Homedics RWS-100 Restore Clean Water System Instruction Manual and Warranty Information

Distributed By

Restore™ Clean Water System

RWS-100Instruction Manual and Warranty Information3 year limited warranty 

Excludes replaceable filter

IMPORTANT SAFEGUARDS

WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS  BE FOLLOWED, INCLUDING THE FOLLOWING: READ ALL INSTRUCTIONS BEFORE USING

DANGER—TO REDUCE THE RISK OF ELECTRIC SHOCK:

  • ALWAYS unplug the appliance from the electrical outlet immediately after using and before cleaning.
  • DO NOT reach for an appliance that has fallen into water. Unplug it immediately.
  • DO NOT place or store appliance where it can fall or be pulled into a tub or sink. DO NOT place in or drop into water or other liquid.
  • House wiring must comply with all local electrical codes. The improper electrical connection can result in a risk of electrical shock.
  • The outside of the appliance must be dry before applying electrical power.
  • Only use the product in a 3 pronged outlet.

WARNING – TO REDUCE THE RISK OF BURNS, ELECTRIC SHOCK, FIRE OR INJURY TO PERSONS:

  • An appliance should NEVER be left unattended when plugged in. Unplug from outlet when not in use or before cleaning or filter replacement.
  • ALWAYS operate indoors.
  • The appliance blocks all harmful Ultraviolet (UV) light when operated according to instructions.
  • The reservoir, lid, and spout lid must be fully seated during operation.
  • Use this appliance only for its intended use as described in this manual. DO NOT use attachments not recommended by HoMedics. Specifically, any attachments not provided with the unit.
  • DO NOT carry this appliance by the power cord or use the cord as a handle.
  • NEVER operate this appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water.  Return it to HoMedics Service Center for examination and repair.
  • Keep cord away from heated surfaces.
  • DO NOT activate the UV lamp without lid in place (spout lid must be in closed position), which prevents exposure to harmful UV light.
  • NEVER place appliance on a soft surface, such as a bed or couch.
  • NEVER drop or insert any object into any opening.
  • DO NOT operate where aerosol (spray) products are being used or where oxygen is being administered.
  • To disconnect adaptor, remove plug from AC outlet. To disconnect pitcher, remove power cable from socket on reservoir.

SAVE THESE INSTRUCTIONS

Caution: Please read all instructions carefully before operating.

  • Only use clear, cool tap water in this product as it is not designed to purify water from other sources.
  • DO NOT place the water system in the dishwasher as the unit is not dishwasher safe.
  • DO NOT place the water system in standing water such as a sink or a dishpan.
  • Unplug unit from the power adaptor before cleaning or replacing the filter.
  • NEVER leave the appliance unattended while cord is connected to pitcher, especially if children are present.
  • This unit should not be used by children or invalids without adult supervision.
  • DO NOT attempt to open the product. No user-serviceable parts are inside the Appliance.
  • Use only factory-authorized replacement parts.
  • For household use only. DO NOT use product for any other use.
  • DO NOT use the product if any leaks develop.
  • DO NOT use with hot water as it may damage the product.
  • The UV lamp contains a small amount of mercury. Please dispose of in accordance to local, state, and federal laws.
  • Failure to activate the UV lamp means water has not been purified for bacteria, viruses, and cysts by this unit.

Instructions for Use

This plug will fit in an outlet only one way. If it does not fit, contact a qualified electrician to install the proper outlet. Do not modify the plugin anyway.

