Dell EMC PowerSwitch N3200-ON SeriesWarnings and Specifications
© 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
N3200-ON Series Warnings and Specifications
This document lists Warnings, Regulatory information, and Specifications for the Dell EMC PowerSwitch N3200-ON Series switch.Table 1. Document revision history
Revision | Date | Description |
A00 | 2020-03 | Initial release. |
Support and documentation
• For installation instructions, see the Dell EMC PowerSwitch N3200-ON Series Installation Guide at www.dell.com/support/.• To access the support site, go to www.dell.com/support/. To display information in your language, at the bottom of the page, select your country from the drop-down menu.
Information icon definitions:
WARNING: The Warning icon signals information about hardware handling that could result in injury.
Warnings
Cautions
Notes
Table 2. N3208PX-ON and N3224T-ON
Marketing model name | N3208PX-ON | N3224T-ON |
Regulatory Model # (RMN) | E30W | E31W |
Regulatory type # (RTN) | E30W001 | E31W002 |
BASE-T RJ45 | x 4(1G) 802.3bt Type-4 (90 W) PoEx 4(5G) 802.3bt Type-4 (90 W) PoE | x 24(1G) |
10G SFP+ | x 2 | x 4 |
25G SFP28 | — | — |
Stacking | — | x 2 QSFP28 (100G per port) |
AC or (optional) DC PSU* | One fixed AC PSU | 1 default AC PSU and second optional ACPSU (or) 2 optional DC PSUs |
(Optional) External power adapter | x 2 | — |
(EPA) | — | — |
(Optional) External power supply (EPS) | — | — |
Fans | x 1 | x 3 |
Sizein (H x W X D)mm (H x W x D)Size excludes the PSU and fan tray handle | 1.71 x 11 x 12.2843.5 x 279.4 x 312 | 1.71 x 17.09 x 15.7543.5 x 434 x 400(PSU handle adds 1.18 in or 30 mm) |
Weight** | 8.44 lbs/3.83 kg—240 W | 13.75 lbs/6.24 kg1 PSU:1.75 lbs/0.79 kg—550 W |
*Maximum number of PSUs available for the switch.**Chassis weight with one PSU.
Table 3. N3224F-ON, N3224PX-ON, and N3224P-ON
Marketing model name | N3224F-ON | N3224P-ON | N3224PX-ON |
Regulatory Model # (RMN) | E31W | E32W | E32W |
Regulatory type # (RTN) | E31W003 | E32W002 | E32W001 |
BASE-T RJ45 | — | x 24(1G) 802.3at PoE | x 24(1G/2.5G/5G/10G) 802.3btType-4 (90 W) PoE |
1G SFP | x 24 | — | — |
10G SFP+ | x 4 | x 4 | — |
25G SFP28 | — | — | x 4 |
Stacking | x 2 QSFP28 (100G per port) | x 2 QSFP28 (100G per port) | x 2 QSFP28 (100G per port) |
AC or (optional) DC PSU* | 1 default AC PSU and secondoptional AC PSU (or) 2optional DC PSUs | 1 default AC PSU and second optionalAC PSU (or) 2 optional DC PSUs | 1 default AC PSU and secondoptional AC PSU (or) 2optional DC PSUs |
(Optional) External power adapter (EPA) | — | — | — |
(Optional) External power supply (EPS) | — | — | x 1 |
Fans | x 3 | x 3 | x 3 |
Size in (H x W X D)mm (H x W x D)Size excludes the PSU and fan tray handle | 1.71 x 17.09 x 15.7543.5 x 434 x 400(PSU and fan tray handle adds 1.18 in or 30 mm) | 1.71 x 17.09 x 15.7543.5 x 434 x 400(PSU and fan tray handle adds 1.18 in or30 mm) | 1.71 x 17.09 x 15.7543.5 x 434 x 400(PSU and fan tray handle adds 1.18 in or 30 mm) |
Weight** | 14.25 lbs/6.46 kg1 PSU:1.75 lbs/0.79 kg | 15.6 lbs/7.08 kg1 PSU:2.0 lbs/0.90 kg—1050 W | 16.0 lbs/7.26 kg1 PSU:2.0 lbs/0.90 kg—1600 W |
*Maximum number of PSUs available for the switch.**Chassis weight with one PSU.
Table 4. N3248X-ON, N3248TE-ON, N3248P-ON, and N3248PXE-ON
Marketing model name |
N3248TE-ON | N3248P-ON | N3248X-ON |
N3248PXE-ON |
Regulatory Model # (RMN) | E31W | E32W | E31W | E32W |
Regulatory type # (RTN) | E31W005 | E32W003 | E31W004 | E32W004 |
BASE-T RJ45 | x 48(1G) | x 48(1G) 802.3at (30 W) PoE | x 48 (1G/2.5G/5G/1OG) | x 48(1G/2.5G/5G/10G) 802.3bt Type-4 (90 W) PoE |
10G SFP+ | — | x 4 | — | — |
25G SFP28 | — | x4 | x4 | |
10G SFP28 | x4 | — | — | — |
Stacking | x 2 QSFP28 (100G per port) | x 2 QSFP28 (100G per port) | x 2 QSFP28 (100G per port) | x 2 QSFP28 (100G per port) |
AC or (optional)DC PSU | 1 default AC PSU and second optional AC PSU (or) 2 optional DC PSUs | 1 default AC PSU and second optional AC PSU (or) 2 optional DC PSUs | 1 default AC PSU and second optional AC PSU (or) 2 optional DC PSUs | 1 default AC PSU and second optional AC PSU (or) 2 optional DC PSUs |
(Optional) External power adapter (EPA) | — | — | — | — |
(Optional) External power supply (EPS) | — | x 1 | — | x 1 |
Fans | x3 | x3 | x3 | x3 |
Size in (H x W X D) mm(HxWxD)Size excludes the PSU and fan tray handle | 1.71 x 17.09 x 15.75 43.5 x 434 x 400 (PSU and fan trayhandle adds 1.18 in or 30 mm) | 1.71 x 17.09 x 15.75 43.5 x 434 x 400(PSU and fan tray handle adds 1.18 in or 30 mm) | 1.71 x 17.09 x 15.75 43.5 x 434 x 400(PSU and fan tray handle adds 1.18 in or 30 mm) | 1.71 x 17.09 x 15.75 43.5 x 434 x 400(PSU and fan tray handle adds 1.18 in or 30 mm) |
Weight** | 15.4 lbs/6.99 kg1 PSU:1.75 lbs/0.79 kg—550 W | 16.7 lbs/7.57 kg1 PSU:2.0 lbs/0.90 kg—1050 W | 16.1/7.30 kg1 PSU:1.75 lbs/0.79 kg—550 W | 17.6 lbs/7.98 kg1 PSU:2.0 lbs/0.90 kg—1600 W |
*Maximum number of PSUs available for the switch.**Chassis weight with one PSU.
