Homedics WF-MN-OAS EnviraScape Mini Oasis Tabletop Relaxation Fountain Instruction Manual and Warranty Information

One Year Limited Warranty (Valid in USA only)

HoMedics, Inc., guarantees this product free from defects in materialand workmanship for a period of one year from the date of purchase,except as noted below.This HoMedics product warranty does not cover damage caused bymisuse or abuse, accident, the attachment of any unauthorizedaccessory, alteration to the product, or any other conditionswhatsoever that are beyond the control of HoMedics. This warranty iseffective only if the product is purchased and operated in the USA. Aproduct that requires modification or adaptation to enable it to operatein any country other than the country for which it was designed,manufactured, approved and/or authorized, repair of productsdamaged by these modifications is not covered under warranty.HoMedics shall not be responsible for any type of incidental,consequential or special damages. All implied warranties, includingbut not limited to those implied warranties of fitness andmerchantability, are limited in the total duration of one year from theoriginal purchase date.To obtain warranty service on this product, either hand deliver or mailthe unit and your dated sales receipt (as proof of purchase), postpaid,along with a check or money order in the amount of $10.00 payable toHoMedics, Inc. to cover handling.Upon receipt, HoMedics will repair or replace, as appropriate, theproduct and return it to you, postpaid. Warranty is solely throughHoMedics Service Center. Service of this product by anyone otherthan HoMedics Service Center voids warranty.This warranty provides you with specific legal rights. You may haveadditional rights which may vary from state to state. Because ofindividual state regulations, some of the above limitations andexclusions may not apply to you.For more information regarding our product line in the USA, please visit:www.homedics.com

The sounds of mother nature soothe human nature

Thank you for purchasing the HoMedics’ EnviraScape Mini OasisTabletop Relaxation Fountain. Like the entire line of HoMedics products,it is built with high-quality craftsmanship to provide you withyears of dependable service. We hope you find it to be the finestproduct of its kind.EnviraScape enables you to create an all-encompassing environmentwith sound. The sound of flowing water enhances your environment byreleasing negative ions, and promoting relaxation. Only EnviraScapeoffers you the luxury of these vital benefits. Through its creative design,beauty is added to any indoor environment.

EnviraScape Features

Innovative, Artistic DesignEnhances the environment at home or at work.Variable Water Flow SpeedsControls the speed that meets your mood.Durable Electrical Water PumpCan be operated from any indoor 120 volt A/C electrical outlet.Easy to AssembleAssembles in minutes with simple, illustrated instructions.

IMPORTANT SAFETY INSTRUCTIONS:

When using an electrical appliance, basic precautions shouldalways be followed, including the following:READ ALL INSTRUCTIONS BEFORE USING

DANGER – To reduce the risk of electric shock:

  • Always unplug the appliance from the electrical outlet immediatelyafter using and before cleaning.
  • Do not reach for an appliance that has fallen into water. Unplug itimmediately.
  • Do not place or store appliance where it can fall or be pulled into atub or sink. Do not place in or drop into water or other liquid.
  • To reduce the risk of electric shock, connect only to a 120 volt A/Chousehold outlet. Do not connect to any voltage other than thatshown on the pump.
  • Do not pump flammable liquids through the water pump.
  • Do not use water above 86 degrees Fahrenheit.

Caution:

The pump must be completely submerged in water. If thepump is making noises, most likely it is not completely submergedin water

WARNING – To reduce the risk of burns, fire, electric shock orinjury to persons:

  • An appliance should never be left unattended when plugged in.Unplug unit from outlet when not in use and before putting on ortaking off parts or attachments.
  • Close supervision is necessary when this appliance is used by ornear children, invalids or disabled persons.
  • Use this appliance only for its intended use as described in thismanual. Do not use attachments not recommended by HoMedics,specifically any attachment not provided with the unit.
  • Do not operate this appliance if it has a damaged cord or plug, if itis not working properly, if it has been dropped or damaged, or ifthe cord has been dropped into water. Return it to the HoMedicsService Center for examination and repair.
  • Keep cord away from heated surfaces.
  • Never drop or insert any object into any opening unless otherwisedirected in this instruction manual.
  • Do not operate where aerosol spray products are being used orwhere oxygen is being administered.
  • Do not carry this appliance by the electrical cord or use the cordas a handle.
  • To disconnect, remove plug from outlet.
  • This appliance is designed for indoor use only. Do not use outdoors.

Caution:Only set the fountain and fountain parts on waterproof surfaces

SAVE THESE INSTRUCTIONS

Caution – Please read all instructionscarefully before operating.

  • Never leave appliance unattended while operating the unit,especially if children are present.
  • Never cover unit when it is in operation.
  • Connect the pump only to 120 volt A/C household outlet asindicated on the pump label.
  • Always keep the cord away from high temperatures.
  • Unplug the water pump from the power source before cleaning,performing maintenance, or disassembling.
  • To get the most efficient flowing effect, product must be placed ona level and sturdy surface before using, and should not be placedon any type of electrical appliance.
  • Never let the water pump run without water. This will shorten thelife of the pump.
  • Operate with freshwater (tap water) only. The pump is notequipped to run with saltwater (sea water).
  • Operate pump completely submerged for proper cooling.
  • The electrical cord of this product cannot be replaced. If it sustainsdamage, you must stop using the appliance immediately andreturn it to the HoMedics Service Center for examination andrepair. (See the warranty section for HoMedics address).
  • Disconnect the appliance from the electrical outlet before puttinghands into water.

