COSMO QB90 Series Range Hood User Manual

QB90 Series Range Hood

Under Cabinet Range Hood¤¨¤ªRange Hood QB seriesInstallation Guide & Users ManualIMPORTANT: Read and save these instructions. NOTICE: Installer: Leave this guide with the homeowner Homeowner: Keep this guide for future reference

This product is designed for indoor residential use only.

INSTALLATION Tools Needed ………………………..3 Parts Supplied ……………………….4 Venting Requirements …………………5 Mount Heights & Clearance ………5-6 Calculating Vent System Length …..6 Venting Methods ………………………..7 Electrical Requirements ……………….8 Preparation …………………………………9 Installation …………………………..10-11 Range Hood Operations ……………..12

USE & CARE Troubleshooting …………………………….13 Use & Care Information …………………14 Measurements & Diagrams ………..15-20MAINTENANCE Cleaning ……………………………………….21 Replacing the Filter ……………………….21 Replacing the Light Bulb ………………..21WARRANTY & SERVICE Warranty ………………………………………22 Contact Us ……………………………………23

Venting Requirements· Vent system must terminate to the outside (roof or side wall).· DO NOT terminate the vent system in an attic or other enclosed area.· DO NOT use 4″ (10.2 cm) laundry-type wall caps.· Use metal/aluminum vent only. Rigid metal/ aluminum vent is recommended.· DO NOT use plastic vent. · Always keep the duct clean to ensure properairflow. · Calculate the following figures before instal-lation: 1. Distance from the floor to the ceiling. 2. Distance between the floor to the coun-tertop/stove (recommend* 27″ to 30″). 3. Distance between the countertop/stoveto the range hood. 4. Height of hood and duct cover.For the most efficient & quiet operation: · A distance of 27″ to 30″ is recommended*between stove top and the bottom of range hood. · It is recommended that the range hood be vented vertically through the roof through 8″ (17.8 cm) or bigger round metal/aluminum vent work. · The size of the vent should be uniform. · Use no more than three 90° elbows. · Make sure there is a minimum of 24″ (61 cm) of straight vent between the elbows if more than one elbow is used. · DO NOT install two elbows together. · The length of vent system and number of elbows should be kept to a minimum to provide efficient performance. · The vent system must have a damper. If roof or wall cap has a damper, DO NOT use damper (if supplied) on top of the range hood. · Use silver tape or duct tape to seal all joints in the vent system. · Use caulking to seal exterior wall or roof opening around the cap.

Height & Clearance

Cabinet Height

Cabinet or Singlepiece Chimney (Optional)

Range Hood HeightMin: 27″ Max: 30″ Ceiling Height

Under Cabinet Range hood

Countertop/Stove

36″ CounterTop

IMPORTANT: · A minimum of 8″ round (standard for this range hood) or 3-1/4 x 10″ rectangular duct (purchased separate-ly) must be used to maintain maximum airflow efficiency. · Always use rigid type metal/aluminum ducts if available to maximize airflow when connecting to providedduct. · Please use Duct Run Calculation below to compute total available duct run when using elbows, transitionsand caps. · ALWAYS, when possible, reduce the number or transitions and turns. If long duct run is required, increaseduct size from 8″ to 9″ or 10″. If a reducer is used, install a long reducer instead of a pancake reducer. Reducing duct size will restrict airflow and decrease airflow, thus reduce duct size as far away from opening as possible. · If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible. · Minimum mount height between stove top to hood bottom should be no less than 27-inch*. · Maximum mount height between stove top to hood bottom should be no higher than 30-inch*. · It is important to install the hood at the proper mounting height. Hoods mounted too low could result in heat damage and fire hazard; while hoods mounted too high will be hard to reach and will loose its performance and efficiency. · If available, also refer to stove top manufacturer’s height clearance requirements and recommended hood mounting height above range.* Due to different ceiling height configurations, recommended height may not be applicable.Minimum Duct Size: · Round – 8″ minimum · Rectangular – 3-1/4 x 10″ minimum (requires a 8″ to 3-1/4×10″ adaptor, not supplied)

Calculating Vent System Length

To calculate the length of the system you need, deduct the equivalent feet for each vent piece used in the system from the recommended maximum duct run.

