CHAUVET Ovation CYC 1 FC User Guide

OVATION CYC 1 FC

Quick Reference Guide

About This Guide

The Ovation Cyc 1 FC Quick Reference Guide (QRG) has basic product information such as connection, mounting, menu options, and DMX values. Download the User Manual from www.chauvetprofessional.com for more details.DisclaimerThe information and specifications contained in this QRG are subject to change without notice.

LIMITED WARRANTY

FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.For Customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration.For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www. Chauvetlighting.EU/warranty-registration.Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.

Safety Notes

  • DO NOT open this product. It contains no user-serviceable parts.
  • DO NOT look at the light source when the product is on.
  • DO NOT operate this product outdoors or in any location where dust, excessive heat, water, or humidity may affect it (IP20).
  • DO NOT leave any flammable material within 50 cm of this product while operating or connected to power. ·
  • DO NOT operate this product if the housing, lenses, or cables appear damaged.
  • DO NOT connect this product to a dimmer or rheostat.
  • CAUTION: This product’s housing may be hot when lights are operating.
  • CAUTION: When transferring products from extreme temperature environments, (e.g., cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow the product to fully acclimate to the surrounding environment before connecting it to power.
  • USE a safety cable when mounting this product overhead.
  • ONLY connect this product to a grounded and protected circuit.
  • ONLY use the hanging/mounting bracket to carry this product.
  • Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via a breaker or by unplugging it.
  • In the event of a serious operating problem, stop using immediately.
  • The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.

FCC Compliance

This device complies with Part 15 Part B of the FCC Rules. Operations are subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

ContactOutside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or return a product. Refer to Contact Us at the end of this QRG for contact information.

What is Included

  • Ovation Cyc 1 FC
  • Neutrik® powerCON® power cord
  •  Omega Bracket with mounting hardware
  • Quick Reference Guide

AC Power

This product has an auto-ranging power supply that can work with an input voltage range of 100­240 VAC, 50/60 Hz.Power Linking

You can link up to 11 Ovation Cyc 1 FC products at 120 V, 20 products at 208 V, or 22 products at 230 V. Never exceed this number. Power linking cords can be purchased separately.

AC Plug

Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow/Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green

To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.

Replacing the Fuse

  1. Disconnect this product from power.
  2. Using a Phillips #2 head screwdriver, unscrew the fuse holder cap from the housing.
  3. Remove blown fuse and replace with a good fuse of the same type and rating.
  4. Screw the fuse holder cap back in place and reconnect power.

DMX LinkingThe Ovation Cyc 1 FC will work with a DMX controller using a 5-pin DMX serial connection. A DMX Primer is available from www.chauvetprofessional.com.DMX ConnectionThe Ovation Cyc 1 FC uses a wireless DMX data connection for its DMX personalities: 1Ch, 3Ch, 5Ch, 7Ch, 10Ch, 12Ch, 13Ch, 16Ch, and HSV. See the User Manual for information about connecting and configuring the product for DMX operation.Master/Slave ConnectionThe Ovation Cyc 1 FC uses the DMX data connection for its Master/Slave mode. See the User Manual for information about connect and configure the product for master/slave operation.RDM (Remote Device Management)Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally along with existing DMX cabling. Check the DMX controller’s User Manual or with the manufacturer as not all DMX controllers have this capability. The Ovation Cyc 1 FC supports the RDM protocol that allows feedback to make changes to some menu map options. Download the User Manual from www.chauvetprofessional.com for more details.MountingBefore mounting this product, read the Safety Notes. Make sure the mounting clamps are capable of supporting the weight of the product. For our Chauvet line of mounting clamps, go to http://trusst.com/productcategory/truss-clamps/.

Product Mounting Diagram

Virtual Color Wheel

The Ovation Cyc 1 FC includes a feature called the Virtual Color Wheel (VCW). This feature is available as a standalone control mode for manual use and as a control channel in select DMX personalities. More than 30 premixed colors, custom-blended by Chauvet engineers, are available to call up for easier programming. The DMX values used to mix these colors are provided below. The overall intensity of the Ovation fixture can be adjusted to more closely replicate familiar industry-standard colors. A chart is available at www.chauvetprofessional.com to compare Chauvet’s premixed colors with popular gel colors. This chart is for comparison purposes only and is not an assertion that Chauvet’s premixed colors match any of the gel colors listed.

