvet products to them. Visit our website www.chauvetdj.com for contact details.Call the corresponding Chauvet Technical Support office and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause for the return. To submit a service request online, go to www.chauvetdj.com/service-request. Send the merchandise prepaid, in its original box, and with its original packing and accessories. Chauvet will not issue call tags. Clearly label the package with the RMA number. Chauvet will refuse any product returned without an RMA number.Write the RMA number on a properly affixed label. DO NOT write the RMA number directly on the box.Before sending the product, clearly write the following information on a piece of paper and place it inside the box:· Your name · Your address · Your phone number · RMA number · A brief description of the problem Be sure to pack the product properly. Any shipping damage resulting from inadequate packaging will be your responsibility. FedEx packing or double-boxing are recommended.Chauvet reserves the right to use its own discretion to repair or replace returned product(s).

Page 16 of 17

Intimidator Scan 360 User Manual Rev. 2

Contact Us

Contact UsGeneral InformationChauvet World Headquarters Address: 5200 NW 108th Ave. Sunrise, FL 33351 Voice: (954) 577-4455 Fax: (954) 929-5560 Toll Free: (800) 762-1084Chauvet Europe Ltd Address: Unit 1CBrookhill Road Industrial Estate Pinxton, Nottingham, UK NG16 6NTVoice: +44 (0) 1773 511115 Fax: +44 (0) 1773 511110Chauvet Europe BVBA Address: Stokstraat 18 9770 Kruishoutem Belgium Voice: +32 9 388 93 97Chauvet France Address: 3, Rue Ampère 91380 Chilly-Mazarin France Voice: +33 1 78 85 33 59Chauvet Germany Address: Bruno-Bürgel-Str. 11 28759 Bremen Germany Voice: +49 421 62 60 20Chauvet Mexico Address: Av. de las Partidas 34 – 3B (Entrance by Calle 2) Zona Industrial Lerma Lerma, Edo. de México, CP 52000 Voice: +52 (728) 690-2010

Technical Support Voice: (844) 393-7575 Fax: (954) 756-8015Email: Website: www.chauvetdj.comEmail: Website: www.chauvetdj.euEmail: Website: www.chauvetdj.euEmail: Website: www.chauvetdj.euEmail: Website: www.chauvetdj.euEmail: Website: www.chauvetdj.mx

Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact the dealer of record. Follow the instructions to request support or to return a product. Visit our website for contact details.

Intimidator Scan 360 User Manual Rev. 2

Page 17 of 17

[xyz-ips snippet=”download-snippet”]


Posted

in

by