Duct Run Calculation:

Recommended maximum run Duct Run Calcuation example:

8″ or 3-1/4 x 10″ duct

50 ft One roof cap, two 90º elbow, and one 45º elbow used:

Vent piece deduction

Each 90º elbow used

9 ft

Each 45º elbow used

5 ft

Each 8″ to 3/14 x 10″ transition used

7 ft

Side wall cap with damper

0 ft

Roof cap

0 ft

0ft + 9ft + 9ft + 5ft = 23ft used.Deduct 23ft from 50ft, 27ft maximum available for straight duct run.

8

Page 21

Use and Care Information :

Operations: Read and understand all instructions and warnings in this manual before operating the appliance. Save these instructions for future reference. Always leave safety grills and lters in place. Without these components, operating blowers could catch on to hair, ngers and loose clothing. NEVER dispose cigarette ashes, ignitable substances, or any foreign objects into blowers. NEVER leave cooking unattended. When frying, oil in the pan can easily overheat and catch re. The risk of self combustion is higher when the oil has been used several times. NEVER cook on “open” ames under the range hood. Check deep-fryers during use: Superheated oil may be ammable.Cleaning: The saturation of greasy residue in the blower and lters may cause increased in ammability. Keep unit clean and free of grease and residue build-up at all times to prevent possible res. Filters must be cleaned periodically and free from accumulation of cooking residue (see Cleaning Instructions on Page 22). Old and worn lters must be replaced immediately. DO NOT operate blowers when lters are removed. Never disassemble parts to clean without proper instructions. Disassembly is recommended to be performed by quali ed personnel only. Read and understand all instructions and warnings in this manual before proceeding.

Specifications :

Body Design Power Rating General Input Power Motor Input PowerAmpere Levels Of Speed ControlNumber Of Motors Motor Type Fan Type Control TypeFiltration Type Illumination Venting Size Interference Protection

Speci cations : Seamless Stainless Steel, Satin Finish 120V / 60Hz (USA & Canada standard) 264~266 W (260W + 2/3 x 2 W) 260 W (130W + 130W) 3 A 4 Levels 2 Motors Single Chamber Ultra Quiet Centrifugal Squirrel Cage Electronic Control Panel Stainless Steel Baf e Filter 2/3 x 2 W LED Top, 8 inches Round Radio Frequency Interference Protected

Measurements and Diagrams : All measurements in parenthesis are in millimeters. All inch measurements are converted from millimeters, thus inch measurements are estimated.7-3/4″ (197mm)7-3/4″ (197mm)

ScrubReplacing Filters: · Replace filters if they wear out due to age and prolonged use. Replacing the light bulb:1 Remove baffle filter as per installation. 2 Make sure the hood is disconnected or close the circuit breaker. Reach into the range hood and disconnect power clip. 3 Reach into interior of range hood until touching both lateral clips located on the side of the puck light. Gently squeeze and push down until puck pops out from its location.4 To reinstall new puck light, follow step 3 in reverse order.

WARRANTY AND SERVICEFor full warranty details on this product please visit: http://www.cosmoappliances.com/warranty TO RECEIVE WARRANTY SERVICE, YOURPRODUCT MUST BE REGISTERED. TO REGISTER, VISIT: WWW.COSMOAPPLIANCES.COM/WARRANTYSCAN TO REGISTER

IMPORTANTDo Not Return This Product To The Store If you have a problem with this product, please contactCosmo Customer Support at +1(888)784-3108DATED PROOF OF PURCHASE, MODEL #, AND SERIAL # REQUIRED FOR WARRANTY SERVICEIMPORTANTNe pas Réexpédier ce Produit au Magasin Pour tout problème concernant ce produit, veuillez contacter le service des consommateurs Cosmo Customer Support au+1(888) 784-3108 UNE PREUVE D’ACHAT DATEE EST REQUISE POUR BENEFICIER DELA GARANTIE.IMPORTANTENo regrese este producto a la tienda Si tiene algún problema con este producto, por favor contacte elAYUDA AL CLIENTE COSMO al +1(888)784-3108(Válido solo en E.U.A). NECESITA UNA PRUEBA DE DE COMPRA FECHADA, NÚMERO DEMODELO Y DE SERIE PARA EL SERVICIO DE LA GARANTÍACorrect Disposal of this product:This marking indicates that this appliance should not be disposed with other household wastes. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources.

NOTE:

report this ad

Cosmo is constantly making efforts to improve the quality and performance of our products, so we may make changes to our appliances without updating this manual.Electronic version of this manual is available at: www.cosmoappliances.com

[xyz-ips snippet=”download-snippet”]


Posted

in

by