Assembly and Instructions for Use

  1. Remove all contents from packaging and inspect to make sureall components have been received (Fig. 1):• Base with attached electrical cord and water pump• Fountain top• Polished river rocks• A/C Adaptor
  2. Wipe any dust off the interior and exterior of the base and topand rinse river rocks under water.
  3. Familiarize yourself with the pump. The pump speed iscontrolled by the dial located at the front of the pump. The speedis indicated by a “-” and “+”. To increase the speed, move thedial downward in the direction of the “+”. At its highest speedlevel, the dial will cease to move any further. To decrease thepump speed, move the dial upward toward the “-”. Similarly, atits lowest speed, the dial will cease to move any further (Fig. 2). NOTE: It is recommended the pump be set at itshighest speed during assembly and later adjustedto a lower setting if desired. Be sure to unplug thepump before adjusting the speed setting.
  4. Place the fountain base on a sturdy, level surfacein the desired location, ensuring its electrical cordwill sufficiently reach an electrical outlet. Onceassembled, the fountain may be difficult to movedue to splashing. Once in the desired location,lead the power cord attached to the base throughthe notch at the bottom of the base to ensure thebase sits level without wobbling. Attach the A/Cadaptor jack to the base power cord. Do NOT plugin at this time (Fig. 3).
  5. Add clean water to the base until the water levelis 1/2” to 3/4” below the rim.
  6. Connect the PVC tube to the pump, adjust thepump speed and place the fountain top on the base (Fig. 4).
  7. Place the fountain top on to the base and thenarrange the polished river rocks around thefountain top. (Be sure not to place any rocksinside the base of the fountain).
  8. Plug the A/C adaptor into a 120V household outlet.The fountain is controlled by the switch located onthe power cord. If pump doesn’t operate, rotate inlineswitch once to turn “on” and once more to turn“off”.NOTE: If you can hear the pump gurgling or makingsounds, you have not added enough water to cover(submerge) the pump.
  9. It will be necessary to add water occasionally dueto evaporation.NOTE: Always add water when fountain is “OFF”to avoid overflow.

Maintenance:

  • To clean the pump:Unplug the fountain from the electrical outlet. Remove thepump from the base of the fountain. Use a small brush orstream of water to remove any debris.
  • To keep water clean:Periodically change the water and clean the product accordingto the water condition. Keeping the water clean prevents thewater from becoming sticky and forming micro-organisms. Analgaecide or humidifier/vaporizer treatment can be added tohelp keep it clean.
  • To clean hard water deposits fromthe base or rocks:Soak the base and rocks in a mixture of vinegar and water toclean and remove any mineral build-up.
  • Keeping the water at an optimum level:Add water periodically to keep water level at an optimum levelto avoid shortening the life of the water pump. Fountainshould be “OFF” when refilling to avoid overflow.NOTE: Never let the water pump run without water. This willalso shorten the life of the water pump.
  • Fountain Storage:When not in use for long periods of time, unplug the fountainfrom the electrical outlet, empty the water and store in a cool,dry place.

Troubleshooting:

  • If the pump fails to operate, checkthe following:Check the household circuit breaker or plug unit into a differentoutlet to make sure the water pump is getting electrical power.NOTE: Always disconnect the unit from the electrical outletbefore handling the water pump.Check the water pump discharge and tubing for kinks andobstructions. Algae build-up can be flushed out in any faucet.Remove the water pump inlet to access the impeller area. Turnthe impeller to ensure it is not broken or jammed.Monthly maintenance will add to the life of your water pump.NOTE: Make sure that the electrical cord loops below the electricaloutlet to form a “drip loop”. This will prevent water from runningdown the cord into the electrical outlet (Fig.5).
  • If the pump is loud, gurgles, spews, or “burps”:Check the water level to make sure the water pump has enoughwater to function.NOTE: The pump must be completely submerged in water.
  • Obtaining a desired water level:Check the water level daily in the first week to measure therate of evaporation. Refill with water as needed.
  • If water is flowing unevenly:Check to see if the fountain is on a level surface. Then, runfingersacross fountain surface to help spread the water distribution.

Mail to:

HoMedics Consumer Relations Service Center Dept. 1683000 Pontiac Trail Commerce Township, MI 48390Email:

 

Read More About This Manual & Download PDF:

 

Homedics WF-MN-OAS EnviraScape Mini Oasis Tabletop Relaxation Fountain Instruction Manual and Warranty Information – Homedics WF-MN-OAS EnviraScape Mini Oasis Tabletop Relaxation Fountain Instruction Manual and Warranty Information –

[xyz-ips snippet=”download-snippet”]