electriQ TF46OSCT12RB 46 inch Tower Fan User Manual
Table of Contents
electriQ TF46OSCT12RB 46 inch Tower Fan
SAFETY INSTRUCTIONS
Important!
Carefully read the instructions before operating the unit
This appliance is for indoor use only.
Rating: This unit must be only connected to a 220-240 V ~ 50-60 Hz earthed outlet.
Installation must be in accordance with regulations of the country where the unit is used.
If you are in any doubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician.
This fan has been tested and is safe to use. However, as with any electrical appliance – use it with care.
Disconnect the power from the unit before dismantling, assembling or cleaning the unit
Avoid touching any moving parts of the appliance.
Never insert fingers, pencils or any other objects though the guard
This appliance can be used by Children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Do not clean the unit by spraying it or immersing it in water.
Never connect the unit to an electrical outlet using an extension cord. If an outlet is not available, one should be installed by a qualified electrician.
Never operate this appliance if the cord or plug is damaged. Ensure the power cord is not stretched or exposed to sharp object/edges.
A damaged supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
Any service other than regular cleaning should be performed by an authorized service representative. Failure to comply could result in a voided warranty.
Do not use the appliance for any purpose other than for its intended use.
Never use the mains plug as a switch to start and turn off the fan. Use the provided ON/OFF switch located on the control panel.
Always place the unit on a dry and stable surface. Do not move or tilt the unit
High Velocity fans are designed to create rapid air movement, therefore make sure the fan is not placed near curtains or any objects that may be drawn into the fan inlet.
The appliance should not be installed in laundry or wet rooms
Do not use this unit in environments with flammable and explosive gases.
Avoid keeping the unit in direct sunlight for a long period of time
TF46OSCT12RB 46 Inch Tower Fan with 3 Speed Settings
FEATURES
Slim design takes minimal space
LED Display showing the current temperature.
High Speed Motor with 3 Fan Speed Settings
Swing Function
12-hour standby timer.
Remote Control allowing all functions to be changed.
Choice of modes allowing the operation of the unit to be adjusted to theenvironment.
DIAGRAM
INSTALLATION
The base of the tower fan comes in two parts, which fit around the oscillation base. Both parts fit easily together. The back half is the one with cut-outs for the power supply cord.
First attach the front half of the base, aligning the holes in base with the screw holes in the base of the fan, and lead the power cable through the center hole.
Then attach the back half of the base to the front half and secure to the main body with the four supplied screws.
Thread the power supply cord through the two clips in the underside of the base.
OPERATION
Once assembled your fan may be operated by using either the manual controls located on the top of the fan or by your remote control.
CONTROL PANEL AND SETTINGS
POWER BUTTONUsed to turn the tower fan ON and OFF.
SPEED BUTTONPress to cycle through the three available fan speeds. Low Speed,Medium Speed, andHigh Speed.MODE /STYLE BUTTONPress to cycle through the modes.Standard Mode: The fan will operate normallyBreeze Mode: The fan speed will vary to imitate a natural breeze.Sleep Mode: The lights on the unit are extinguished, and the fan speed will reduce by 1 level every 30 minutes until on Low fan speed, and will then continue to run at that speed.
TIMER BUTTONPress repeatedly to increase the running time in 30-minute intervals. The timer can be set between 30 minutes and 7.5 hours.
SWING BUTTONPress to turn the Swing function on and off. When it is operational the horizontal direction of the airflow is slowly moved from side to side.LCD DISPLAY
FAN SPEED DISPLAYThe length of the bars indicates which of the three fan speeds the unit is operating in:Low Speed,Medium SpeedHigh Speed.
TEMP / TIMER DISPLAYThe display shows the current room temperature. When the timer is operational, the display will change to show the timer’s duration. The text above will show what figure is currently displayed.
MODE / STYLE INDICATOROne symbol will be displayed to indicate the current mode / Style.Standard ModeBreeze ModeSleep Mode
Oscillation / Swing IndicatorThe Oscillation symbol will be displayed when the oscillation/swing mode is active.
REMOTE CONTROL
The Buttons on the remote have the same effect as the buttons on the main control panel.
1
Power Button
2
Speed Button
3
Swing Button
4
Timer Button
5
Mode Button
The remote contains a button cell battery (CR2025)
MAINTENANCE
CLEANING AND STORAGE
ATTENTION: Please shut off the unit and unplug from the mains before cleaning or performing any maintenance.
Cleaning the surfaceClean the grills with a duster or a soft wet cloth. Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage. Make sure no water enters the control panel or fan motor Do not run the unit until completely dry. Place the fan in its original box or cover the fan to protect it from dust. Store it in a cool dry place.
Energy Saving and Unit Safety Protection Tips
Do not cover or restrict the airflow. Do not use in dusty environment.
For maximum performance the minimum distance from a wall or objects should be 50cm.Warning: To reduce the risk of fire or electrical shock, DO NOT USE THIS FAN with any SOLIDSTATE Speed Control Device or any variable speed controllers.
TROUBLESHOOTING
Do not repair or disassemble the unit by yourself, unauthorized repair attempts will invalidate the warranty and may cause bodily harm.
Issue
Possible Reason
Solution
No power
Power cord is unconnected
The There is no power from socket
The power switch is not on.
The fuse has blown
Connect the power cord
Check socket is turned on
Turn the unit on
Replace the fuse in the plug
Odour emission from unit
New unit. When the unit is used for the first time the fan motor may produce and odour which will dissipate within a week of use
No action required
Strong vibrations and noise
Fan is not used on a flat surface
Fan may be damaged
Place on a flat surface. May put an anti-vibration matt underneath
if fan is damaged discontinue use and contact service centre
If the above solutions do not resolve the problem please contact the service centre.
APPENDIX
Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating civic amenity sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centres.
TECHNICAL DATA
Description
Value
Unit
Model
TF46OSCT12RB
Fan Speeds
3
Cable length
1.5
meters
Rated Input
45
Watt
Running Current
0.2
Amps
Air Flow
39.63
m3/hr/min
Noise
Max 57.4
dB(A)
Power Supply
220-240/50-60
V/Hz
Net Weight
3.6
kg
Gross Weight
4.5
kg
Net Size (assembled)
315x315x1170
mm
Gross Size (packed)
1191x186x169
mm
TF46OSCT12RB
Description
Symbol
Value
Unit
Maximum Fan Flow Rate
F
39.63
m³/min
Fan Power Input
P
46.5
W
Service Value
SV
0.85
(m³/min)/W
Standby power consumption
PSB
0.578
W
Fan sound power level
LWA
57.4
dB(A)
Maximum Air Velocity
C
3.43
meter/sec
Measurement standard for service value
IEC 60879:1986+cor1:1992
electriQ UK SUPPORTwww.electriQ.co.uk/support Please, for your own convenience, make these simple checks before calling the service line.If the unit still fails to operate call: 03303903061 or complete the online form
Is the unit plugged into the mains?
Is the fuse OK?
Switch the unit off and wait three minutes to see if the issue is resolved. Restart the unit.
Office hours: 9AM – 5PM Monday to Friday www.electriQ.co.uk Unit J6 Lowfields Way Elland West Yorkshire HX5 9DAwww.electriQ.co.uk