Getting StartedPITCHER WITH FILTER

  1. Wash the lid, reservoir, and pitcher with mild soapy water. Do not use any abrasive cleaners. Replace the reservoir back in the water system.
  2. Wash your hands in soap and water.
  3. Remove the filter from the protective wrapper. Some moisture and black carbon dust inside is normal.
  4. Rinse the filter under tap water for a few seconds.
  5. Immerse filter in water for 15 minutes then shake back and forth to remove air bubbles. (fig. 1)
  6. Wipe the filter and reservoir clean to ensure carbon dust will not prevent a proper seal.
  7. Place the filter in the reservoir and press down until it is firmly seated. (fig. 2)

  8. Move the valve on the handle down to the FILL position. (fig. 3)

  9. Fill the reservoir to the 4 cup fill line with cool tap water and let the water flow through the filter into the pitcher body.
  10. Repeat step 9 to fill to the 8 cup capacity.
  11. Discard the first two pitchers of filtered water or use for plants. It is normal for carbon dust to appear in your first fillings.

ADAPTER

  1. The adapter operates using one lithium CR2032 battery (pre-installed). There is a plastic strip under the lithium battery to prevent battery drain in shipping.  Remove the strip before continuing to the operating instructions.

Operating Instructions

  1. Move the valve on the handle down to the FILL position. (fig. 3)

  2. Fill the reservoir as shown to the fill line with cool tap water. (fig. 4).

    Note – The maximum capacity of the PITCHER BODY is 8 cups. Use the fill lines in the RESERVOIR & the fill lines on the PITCHER BODY to ensure you do not exceed the maximum 8 Cup capacity.

  3. Allow the water to flow though the filter into the pitcher.
  4. Replace the lid. Ensure the spout lid is in the closed position.
  5. Extend the retractable cable and plug the adapter into an outlet.
  6. Plug the adapter cable into the water system. (fig. 5)

  7. Slide the valve up to the PURIFY position. This will prevent tap water from coming into contact with UV purified water.
  8. Press the PURIFY button on the adapter. (fig. 6) The UV light will activate for the required time to clean your water. The time will be approximately one minute.  If the PURIFY lights blink, your water has not been fully purified. Do not drink the water yet. See the Troubleshooting section.Note – The bulb may illuminate with a pink hue, changing to blue as the purification cycle continues. This is acceptable and does not affect performance.
  9. After the PURIFY light is off, unplug adapter from system and retract cord.Note – You may leave the adapter plugged in the AC outlet with the cord retracted or store in a drawer for the next use.
  10. Your water is ready to drink. Additional uses include cooking, coffee, tea, juice, baby formula, ice, pet bowls and more.

Note – You may store the pitcher in the refrigerator. Re-purify water if it sits out for more than 2 days.

User Settings

PurifyThis feature activates a UV light to purify your water.

  • To purify your water, press the PURIFY button. If the PURIFY light blinks, see the Troubleshooting section.

Automatic Filter AlertThis feature alerts you when it is time to replace your filter.If the replace filter indicator is illuminated.

  • Replace the filter with a new one. See the Getting Started section for detailed instructions.
  • Press and hold the replace filter indicator button until the indicator resets.

The REPLACE FILTER notification will vary based on the CUPS PER DAY setting. It is recommended to set this setting as accurately as possible to obtain maximum filter life.

Cups per dayThis feature provides you with a more accurate filter life measurement by allowing you to set your daily consumption level.

  • Select the proper number of cups per day by pushing the CUPS PER DAY button until the desired usage is selected.
  • For your reference in setting your consumption level a full pitcher capacity is 8 cups.
  • If the consumption changes you can change the setting at any time and the filter life will automatically adjust.
  • A filter will last approximately 2 months with average household use.

NOTE: For maximum efficiency do not purify more than 2 gallons per day.

Caution: Restore™ Water System is not dishwasher safe.Caution: All servicing of this water system must be performed by authorized HoMedics service personnel only.

Maintenance

To Clean

  • Pour out water.
  • To ensure that the UV lamp assembly introduces the proper dose of Ultraviolet light into the water the lamps protective outer quartz sleeve is to be cleaned once each month by wiping it with white vinegar and then rinsing. (fig. 7)
  • Unplug adapter and wipe with a moist cloth. Dry before use.
  • Hand wash all parts, except the adapter, with mild dish soap before use or after storing for an extended period of time.
  • Do not use abrasive cleaners or scrubbers.
  • Your Restore™ Water System is not dishwasher safe.

