Dr Trust Handy Nebulizer Piston Compressor 402 User Manual
Dr Trust
Handy Nebulizer Piston Compressor 402
QUICKSTARTUPGUIDE
Step1
Place the medicine in medicine chamber.
Step2
Attach the mask with the medicine chamber and main unit.
Step3
Connect the power wire to the socket and turn on the Air Compressor.
Step4
Attach the mouthpiece and start inhaling the medicine.
Step5
Once consumed the medicine, turn off the nebulizer.
OVERVIEW
Dr. Trust Handy Nebulizer is an AC-power air compressor system intended to provide a source of compressed air for medical purposes for home healthcare. It is to be used to produce aerosol particles of medication for respiratory therapy for both children and adults.
ABOUTU
Driven by the passion for innovation, we at Dr Trust endeavour to provide our customers with the latest medical inventions with an objective to promote good health and wellness all around the world. All the medical devices and health monitors provided by Dr Trust are supported by accurate, latest and ground breaking technologies, innovated at our headquarter in NY, USA. All our products adhere to the most stringent CEand FDA guidelines and are strongly recommended by doctors and health practitioners. Our products are designed in the utmost exemplary ways to ensurethattheir accuracy and convenience are unrivalled. The ease of their use and operation makes them even more suitable for users of all age groups.DrTruststrives to enhance the quality of lifestyle by providing with the most trusted and innovative health care and wellness products. Being a renowned global leader in health care products, Dr Trust ensures that our technically efficient team works dynamically and tirelessly to provide the best of the medical devices to our clients. The products that we have to offer are suitably designed for use at homes, laboratories and hospitals. Our ground breaking solutions allow you to monitor your health in the easiest ways possible. In today’s era when all of our lives are too hassled to handle, it becomes a bit difficult to pay attention to our health. But it has now become easier with the coming of the monitoring devices which can be conveniently used at homes and even on the go.We bring to you a variety of best self medical devices, trusted and used by Doctors, medical professionals and home users all over the world.
INTENDED
Your Nebulizer is intended for use in the treatment of asthma, COPD and other respiratory ailments in which an aerosolized medication is required during therapy. Please consult with your physician and/or pharmacist to determine if your prescription medication is approved for use with this Nebulizer
Disclaimer: The Nebulizer should be used as per the guidance of a licensed physician and/or a respiratory therapist. We encourage you read thoroughly this guidebook to learn about the features of this product. Any use of this product other than its intended use should always be avoided.
COMPONENTS
- Compressor housing 7. Angled mouthpiece
- Lid 8. Air tube
- Air vents 9. Adult mask
- ON/OFF switch 10. Pediatric mask
- Power cord 11. Air filter (5pcs)
- Air outlet
GENERAL INFORMA
The compressor Nebulizer system is for aerosol therapy. And it is supplied with the kit Nebulizer. The manufacturer cannot be held liable for any damage caused by improper, incorrect, or unreasonable use, or if the unit is connected to electrical installations not complying with safe regulations.
Caution
- Use the device only for its intended purpose as described.
- Do not operate the unit in the presence of any anesthetic, inflammable mixtures, or oxygen.
- Do not allow unsupervised children or physically challenged individuals to use the unit.
- Do not turn the unit OFF by simply pulling out the plug form electrical outlet.
- Correct operation of nebulizer is affected by electromagnetic interference. Make sure that device do not come in contact with another electric device during use, if so, remove it & plug it into different electrical outlet.
- In case of failure and/ or malfunction, do not open the compressor housing.
- Functioning of the device may be affected if original replacement parts are not used.
- When using any electrical appliance, certain important safety measures must always be observed, including the following: -Use only original accessories and components;-Never submerge the unit in water as the device is not protected against water penetration;-Never touch the unit when your hands are wet or moist;– Do not leave the unit outdoors;-Place the device on stable and horizontal surface during use;-Make sure the airventopenings area not obstructed;
- Make surethatthe electrical rating shown on the rating plate on the bottom of the unit corresponds to the main voltage and frequency before plugging in the device.
- Do not use any adapter simple or multiple, and/or extension cable.
- Unplugthe device from the electrical outlet when not in operation.
- Follow the manufacturer’s instructions for installing the device. The manufacturer cannot be held responsible for any damage caused by incorrect installation
- Contact customer care to replace power supply cord.
- The power supply cord should be completely unwound to prevent dangerous overheating.
