General Safety Precautions

Read and follow all instructions, cautions and warnings. Failure to do so could result in personal injury, death or property damage.

Unit must be in OFF position and UNPLUGGED from power receptacle before performing any maintenance / service or before REMOVING access panels.

Make sure the electrical power source conforms to the requirement of the evaporative cooler as well as local codes.

To reduce risk of fire or electrical shock, do not expose electrical connections to water.

Do not touch electrically live components. Ensure all power cords do not touch sharp edges, hot surfaces or chemicals. Immediately replace damaged parts. Never leave unit unattended. Continuous fill not to be used indoors or unattended.

Operation Tips

Hessaire coolers are highly recommended for outdoor use. If used indoors, position cooler in front of window or open door for fresh intake air. Ensure there is an open door or window through which the air can exhaust from the room.

Clean media pads and tank frequently.

When shutting down unit, run without pump for 30 minutes to properly dry media pads.

Prior to long term storage: Drain tank and wipe clean Dry and clean rigid media pads

Inspection

After unpacking your cooler, carefully inspect for any damage that may have occurred during transit. Inspect for loose, missing or damaged parts. Note: wheels & hardware are located inside the cooler tank. Remove back panel to locate.

Contents: Evaporative Cooler (1), Hardware Bag/Hose Adapter (1), Caster Wheels (4).

Visit Hessaire.com to request replacement parts if any of these items are missing.

Quick Start

Note: Media pads may have a slight door upon initial startup but will go away with continued use.

Features

Control Panel For MC92V, M350

Switch for Fan Speeds: 4 Positions (OFF, LOW, MED, HIGH)Switch for Pump: ON/OFFSwitch for Swing (oscillation): ON/OFF

Maintenance

WARNING Disconnect from power source before attempting any maintenance or routine service. NEVER remove any access panels while cooler is in operation. Failure to do so could lead to SERIOUS INJURY

Cleaning Cooler & Rigid Media Pads:The removable panel(s) & pads can be gently sprayed off to remove build up. A soft bristle brush can also be used.

NEVER spray pads with water while cooler is in operation. Damage can occur to the motor and will void the warranty.

Note: Vinegar is recommended for cleaning of cooler and can be periodically cycled through during normal use.

Removal Of Back Panel:Disconnect power supply. Remove Philips screws from the upper back side of cooler.

Push panel up and pull bottom out to remove.

Storage:Drain tank and wipe dry. Plug is located on bottom of cooler. Ensure pads are dry by running fan without pump for at least 30 minutes.Visit Hessaire.com for additional maintenance tips andservice videos.

Troubleshooting

Cooler Parts

Hessaire Warranty

Each new cooler is warrantied to be free from defects in material or workmanship for one full year from the date of original purchase. If a component(s) is found to be defective within this period, a Hessaire representative will replace the defective part free of charge. Parts are available through authorized dealers or online. Copy of proof of purchase and serial label will be needed for the warranty claim.

What is not covered:Malfunctions resulting from misuse, negligence, alteration or lack of necessary maintenance. Loss of time, inconvenience, use of product or other consequential damages due to defects. Return transportation costs. All return costs are the responsibility of the purchaser. Hessaire does not cover labour costs associated with troubleshooting or cooler repairs regardless if the product is under warranty or not.

Damaged Shipments:Hessaire is not responsible for damaged shipments or shortages resulting from carrier mishandling. Notify your carrier’s office immediately to file a freight claim in the event of damage. Keep damaged product for inspection until advised by carrier as to disposal.

Returns:Hessaire’s dealers shall implement a return policy that is consistent with the dealer agreement. If the dealer’s return policy allows returns within a specified time period–agreed to by Hessaire and dealer, customer may return product to point of purchase. Dealer may reject, accept or accept with a restocking fee at the sole discretion of the dealer. If the customer wishes to repair the defective cooler, the customer can contact Hessaire for a list of authorized repair centres for parts and troubleshooting. Defective parts are provided free of charge within the warranty period.Please DO NOT return your cooler to Hessaire. Upon authorization, any returns should be sent directly to the distributor/store where purchased.Visit hessaire.com for registration & warranty claim forms.