Dimplex Revillusion Electric Fireplace & Fireplace Insert RBF24DLX / RBF24DLXWC User Manual

Owner’s ManualRevillusion™ Electric Fireplace/Fireplace InsertModel RBF24DLX (6909990100)Model RBF24DLXWC (6909990200)

IMPORTANT SAFETY INFORMATION: Read this manual first before attempting to install or use the Revillusion™ Electric Fireplace. Always comply with the warnings and safety instructions contained in this manual to prevent personal injury or property damage.To view the full line of Dimplex products, visit www.dimplex.com

SAVE THESE INSTRUCTIONS

Conventions Used in this manual:

! NOTE: Procedures and techniques considered important enough to emphasize. CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment.WARNING: Procedures, precautions, and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death

Welcome

Thank you for purchasing a Revillusion™ Electric Fireplace by Dimplex. Please use our convenient online registration page to record your model and serial numbers for future reference at: www.dimplex.com/register

CAUTION: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible electric shock or fire hazard and will void the warranty.

NO NEED TO RETURN TO THE STORE

Questions with operation or assembly? Require Parts Information?Product Under Manufacturer’s Warranty?Contact us at: www.dimplex.com/customer_supportFor Troubleshooting and Technical SupportOR Toll-Free 1-888-346-7359Monday to Friday 8:00 a.m. to 4:30 p.m. ESTIn order to better serve you, please have your model and serial numbers ready or register your product online before calling (see above).

IMPORTANT INSTRUCTIONS

Basic Precautions

When using any electrical appliance, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons. These precautions include:

① Read all instructions before using the Revillusion TM Electric Fireplace.

DANGER: High temperatures may be generated under certain abnormal conditions. Do not partially or fully cover or obstruct the front of the fireplace.

② This fireplace is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. The trim around the heater outlet becomes hot during heater operation. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9 m) from the front of the fireplace.③ Extreme caution is necessary when the fireplace is used by or near children or invalids and whenever the fireplace is left operating and unattended.④ Always turn off the fireplace when it is not in use.⑤ Do not operate the fireplace after it malfunctions, has been dropped, or damaged in any manner. Disconnect power at the service panel and have the fireplace inspected by a reputable electrician before using.⑥ Do not use this fireplace outdoors.⑦ Never locate the fireplace where it may fall into a bathtub or other water container.⑧ Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, or fire, or damage the fireplace.⑨ To prevent a possible fire, do not block air intakes or exhaust in any manner⑩ To disconnect the heater, turn the controls to OFF and turn off the power to the heater circuit at the main disconnect panel.⑪ All electrical heaters have hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.⑫ Do not modify this fireplace. Use it only as described in this manual. Any other use may cause fire, electric shock, or injury to persons.⑬ Do not burn wood or other materials in this fireplace.⑭ Disconnect all power coming to the fireplace at the main service panel before performing any cleaning or maintenance.⑮ When transporting or storing the fireplace, keep it in a dry place, free from excessive vibration, and store to avoid damage.! NOTE: Changes or modifications not expressly approved by the party responsible for compliance could void user’s authority to operate the equipment.

Special PrecautionsWARNING: Remote control contains a small battery. Keep away from children. If swallowed, seek medical attention immediately.WARNING: Do not install battery backward, charge, put in fire, or mix with used or other battery types as it may explode or leak causing injury.WARNING: Do not open the unit. There is a risk of electric shock. There are no user-serviceable parts inside.CAUTION: Always use a qualified technician or service agency to repair the electric fireplace. FCC ComplianceCAUTION: This unit has been tested and found to comply with the limits for Class B digital devices, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This unit generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception, which can be determined by turning the unit OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the unit and the receiver.• Connect the unit into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.

This unit complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This unit may not cause harmful interference, and (2) this unit must accept any interference received, including interference that may cause undesired operation.

FCC CAUTION: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

Specifications

The Revillusion™ Electric Fireplace offers an alternative to a wood or gas fireplace. It can give your existing fireplace new life or transform a cabinet or media center of your own into a stunning focal point.

Electrical

Dimensions

Operation Temperature-4o to 104oF (-20oto 40oC)

WARNING: Electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electric shock, or injury to persons.

! NOTE: A 15 Amp circuit is required. A dedicated circuit is preferred, but not essential in all cases. A dedicated circuit will be required if, after installation, the circuit breaker trips or the fuse blows on a regular basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of the circuit breaker.

