EMERSON KOLDPRO User Guide

Table of Contents

KOLDPRO©User guide

Our web-based tool allows for both quick design calculations and detailed design calculations, catering to all your cold room refrigeration load calculation requirements.Additional tools such as Sizing Guide and Psychrometric Calculator are also included.

Open KOLDPRO application

Quick design

  1. The first step is to select between quick design and detailed design.
  2. Upon clicking on quick design, the user will be asked to select the region, country, and city where the design condition will be based.
  3. The next step is to select the application, key in details for room conditions and surrounding temperature. Click “SAVE AND CONTINUE” once done.
  4. Under the quick design section, the user will be asked to enter unit run time and safety factor, room type and dimension, and product loading.4.1 Upon selecting the room type, the user is then required to provide the room dimension, together with the number of glass doors needed. Click “Save” once done.
  5. Construction material selection and details for walls, roof, and floor will be shown.Kindly note that the load calculation algorithm assumes that walls and roofs have identical insulation types and thicknesses. Click “SAVE AND CONTINUE” once done.
  6. The last step would be report generation. This is where the user will provide the project, customer, designer information, company logo, and recommendation.Click on “Save and Continue” to proceed.6.1 The user can send the generated report thru email, or save it in pdf or excel file format for future reference.

Detailed design

  1. The first step is to select between quick design and detailed designupon clicking on detailed design, the user will be asked to select the region, country, and city where the design condition will be based.
  2. The last step would be report generation. This is where the user will provide the project, customer, designer information, company logo, and recommendation.
  3. Under the detailed design section, the user will be asked to enter the details required for the load calculation summary.3.1 Transmission load3.1.1 Click on the drop-down menu and select room type.3.1.2. Select wall orientation (internal, north, south, east, and west) and enter room dimension. Click on “Save” once done.3.1.3 Select the type, thickness, and color of insulation to be used for walls, roof, and floor. The user can also select the type of door, door location, quantity, and measurement. Click on “Save” to proceed.3.2 Internal load3.2.1 Fill in the necessary information for internal load calculation.Lighting: the user may select the type of lamp from the drop-down list and calculate the load based on the number of lights or total load in watts.People: average number of people that will be entering the refrigerated space.Motor: select the motor size and location from the drop-down list.Equipment: the user may enter the load as either watt/ft2 or the total load.Click on “SAVE AND CONTINUE”.3.3 Infiltration loadSelect the infiltration method from the dropdown list and enter the required details for that method.3.3.1 Air change3.3.2 Door openings3.3.3 Directly specified3.4 Product loadSelect the product type and enter the product’s specifications.The product will be added to the table below upon clicking on “Add to list”. Click on “SAVE AND CONTINUE” once done.3.5 Load summary will be shown for checking and reference.Users can enter or change the unit run time and safety factor before proceeding to the next step.
  4. The last step would be report generation. This is where the user will provide the project, customer, and designer information, company logo, and recommendation.Click on “SAVE AND CONTINUE” to proceed.4.1 The user can send the generated report thru email, or save it in pdf or excel file format for future reference.

[email protected]EMERSON.CONSIDER IT SOLVED™.