Homedics UHE-CM25 Cool Mist Ultrasonic Humidifier Instruction Manual and Warranty Information

Homedics UHE-CM25 Cool Mist Ultrasonic Humidifier Instruction Manual and Warranty Information

IMPORTANT SAFETY INSTRUCTIONS:

WHEN USING ELECTRICAL PRODUCTS, ESPECIALLY WHEN CHILDREN ARE PRESENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:

READ ALL INSTRUCTIONS BEFORE USING

DANGER – TO REDUCE THE RISK OF ELECTRIC SHOCK:

  • Always place humidifier on a firm, flat surface. A waterproof mat or pad is recommended for use under the humidifier. Never place it on a rug or carpet, or on a finished floor that may be damagedby exposure to water or moisture.
  • Always unplug the unit from the electrical outlet immediately after using and before cleaning
  •  DO NOT reach for a unit that has fallen into water. Unplug it immediately.
  • DO NOT use while bathing or in the shower.
  • DO NOT place or store the unit where it can fall or be pulled into a tub or sink.
  • DO NOT place or drop into water or other liquids.
  • DO NOT use water above 86° Fahrenheit.

WARNING – TO REDUCE THE RISK OF BURNS, ELECTRIC SHOCK, FIRE OR INJURY TO PERSONS:

  • A unit should never be left unattended while plugged in.
  • Close supervision is necessary when this unit is used by or near children, invalids, or disabled persons.
  • Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by HoMedics; specifically any attachments not provided with this unit.
  • NEVER drop or insert any object into any opening.
  • DO NOT operate where aerosol (spray) products are being used, or where oxygen is being administered.
  • Always hold the water tank firmly with both hands when carrying a full tank of water.
  • NEVER use the humidifier in an environment where explosive gasses are present.
  • DO NOT place the humidifier near heat sources, such as a stove, and do not expose the humidifier to direct sunlight.
  • DO NOT carry this unit by the power cord or use the power cord as a handle.
  • To disconnect, turn all controls to the “off” position, then remove the plug from the outlet.
  • This unit is designed for personal, non-professional use only.
  • DO NOT use outdoors. For indoor use only.

SAVE THESE INSTRUCTIONS

CAUTION – PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATION.

  • Never cover the unit while it is operating.
  • Always keep the cord away from high temperature and fire.
  •  If the cord sustains damage, you must stop using this product immediately and contact HoMedics consumer relations (see Warranty section for consumer relations contact information).
  • Perform regular maintenance on the ultrasonic membrane.
  • Never use detergent to clean the ultrasonic membrane.
  • Never clean the ultrasonic membrane by scraping with a hard object.
  • Do not attempt to adjust or repair the unit. Servicing must be performed by professional or qualified personnel.
  • Stop using this unit if there is an unusual noise or smell.
  • Unplug this unit when not in use for a long period of time.
  • Do not touch the water or any parts of the unit that are covered by water while the unit is on or plugged in.
  • Never operate without water in the tank.
  • Only use water in the tank.
  • Never use any additive to the water.
  • Do not wash, adjust, or move this unit without first unplugging it from the electrical outlet.
  • Keep this unit out of reach of children. Do not allow children to use this unit without supervision.

Unique Features and Specifications

Ultrasonic TechnologyThis humidifier uses ultrasonic high frequency technology to convert the water into 1-5 million super particles that are dispersed into the air evenly.

Night LightA useful night light feature is included for your convenience.

Auto Shut-Off ProtectionWhen the tank is empty the unit will shut off automatically.

Voltage                                           Watts                  Tank Capacity110–120V/60Hz                            25                        gallon – 3.78 liters

Ultrasonic Cool Mist Humidifier

How To UseCAUTION: This appliance has a polarized plug (one blade wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician.DO NOT attempt to defeat this safety feature. To do so could result in an electric shock hazard.

How To Use

Power/Mist KnobPlug unit into a 120 volt AC electrical outlet. Turn the POWER/MIST ( ) knob clockwise toturn the humidifier on.

ATTENTION: When the water in the tank is almost empty, the humidifying function will power offto indicate to the user to refill the tank.

Mist Adjustment SettingMist adjusts from MINIMUM ( ) mist to MAXIMUM ( ) mist. To increase the mist output,turn the POWER/MIST knob clockwise. To decrease mist output, turn the POWER/MIST knobcounter-clockwise.

Night LightPress the NIGHT LIGHT ( ) button to turn on the night light. The surround around thePOWER/MIST knob will glow softly.

How to FillCAUTION: Before filling unit with water, turn power off and unplug unit from the outlet.Note: Always use two hands to carry the water tank.

  1. Grasp tank handle and lift up from humidifier base.
  2. Turn the tank upside down—remove the tank cap by turning it counter-clockwise.
  3. Fill the water tank with clean, cool (not cold) water. We recommend using distilled water if you live in a hard water area.
  4. Replace the tank cap by turning clockwise until tight.
  5. Install the tank back on the base of the unit. Make sure the tank is firmly seated.

About White Dust:Use of high mineral content hard water may cause a white mineral residue to accumulate on surfaces in the room near the humidifier. The mineral residue is commonly called “white dust.”The higher the mineral content (or, the harder your water is), the greater the potential for white dust. The white dust is not caused by a defect in the humidifier. It is caused only by mineralssuspended in the water.