Unpacking the UnitThe unit comes packed with a protective sheet covering the front of the unit. This sheet is intended to prevent dust and debris from entering during construction. This sheet is designed so that it can be partially removed to complete the wiring and unpacking and can be reinstalled until the final installation is complete.

The log set was installed on the grate and the grate permanently fixed to the fireplace at the factory.Carefully remove the packaging from around the log set. Make sure the wires from the log set are connected securely to the grate box.

CAUTION: The Realogs® contain LEDs to create a unique pulse and glow effect. Handle the log set carefully. They are fragile and can crack or break if dropped.

Installation

Framing1. The RevillusionTM Electric Fireplace/ Fireplace Insert does not require any special venting.2. To build the rough-in opening, follow the framing dimensions below.

! NOTE: The materials used for the finished surround must be cut to precise dimensions (dimensions B & C) as the 1/4″ (0.6 cm) self trimming flange is only to create a finished appearance.

Front Glass Installation Method

1. Before installing the front glass installation, remove the hole caps from the fireplace.2. Make sure all hardware has been included in package prior to starting.3. Install hardware items A and B onto front glass.4. Install brackets onto fireplace with screws C.

5. Place front glass into fireplace and secure with screw D

6. Install top trip piece.

PlacementThis fireplace is a zero clearance design, with the exception of the top of the unit, where any insulation and vapor barrier should be placed a minimum of 2” (5.1 cm) from the fireplace.DANGER !: High temperatures may be generated under certain abnormal conditions. Do not partially or fully cover or obstruct the front of the fireplace.WARNING: All electrical heaters have hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.WARNING: The electric fireplace must NOT be in direct contact with any building vapor barrier or insulation.! NOTE: If the fireplace is going into an existing opening and used with the trim accessory, locate the fireplace as needed for the best appearance.1. Place the fireplace into the opening. Level with shims if necessary.2. From the inside of the unit, gently remove the interior brick panels (attached magnetically).3. Screw the mounting flanges directly to the stud opening or bend the flanges out to 90° to be flush with the surrounding studs and screwed to the studs using suitable hardware.

Bathroom InstallationThis electric fireplace must be protected by a GFI circuit when installed in an area where water is present. If the unit is installed using a receptacle, it must be readily accessible.This fireplace is not watertight and must be installed as to prevent water from entering the unit. Install the unit away from showers, tubs, etc. Keep towels and other combustible materials 3 feet (0.9 m) away from the front of the unit.

Electrical

GeneralThe fireplace is packaged with a three (3) prong plug installed for plug-in convenience. Hard wiring the fireplace is also an option for installation.WARNING: Construction and electrical outlet wiring must comply with local building codes and other applicable regulations to reduce the risk of fire, electrical shock, or injury to persons.

WARNING: Do not attempt to wire your own new outlets or circuits. To reduce the risk of fire, electric shock or injury to persons, always use a licensed electrician.

Grounding Instructions

This product must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

DANGER! Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

Permanent Heat DisableThe fireplace heater can be permanently disabled by removing the electronic jumper on the main control board. Disable the heater before any additional installation takes place.To permanently disable the heater:1. Locate and remove the panel on the top left of the unit.2. Pull out the electronic jumper (shunt), on the on the left side of the screw in the right corner of the board. The label beside the jumper is “HT EN”.3. Reinstall the previously removed panel.

Power Cord

WARNING: Install the power cord so that it is stored or secured to avoid tripping or snagging and to reduce the risk of fire, electric shock, or injury to persons.WARNING: This fireplace is for use on a 120V circuit and has a grounding plug that looks like the plug in Figure 1. Make sure the plug is connected to an outlet having the same configuration as the plug. No adapter should be used with this product.

WARNING: Do not use this fireplace with an extension cord. Plug the cord directly into an ap appropriate wall receptacle.

Removing Power Cord for Hardwire Installation

To remove the power cord:1. Locate the power cord on the back of the fireplace. Remove 2 screws and slide the electrical box back.

2. Unscrew the 2 wire connectors.3. Cut the green (ground wire) leaving enough length to reuse the wire.4. Replace assembly with the hardwire cover (included).

Hard Wire Installation

WARNING: Make sure the circuit on which the fireplace is to be installed has the power cut off at the service panel until installation is complete.1. Allow 8″ (20.3 cm) of service cable for connecting power supply wire to junction box on the unit when installing and before finishing the wall. Allow up to 4 ft (122 cm) of service cable for connecting power supply wire to junction box when installing after finishing wall.2. Wire a dedicated, properly fused circuit with a 15 A rating.3. Feed the service cable through the electrical cover on the back of the unit and secure using a 1/2″ (1.3 cm) approved strain relief connector.4. Remove the outer jacket and strip the individual conductors 1/2″ (1.3 cm) from the end.5. Follow the following instructions for your specific installation.6. Wiring inspection can be done from the front of the unit: remove the access panel, to the right of the controls, to access the service cable and wires from the unit.