Virtual Color Wheel Chart

  Display Readout Red Value Green Value Blue Value Amber Value Lime Value
000 c 005 000 000 000 000 000
006 <=> 013 C3050-Md Yellow 233 163 020 123 255
014 <=> 021 C3040–  Lt Yellow 224 158 047 255 231
022 <=> 028 C3240-– –Amb Yellow 180 060 000 245 255
029 <=> 035 C2340 VLt Amber 245 107 081 255 213
036 <=> 043 C2040 Lt Amber 230 130 062 255 155
044 <=> 051 C2050 Md Amber 255 000 025 255 194
052 <=> 059 C2060 Dk Amber 255 000 024 255 150
060 <=> 067 C1050 Lt Red 255 037 027 030 038
068 <=> 075 C1080 Md Red 255 004 017 000 000
076 <=> 083 C1020 NC Pink 238 135 129 255 255
084 <=> 091 C1030 Md Pink 255 131 120 255 195
092 <=> 099 C1630 Dk Pink 255 165 123 255 210
100 <=> 107 C1250 Md Red Amber 255 000 041 195 055
108 <=> 115 C1060 Dk Red Amber 255 000 045 120 030
116 <=> 121 C1650 Magenta 255 050 115 255 115
122 <=> 130 C6170 Dk Magenta 255 035 117 000 000
131 <=> 138 C6020 Lt Lavender 127 122 142 251 255
139 <=> 146 C5030 Lt Blue 000 255 197 100 255
147<=> 154 C5020 VLt Blue 158 255 189 000 255
155 <=> 162 C5430 Lt Blue 2 000 255 180 000 243
163 <=> 170 C5070 Blue 043 255 210 043 036
171 <=> 178 C5050 Md Blue 000 255 218 000 181
179 <=> 186 C5060 Dk Blue 000 210 206 000 118
187 <=> 194 C5690 Indigo 065 000 210 040 055
195 <=> 202 C5080 VDk Blue 000 203 230 000 040
203 <=> 210 C5081 VDk Blue2 040 199 240 000 045
211 <=> 218 C4370 Yel Green 027 255 028 016 104
219 <=> 226 C4070 Green 049 255 055 120 090
227 <=> 234 C4550 Turquoise 060 230 109 000 245
235 <=> 242 C4560 Aqua 020 240 126 036 255
235<=> 242 C4570 Blue Green 000 255 079 030 053
251 <=> 255 000 000 000 000 000

Note: The colors above are simulated renditions of the color output produced compared with other similar incandescent products. Chauvet makes no guarantee of color output accuracy.

Color Temperature Chart

DMX Value Display Readout Red Value Green Value Blue Value Amber Value Lime Value
000=> 005 000 000 000 000 000
 006 <=> 025 2800K 172 110 037 255 255
 026 <=> 050 3000K 156 126 044 255 255
051 <=> 075 3200K 144 142 049 255 255
076 <=> 100 3500K 128 159 062 255 255
101 <=>125 4000K 096 183 073 255 255
126<=>150 4500K 084 209 091 255 255
151 <=> 175 5000K 074 221 109 255 255
176 <=> 200 5600K 064 244 126 255 255
  201 <=> 225 6000K 059 255 137 255 255
 226 <=> 250 6500K 050 255 148 255 255
 251 <=> 255 000 000 000 000 000

The color temperatures above are simulated renditions of the color output produced as compared to a tungsten lamp at the specified color temperature. Chauvet makes no guarantee of color output accuracy.

Control Panel Description

Button Function
<MENU> Exits from the current menu or function
<ENTER>  Enables the currently displayed menu or sets the currently selected value into the selected function
<UP>  Navigates upwards through the menu list or increases the numeric value when in a function
<DOWN>  Navigates downwards through the menu list or decreases the numeric value when in a function

PasscodeAfter being prompted, enter the following passcode by pressing: <UP>, <DOWN>, <UP>, <DOWN>, <ENTER>. This passcode cannot be changed and must be used whenever prompted.

Menu Map

Main Level Programming Levels Description
StartAddress 001-512* Selects starting address (*highest channel restricted to personality chosen)
DMX Channel 1Ch Virtual Color Wheel 1-channel: dimmer,  —- See Virtual Color Wheel Chart
Color Temperature   See Color Temperature Chart
Manual ColorMixer Red 0-255 Combine red, green, blue, amber, and lime to make custom color (0-100%)
Green
Blue
Amber
Lime
3Ch 3-channel: Dimmer, virtual color wheel, color temperature
5Ch 5-channel: RGBAL
7Ch 7-channel: Dimmer, RGBAL, strobe
10Ch 10-channel: 16-bit dimmer, RGBAL, strobe, virtual color wheel, color temperature
12Ch 12-channel: Dimmer, RGBAL, strobe, virtual color wheel, color temperature, auto programs, auto speed, control
13Ch 13-channel: 16-bit dimmer, 16-bit RGBAL, strobe
16Ch 16-channel: 16-bit dimmer, 16-bit RGBAL, strobe, virtual color wheel, color temperature, control
HSV 3-channel: HSV control

