EMERSON Electronic Ignition Gas Valves Installation Guide

EMERSON Electronic Ignition Gas Valves Installation Guide

80% of furnaces made in the past 15 years can be serviced with six 36J Gas Valve models

Trusted by more OEMs

White-Rodgers is the largest gas valve manufacturer in North America More OEMs use White-Rodgers than any other brand

 Ease of InstallationQuick connect spade terminals Most models include LP conversion kit Reducer bushing kit included on most models

DID YOU KNOW?36J series gas valves replace over 500 models.

FEATURES

  • Convertible – natural or LP gas
  • Adjustable regulator(s)
  • Inlet/outlet screens
  • Built-in pressure taps
  • Electric on-off switch
  • Quick connect spade terminals
  • Tamper resistant screws and controlled gasket compression to withstand high inlet pressures

SPECIFICATIONS

Electrical Rating

  • 28 Amps (Single Stage)
  • 43 Amps (Two-Stage)

Operating Voltage

  • 24 Vac 50/60 Hz

Temperature Operating Range

  • -40° to 175° F (-40° to 79° C)

Maximum Pressure Rating

  • 1/2″ PSI 14.0″ WC

Inlet & Outlet Pressure Taps

  • 1/8″ NPT

Mounting

  • Multipoise

Agency Approvals

  • CSA

Product View

  • 36G/36
  • 6J
  • 36G
Valve (Stages) Pipe Size 1” Pressure Drop Capacity Range of Regulation
BTU/HR BTU/HR
Std. Gas

.64 Sp. Gr.

(1000 Btu/ft3)

LP Gas

1.53 Sp. Gr. (2500 Btu/ft3)

Std Gas

.64 Sp. Gr.

(1000 Btu/ft3)

LP Gas

1.53 Sp. Gr. (2500 Btu/ft3)

Single 1/2” x 1/2” 140,000 226,800 20,000-210,000 65,000-340,000
Two 1/2” x 1/2” 140,000 226,800 20,000-210,000 65,000-340,000
Modulating 1/2” x 1/2” 140,000 226,800 40,000-210,000 65,600-340,000

 

Voltage Stages / Opening Pipe Size Regulator Setting Natural Gas Adj. Range (WC) Lp Gas Adj. Range (WC) LP Kit Incl. Reducer Bushing Kit Flow Direction Inlet / Outlet Pressure Tap HSI

/ DSI

Intermittent/ Proven Pilot Flange Mount Capable  

Model Number

 

Item Number

24 Vac 50/60Hz 1 – Stage Fast Open 1/2” X 1/2” 3.5” 2.5”-5.0” 7.0”-12.0” No** No Str. Thru Yes / Yes* Yes No No 36G22-254 36G22-254
24 Vac 50/60Hz 1 – Stage Fast Open 1/2” X 1/2” 3.5” 2.5”-5.0” 7.0”-12.0” Yes No Str. Thru Yes / Yes* NPT & Towers Yes Yes Yes 36G32-500 36G32-500
24 Vac 50/60Hz 1 – Stage Slow Open 1/2” X 1/2” 3.5” 2.5”-5.0” 7.0”-12.0” Yes No Str. Thru Yes / Yes* NPT & Towers Yes Yes Yes 36G33-500 36G33-500
24 Vac 50/60Hz 1 – Stage Fast Open 1/2” X 1/2” 3.5” 2.5”-5.0” 7.0”-12.0” Yes Yes Str. Thru Yes / Yes Yes No No 36J22-214 36J22-214
24 Vac 50/60Hz 1 – Stage Slow Open 1/2” X 1/2” 3.5” 2.5”-5.0” 7.0”-12.0” Yes Yes Str. Thru Yes / Yes Yes No No 36J24-214 36J24-214
24 Vac 50/60Hz Modulating 1/2” X 1/2” 3.5” 0.4”-4.0” 1.3”-11.5” Yes Yes Str. Thru Yes / Yes Yes No No 36J27-554 36J27-554
24 Vac 50/60Hz 2 – Stage Fast Open 1/2” X 1/2” 1.5” Low

3.5” High

1.0”-4.0” Low

2.0”-5.0” High

4.0”-10.0” Low

6.0”-12.0” High

Yes Yes Str. Thru Yes / Yes* Yes No No 36J54-214 36J54-214
24 Vac 50/60Hz 2 – Stage Slow Open 1/2” X 1/2” 1.5” Low

3.5” High

1.0”-4.0” Low

2.0”-5.0” High

4.0”-10.0” Low

6.0”-12.0” High

Yes Yes Str. Thru Yes / Yes* Yes No No 36J55-214 36J55-214
24 Vac 50/60Hz 1 – Stage Slow Open 1/2” X 1/2” 3.5” 2.5”-5.0” 7.0”-12.0” Yes No 90° Bottom Outlet Yes / Yes* Yes No No 36J24-614 36J24-614
24 Vac 50/60Hz 2 – Stage Slow Open 1/2” X 1/2” 1.5” Low

3.5” High

1.0”-4.0” Low

2.0”-5.0” High

4.0”-10.0” Low

6.0”-12.0” High

Yes No 90° Bottom Outlet Yes / Yes* Yes No No 36J55-614 36J55-614

** Use F92-0659 to convert to regulated L.P. gas Not for Standing Pilot* To measure outlet pressure on valves, loosen outlet pressure tap screw one quarter turn and put manometer hose over the top of the outlet pressure tap.

WR MOBILE APP

Answers at your fingertips, with your smartphone or tablet.

 

[xyz-ips snippet=”download-snippet”]