Mexico-only NOM information
The following information is in compliance with the requirements of the official Mexican standards (NOM):
Table 5. NOM
Description | Details |
Exporter | Dell Inc.One Dell Way, Round Rock, TX 78682 |
Importer | Dell México, S.A. de C.V.Av. Javier Barros Sierra, no 540, Piso 10, Col. Lomas de Santa FeDelegación Álvaro Obregón, Ciudad de México. C.P. 01219R.F.C: DME9204099R6 |
Ship to | Dell México, S.A. de C.V.Av. Javier Barros Sierra, no 540, Piso 10, Col. Lomas de Santa FeDelegación Álvaro Obregón, Ciudad de México. C.P. 01219R.F.C: DME9204099R6 |
Supply voltage | 100V–240 VAC |
Frequency | 50–60 Hz |
Maximum steady state current consumption | See the Power consumption parameters table listed below. |
N3200-ON Series Specifications
Table 6. Environmental parameters
Parameter | Specifications |
Operating temperature | 0° to 45°C (32°F to 113°F) continuously |
Operating humidity | 5% to 95% (RH), noncondensing |
Storage temperature | –40°C to 70°C (–40°F to 149°F ) |
Storage humidity | 5% to 95%, noncondensing |
Maximum thermal output without PoE | • N3208PX-ON: 49.48 W = 168.83 BTU/Hr• N3224T-ON: 95.58 W = 326.13 BTU/Hr• N3224F-ON: 122.08 W = 416.55 BTU/Hr• N3224P-ON: 100.74 W = 343.74 BTU/Hr• N3224PX-ON: 173.01 W = 590.33 BTU/Hr• N3248TE-ON: 102.3 W = 349.06 BTU/Hr• N3248X-ON: 300.06 W = 1023.85 BTU/Hr• N3248P-ON: 112.26 W = 383.05 BTU/Hr• N3248PXE-ON: 325.72 W = 1111.40 BTU/Hr |
Maximum operational altitude | 10,000 ft (3,048 m) |
Maximum non-operational altitude | 39,370 ft (12,000 meters) |
Shock | Dell EMC Spec SV0115 |
Table 7. Power consumption parameters
Parameter | Specifications |
Input voltage | AC: 100 to 240 VAC 50/60 HzDC: –40 VDC to –60 VDC |
Input current without PoE | • N3208PX-ON: 1.12 Amps @ 110 VAC and 0.56 Amps @ 220VAC• N3224T-ON: 2.08 Amps @ 110 VAC and 1.04 Amps @ 220 VAC• N3224F-ON: 2.32 Amps @ 110 VAC and 1.16 Amps @ 220 VAC• N3224P-ON: 2.26 Amps @ 110 VAC and 1.13 Amps @ 220 VAC• N3224PX-ON: 3.44 Amps @ 110 VAC and 1.72 Amps @ 220VAC• N3248TE-ON: 2.22 AMps @ 110 VAC and 1.11 Amps @ 220VAC• N3248P-ON: 2.4 Amps @ 110 VAC and 1.2 Amps @ 220 VAC• N3248X-ON: 4.9 Amps @ 110 VAC and 2.5 Amps @ 220 VAC• N3248PXE-ON: 5.44 Amps @ 110 VAC and 1.72 Amps @ 220VAC |
PSU configuration | Main PSU |
Maximum steady current consumption | |
Total PoE budget |
• N3208PX-ON: 720 W• N3224P-ON: 720 W• N3224PX-ON: 2160 W• N3248P-ON: 1440 W• N3248PXE-ON: 4320 W |
PoE output per port | • N3208PX-ON: 4x1000GBase-T Ports with 4 ports of 802.3btType-4 (90 W) PoE and 4x5GBase-T Ports with 4 ports of 802.3btType-4 (90 W) PoE• N3224P-ON: 24x1000Base-T Ports with 802.3at Type-2 (30 W) PoE• N3224PX-ON: 24x10GBase-T Ports with 802.3bt Type-4 (90 W) PoE• N3248P-ON: 48x1000Base-T Ports with 802.3at Type-2 (30 W) PoE• N3248PXE-ON: 48x10GBase-T MACSec Ports with 802.3bt Type-4 (90 W) PoE |
© 2020 Dell Inc. or its subsidiaries. All rights reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be trademarks of their respective owners.
References