 

How and Why To Use Demineralization Cartridges:The HoMedics demineralization cartridge will help reduce the potential for white dust, a deposit of minerals left behind from using hard water in your humidifier. The cartridge should be replaced every 30 – 40 fillings. The cartridge may need to be replaced more often if you are using very hard water. Replace the cartridge when you notice an increase in white dust build-up. If white dust still forms around the humidifier after a new cartridge has been installed, consider using distilled water. To purchase new demineralization cartridges, model # HUM-HDDC4-6CTM, goback to the retailer (where you purchased your humidifier), or visit www.homedics.com

If you live in an area with hard water, or use a water softener, we recommend usingdistilled water for better results from your humidifier. Never use water softening additives in your humidifier.

Installing Instructions

  1.  Remove demineralization cartridge from packaging and let it soak in water for 10 minutes.
  2. Remove the tank from humidifier base. (Fig. 3)
  3. Place the soaked demineralization cartridge into the matching slot in the humidifier base. (Fig. 9)
  4. Place the tank back on the base, making sure the tank is firmly seated. (Fig. 7)

Note: Demineralization cartridge has no top or bottom. Either side canface upward.

Cleaning and Care

CAUTION: Before cleaning the unit, turn power off and unplug unit from the outlet.

Tank CleaningRemove the water tank from the humidifier base by lifting it from the main unit. Unscrew the tank cap and rinse inside the tank with clean water. To remove any scale or build up, use a 50/50 mixture of vinegar and lukewarm water to clean the inside of the tank.Suggestion: Clean the water tank once every two to three weeks, depending on your water conditions.

To Clean the Ultrasonic Membrane:Put a small amount of mild dish soap on the surface of the ultrasonic membrane, then pour in some water and soak for 5 minutes. Brush clean with soft bristle brush (not included) and rinse. (Fig. 11)Suggestion: Clean the membrane once every two to three weeks, depending on your water conditions.

NOTE: Never submerge the base in water or any liquid.Surface Cleaning Clean the surface of the unit with a clean damp soft cloth as often as needed. (Fig. 12)

Troubleshooting

 

 

 

 

 

 

 

 

 

 

 

 

LIMITED ONE YEAR WARRANTY

HoMedics sells its products with the intent that they are free of defects in manufacture and workmanship for a period of one year from the date of original purchase, except as noted below. HoMedics warrants that its products will be free of defects in material and workmanship under normal use and service. This warranty extends only to consumers and does not extend to Retailers.To obtain warranty service on your HoMedics product, contact a Consumer Relations Representative by telephone at 1-800-466-3342 for assistance. Please make sure to have the model number of the product available.No COD’s will be accepted.HoMedics does not authorize anyone, including, but not limited to, Retailers, the subsequent consumer purchaser of the product from a Retailer or remote purchasers, to obligate HoMedics in any way beyond the terms set forth herein. This warranty does not cover damage caused by misuse or abuse; accident; the attachment of any unauthorized accessory; alteration to the product; improper installation; unauthorized repairs or modifications; improper use of electrical/power supply; loss of power; dropped product; malfunction or damage of an operating part from failure to provide manufacturer’s recommended maintenance; transportation damage; theft; neglect; vandalism; or environmental conditions; loss of use during the period the product is at a repair facility or otherwise awaiting parts or repair; or any other conditions whatsoever that are beyond the control of HoMedics.This warranty is effective only if the product is purchased and operated in the country in which the product is purchased. A product that requires modifications or adoption to enable it to operate in any other country than the country for which it was designed, manufactured, approved and/or authorized, or repair of products damaged by these modifications is not covered under this warranty.THE WARRANTY PROVIDED HEREIN SHALL BE THE SOLE AND EXCLUSIVE WARRANTY. THERE SHALL BE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FiTNESS OR ANY OTHER OBLIGATION ON THE PART OF THE COMPANY WITH RESPECT TO PRODUCTS COVERED BY THIS WARRANTY. HOMEDICS SHALL HAVE NO LIABILITY FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES. IN NO EVENT SHALL THIS WARRANTY REQUIRE MORE THAN THE REPAIR OR REPLACEMENT OF ANY PART OR PARTS WHICH ARE FOUND TO BE DEFECTIVE WITHIN THE EFFECTIVE PERIOD OF THE WARRANTY. NO REFUNDS WILL BE GIVEN. IF REPLACEMENT PARTS FOR DEFECTIVE MATERIALS ARE NOT AVAILABLE, HOMEDICS RESERVES THE RIGHT TO MAKE PRODUCT SUBSTITUTIONS IN LIEU OF REPAIR OR REPLACEMENT.This warranty does not extend to the purchase of opened, used, repaired, repackaged and/or resealed products, including but not limited to sale of such products on Internet auction sites and/or sales of such products by surplus or bulk resellers. Any and all warranties or guarantees shall immediately cease and terminate as to any products or parts thereof which are repaired, replaced, altered, or modified, without the prior express and written consent of HoMedics.This warranty provides you with specific legal rights. You may have additional rights which may vary from country to country. Because of individual country regulations, some of the above limitations and exclusions may not apply to you.For more information regarding our product line in the USA, please visit: www.homedics.com

 

Read More About This Manual & Download PDF:

 

Homedics UHE-CM25 Cool Mist Ultrasonic Humidifier Instruction Manual and Warranty Information – Homedics UHE-CM25 Cool Mist Ultrasonic Humidifier Instruction Manual and Warranty Information –

[xyz-ips snippet=”download-snippet”]


Posted

in

by