CLIPSAL LED Floodlight Instructions

CLIPSAL LED Floodlight Instructions

 

 

Product Range

TPFLS10LED 10 W LED Floodlight, 240 V a.c., 4000 K, IP65
TPFLS20LED 20 W LED Floodlight, 240 V a.c., 4000 K, IP65
TPFLS50LED 50 W LED Floodlight, 240 V a.c., 4000 K, IP65
TPFLS100LED 100 W LED Floodlight, 240 V a.c., 4000 K, IP65
TPFLS20SENLED 20 W LED Floodlight, 240 V a.c., 4000 K, IP44 – with PIR sensor

Installation Requirements

DANGERRISK OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH

  • This product must only be installed and serviced by appropriately qualified and/or licenced electrical personnel
  • Isolate the electrical supply before doing any work on this product.
  • Ensure that the product has been correctly installed and tested for safe operation before reconnecting the electrical supply

Failure to follow these instructions will result in death or serious injury.

CAUTION

RISK OF BURN INJURIES

During and after use, the product may be hot. Do not touch the product until it has completely cooled down

Failure to follow these instructions can result in minor injuries or equipment damage.

  • The product is Class 1.
  • Check whether the product has been damaged during transport. Do not operate/install any product which appears damaged in any way.Return the complete product to the place of purchase for inspection, repair or replacement.
  • Take care not to pull any electrical wires during unpacking as this may damage the connections.
  • Isolate the electrical supply before commencing any work on this equipment.
  • Select a suitable location for installation

Installation Instructions

  1. Remove all packaging material from the product.
  2. Use mounting bracket to mark hole centres for fixing.
  3. Secure mounting bracket using appropriate fasteners.
  4. Safely terminate wiring, paying particular attention to all markings. Mounting Options ­ TPFLS Series (no sensor)

Mounting Options ­ TPFLS20SENLED (with PIR Sensor)

Mounting Options – TPFLS20SENLED (with PIR Sensor)

Sensor Adjustment Procedure (TPFLS20SENLED only)

When the power is on, the unit will be able to detect movement within the adjustable sensor range. There are 3 adjustment settings on the back of the sensor unit for Light Level Adjustment (LUX), Timer Setting (TIME), and Sensitivity Level (SENS).

Sensitivity Level (SENS)Determines the detection area by increasing or decreasing the sensor range.

Timer Setting (TIME)This setting varies the time span that the floodlight will remain ON after it is triggered.

Light Level Adjustment (LUX)Unit can be adjusted so that the sensor only operates at or below the set ambient light level.

Commissioning Procedure (TPFLS20SENLED only)

Note: When setting the TIME, LUX or SENS adjustments keep clear of the field of view when assessing the effect of the adjustment.

  1. Connect unit to mains power and allow at least 30 seconds for the unit to stabilise before making any adjustments.
  2. Set the TIME adjustment fully anti-clockwise (10 second timer).
  3. Set the LUX adjustment to respond to light or dark conditions during commissioning.
  4. Set SENS adjustment fully clockwise (maximum range set).
  5. Aim the sensor head towards the desired field of view.
  6. Walk slowly around the desired field of view to confirm if floodlight is activated from within the desired area.
  7. Set SENS as desired for required range.
  8. Set LUX as desired for activation at dusk.
  9. Set TIME interval to desired time. For optimum performance, please ensure the floodlight mounting height is between 2-3m.

Note: When resetting the LUX level, allow 30 seconds for the sensor to stabilise to normal operation.

DimmingThe product series is not dimmable.

 Troubleshooting

Problem Possible Cause Possible Resolution
Light turns on for no apparent reason n Momentary power failure None, unit will reset after a time-out
Unseen target None, unit will reset after a time-out
Extreme draughts of hot or cold None, unit will reset after a time-out
Tree branches or bushes moved by wind
Vehicle or pedestrian traffic on edge of field of view
Light turns on for no apparent reason Wrong setting on LUX Reset according to Commissioning Procedure
Light does not turn on in dim or dark conditions Wrong setting on LUX Reset according to Commissioning Procedure

 

Problem Possible Cause

Possible Resolution

Light remains permanently on Moving source being detected. Remove unwanted source. If unable to resolve, reposition the sensor head (horizontally and vertically). The light should turn off after a time out. If the light remains on, call the Installer.

Note: Do not mount too close to air conditioner vents, flues, water fountains, sprinklers or pet doors.

Product Specification

Parameter TPFLS10LED TPFLS20LED TPFLS50LED TPFLS100LED TPFLS20SENLED
VoltageRating IP65 IP44
Total Power Consumption 10 W 20 W 50 W 100 W 20 W
Beam Angle                                              100°
Lumen Output 900 lm 1800 lm 4500 lm 9000 lm 1800 lm
Operating Temperature                                                –10 °C to +40 °C
Operating Humidity                                                  +10 to +95% RH, non-condensing
Storage Temperature +10 to +95% RH, non-condensing

Note: TPFLS20SENLED Floodlight does not have a sensor override function.

Warranty

For warranty information contact https://www.schneider-electric.com.au/en/about-us/legal/terms-and-conditions.jsp

Australia

Schneider Electric (Australia) Pty LtdCustomer Care Australia: 1300 369 233Email: [email protected]www.schneider-electric.com.auF2837/01

New ZealandSchneider Electric (NZ) LtdCustomer Care NZ: 0800 652 999 After hours (NZ Only): 0800 735 4357Email: [email protected]www.schneider-electric.com

References

[xyz-ips snippet=”download-snippet”]