To Store

  • Follow cleaning instructions above.
  • Unplug the adapter from the outlet.
  • Retract adapter power cable.
  • Dry all standing water.
  • Store in original box.

FCC Notice

Note – This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

Note – This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency  energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception, which can be  determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.Note – The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user authority to operate the equipment.

Troubleshooting

The UV will not activatePlease make sure the following steps have been taken:

  • The valve is in the PURIFY position.
  • The Adapter is plugged into a functional 3 pronged outlet.
  • The Adapter cord is firmly seated in the pitcher base.
  • The reservoir and lid must be installed and firmly seated.
  • The Adapter battery is installed correctly. See adapter battery door for instructions.
  • Once the above steps have been taken, press and hold the PURIFY button on the Adapter

The REPLACE FILTER indicator is blinkingIn this condition the filter timer has expired indicating the filter should be replaced.

  • First follow steps to replace the filter in the Getting Started section.
  • To reset the timer, and turn off the blinking indication, hold the button down for 5 seconds.
  • The timer now begins the timing duration prescribed by the programmed Cups per Day setting. See the User Interface section for setting the Cups per Day.

Performance Data Sheet

HoMedics Restore™ Water System-Model: RWS-100 Replacement Filter-Model: RWS-1FL

Distributed by HoMedics, Inc.3000 Pontiac Trail, Commerce Township, MI 48390

This system has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42  and 53. Testing was performed under standard laboratory conditions, actual performance may vary.

Substance

Influent Challenge Concentration

Maximum Permissable Concentration

Average Actual Reduction

NSF 42 – Aesthetic Effects

Chlorine – Taste and Odor

2 mg/L ± 10%

1 mg/L

98.9%

Zinc

10 mg/L ± 10%

5 mg/L

86.2%

NSF 53 – Health Effects

Benzene

0.015 mg/L ± 10%

0.005 mg/L

94.4%

Cadmium – pH 6.5

0.03 mg/L ± 10%

0.005 mg/L

91.8%

Cadmium – pH 8.5

0.03 mg/L ± 10%

0.005 mg/L

89.9%

Copper – pH 6.5

3 mg/L ± 10%

1.3 mg/L

89.7%

Copper – pH 8.5

3 mg/L ± 10%

1.3 mg/L

77.9%

Lindane*

0.002 mg/L ± 10%

0.0002 mg/L

99%

Mercury – pH 6.5

0.006 mg/L ± 10%

0.002 mg/L

96.2%

Mercury – pH 8.5

0.006 mg/L ± 10%

0.002 mg/L

94.3%

Tetrachloroethylene

0.015 mg/L ± 10%

0.005 mg/L

93.2%

Toluene

3 mg/L ± 10%

1 mg/L

99.4%

*Compliant for Lindane reduction requirements under NSF/ANSI Standard 53 as tested by PACE Analytical Services, Inc.

This system has been independently tested by PACE Analytical Services, Inc. according to NSF/ANSI 53 (1988) for the reduction of lead.

Substance

Infl uent Challenge Concentration

Maximum Permissable Concentration

Average Actual Reduction

NSF 53 (1988)

Lead pH 7.5**

0.150 mg/L ± 10%

0.020 mg/L

98.7%

Microbiological Performance

Bacteria: 99.9999% or 6 log reductionVirus: 99.99% or 4 log reductionCyst: 99.95% or 3.5 log reduction

Intended for the supplemental purification of visually clear tap water only.

