ELRO Smoke Alarm Instruction Manual

ELRO Smoke Alarm Instruction Manual

Firstly

Follow instructions to ensure proper installation. Intended use: Fire detection and fire warning for household or similar residential applications. Local regulations shall be consulted.

INTENDED USE: FIRE SAFETYESSENTIAL CHARACTERISTICS: PASSED

Nominal activation conditions/ Sensitivity, Response delay (response time) and Performance under fire condition – Operational reliability – Tolerance to supply voltage – Durability of operational reliability and response delay, temperature resistance, vibration resistance, humidity resistance, corrosion resistance, electrical stability

Manufacturer:Siterwell Electronics CO., LimitedNo.666 Qingfeng Road, Jiangbei District,Ningbo, Zhejiang Province, China 315034

ImporterELRO Europe | www.elro.euPostbus 9607 – Box E8001006 GC Amsterdam The Netherlands

Content

Activate before use!Press and hold test button until LED lights up, then release immediately.

Testing

Mounting plate

Ceiling mounting

Rooms

Test & clean

Alarm silence

Low battery

Overview LED & acoustic signalling

Symbols:

Recycling and disposal: The WEEE symbol means that this product and batteries must be disposed separately from other household waste. When it reaches its end of life, take it to a designated waste collection point in your area to guarantee a safe disposal or recycling. Protect the environment, human health and natural resources!Read the manual before use and store it in a safe place for future use and maintenance.Download Declaration of Performance (DoP) at www.elro.eu.

Warnings:

  • To prevent injury, this apparatus must be securely attached to the ceiling in accordance with the installation instructions.
  • Batteries shall not be exposed to excessive heat such as sunshine and fire.
  • Battery lifetime shortens without monthly test.
  • Keep away from air conditioning/ventilation.
  • Do not paint or cover device.
  • Consult local regulations.

Troubleshooting:

False alarm is often caused by dust or steam. In case of doubt: Leave the building and take action! Additional mounting instructions: Corridor max width 3m: Max 15m between 2 alarms. Max. 7,5m to front side and alarms at edges/crossings of corridors. Galleries: Length and width >2m and >16m², additional alarms below gallery. Partial roof slopes: Flat ceiling ≤1m wide, consider as roof slope. Flat ceiling >1m wide, consider as flat ceiling.