Direct Power Wiring (120 V)

All wiring must be completed prior to installing the electric fireplace.Use 2-conductor wires with ground (3 wires total) from the power supply (breaker panel) to the junction box on the electric fireplace.To install 120 V direct power wiring:1. Pull out the RED-N, BLACK, and GROUND-G wires.2. Connect N (white) and N (red) in the fireplace to the N (white) from the power supply.3. Connect L (black) wire from the fireplace to the L1 (black) from the power supply.4. Connect the G (green) ground wire from the fireplace to the ground from the power supply.5. Insert all the wiring back into the fireplace and secure with a cable clamp.6. Make sure all connections are tight.

Wall Switch (120 V)

! NOTE: Use a single pole, single throw (On/Off) wall switch that is rated for a minimum of 15 A.

Before installing the wall switch:• Connect a 2-conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box.• Connect a 2-conductor wire with ground (3 wires total) from the main switch wall box to the junction box on the fireplace.

To install a 120 V wall switch:1. Pull out the red, black, and green wires.2. Connect the red-N wire from the fireplace to the white-N from the power supply panel.3. Connect black-L from the fireplace to the line (black) from the main power wall switch using a wire connector.5. Connect the other end of L (black) to the L terminal of the main power wall switch.6. Connect G (green) from the electric fireplace to the G (green) ground wire of the main power wall switch by using a wire connector (not supplied).7. Secure the two remaining ground wires (green) with a ground screw in the main switch wall box.8. Insert all the wiring of the main power wall switch into the main switch wall box.9. Insert all the wiring back into the electric fireplace and secure with a cable clamp.10. Make sure all connections are tight.

Operation

General

WARNING: The RevillusionTM Electric Fireplace must be installed properly before it is used.CAUTION: Except for installation and cleaning described in this manual, an authorized service representative should perform any other servicing. This fireplace operates with ComfortSaver™ technology, which automatically adjusts the fan speed and heater wattage to safely and precisely match the requirements of the room based on the thermostat setting.The heater operates such that once the room reaches the set point, the fan and heater will continuously run at a low level to maintain the desired room emperature. If the temperature in the room rises significantly, (e.g., sun coming through a window or a central furnace turns on) the heater will turn off and periodically turn back on to circulate the air around the unit until the room temperature drops and requires the heater to be constantly on again.!NOTE: The fireplace retains heat after shutdown. When the heat is turned OFF, there is a 2-minute cooldown period before the fan shuts off completely.

Touch Panel and Remote Controls

The manual controls for the RevillusionTM Electric Fireplace are located on the front panel. Touch an icon to activate. The selected setting displays on the left side of the panel.A multi-function remote control is included. The remote control has a range of approximately 30 ft (9 m). To operate correctly, the remote control must be pointed toward the front of the electric fireplace.

Maintenance

Reset Temperature Cutoff SwitchShould the heater overheat, an automatic cut-out will turn the heater off and it will not come back on without being reset.If the fireplace is installed with a plug, it can be reset by unplugging the fireplace, waiting 5 minutes, and plugging back in.If the fireplace is hard-wired, it can be reset by turning off the electrical breaker, waiting 5 minutes, and turning the breaker back on.CAUTION: If you need to continuously reset the heater, unplug the unit and call technical support at 1-888346-7539.

General Maintenance

Inspect the electric fireplace regularly, depending upon conditions, and at a minimum yearly intervals. Remove dust and clean the logs, grate, and base as required.

WARNING: Disconnect power and allow the heater to cool before attempting any maintenance or cleaning to reduce the risk of fire, electric shock, or injury.CAUTION: Except for installation and cleaning described in this manual, an authorized service representative should perform any other servicing.

Clean Logs and BaseThe electric fireplace set should not be operated with an accumulation of dust or dirt on or in the fireplace, as this can cause a build up of heat and eventual damage.Dust and vacuum the fireplace as needed. Use a damp cloth and a mild detergent to clean the painted surfaces of the electric fireplace. Never use abrasive cleaners.

Clean Reflector Screen

The reflector screen is cleaned in the factory during the assembly operation. During shipment, installation, handling, etc., the screen may collect dust particles; these can be removed by dusting lightly with a clean dry cloth.To remove fingerprints or other marks, clean the reflector screen damp cloth. Never use abrasive cleaners. Dry the screen completely with a lint free cloth to prevent water spots.