Technical SpecificationsFlow: 2 gallons per day (7.5 liters)Capacity: 40 gallons (151 liters)Typical Bulb Life: 10 yearsElectrical Ratings: 120 Vac @ 15 WattsOperating Temperature: 50˚ – 85˚ F (10˚ – 29˚ C)Note – No warranty is made for use with water at higher or lower temperatures.Please refer elsewhere in this Instruction Manual for the proper conditioning, use, and care requirements.Suggested Retail for Replacement Filter RWS-1FL: $8.00To purchase a replacement filter see www.homedics.com/restore

Purchases Made in Iowa

LIMITED THREE YEAR WARRANTY (EXCLUDES REPLACEABLE FILTER)

HoMedics sells its products with the intent that they are free of defects in manufacture and workmanship for a period of three years from the date of original purchase, except as noted below. HoMedics warrants that its products will be free of defects in material and workmanship under normal use and service. This warranty extends only to consumers and does not extend to Retailers.To obtain warranty service on your HoMedics product, mail the product and your dated sales receipt (as proof of purchase), postpaid, to the following address:HoMedics Consumer RelationsService Center Dept. 1683000 Pontiac TrailCommerce Township, MI 48390No COD’s will be accepted.

HoMedics does not authorize anyone, including but not limited to Retailers, the subsequent consumer purchaser of the product from a Retailer or remote purchasers, to obligate HoMedics in any way beyond the terms set forth herein. This warranty does not cover the replacement filter; damage caused by misuse or abuse; accident; the attachment of any unauthorized accessory; alteration to the product; improper installation; unauthorized repairs or modifications; improper use of electrical/power supply; loss of power; dropped product; malfunction or damage of an operating part from failure to provide manufacturer’s recommended maintenance; transportation damage; theft; neglect; vandalism, environmental conditions; loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair; or any other conditions whatsoever that are beyond the control of HoMedics.

This warranty is effective only if the product is purchased and operated in the country in which the product is purchased. A product that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed, manufactured, approved and/or authorized, or repair of products damaged by these modifications is not covered under this warranty.

THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY. THERE SHALL BE NO OTHER WARRANTIES  EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS OR ANY OTHER OBLIGATION ON  THE PART OF THE COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY. HOMEDICS SHALL HAVE NO LIABILITY  FOR ANY INCIDENTAL, CONSEQUENTIAL, OR SPECIAL DAMAGES. IN NO EVENT SHALL THIS WARRANTY REQUIRE MORE THAN THE  REPAIR OR REPLACEMENT OF ANY PART OR PARTS WHICH ARE FOUND TO BE DEFECTIVE WITHIN THE EFFECTIVE PERIOD OF THE  WARRANTY. NO REFUNDS WILL BE GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE MATERIALS ARE NOT AVAILABLE, HOMEDICS  RESERVES THE RIGHT TO MAKE PRODUCT SUBSTITUTIONS IN LIEU OF REPAIR OR REPLACEMENT.

This warranty does not extend to the purchase of opened, used, repaired, repackaged, and/or resealed products, including but not limited to sale of such products on Internet auction sites and/or sales of such products by surplus or bulk resellers. Any and all warranties or guarantees shall immediately cease and terminate as to any products or parts thereof which are repaired, replaced, altered, or modified, without the prior express and written consent of HoMedics.

This warranty provides you with specific legal rights. You may have additional rights which may vary from country to country. Because of individual country regulations, some of the above limitations and exclusions may not apply to you.For more information regarding our product line in the USA, please visit: www.homedics.com

Mail To:HoMedicsService Center Dept. 1683000 Pontiac TrailCommerce Township MI 48390HoMedics Service Center: 1-800-466-33428:30-5:00pm (EST) M-FEmail: [email protected]

©2009 HoMedics, Inc. and its affiliated companies, all rights reserved.HoMedics® is a registered trademark of HoMedics Inc. and its affiliated companies.Restore™ is a trademark of HoMedics Inc. and its affiliated companies. All rights reserved.IB-RWS100A

Homedics RWS-100 Restore Clean Water System Instruction Manual and Warranty Information – Homedics RWS-100 Restore Clean Water System Instruction Manual and Warranty Information –