 

Programming Levels Description
Virtual ColorWheel C3050 – Md Yellow Dimmer000-255 Virtual Color Wheel simulates the output of each gel color. Refer to the

Virtual Color Wheel Chart section for

C3040 – Lt Yellow
C3240 – Amb Yellow
C2340 – VLt Amber
C2040 – Lt Amber
C2050 – Md Amber
C2060 Dk Amber
C1050 – Lt Red
C1080 – Md Red
C1020 NC Pink
C1030 – Md Pink
C1630 – Dk Pink
C1250 – Md Red Amber
C1060 – Dk Red Amber
C1650 – Magenta
C6170 – Dk Magenta
C6020 – Lt Lavender specific values.
C5030 – Lt Blue
C5020 – VLt Blue
C5430 – Lt Blue 2
C5070 Blue
C5050 Md Blue
C5060 – Dk Blue
C5690 Indigo
C5080 VDk Blue
C5081 – VDk Blue 2
C4370 – Yel Green
C4070 – Green
C4550 – Turquoise
C4560 Aqua
C4570 – Blue Green
ColorTemperature 2800K Preset white color temperatures. Emulates a tungsten lamp at the specified color temperature. Refer to the

Color Temperature Chart section for

3000K
3200K
3500K
4000K
4500K
5000K specific values.
5600K
6000K
6500K
Manual ColorMixer Red Combine red, green, blue, amber, and lime to make a custom color (0-100%)
Green
Blue
Amber
Lime

 

Main Level

Programming Levels

Description

Auto Show Auto 1

Speed 001-100

Selects automatic programs and auto program speed
Auto 2
Auto 3
Auto 4
Auto 5
Red Shift

On

Turns on or off Red Shift (amber LEDs

Ott

imitate lamp when dimming)
Master/Slave

Master

Slave

DimmerCurve

S Curve

Linear

Index Curve

Log Curve

DimmerMode

Off

Linear dimmer

Dimmer 1

Fast dimmer curve

Dimmer 2

Medium dimmer curve

Dimmer 3

Slow dimmer curve
WhiteBalance

Off

Manual

Red

125-255

Green

Blue

Amber

Lime

LEDFrequency

600Hz

Selects the PWM output frequency

1200Hz

2000Hz

4000Hz

6000Hz

25KHz

Back Light

I OS

Turns off display backlight after 10 seconds of inactivity

305

Turns off display backlight after 30 seconds of inactivity

2Min

Turns off display backlight after 2 minutes of inactivity

Always On

Display backlight always an

Shows total product hours

Information Fixture Hours

___H

LEO Hours

–­H

Shows total LED hours
Version

V_._

Shows installed software version
UID

 ——————————————————————– Shows product UID

Factory Reset

No

Reset to factory defaults

Yes

DMX valuesHSV

Channel Function Value Percent/Setting
1 Hue 000<=>255 0-100%
2 Saturation 000 <=> 255 0-100%
3 Value 000<=> 255 0-100%

16Ch

hannel Function Value Percent/Setting
1 Dimmer 000<=>255 0-100%
2 Dimmer Fine 000<=> 255 0-100%
3 Red 000 <=>255 0-100%
4 Red Fine 000<=> 255 0-100%
5 Green 000<=>255 0-100%
6 Green Fine 000 <=>255 0-100%
7 Blue 000<=>255 0-100%
8 Blue Fine 000 <=>255 0-100%
9 Amber 000 <=>255 0-100%
10 Amber Fine 000 <=>255 0-100%
11 Lime 000 <=> 255 0-100%
12 Lime Fine 000 <=> 255 0-100%
13 Strobe 000<=> 010 No function
011 <=>255 Strobe, slow to fast
14 Virtual Color Wheel 000<=>255 Refer to the Virtual Color Wheel Chart section for specific values
Color Temperature
15 000<=>255 Refer to the Color Temperature Chart section for specific values
000 <=>007
No function
008<=> 015 Dimmer reset
016 <=> 023 Red shift on
024 <=>031 Red shift off
032 <=>039 S-curve dimmer
040 <=>047 Linear dimmer
16

 

 

 

 

 

 

Control

(hold for 3 seconds)

 

 

 

 

 

 

048 <=> 055 Index dimmer curve
056 <=>063 Logarithmic dimmer curve
064 <=> 071 Dimmer speed mode OFF
072 <=> 079 Dimmer speed 1 (fastest)
080 <=> 087 Dimmer speed 2
088 <=> 095 Dimmer speed 3 (slowest)
096 <=> 255 Reserved for future use