Replace Remote Battery

To replace the battery:1. Push down on the battery cover located on the back of the remote control. Slide the battery cover open.2. Install 3V (CR2032) Lithium battery in the battery holder. The positive (+) side of the battery faces up.3. Close the battery cover.

The old battery must be recycled or disposed of properly. Check with your Local Authority or Retailer for recycling advice in your area.

CAUTION: When transporting or storing the heater and cord, keep in a dry place, free from excessive vibration and store so as to avoid damage.

Warranty

Two Year Limited WarrantyProducts to which this limited warranty appliesThis limited warranty applies to your newly purchased Dimplex RevillusionTM electric fireplace. This limited warranty applies only to purchases made in any  province of Canada except for Yukon Territory, Nunavut, or Northwest Territories or in any of the 50 States of the USA (and the District of Columbia) except for Hawaii and Alaska. This limited warranty applies to the original purchaser of the product only and is not transferable.

Products excluded from this limited warrantyThe fireplace is only covered for transportation to the end user and will not be covered if damage occurs during normal operation and/or maintenance. Products purchased in Yukon Territory, Nunavut, Northwest Territories, Hawaii, or Alaska are not covered by this limited warranty. Products purchased in these States, provinces, or territories are sold AS IS without warranty or condition of any kind (including, without limitation, any implied warranties or conditions of merchantability or fitness for a particular purpose) and the entire risk of as to the quality and performance of the products is with the purchaser, and in the event of a defect the purchaser assumes the entire cost of all necessary servicing or repair.

What this limited warranty covers and for how longProducts, other than fireplace surrounds (mantels) and trims, covered by this limited warranty have been tested and inspected prior to shipment. Subject to the provisions of this warranty, Glen Dimplex Americas warrants such products to be free from defects in material and workmanship for a period of 2 years from the date of the first purchase of such products as follows: (a) a repair or replacement warranty on defective products or parts, including in-home services, for the first year following the date of first purchase; and (b) thereafter, a replacement of parts warranty on defective products and parts (with no in-home services) for the 1 year period commencing on the first anniversary of first purchase and ending on the second anniversary of the date of first purchase.

Dimplex fireplace surrounds (mantels) and trims covered by this limited warranty have been tested and inspected prior to shipment and, subject to the provisions of this warranty, Glen Dimplex Americas warrants such products to be free from defects in material and workmanship for a period of 1 year from the date of first purchase of such products. Warranty services do not include in-home services.

The limited 2 year warranty period for products other than fireplace surrounds (mantels) and trims and the limited 1 year warranty period for fireplace surrounds (mantels) and trims also applies to any implied warranties that may exist under applicable law. Some jurisdictions do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to the purchaser.

What this limited warranty does not coverThis limited warranty does not apply to products that have been repaired (except by Glen Dimplex Americas or its authorized service representatives) or otherwise altered. This limited warranty does further not apply to defects resulting from misuse, abuse, accident, neglect, incorrect installation, improper maintenance or handling, or operation with an incorrect power source.

What you must do to get service under this limited warrantyDefects must be brought to the attention of Glen Dimplex Americas Technical Service by contacting Glen Dimplex Americas at 1-888-7539, or 1367 Industrial Road, Cambridge Ontario, Canada N3H 4W3. Please have proof of purchase, catalogue/model, and serial numbers available when calling. Limited warranty service requires a proof of purchase of the product.

What Glen Dimplex Americas will do in the event of a defectIn the event a product or part covered by this limited warranty is proven to be defective in material or workmanship during (i) the 2 year limited warranty period for products other than fireplace surrounds (mantels) and trims, and (ii) the 1 year limited warranty period for surrounds (mantels) and trims, you have the following rights:

  • Glen Dimplex Americas will in its sole discretion either repair or replace such defective product or part without charge. If Glen Dimplex Americas is unable  to repair or replace such product or part, or if repair or replacement is not commercially practicable or cannot be timely made, Glen Dimplex Americas may, in lieu of repair or replacement, choose to refund the purchase price for such product or part.
  • Limited warranty service will be performed solely by dealers or service agents of Glen Dimplex Americas authorized to provide limited warranty services.
  • For products (other than surrounds (mantels) and trims) for the period ending at midnight on the first anniversary of the date of first purchase, Glen Dimplex Americas will in its sole discretion either repair or replace such defective product or part without charge. If Glen Dimplex Americas is unable to repair or replace such product or part, or if repair or replacement is not commercially practicable or cannot be timely made, Glen Dimplex Americas may, in lieu of repair or replacement, choose to refund the purchase price for such product or part. This limited warranty entitles the purchaser to onsite or in-home warranty services. Accordingly, Glen Dimplex Americas will be responsible for all labor and transportation costs associated with the repair or replacement of the product or part except as follows: (i) charges may be levied for travel costs incurred to travel to the purchaser’s site where the product is located if the purchaser’s site is beyond 30  miles (48 km) from the closest service depot of Glen Dimplex Americas’ dealer or service agent; and (ii) the purchaser is solely responsible for providing clear access to all serviceable parts of the product.
  • For products (other than surrounds (mantels) and trims) for the period commencing at 12:01 a.m. on the day after the first anniversary of the first purchase and ending at midnight on the second anniversary of the date of first purchase, this limited warranty entitles the purchaser to replacement parts only without charge. If Glen Dimplex Americas is unable to replace such part, or if replacement is not commercially practicable or cannot be timely made, Glen Dimplex  Americas may, in lieu of replacement, choose to refund the purchase price for such part. The purchaser shall not be entitled to on-site or in-home warranty services. The purchaser shall be responsible for all expenses incurred for the removal of the part and installation of the replacement part including, without limitation, all shipping costs and transportation costs to and from the authorized dealer’s or service agent’s place of business and all labour costs. Such costs shall not be the responsibility of Glen Dimplex Americas.
  • For surrounds (mantels) and trims for the period ending at midnight on the first anniversary of the date of first purchase, Glen Dimplex Americas, will in its sole discretion, either repair or replace such defective surrounds (mantels) and trims or part thereof without charge. If Glen Dimplex Americas is unable to repair or replace such product or part, or if repair or replacement is not commercially practicable or cannot be timely made, Glen Dimplex Americas may, in lieu of repair or replacement, choose to refund the purchase price for such product or part. The purchaser shall not be entitled to on-site or in-house services. The purchaser is responsible for all expenses incurred for repair or replacement of such product or part including, without limitation, all shipping costs and transportation costs to and from the authorized dealer’s or service agent’s business and all labour costs. Such costs shall not be the responsibility of Glen Dimplex Americas.
  • On-site or in-home services not provided under this warranty may be performed at the purchaser’s specific request and expense at Glen Dimplex Americas’ then-current rates for such services.

What Glen Dimplex Americas and its dealers and service agents are also not responsible for:IN NO EVENT WILL GLEN DIMPLEX AMERICAS, OR ITS DIRECTORS, OFFICERS, OR AGENTS, BE LIABLE TO THE PURCHASER OR ANY  THIRD PARTY. WHETHER IN CONTRACT, IN TORT, OR ON ANY OTHER BASIS, FOR ANY INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY, CONSEQUENTIAL, OR INCIDENTAL LOSS, COST, OR DAMAGE ARISING OUT OF OR IN CONNECTION WITH THE SALE,  MAINTENANCE,  USE, OR INABILITY TO USE THE PRODUCT, EVEN IF GLEN DIMPLEX AMERICAS OR ITS DIRECTORS, OFFICERS, OR AGENTS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES, COSTS OR DAMAGES, OR IF SUCH LOSSES, COSTS, OR DAMAGES ARE FORESEEABLE. IN NO EVENT WILL GLEN DIMPLEX AMERICAS, OR ITS OFFICERS, DIRECTORS, OR AGENTS BE LIABLE FOR ANY DIRECT LOSSES, COSTS, OR DAMAGES THAT EXCEED THE PURCHASE PRICE OF THE PRODUCT. SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO THE PURCHASER. How State and Provincial law apply This limited warranty gives you specific legal rights, and you may also have other rights which vary from jurisdiction to jurisdiction. The provisions of the United Nations Convention on Contracts for the Sale of Goods shall not apply to this limited warranty or the sale of products covered by this limited warranty.

Technical Support

Technical and troubleshooting support, as well as a list of replacement parts can be found on: www.dimplex.com/customer_support.

1-888-346-7539 | www.dimplex.com

In keeping with our policy of continuous product improvements, we reserve the right to make changes without notice.© 2019 Glen Dimplex Americas

Dimplex Revillusion Electric Fireplace & Fireplace Insert RBF24DLX / RBF24DLXWC User Manual – Dimplex Revillusion Electric Fireplace & Fireplace Insert RBF24DLX / RBF24DLXWC User Manual –

[xyz-ips snippet=”download-snippet”]