- Before performing any cleaning operation or filter replacement, disconnect the device from the main supply by unplugging it orby turning the main supply switch OFF.
- Do not let child get hold of the small parts of the nebulizer astheycan be swallowed easily causing severe problem.
- Ensuretodisposeofthedevicewhen not in use.
- lfyou decide not to use the device, it is recommended to dispose of it according to the local regulations in force.
- Verifythat the medications prescribed by your doctor can be used with com man compressor nebulizer systems for aerosol therapy.
Note
-Use this device only with medications prescribed by your doctor.-Use the accessories recommended by your doctor for therapy.
How to Use
Before Using the Device Remove the compressor from carrying case before use. Examine the unit in order to check the compressor and accessories for visible damage or defectssuch as cracks in the plastic housing which could expose electrical components. Start Using the Device
- When start taking a treatment, sit upright and be relaxed.
- Put the prescribed quantity of medication into the medicine cup. Maximum fill volume is 8 ml.
- Close the nebulizer by holding the bottom and turning the top clockwise, making sure that the unit is thoroughly closed.
- Connect one end of the air tube to the nebulizer, and the other end to the air outlet on the device.
- Connect the angled mouthpiece to the nebulizer.
- If using the mask, remove the angled mouthpiece and connectthe mask directly to the nebulizer.
- Plug the compressor into the electrical outlet; make sure the electrical rating shown on the rating plate on the bottom of the unit corresponds to your main voltage.
- To start the treatment, switch the device on by pressing the ON/OFF switch onto the “I” position.
ATTENTION&
This device is rated for intermittent use of 30 minutes ON/30 minutes OFF.When the treatment has been completed, switch the unit OFF by setting the switch position to “O” and disconnect the plug from the electrical outlet.Do not use the device without the filter.
CLEANING AND MAINTENA
CLEAN I NG OF THE COMPRESSORUse a clean dry cloth and mild detergents to clean outside of the unit.
ATTENTION:During cleaning, make sure the internal parts of the unit are not in contact with liquids and the power cord is not connected.
CLEANING AND DISINFECTION OFTHEACCESSORIESAfter Each Treatment The nebulizer can be cleaned by washing in liquid soap and water and then disinfected by boiling in water (max.10 minutes) or in an autoclave (max.121oCfor 10 minutes). It is suggested that the mask and angled mouthpiece be disinfected using cold disinfecting liquids.Dry the nebulizer using a clean cloth. After drying, connect it to the air outlet and switch the compressor ON to verify that it is functioning after cleaning. & Do not boil or autoclave the angled mouthpiece, air tube or masks. &It is important to follow the cleaning instructions carefully to ensure optimal operation. Replacement of the filterThe filter is to be replaced after approximately 30 hours of use, or when it appears dirty. Open the filter holder to replace the filter with a new one. Use original filters only.
TROUBLESHG
The device does not turn on:
- Make sure the plug is firmly inserted into the electrical outlet.
- Make sure the device has been operating within operating limits as indicated in this instruction manual (30 minutes ON/30 minutes OFF) The device does not nebulize, or the nebulization is weak:
- Make sure the ends of the air tube are fitted tight lyon to the main unit and onto the nebulizer.
The device does not nebulize, or the nebulization is weak:
- Make sure the ends of the air tube are fitted tight lyonto the main unit and onto the nebulizer. The device does not nebulize, or the nebulization is weak:
- Check whether the nebulizer is empty of medication or overfilled with medication (maximum fill is 8ml)
- Check whether the nebu lizer nozzle is obstructed.
- Check whether the baffle is inserted properly.
MAINTENANCE AND REPAIR
Never open the device. There are no serviceable parts within the unit. The compressor requires no lubrication or maintenance.
TOMERSUP
CONTACT ADDRESSUSA Nureca INC.USA276 5th Avenue, Suite 704-397,New York (NY)-10001, USA INDIA Corporate Office (Mumbai)Nureca LimitedB2-166, Time Square, 7th and 8th Floor, CTS No 349and349-1 Western Express Highway, Andheri East,Mumbai, Mumbai City, Maharashtra, 400069Contact usIndia: +91-7527013265 /+91-9356658436Website: www.drtrustusa.comEmail: Connect with us on social networksFacebook: @drtrustlnstagram: @drtrustisinYoutube: NurecaUsaCOPYRIGHT© 2020 DR TRUST ALL RIGHTS RESERVED
Read More About This Manual & Download PDF:
[xyz-ips snippet=”download-snippet”]