13Ch

Channel Function Value Percent/Setting
1 Dimmer 000<=>255 0-100%
2 Dimmer Fine 000<=>255 0-100%
3 Red 000<=>255 0-100%
4 Red Fine 000<=>255 0-100%
5 Green 000<=> 255 0-100%
6 Green Fine 000<=>255 0-100%
7 Blue 000<=>255 0-100%
8 Blue Fine 000 <=>255 0-100%
9 Amber 000 <=>255 0-100%
10 Amber Fine 000 <=>255 0-100%
11 Lime 000 ,<=>255 0-100%
12 Lime Fine 000<=>255 0-100%
13 Strobe 000 ,<=>010011 <=> 255 No function

Strobe, slow to fast

12Ch

Channel Function Value Percent/Setting
1 Dimmer 000<=> 255 0-100%
2 Red 000 <=>255 0-100%
3 Green 000 <=>255 0-100%
4 Blue 000<=>255 0-100%
5 Amber 000<=>255 0-100%
6 Lime 000<=> 255 0-100%
7 Strobe 000 <=> 010 No function
011<=>255 Strobe, slow to fast
8 Virtual Color Wheel 000 <=>255 Refer to the Virtual Color Wheel Chart section for specific values
9 Color Temperature 000 <=> 255 Refer to the Color Temperature Chart section for specific values
000 <=> 010
No function
011 <=>060 Auto 1
061<=>110 Auto 2
10 Auto Program
111 <=> 160 Auto 3
161<=> 210 Auto 4
211<=>255 Auto 5 (Auto 1-4)
11 Auto Speed 000 <=> 255 Auto speed, slow to fast
000<=>007 No function
008 <=> 015 Dimmer reset
016<=> 023 Red shift on
024<=> 031 Red shift off
032 <=>039 S-curve dimmer
040 <=>047 Linear dimmer
12 Control

(hold for 3 seconds)

048 <=> 055 Index dimmer curve
056<=> 063 Logarithmic dimmer curve
064<=>071 Dimmer speed mode OFF
072<=> 079 Dimmer speed 1 (fastest)
080 <=> 087 Dimmer speed 2
088<=>095 Dimmer speed 3 (slowest)
096 <=>255 Reserved for future use

10Ch

Channel Function Value Percent/Setting
1 Dimmer 000<=>255 0-100%
2 Dimmer Fine 000 <=>255 0-100%
3 Red 000 <=>255 0-100%
4 Green 000 <=>255 0-100%
5 Blue 000<=> 255 0-100%
6 Amber 000 <=>255 0-100%
7 Lime 000 <=>255 0-100%
8 Strobe 000 <=> 010

011 <=>255

No function

Strobe, slow to fast

9 Virtual Color Wheel 000 <=> 255 Refer to the Virtual Color Wheel Chart section for specific values
10 Color Temperature 000 <=> 255 Refer to the Color Temperature Chart section for specific values

7Ch

Channel Function Value Percent/Setting
‘I Dimmer 000 a> 255 0-100%
2 Red 000 <=> 255 0-100%
3 Green 000 <=> 255 0-100%
4 Blue 000 <=> 255 0-100%
5 Amber 000 <=> 255 0-100%
6 Lime 000 <=> 255 0-100%
7 Strobe 000

011

<=> 010255 No function

Strobe, slow to fast

5Ch

Channel Function Value Percent/Setting
1 Red 000 <=> 255 0-100%
2 Green 000 <=>255 0-100%
3 Blue 000 <=> 255 0-100%
4 Amber 000 <=>255 0-100%
5 Lime 000 <=>255 0-100%

3Ch

Channel Function Value Percent/Setting
1 Dimmer 000 <=> 255 0-100%
2 Virtual Color Wheel 000 <=> 255 Refer to the Virtual Color Wheel Chart section for specific values
3 Color Temperature 000 <=> 255 Refer to the Color Temperature Chart section for specific values

1Ch

Channel Function Value Percent/Setting
1 Dimmer 000 <=>255 0-100% (color set through menu)

Contact UsGeneral Information

Chauvet World HeadquartersAddress: 5200 NW 108th Ave.Sunrise, FL 33351Voice: (954) 577-4455Fax: (954) 929-5560Toll-Free: (800) 762-1084Technical SupportVoice: (844) 393-7575Fax: (954) 756-8015Email: chauvetcsachauvetliahting.comWebsite: www.chauvetprofessional

Visit the applicable website above to verify our contact information and instructions to request support. Outside the US, UK, Ireland, Benelux, France, Germany, or Mexico, contact the dealer of record.

UL 1573CSA C22.2E113093